Corneal Biomechanics and Biomaterials
The DOI matches its Crossref record; 81 of the 81 references it cites were found in a registry or an index.
Abstract
The ability to clearly observe one's environment in the visible spectrum provides a tremendous evolutionary advantage in most of the world's habitats. The complex optical processing system that has evolved in higher vertebrate animals gathers, focuses, detects, transduces, and interprets incoming visible light. The cornea resides at the front end of this imaging system, where it provides a clear optical aperture, substantial refractive power, and the structural stability required to protect the fragile intraocular components. Nature has resolved these simultaneous design requirements through an exceedingly clever manipulation of common extracellular-matrix structural materials (e.g., collagen and proteoglycans). In this review, we (a) examine the biophysical and optical roles of the cornea, (b) discuss increasingly popular approaches to altering its natural refractive properties with an emphasis on biomechanics, and (c) investigate the fast-rising science of corneal replacement via synthetic biomaterials. We close by considering relevant open problems that would benefit from the increased attention of bioengineers.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Riboflavin/ultraviolet-a–induced collagen crosslinking for the treatment of keratoconus
Wollensak, G., Spoerl, E., & Seiler, T. (2003) · American Journal of Ophthalmology · doi:10.1016/s0002-9394(02)02220-1 · Cited by 2,968
Corneal blindness: a global perspective.
Whitcher, J. P., Srinivasan, M., & Upadhyay, M. P. (2001) · Europe PMC (PubMed Central) · Cited by 1,563
Determining in vivo biomechanical properties of the cornea with an ocular response analyzer
Luce, D. A. (2005) · Journal of Cataract and Refractive Surgery · doi:10.1016/j.jcrs.2004.10.044 · Cited by 1,311
Wollensak, G., Spoerl, E., & Seiler, T. (2003) · Journal of Cataract and Refractive Surgery · doi:10.1016/s0886-3350(03)00407-3 · Cited by 1,024
Induction of Cross-links in Corneal Tissue
Spoerl, E., Huhle, M., & Seiler, T. G. (1998) · Experimental Eye Research · doi:10.1006/exer.1997.0410 · Cited by 980
APPLANATION TONOMETRY AND CENTRAL CORNEAL THICKNESS
EHLERS, N., BRAMSEN, T., & SPERLING, S. (1975) · Acta Ophthalmologica · doi:10.1111/j.1755-3768.1975.tb01135.x · Cited by 931
Liu, J., & Roberts, C. J. (2005) · Journal of Cataract and Refractive Surgery · doi:10.1016/j.jcrs.2004.09.031 · Cited by 753
Self-citationGoldmann, H., & Schmidt, T. (1957) · Ophthalmologica · doi:10.1159/000303213 · Cited by 607
Long-term graft survival after penetrating keratoplasty
Thompson, R. W., Price, M. O., Bowers, P. J., & Price, F. W. (2003) · Ophthalmology · doi:10.1016/s0161-6420(03)00463-9 · Cited by 607
Biomechanical properties of keratoconus and normal corneas
Andreassen, T. T., Hjorth Simonsen, A., & Oxlund, H. (1980) · Experimental Eye Research · doi:10.1016/s0014-4835(80)80027-3 · Cited by 540
Biomechanics and wound healing in the cornea
Dupps, W. J., & Wilson, S. E. (2006) · Experimental Eye Research · doi:10.1016/j.exer.2006.03.015 · Cited by 510
Changes in Collagen Orientation and Distribution in Keratoconus Corneas
Meek, K. M., Tuft, S. J., Huang, Y., Gill, P. S., Hayes, S., Newton, R. H., & Bron, A. J. (2005) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.04-1253 · Cited by 509
Kohlhaas, M., Spoerl, E., Schilde, T., Unger, G., Wittig, C., & Pillunat, L. E. (2006) · Journal of Cataract and Refractive Surgery · doi:10.1016/j.jcrs.2005.12.092 · Cited by 447
Fagerholm, P., Lagali, N. S., Merrett, K., Jackson, W. B., Munger, R., Liu, Y., Polarek, J. W., Söderqvist, M., & Griffith, M. (2010) · Science Translational Medicine · doi:10.1126/scitranslmed.3001022 · Cited by 420
Assessment of Corneal Biomechanical Properties and Their Variation with Age
Elsheikh, A., Wang, D., Brown, M., Rama, P., Campanelli, M., & Pye, D. (2007) · Current Eye Research · doi:10.1080/02713680601077145 · Cited by 394
Randleman, J. B., Dawson, D. G., Grossniklaus, H. E., McCarey, B. E., & Edelhauser, H. F. (2008) · Journal of Refractive Surgery · doi:10.3928/1081597x-20080101-15 · Cited by 312
The Boston Type I Keratoprosthesis
Aldave, A. J., Kamal, K. M., Vo, R. C., & Yu, F. (2009) · Ophthalmology · doi:10.1016/j.ophtha.2008.12.058 · Cited by 304
Genetic epidemiological study of keratoconus: Evidence for major gene determination
Wang, Y., Rabinowitz, Y. S., Rotter, J. I., & Yang, H. (2000) · American Journal of Medical Genetics · doi:10.1002/1096-8628(20000828)93:5<403::aid-ajmg11>3.0.co;2-a · Cited by 278
Strip Extensiometry for Comparison of the Mechanical Response of Bovine, Rabbit, and Human Corneas
Hoeltzel, D. A., Altman, P., Buzard, K., & Choe, K.-I. (1992) · Journal of Biomechanical Engineering · doi:10.1115/1.2891373 · Cited by 263
Chirila, T. V. (2001) · Biomaterials · doi:10.1016/s0142-9612(01)00168-5 · Cited by 257
Biomechanical properties of human and porcine corneas
Elsheikh, A., Alhasso, D., & Rama, P. (2008) · Experimental Eye Research · doi:10.1016/j.exer.2008.02.006 · Cited by 253
Pandolfi, A., & Holzapfel, G. A. (2008) · Journal of Biomechanical Engineering · doi:10.1115/1.2982251 · Cited by 245
High-Resolution Quantitative Imaging of Cornea Elasticity Using Supersonic Shear Imaging
Tanter, M., Touboul, D., Gennisson, J.-L., Bercoff, J., & Fink, M. (2009) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2009.2021471 · Cited by 234
Regional elastic performance of the human cornea
Hjortdal, J. Ø. (1996) · Journal of Biomechanics · doi:10.1016/0021-9290(95)00152-2 · Cited by 231
Chirila, T. V., Constable, I. J., Crawford, G. J., Vijayasekaran, S., Thompson, D. E., Chen, Y.-C., Fletcher, W. A., & Griffin, B. J. (1993) · Biomaterials · doi:10.1016/0142-9612(93)90072-a · Cited by 231
Corneal Biomechanical Metrics and Anterior Segment Parameters in Mild Keratoconus
Fontes, B. M., Ambrósio, R., Jardim, D., Velarde, G. C., & Nosé, W. (2010) · Ophthalmology · doi:10.1016/j.ophtha.2009.09.023 · Cited by 230
The mechanical properties of the rabbit and human cornea
Jue, B., & Maurice, D. M. (1986) · Journal of Biomechanics · doi:10.1016/0021-9290(86)90135-1 · Cited by 222
Intracorneal rings for keratoconus and keratectasia
Ertan, A., & Colin, J. (2007) · Journal of Cataract & Refractive Surgery · doi:10.1016/j.jcrs.2007.02.048 · Cited by 221
Computational modeling of mechanical anisotropy in the cornea and sclera
Pinsky, P. M., van der Heide, D., & Chernyak, D. (2005) · Journal of Cataract and Refractive Surgery · doi:10.1016/j.jcrs.2004.10.048 · Cited by 220
Comparative study of corneal strip extensometry and inflation tests
Elsheikh, A., & Anderson, K. (2005) · Journal of The Royal Society Interface · doi:10.1098/rsif.2005.0034 · Cited by 217
Constitutive Laws for Biomechanical Modeling of Refractive Surgery
Bryant, M. R., & McDonnell, P. J. (1996) · Journal of Biomechanical Engineering · doi:10.1115/1.2796033 · Cited by 213
Effect of Acute Biomechanical Changes on Corneal Curvature After Photokeratectomy
Dupps, W. J., & Roberts, C. (2001) · Journal of Refractive Surgery · doi:10.3928/1081-597x-20011101-05 · Cited by 212
Self-citationComparison of mechanical properties of keratoconus and normal corneas
Nash, I. S., Greene, P. S., & Foster, C. S. (1982) · Experimental Eye Research · doi:10.1016/0014-4835(82)90040-9 · Cited by 204
Glass, D. H., Roberts, C. J., Litsky, A. S., & Weber, P. A. (2008) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.07-1321 · Cited by 201
Self-citationZieske, J. D., Mason, V. S., Wasson, M. E., Meunier, S. F., Nolte, C. J. M., Fukai, N., Olsen, B. R., & Parenteau, N. L. (1994) · Experimental Cell Research · doi:10.1006/excr.1994.1300 · Cited by 196
Prelude to corneal tissue engineering – Gaining control of collagen organization
Ruberti, J. W., & Zieske, J. D. (2008) · Progress in Retinal and Eye Research · doi:10.1016/j.preteyeres.2008.08.001 · Cited by 193
Self-citationFull-field deformation of bovine cornea under constrained inflation conditions
Boyce, B. L., Grazier, J. M., Jones, R. E., & Nguyen, T. D. (2008) · Biomaterials · doi:10.1016/j.biomaterials.2008.06.011 · Cited by 191
Dawson, D. G., Randleman, J. B., Grossniklaus, H. E., O’Brien, T. P., Dubovy, S. R., Schmack, I., Stulting, R. D., & Edelhauser, H. F. (2008) · Ophthalmology · doi:10.1016/j.ophtha.2008.06.008 · Cited by 184
Biomechanics of the Cornea and Wavefront-guided Laser Refractive Surgery
Roberts, C. (2002) · Journal of Refractive Surgery · doi:10.3928/1081-597x-20020901-18 · Cited by 171
Self-citationWright, H. R., Turner, A., & Taylor, H. R. (2008) · The Lancet · doi:10.1016/s0140-6736(08)60836-3 · Cited by 165
Abahussin, M., Hayes, S., Knox Cartwright, N. E., Kamma-Lorger, C. S., Khan, Y., Marshall, J., & Meek, K. M. (2009) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.09-3669 · Cited by 162
Meek, K. M., Blamires, T., Elliott, G. F., Gyi, T. J., & Nave, C. (1987) · Current Eye Research · doi:10.3109/02713688709034853 · Cited by 161
Stress-controlled viscoelastic tensile response of bovine cornea
Boyce, B. L., Jones, R. E., Nguyen, T. D., & Grazier, J. M. (2007) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2006.12.001 · Cited by 154
Biomechanical Modeling of Refractive Corneal Surgery
Alastrué, V., Calvo, B., Peña, E., & Doblaré, M. (2006) · Journal of Biomechanical Engineering · doi:10.1115/1.2132368 · Cited by 152
Biomechanical analysis of the keratoconic cornea
Gefen, A., Shalom, R., Elad, D., & Mandel, Y. (2008) · Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials · doi:10.1016/j.jmbbm.2008.07.002 · Cited by 147
The use of X-ray scattering techniques to determine corneal ultrastructure
Meek, K. M., & Quantock, A. J. (2001) · Progress in Retinal and Eye Research · doi:10.1016/s1350-9462(00)00016-1 · Cited by 139
Collagen cross-linkage: a comprehensive review and directions for future research
Ashwin, P. T., & McDonnell, P. J. (2009) · British Journal of Ophthalmology · doi:10.1136/bjo.2009.164228 · Cited by 131
The distribution of strain in the human cornea
Shin, T. J., Vito, R. P., Johnson, L. W., & McCarey, B. E. (1997) · Journal of Biomechanics · doi:10.1016/s0021-9290(97)84433-8 · Cited by 129
Vinciguerra, P., Albè, E., Mahmoud, A. M., Trazza, S., Hafezi, F., & Roberts, C. J. (2010) · Journal of Refractive Surgery · doi:10.3928/1081597x-20100331-01 · Cited by 125
Self-citationAnterior chamber associated immune deviation: The privilege of immunity in the eye
Streilein, J. W. (1990) · Survey of Ophthalmology · doi:10.1016/0039-6257(90)90048-z · Cited by 124
Jaycock, P., Lobo, L., Ibrahim, J. S., Tyrer, J. R., & Marshall, J. (2005) · Journal of Cataract & Refractive Surgery · doi:10.1016/j.jcrs.2004.10.038 · Cited by 119
Hicks, C. R., Crawford, G. J., Dart, J. K. G., Grabner, G., Holland, E. J., Stulting, R. D., Tan, D. T. H., & Bulsara, M. K. (2006) · Cornea · doi:10.1097/01.ico.0000229982.23334.6b · Cited by 118
Protective role of corneal epithelium against ultraviolet radiation damage
Podskochy, A. (2004) · Acta Ophthalmologica Scandinavica · doi:10.1111/j.1600-0420.2004.00369.x · Cited by 118
Grytz, R., & Meschke, G. (2009) · Biomechanics and Modeling in Mechanobiology · doi:10.1007/s10237-009-0173-2 · Cited by 117
A Nonlinear Anisotropic Viscoelastic Model for the Tensile Behavior of the Corneal Stroma
Nguyen, T. D., Jones, R. E., & Boyce, B. L. (2008) · Journal of Biomechanical Engineering · doi:10.1115/1.2947399 · Cited by 109
Biomechanical model of human cornea based on stromal microstructure
Studer, H., Larrea, X., Riedwyl, H., & Büchler, P. (2009) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2009.11.021 · Cited by 104
Marshall, J. (1985) · Ophthalmic and Physiological Optics · doi:10.1111/j.1475-1313.1985.tb00666.x · Cited by 103
An inverse finite element method for determining the anisotropic properties of the cornea
Nguyen, T. D., & Boyce, B. L. (2010) · Biomechanics and Modeling in Mechanobiology · doi:10.1007/s10237-010-0237-3 · Cited by 102
Interlamellar cohesive strength in the vertical meridian of human eye bank corneas.
Smolek, M. K. (1993) · PubMed · Cited by 96
Surface Wave Elastometry of the Cornea in Porcine and Human Donor Eyes
Dupps, W. J., Netto, M. V., Herekar, S., & Krueger, R. R. (2007) · Journal of Refractive Surgery · doi:10.3928/1081-597x-20070101-11 · Cited by 95
Comparative studies of collagens in normal and keratoconus corneas
Zimmermann, D. R., Fischer, R. W., Winterhalter, K. H., Witmer, R., & Vaughan, L. (1988) · Experimental Eye Research · doi:10.1016/s0014-4835(88)80031-9 · Cited by 95
Roy, A. S., & Dupps, W. J. (2010) · Journal of Biomechanical Engineering · doi:10.1115/1.4002934 · Cited by 93
Vijayasekaran, S., Chirilă, T. V., Robertson, T. A., Lou, X., Fitton, J. H., Hicks, C. R., & Constable, I. J. (2000) · Journal of Biomaterials Science Polymer Edition · doi:10.1163/156856200743896 · Cited by 84
Changes in Central Corneal Thickness over Time
Brandt, J. D., Gordon, M. O., Beiser, J. A., Lin, S. C., Alexander, M., & Kass, M. A. (2008) · Ophthalmology · doi:10.1016/j.ophtha.2008.02.001 · Cited by 81
Finite element simulation of arcuates for astigmatism correction
Lanchares, E., Calvo, B., Cristóbal, J. Á., & Doblaré, M. (2008) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2007.11.010 · Cited by 75
Model for nonectatic increase in posterior corneal elevation after ablative procedures
Grzybowski, D. M., Roberts, C. J., Mahmoud, A. M., & Chang, J. S. M. (2005) · Journal of Cataract & Refractive Surgery · doi:10.1016/j.jcrs.2004.10.045 · Cited by 66
Self-citationNew Dacron tissue colonisable keratoprosthesis: clinical experience.
Pintucci, S., Pintucci, F., Cecconi, M., & Caiazza, S. (1995) · British Journal of Ophthalmology · doi:10.1136/bjo.79.9.825 · Cited by 58
Plasma surface modification of artificial corneas for optimal epithelialization
Latkany, R., Tsuk, A. G., Sheu, M.-S., Loh, I. H., & Trinkaus‐Randall, V. (1997) · Journal of Biomedical Materials Research · doi:10.1002/(sici)1097-4636(199707)36:1<29::aid-jbm4>3.0.co;2-n · Cited by 58
Development of a biopolymeric keratoprosthetic material. Evaluation in vitro and in vivo.
Trinkaus‐Randall, V., Capecchi, J., Newton, A., Vadasz, A. G., Leibowitz, H. M., & Franzblau, C. (1988) · PubMed · Cited by 56
Finite element analysis applied to cornea reshaping
DeBuc, D. C., Niazy, A.-S. M., Kurtz, R. M., Djotyan, G. P., & Juhasz, T. (2005) · Journal of Biomedical Optics · doi:10.1117/1.2136149 · Cited by 55
Numerical Study of the Effect of Corneal Layered Structure on Ocular Biomechanics
Elsheikh, A., Ross, S., Alhasso, D., & Rama, P. (2009) · Current Eye Research · doi:10.1080/02713680802535263 · Cited by 54
Computer Simulation of Arcuate Keratotomy for Astigmatism
Hanna, K. D., Jouve, F., Waring, G. O., & Ciarlet, P. G. (1992) · Journal of Refractive Surgery · doi:10.3928/1081-597x-19920301-11 · Cited by 51
CORNEAL FLUID METABOLISM: Experiments and Observations
BOCK, R. H., & MAUMENEE, A. E. (1953) · A M A Archives of Ophthalmology · doi:10.1001/archopht.1953.00920030289003 · Cited by 43
The Evidentiary Significance of Case Reports: Eye Rubbing and Keratoconus
McMonnies, C. W. (2008) · Optometry and Vision Science · doi:10.1097/opx.0b013e318169287a · Cited by 36
On the Computer-Aided and Optimal Design of Keratorefractive Surgery
Velinsky, S. A., & Bryant, M. R. (1992) · Journal of Refractive Surgery · doi:10.3928/1081-597x-19920301-13 · Cited by 34
Katsube, N., Wang, R., Okuma, E., & Roberts, C. J. (2002) · Journal of Refractive Surgery · doi:10.3928/1081-597x-20020901-19 · Cited by 28
Self-citationRuberti, J. W., Zieske, J. D., & Trinkaus‐Randall, V. (2007) · Elsevier eBooks · doi:10.1016/b978-012370615-7/50072-x · Cited by 25
Self-citationBiological response to a synthetic cornea
Trinkaus‐Randall, V., & Nugent, M. A. (1998) · Journal of Controlled Release · doi:10.1016/s0168-3659(97)00254-x · Cited by 24
Navarro, R., Palos, F., Lanchares, E., Calvo, B., & Cristóbal, J. Á. (2008) · Journal of Cataract & Refractive Surgery · doi:10.1016/j.jcrs.2008.09.015 · Cited by 19
Mathematical modelling of corneal swelling
Li, L.-Y., Tighe, B. J., & Ruberti, J. W. (2004) · Biomechanics and Modeling in Mechanobiology · doi:10.1007/s10237-004-0054-7 · Cited by 17
Self-citationEvans, M. D. M., & Sweeney, D. F. (2010) · Elsevier eBooks · doi:10.1533/9781845697433.1.65 · Cited by 9
Cited by
Corneal Collagen Crosslinking: A Systematic Review
Sorkin, N., & Varssano, D. (2014) · Ophthalmologica · doi:10.1159/000357979 · Cited by 1,918
Hinz, B. (2016) · Experimental Eye Research · doi:10.1016/j.exer.2015.07.009 · Cited by 424
Han, H., Li, S., Xu, M., Zhong, Y., Fan, W., Xu, J., Zhou, T., Ji, J., Ye, J., & Yao, K. (2023) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2023.114770 · Cited by 322
Risk Factors for Progression to Penetrating Keratoplasty in Patients With Keratoconus
Reeves, S. W., Stinnett, S., Adelman, R. A., & Afshari, N. A. (2005) · American Journal of Ophthalmology · doi:10.1016/j.ajo.2005.05.029 · Cited by 290
Corneal Tissue Engineering: Recent Advances and Future Perspectives
Ghezzi, C. E., Rnjak-Kovacina, J., & Kaplan, D. L. (2015) · Tissue Engineering Part B: Reviews · doi:10.1089/ten.teb.2014.0397 · Cited by 218
“A high concentration of small leucine-rich proteoglycans, including decorin, lumican, keratocan, decorated with dermatan sulfate and keratan sulfate are present in the lamellae, credited with maintaining the interfibrillar spacing required for transparency, as well as contributing to regulation of corneal hydration [1…”
Influential
Metadata
- Authors
- Ruberti, J. W., Sinha Roy, A., & Roberts, C. J.
- Venue
- Annual Review of Biomedical Engineering
- Publisher
- Annual Reviews
- Published
- 2011-08-15
- Volume
- 13
- Issue
- 1
- Pages
- 269-295
- ISSN
- 1523-9829 (ISSN-L)
- 1545-4274
- OpenAlex
- W2170365711
- Cited by
- 241
- References
- 81
- FWCI
- 1.57
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.