CoChat

Improved Left Ventricular Mechanics From Acute VDD Pacing in Patients With Dilated Cardiomyopathy and Ventricular Conduction Delay

Open access
Kass, David A., Chen, Chen-Huan, Curry, Cecilia, Talbot, Maurice, Berger, Ronald, Fetics, Barry, Nevo, Erez · 1999 · Circulation
Cited by 972

The DOI matches its Crossref record; 16 of the 16 references it cites were found in a registry or an index.

Abstract

Background —Ventricular pacing can improve hemodynamics in heart failure patients, but direct effects on left ventricular (LV) function from varying pacing site and atrioventricular (AV) delay remain unknown. We hypothesized that the magnitude and location of basal intraventricular conduction delay critically influences pacing responses and that single-site pacing in the delay-activated region yields similar or better responses to biventricular pacing. Methods and Results —Aortic and LV pressures were measured in 18 heart failure patients (mean±SD: LV ejection fraction, 19±7%; LV end-diastolic pressure, 25±8 mm Hg; QRS duration, 157±36 ms). Data under normal sinus rhythm were compared with ventricular pacing (VDD) at varying sites and AV delays (randomized order). Right ventricular (RV) apical or midseptal pacing had negligible contractile/systolic effects. However, LV free-wall pacing raised dP/dt max by 23.7±19.0% and pulse-pressure by 18.0±18.4% ( P <0.01). Biventricular pacing yielded less change (+12.8±9.3% in dP/dt max , P <0.05 versus LV). Pressure-volume analysis performed in 11 patients consistently revealed minimal changes with RV pacing but increased stroke work and lower end-systolic volumes with LV pacing. Optimal AV intervals averaged 125±49 ms, and within this range, AV delay had less influence on LV function than pacing site. Basal QRS duration positively correlated with %ΔdP/dt max ( P <0.005), but pacing efficacy was not associated with QRS narrowing. Conduction delay pattern generally predicted pacing sites with most effect. Conclusions —VDD pacing acutely enhances contractile function in heart failure patients with intraventricular conduction delay. Single-site pacing at the site of greatest delay achieves similar or greater benefits to biventricular pacing in such patients. These data clarify pacing-effect mechanisms and should help in candidate identification for future studies.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/01.cir.99.12.1567

Cites

16 of 16 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 16 references

Cited by

Metadata

Authors
Kass, D. A., Chen, C.-H., Curry, C., Talbot, M., Berger, R., Fetics, B., & Nevo, E.
Venue
Circulation
Published
1999-03-30
Volume
99
Issue
12
Pages
1567-1573
ISSN
  • 0009-7322 (ISSN-L)
  • 1524-4539
OpenAlex
W2015697923
Cited by
972
References
16
FWCI
43.00
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.