The DOI matches its Crossref record.
The Development of Subretinal Microphotodiodes for Replacement of Degenerated Photoreceptors
Abstract
There are presently several concepts to restore vision in blind or highly visually handicapped persons by implanting electronic devices into the eye in order to partially restore vision. Here, the approach to replace retinal photoreceptors by a subretinally implanted microphotodiode array (MPDA) is summarized. A survey is given on the present state of the development of MPDAs, the possibility of in vitro and in vivo tests as well as first results on biocompatibility and histology. Additionally, electrophysiological recordings in rabbits and rats are presented which have received such subretinal implants.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Visual perception in a blind subject with a chronic microelectronic retinal prosthesis
Humayun, M. S., Weiland, J. D., Fujii, G. Y., Greenberg, R., Williamson, R., Little, J., Mech, B., Cimmarusti, V., Van Boemel, G., Dagnelie, G., et al. (2003) · Vision Research · doi:10.1016/s0042-6989(03)00457-7 · Cited by 856
Will Retinal Implants Restore Vision?
Zrenner, E. (2002) · Science · doi:10.1126/science.1067996 · Cited by 724
Self-citationPattern electrical stimulation of the human retina
Humayun, M. S., de Juan Jr., E., Weiland, J. D., Dagnelie, G., Katona, S., Greenberg, R., & Suzuki, S. (1999) · Vision Research · doi:10.1016/s0042-6989(99)00052-8 · Cited by 592
The Artificial Silicon Retina Microchip for the Treatment of VisionLoss From Retinitis Pigmentosa
Chow, A. Y. (2004) · Archives of Ophthalmology · doi:10.1001/archopht.122.4.460 · Cited by 511
Retinal Prosthesis for the Blind
Margalit, E., Maia, M., Weiland, J. D., Greenberg, R. J., Fujii, G. Y., Torres, G., Piyathaisere, D. V., O'Hearn, T. M., Liu, W., Lazzi, G., et al. (2002) · Survey of Ophthalmology · doi:10.1016/s0039-6257(02)00311-9 · Cited by 427
Spatiotemporal dynamics of continuum neural fields
Bressloff, P. C. (2012) · Journal of Physics A: Mathematical and Theoretical · doi:10.1088/1751-8113/45/3/033001 · Cited by 414
A neural interface for a cortical vision prosthesis
Normann, R. A., Maynard, E. M., Rousche, P. J., & Warren, D. J. (1999) · Vision Research · doi:10.1016/s0042-6989(99)00040-1 · Cited by 409
A neuro-stimulus chip with telemetry unit for retinal prosthetic device
Liu, W., Vichienchom, K., Clements, M., DeMarco, S. C., Hughes, C., McGucken, E., Humayun, M. S., De Juan, E., Weiland, J. D., & Greenberg, R. (2000) · IEEE Journal of Solid-State Circuits · doi:10.1109/4.871327 · Cited by 371
Can subretinal microphotodiodes successfully replace degenerated photoreceptors?
Zrenner, E., Stett, A., Weiss, S., Aramant, R. B., Guenther, E., Kohler, K., Miliczek, K.-D., Seiler, M. J., & Haemmerle, H. (1999) · Vision Research · doi:10.1016/s0042-6989(98)00312-5 · Cited by 290
Self-citationPattern recognition with the optic nerve visual prosthesis
Veraart, C., Wanet‐Defalque, M., Gérard, B., Vanlierde, A., & Delbeke, J. (2003) · Artificial Organs · doi:10.1046/j.1525-1594.2003.07305.x · Cited by 259
Electrical multisite stimulation of the isolated chicken retina
Stett, A., Barth, W., Weiss, S., Haemmerle, H., & Zrenner, E. (2000) · Vision Research · doi:10.1016/s0042-6989(00)00005-5 · Cited by 259
Self-citationWilke, R., Gabel, V.-P., Sachs, H., Bartz Schmidt, K.-U., Gekeler, F., Besch, D., Szurman, P., Stett, A., Wilhelm, B., Peters, T., et al. (2011) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.10-6946 · Cited by 155
Self-citationBiostability of micro‐photodiode arrays for subretinal implantation
Hämmerle, H., Kobuch, K., Kohler, K., Nisch, W., Sachs, H., & Stelzle, M. (2002) · Biomaterials · doi:10.1016/s0142-9612(01)00185-5 · Cited by 146
“Prototype devices have already been implanted subretinally in animals between the neuronal layer and the pigment epithelium [3,4].”
BackgroundMethodSelf-citationMaynard, E. M. (2001) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.3.1.145 · Cited by 126
Implantable bioelectronic interfaces for lost nerve functions
Heiduschka, P., & Thanos, S. (1998) · Progress in Neurobiology · doi:10.1016/s0301-0082(98)00013-6 · Cited by 126
Sommerhalder, J., Rappaz, B., de Haller, R., Fornos, A. P., Safran, A. B., & Pelizzone, M. (2004) · Vision Research · doi:10.1016/j.visres.2004.01.017 · Cited by 116
Simulation of artificial vision: I. Eccentric reading of isolated words, and perceptual learning
Sommerhalder, J., Oueghlani, E., Bagnoud, M., Leonards, U., Safran, A. B., & Pelizzone, M. (2003) · Vision Research · doi:10.1016/s0042-6989(02)00481-9 · Cited by 111
“Zrenner et al. (1997) as well as Peyman et al. (1998) have already manufactured such first prototypes.”
Artificial vision through neuronal stimulation
Fernandes, R. A. B., Diniz, B., Ribeiro, R., & Humayun, M. (2012) · Neuroscience Letters · doi:10.1016/j.neulet.2012.01.063 · Cited by 90
Psychophysical evaluation for visual prosthesis
Dagnelie, G. (2008) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.10.061807.160529 · Cited by 82
“Although some long-held tenets of neuroscience have had to yield to the reality of phosphenes elicited through intraocular stimulation (21, 22), others stand unchallenged.”
BackgroundSakaguchi, H., Kamei, M., Fujikado, T., Yonezawa, E., Ozawa, M., Cecilia-Gonzalez, C., Ustariz-Gonzalez, O., Quiroz-Mercado, H., & Tano, Y. (2009) · Journal of Artificial Organs · doi:10.1007/s10047-009-0467-2 · Cited by 58
Naycheva, L., Schatz, A., Röck, T., Willmann, G., Messias, A., Bartz-Schmidt, K. U., Zrenner, E., & Gekeler, F. (2012) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.12-9612 · Cited by 55
Self-citation
Metadata
- Authors
- Zrenner, E., Miliczek, K.-D., Gabel, V. P., Graf, H. G., Guenther, E., Haemmerle, H., Hoefflinger, B., Kohler, K., Nisch, W., Schubert, M., Stett, A., & Weiss, S.
- Venue
- Ophthalmic Research
- Publisher
- S. Karger AG
- Published
- 1997
- Volume
- 29
- Issue
- 5
- Pages
- 269-280
- ISSN
- 0030-3747 (ISSN-L)
- 1423-0259
- OpenAlex
- W2014429820
- Cited by
- 214
- References
- 0
- FWCI
- 4.39
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.