Contrast Agents for MR Imaging of the Liver
The DOI matches its Crossref record; 38 of the 38 references it cites were found in a registry or an index.
Abstract
A variety of different categories of contrast agents, and within each category a number of individual agents, are currently available for clinical use in magnetic resonance (MR) imaging of the liver. In this review, the use of nonspecific extracellular gadolinium chelates, reticuloendothelial system-specific iron oxide particulate agents, hepatocyte-selective agents, and combined perfusion and hepatocyte-selective agents are described. Most clinical experience is with nonspecific extracellular gadolinium chelates. The relatively low cost, safety, good patient tolerance, and ability to help detect and characterize a wide range of liver diseases have rendered gadolinium chelates as commonly used agents. Reticuloendothelial system-specific agents improve lesion detection by decreasing the signal intensity of background liver on T2-weighted MR images, which increases the conspicuity of focal hepatic lesions with negligible reticuloendothelial cells (eg, metastases). Hepatocyte-selective agents increase the signal intensity of background liver on T1-weighted images, which increases the conspicuity of focal lesions that do not contain hepatocytes (eg, metastases). The clinical application of the different categories of contrast agents, techniques for their administration, sequences to be used, and appearances of common entities on contrast agent-enhanced studies are described.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Weissleder, R., Elizondo, G., Wittenberg, J., Rabito, C. A., Bengele, H. H., & Josephson, L. (1990) · Radiology · doi:10.1148/radiology.175.2.2326474 · Cited by 1,028
Hamm, B., Staks, T., Mühler, A., Bollow, M., Taupitz, M., Frenzel, T., Wolf, K. J., Weinmann, H. J., & Lange, L. (1995) · Radiology · doi:10.1148/radiology.195.3.7754011 · Cited by 575
Abdominal MR Imaging with a Volumetric Interpolated Breath-hold Examination
Rofsky, N. M., Lee, V. S., Laub, G., Pollack, M. A., Krinsky, G. A., Thomasson, D., Ambrosino, M. M., & Weinreb, J. C. (1999) · Radiology · doi:10.1148/radiology.212.3.r99se34876 · Cited by 538
Liver tumors: comparison of MR imaging with Gd-EOB-DTPA and Gd-DTPA.
Vogl, T. J., Kümmel, S., Hammerstingl, R., Schellenbeck, M., Schumacher, G., Balzer, T., Schwarz, W., Müller, P. K., Bechstein, W. O., Mack, M. G., et al. (1996) · Radiology · doi:10.1148/radiology.200.1.8657946 · Cited by 453
Preclinical evaluation of Gd-EOB-DTPA as a contrast agent in MR imaging of the hepatobiliary system.
Schuhmann-Giampieri, G., Schmitt-Willich, H., Press, W. R., Negishi, C., Weinmann, H. J., & Speck, U. (1992) · Radiology · doi:10.1148/radiology.183.1.1549695 · Cited by 380
Senéterre, E., Taourel, P., Bouvier, Y., Pradel, J., Van Beers, B., Daures, J. P., Pringot, J., Mathieu, D., & Bruel, J. M. (1996) · Radiology · doi:10.1148/radiology.200.3.8756932 · Cited by 310
Semelka, R. C., Brown, E. D., Ascher, S. M., Patt, R. H., Bagley, A. S., Li, W., Edelman, R. R., Shoenut, J. P., & Brown, J. J. (1994) · Radiology · doi:10.1148/radiology.192.2.8029404 · Cited by 309
Self-citationPhase II clinical evaluation of Gd-EOB-DTPA: dose, safety aspects, and pulse sequence.
Reimer, P., Rummeny, E. J., Shamsi, K., Balzer, T., Daldrup, H. E., Tombach, B., Hesse, T., Berns, T., & Peters, P. E. (1996) · Radiology · doi:10.1148/radiology.199.1.8633143 · Cited by 309
Ros, P. R., Freeny, P. C., Harms, S. E., Seltzer, S. E., Davis, P. L., Chan, T. W., Stillman, A. E., Muroff, L. R., Runge, V. M., & Nissenbaum, M. A. (1995) · Radiology · doi:10.1148/radiology.196.2.7617864 · Cited by 278
Semelka, R. C., Martin, D. R., Balci, C., & Lance, T. (2001) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.1057 · Cited by 274
Self-citationYamashita, Y., Mitsuzaki, K., Yi, T., Ogata, I., Nishiharu, T., Urata, J., & Takahashi, M. (1996) · Radiology · doi:10.1148/radiology.200.1.8657948 · Cited by 272
Hagspiel, K. D., Neidl, K. F., Eichenberger, A. C., Weder, W., & Marincek, B. (1995) · Radiology · doi:10.1148/radiology.196.2.7617863 · Cited by 254
A new lipophilic gadolinium chelate as a tissue‐specific contrast medium for MRI
Weinmann, H. ‐., Schuhmann‐Giampieri, G., Schmitt‐Willich, H., Vogler, H., Frenzel, T., & Gries, H. (1991) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910220214 · Cited by 237
Ward, J., Naik, K. S., Guthrie, J. A., Wilson, D., & Robinson, P. J. (1999) · Radiology · doi:10.1148/radiology.210.2.r99fe05459 · Cited by 230
Gadobenate Dimeglumine (Gd-BOPTA): An Overview
KIRCHIN, M. A., PIROVANO, G. P., & SPINAZZI, A. (1998) · Investigative Radiology · doi:10.1097/00004424-199811000-00003 · Cited by 218
Spinazzi, A., Lorusso, V., Pirovano, G., & Kirchin, M. (1999) · Academic Radiology · doi:10.1016/s1076-6332(99)80451-6 · Cited by 204
Hamm, B., Thoeni, R. F., Gould, R. G., Bernardino, M. E., Lüning, M., Saini, S., Mahfouz, A. E., Taupitz, M., & Wolf, K. J. (1994) · Radiology · doi:10.1148/radiology.190.2.8284392 · Cited by 204
Petersein, J., Spinazzi, A., Giovagnoni, A., Soyer, P., Terrier, F., Lencioni, R., Bartolozzi, C., Grazioli, L., Chiesa, A., Manfredi, R., et al. (2000) · Radiology · doi:10.1148/radiology.215.3.r00jn14727 · Cited by 187
Vogl, T. J., Hammerstingl, R., Schwarz, W., Mack, M. G., Müller, P. K., Pegios, W., Keck, H., Eibl-Eibesfeldt, A., Hoelzl, J., Woessmer, B., et al. (1996) · Radiology · doi:10.1148/radiology.198.3.8628887 · Cited by 186
Clinical results with Resovist: a phase 2 clinical trial.
Reimer, P., Rummeny, E. J., Daldrup, H. E., Balzer, T., Tombach, B., Berns, T., & Peters, P. E. (1995) · Radiology · doi:10.1148/radiology.195.2.7724772 · Cited by 182
Semelka, R. C., Shoenut, J. P., Kroeker, M. A., Greenberg, H. M., Simm, F. C., Minuk, G. Y., Kroeker, R. M., & Micflikier, A. B. (1992) · Radiology · doi:10.1148/radiology.184.3.1324509 · Cited by 167
Self-citationMahfouz, A. E., Hamm, B., & Wolf, K. J. (1994) · Radiology · doi:10.1148/radiology.190.1.8259426 · Cited by 166
Semelka, R. C., Cumming, M. J., Shoenut, J. P., Magro, C. M., Yaffe, C. S., Kroeker, M. A., & Greenberg, H. M. (1993) · Radiology · doi:10.1148/radiology.186.3.8381551 · Cited by 159
Self-citationLiver metastases: safety and efficacy of detection with superparamagnetic iron oxide in MR imaging.
Bellin, M. F., Zaim, S., Auberton, E., Sarfati, G., Duron, J. J., Khayat, D., & Grellet, J. (1994) · Radiology · doi:10.1148/radiology.193.3.7972804 · Cited by 148
Larson, R. E., Semelka, R. C., Bagley, A. S., Molina, P. L., Brown, E. D., & Lee, J. K. (1994) · Radiology · doi:10.1148/radiology.192.2.8029403 · Cited by 139
Self-citationLow, R. N., Francis, I. R., Sigeti, J. S., & Foo, T. (1993) · Radiology · doi:10.1148/radiology.186.3.8430191 · Cited by 137
Hepatic lesions: detection with ferumoxide-enhanced T1-weighted MR imaging.
Oudkerk, M., van den Heuvel, A. G., Wielopolski, P. A., Schmitz, P. I., Borel Rinkes, I. H., & Wiggers, T. (1997) · Radiology · doi:10.1148/radiology.203.2.9114103 · Cited by 113
Safety and Pharmacokinetic Profile of Gadobenate Dimeglumine in Subjects With Renal Impairment
Swan, S. K., Lambrecht, L. J., Townsend, R. R., DAVIES, B. E., McCLOUD, S., PARKER, J. R., Bensel, K. S., & LaFrance, N. D. (1999) · Investigative Radiology · doi:10.1097/00004424-199907000-00001 · Cited by 97
Low, R. N., Semelka, R. C., Worawattanakul, S., Alzate, G. D., & Sigeti, J. S. (1999) · Radiology · doi:10.1148/radiology.210.3.r99mr46625 · Cited by 93
Self-citationMR imaging properties and pharmacokinetics of MnDPDP in healthy volunteers
Wang, C., Gordon, P. B., Hustvedt, S. O., Grant, D., Sterud, A. T., Martinsen, I., Ahlström, H. K., & Hemmingsson, A. (1997) · Acta Radiologica · doi:10.1080/02841859709172399 · Cited by 84
Winter, T. C., Freeny, P. C., Nghiem, H. V., Mack, L. A., Patten, R. M., Thomas, C., & Elliott, S. (1993) · American Journal of Roentgenology · doi:10.2214/ajr.161.6.8249724 · Cited by 81
MultiHance clinical pharmacology: Biodistribution and MR enhancement of the liver
Spinazzi, A., Lorusso, V., Pirovano, G., Taroni, P., Kirchin, M. A., & Davies, A. (1998) · Academic Radiology · doi:10.1016/s1076-6332(98)80069-x · Cited by 80
Malignant lesions of the liver with high signal intensity on T1‐Weighted MR images
Kelekis, N., Semelka, R. C., & Woosley, J. T. (1996) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.1880060206 · Cited by 75
Self-citationHepatic lesion detection at MR imaging: a comparative study with four sequences.
Blakeborough, A., Ward, J., Wilson, D. J., Griffiths, M., Kajiya, Y., Guthrie, J. A., & Robinson, P. J. (1997) · Radiology · doi:10.1148/radiology.203.3.9169701 · Cited by 72
Differentiation of hepatomas from nonhepatomatous masses: Use of MnDPDP-enhanced MR images
Liou, J., Lee, J. K. T., Borrello, J. A., & Brown, J. J. (1994) · Magnetic Resonance Imaging · doi:10.1016/0730-725x(94)92354-x · Cited by 61
Semelka, R. C., Shoenut, J. P., Ascher, S. M., et al. (1994) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.1880040316 · Cited by 54
Self-citationHepatic metastases: CT versus MR imaging at 1.5T
Vassiliades, V. G., Foley, W. D., Alarcon, J., et al. (1991) · Abdominal Imaging · doi:10.1007/bf01887334 · Cited by 46
Morana, G., Grazioli, L., Schneider, G. K., Testoni, M., Menni, K., Chiesa, A., & Procacci, C. (2002) · Academic Radiology · doi:10.1016/s1076-6332(03)80268-4 · Cited by 22
Cited by
Applications of magnetic nanoparticles in biomedicine
Pankhurst, Q. A., Connolly, J., Jones, S. K., & Dobson, J. (2003) · Journal of Physics D: Applied Physics · doi:10.1088/0022-3727/36/13/201 · Cited by 5,881
Magnetic nanoparticles in MR imaging and drug delivery
Sun, C., Lee, J. S. H., & Zhang, M. (2008) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2008.03.018 · Cited by 2,594
Applications of Magnetic Nanoparticles in Biomedicine
Bárcena, C., Sra, A. K., & Gao, J. (2009) · Nanoscale Magnetic Materials and Applications · doi:10.1007/978-0-387-85600-1_20 · Cited by 2,565
Inorganic Nanoparticles for MRI Contrast Agents
Na, H. B., Song, I. C., & Hyeon, T. (2009) · Advanced Materials · doi:10.1002/adma.200802366 · Cited by 1,781
Recent advances in iron oxide nanocrystal technology for medical imaging☆
COROT, C., ROBERT, P., IDEE, J., & PORT, M. (2006) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2006.09.013 · Cited by 1,465
Metadata
- Authors
- Semelka, R. C., & Helmberger, T. K. G.
- Venue
- Radiology
- Published
- 2001-01
- Volume
- 218
- Issue
- 1
- Pages
- 27-38
- ISSN
- 0033-8419 (ISSN-L)
- 1527-1315
- OpenAlex
- W2077309466
- Cited by
- 337
- References
- 38
- FWCI
- 13.74
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.