Radiation Dose in Computed Tomography of the Heart
Open accessThe DOI matches its Crossref record; 18 of the 18 references it cites were found in a registry or an index.
Abstract
C urrently, computed tomographic (CT) imaging of the heart is mainly used for the quantification of coronary artery calcification as an indirect measure of coronary plaque burden 1,2 and, less frequently, for minimally invasive coronary angiography.3 CT imaging of the heart and coronary arteries without unsharpness due to motion artifact first became possible with the introduction of electron beam computed tomography (EBCT) in 1983.4 More recently, so-called multislice spiral computed tomographic (MSCT) scanners with gantry rotation speeds fast enough to produce diagnostic images of the heart under certain conditions have become widely available.5 As a consequence, cardiac CT imaging, most often performed for the purpose of calcium scoring, 2 is increasingly applied to the general public.In many centers, patients have access to such studies without physician referral.This has created concerns for public health because of the radiation dose associated with CT imaging.6 -8 Many clinicians and researchers working with patients with cardiovascular diseases may yet be unfamiliar with the radiation doses that are received during various cardiac CT imaging protocols and how they differ between the various scanner types that are currently used.To further complicate matters, radiation dose estimates can be expressed in various ways.For these reasons, the doses reported in previous publications on cardiac CT have varied widely, and it is not always clear what parameters were being reported.3,9 -11 The purpose of this article is to discuss the current concepts of radiation dose measurement and estimation in CT imaging and to provide comparative estimates for radiation doses received during cardiac examinations with use of EBCT or MSCT.This information may be helpful to physicians who perform calcium scoring, counsel patients contemplating cardiac calcium scoring, or are considering referring their patients for such studies.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Recommendations of the International Commission on Radiological Protection
(1961) · Postgraduate Medical Journal · doi:10.1136/pgmj.37.425.168-b · Cited by 5,862
International Electrotechnical Commission
Buck, J. (2010) · Handbook of Transnational Economic Governance Regimes · doi:10.1163/ej.9789004163300.i-1081.494 · Cited by 2,742
Recommendations of the International Commission on Radiological Protection Publication 60
Icrp (1991) · Annals of the ICRP · Cited by 835
Rumberger, J. A., Brundage, B. H., Rader, D. J., & Kondos, G. (1999) · Mayo Clinic Proceedings · doi:10.4065/74.3.243 · Cited by 796
Coronary angiography with multi-slice computed tomography
Nieman, K., Oudkerk, M., Rensing, B. J., van Ooijen, P., Munne, A., van Geuns, R.-J., & de Feyter, P. J. (2001) · The Lancet · doi:10.1016/s0140-6736(00)04058-7 · Cited by 725
Jakobs, T. F., Becker, C. R., Ohnesorge, B., Flohr, T., Suess, C., Schoepf, U. J., & Reiser, M. F. (2002) · European Radiology · doi:10.1007/s00330-001-1278-x · Cited by 615
A method for describing the doses delivered by transmission x-ray computed tomography
Shope, T. B., Gagne, R. M., & Johnson, G. C. (1981) · Medical Physics · doi:10.1118/1.594995 · Cited by 435
Noninvasive Coronary Angiography by Retrospectively ECG-Gated Multislice Spiral CT
Achenbach, S., Ulzheimer, S., Baum, U., Kachelrieß, M., Ropers, D., Giesler, T., Bautz, W., Daniel, W. G., Kalender, W. A., & Moshage, W. (2000) · Circulation · doi:10.1161/01.cir.102.23.2823 · Cited by 434
Performance evaluation of a multi-slice CT system
McCollough, C. H., & Zink, F. E. (1999) · Medical Physics · doi:10.1118/1.598777 · Cited by 386
Self-citationAchenbach, S., Moshage, W., Ropers, D., Nossen, J., & Daniel, W. G. (1998) · New England Journal of Medicine · doi:10.1056/nejm199812313392702 · Cited by 382
Cited by
Effective Doses in Radiology and Diagnostic Nuclear Medicine: A Catalog
Mettler, F. A., Huda, W., Yoshizumi, T. T., & Mahesh, M. (2008) · Radiology · doi:10.1148/radiol.2481071451 · Cited by 2,008
Writing Committee Members, Greenland, P., Alpert, J. S., Beller, G. A., Benjamin, E. J., Budoff, M. J., Fayad, Z. A., Foster, E., Hlatky, M. A., Hodgson, J. M., et al. (2010) · Circulation · doi:10.1161/cir.0b013e3182051b4c · Cited by 1,873
Budoff, M. J., Achenbach, S., Blumenthal, R. S., Carr, J. J., Goldin, J. G., Greenland, P., Guerci, A. D., Lima, J. A. C., Rader, D. J., Rubin, G. D., et al. (2006) · Circulation · doi:10.1161/circulationaha.106.178458 · Cited by 1,398
2010 ACCF/AHA Guideline for Assessment of Cardiovascular Risk in Asymptomatic Adults
Greenland, P., Alpert, J. S., Beller, G. A., Benjamin, E. J., Budoff, M. J., Fayad, Z. A., Foster, E., Hlatky, M. A., Hodgson, J. M., Kushner, F. G., et al. (2010) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2010.09.001 · Cited by 1,324
Estimated Radiation Dose Associated With Cardiac CT Angiography
Hausleiter, J. (2009) · JAMA · doi:10.1001/jama.2009.54 · Cited by 1,000
American College of Radiology White Paper on Radiation Dose in Medicine
Amis, E. S., Butler, P. F., Applegate, K. E., Birnbaum, S. B., Brateman, L. F., Hevezi, J. M., Mettler, F. A., Morin, R. L., Pentecost, M. J., Smith, G. G., et al. (2007) · Journal of the American College of Radiology · doi:10.1016/j.jacr.2007.03.002 · Cited by 902
Self-citationCarr, J. J., Nelson, J. C., Wong, N. D., McNitt-Gray, M., Arad, Y., Jacobs, D. R., Sidney, S., Bild, D. E., Williams, O. D., & Detrano, R. C. (2005) · Radiology · doi:10.1148/radiol.2341040439 · Cited by 853
Radiation Dose to Patients From Cardiac Diagnostic Imaging
Einstein, A. J., Moser, K. W., Thompson, R. C., Cerqueira, M. D., & Henzlova, M. J. (2007) · Circulation · doi:10.1161/circulationaha.107.688101 · Cited by 806
Atherothrombosis and High-Risk Plaque
Fuster, V., Moreno, P. R., Fayad, Z. A., Corti, R., & Badimon, J. J. (2005) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2005.03.074 · Cited by 738
Hausleiter, J., Meyer, T., Hadamitzky, M., Huber, E., Zankl, M., Martinoff, S., Kastrati, A., & Schömig, A. (2006) · Circulation · doi:10.1161/circulationaha.105.602490 · Cited by 705
Goldstein, J. A., Gallagher, M. J., O’Neill, W. W., Ross, M. A., O’Neil, B. J., & Raff, G. L. (2007) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2006.08.064 · Cited by 643
Earls, J. P., Berman, E. L., Urban, B. A., Curry, C. A., Lane, J. L., Jennings, R. S., McCulloch, C. C., Hsieh, J., & Londt, J. H. (2008) · Radiology · doi:10.1148/radiol.2463070989 · Cited by 543
SCCT guidelines on radiation dose and dose-optimization strategies in cardiovascular CT
Halliburton, S. S., Abbara, S., Chen, M. Y., Gentry, R., Mahesh, M., Raff, G. L., Shaw, L. J., & Hausleiter, J. (2011) · Journal of Cardiovascular Computed Tomography · doi:10.1016/j.jcct.2011.06.001 · Cited by 491
Bluemke, D. A., Achenbach, S., Budoff, M., Gerber, T. C., Gersh, B., Hillis, L. D., Hundley, W. G., Manning, W. J., Printz, B. F., Stuber, M., et al. (2008) · Circulation · doi:10.1161/circulationaha.108.189695 · Cited by 461
Self-citationICRP Publication 120: Radiological Protection in Cardiology
Cousins, C., Miller, D. L., Bernardi, G., Rehani, M. M., Schofield, P., Vañó, E., Einstein, A. J., Geiger, B., Heintz, P., Padovani, R., et al. (2013) · Annals of the ICRP · doi:10.1016/j.icrp.2012.09.001 · Cited by 428
Multislice spiral computed tomography coronary angiography in patients with stable angina pectoris
Mollet, N. R., Cademartiri, F., Nieman, K., Saia, F., Lemos, P. A., McFadden, E. P., Pattynama, P. M. T., Serruys, P. W., Krestin, G. P., & de Feyter, P. J. (2004) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2004.03.032 · Cited by 406
Multi–Detector Row CT Systems and Image-Reconstruction Techniques
Flohr, T. G., Schaller, S., Stierstorfer, K., Bruder, H., Ohnesorge, B. M., & Schoepf, U. J. (2005) · Radiology · doi:10.1148/radiol.2353040037 · Cited by 381
Schoepf, U. J., Becker, C. R., Ohnesorge, B. M., & Yucel, E. K. (2004) · Radiology · doi:10.1148/radiol.2321030636 · Cited by 356
Sustainability of medical imaging
Picano, E. (2004) · BMJ · doi:10.1136/bmj.328.7439.578 · Cited by 321
Hirai, N., Horiguchi, J., Fujioka, C., Kiguchi, M., Yamamoto, H., Matsuura, N., Kitagawa, T., Teragawa, H., Kohno, N., & Ito, K. (2008) · Radiology · doi:10.1148/radiol.2482071804 · Cited by 293
Gentile, F., Castiglione, V., & De Caterina, R. (2021) · Circulation · doi:10.1161/circulationaha.121.055347 · Cited by 281
Accuracy of thin-slice computed tomography in the detection of coronary stenoses
MARTUSCELLI, E. (2004) · European Heart Journal · doi:10.1016/j.ehj.2004.03.024 · Cited by 259
Desjardins, B., & Kazerooni, E. A. (2004) · American Journal of Roentgenology · doi:10.2214/ajr.182.4.1820993 · Cited by 192
Schroeder, S., Kuettner, A., Leitritz, M., Janzen, J., Kopp, A. F., Herdeg, C., Heuschmid, M., Burgstahler, C., Baumbach, A., Wehrmann, M., et al. (2004) · Journal of Computer Assisted Tomography · doi:10.1097/00004728-200407000-00003 · Cited by 183
Relationship between Noise, Dose, and Pitch in Cardiac Multi–Detector Row CT
Primak, A. N., McCollough, C. H., Bruesewitz, M. R., Zhang, J., & Fletcher, J. G. (2006) · RadioGraphics · doi:10.1148/rg.266065063 · Cited by 180
Self-citationAchenbach, S., Ropers, D., Pohle, F.-K., Raaz, D., von Erffa, J., Yilmaz, A., Muschiol, G., & Daniel, W. G. (2005) · European Heart Journal · doi:10.1093/eurheartj/ehi326 · Cited by 172
McCollough, C. H., Bruesewitz, M. R., McNitt‐Gray, M. F., Bush, K., Ruckdeschel, T., Payne, J. T., Brink, J. A., & Zeman, R. K. (2004) · Medical Physics · doi:10.1118/1.1769632 · Cited by 170
Self-citationOptimization of CT radiation dose: Insight into DLP and CTDI
Arfat, M., Haq, A., Beg, T., & Jaleel, G. (2024) · Future Health · doi:10.25259/fh_45_2024 · Cited by 10
Metadata
- Authors
- Morin, R. L., Gerber, T. C., & McCollough, C. H.
- Venue
- Circulation
- Published
- 2003-02-18
- Volume
- 107
- Issue
- 6
- Pages
- 917-922
- ISSN
- 0009-7322 (ISSN-L)
- 1524-4539
- OpenAlex
- W1989483631
- Cited by
- 457
- References
- 18
- FWCI
- 33.11
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.