The Hydrodynamically Relevant Endothelial Cell Glycocalyx Observed In Vivo Is Absent In Vitro
The DOI matches its Crossref record; 31 of the 31 references it cites were found in a registry or an index.
Abstract
In recent years, the endothelial cell surface glycocalyx has emerged as a structure of fundamental importance to a broad range of phenomena that determine cardiovascular health and disease. This new understanding of the functional significance of the glycocalyx has been made possible through recently developed experimental techniques using intravital microscopy that are capable of directly probing the glycocalyx in vivo. Using fluorescent microparticle image velocimetry in venules and endothelialized cylindrical collagen microchannels, we show that the hydrodynamically relevant endothelial cell glycocalyx surface layer observed in microvessels in vivo (0.52±0.28 μm thickness), which is a fundamental determinant of the hydrodynamic and mechanical environment at the endothelial cell surface, is absent from human umbilical vein (0.03±0.04 μm thickness) and bovine aortic (0.02±0.04 μm thickness) endothelial cells grown and maintained under standard cell culture conditions in vitro. An endothelial surface–bound glycosaminoglycan layer, not necessarily indicative of but having similar hydrodynamic properties to the endothelial glycocalyx observed in vivo, was detected (0.21±0.27 μm thickness) only after hyaluronan and chondroitin sulfate were added to the cell culture media at hyperphysiological concentrations (0.2 mg/mL perfused for 75 minutes). The implications of this glycocalyx deficiency under standard cell culture conditions in these pervasive in vitro models broadly impact a myriad of studies involving endothelial cell monolayers in which inferences are made that may depend on endothelial cell surface chemistry. In light of these findings, conclusions drawn from such studies in the areas of microvascular permeability, inflammation, mechanotransduction, and atherosclerosis must be carefully reconsidered.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A mechanosensory complex that mediates the endothelial cell response to fluid shear stress
Tzima, E., Irani-Tehrani, M., Kiosses, W. B., Dejana, E., Schultz, D. A., Engelhardt, B., Cao, G., DeLisser, H., & Schwartz, M. A. (2005) · Nature · doi:10.1038/nature03952 · Cited by 1,711
The Structure and Function of the Endothelial Glycocalyx Layer
Weinbaum, S., Tarbell, J. M., & Damiano, E. R. (2007) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.9.060906.151959 · Cited by 1,198
Self-citationTopper, J. N., Cai, J., Falb, D., & Gimbrone, M. A. (1996) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.93.19.10417 · Cited by 843
Yang, L., Froio, R. M., Sciuto, T. E., Dvorak, A. M., Alon, R., & Luscinskas, F. W. (2005) · Blood · doi:10.1182/blood-2004-12-4942 · Cited by 721
Heparan Sulfate Proteoglycan Is a Mechanosensor on Endothelial Cells
Florian, J. A., Kosky, J. R., Ainslie, K., Pang, Z., Dull, R. O., & Tarbell, J. M. (2003) · Circulation Research · doi:10.1161/01.res.0000101744.47866.d5 · Cited by 615
Vink, H., & Duling, B. R. (1996) · Circulation Research · doi:10.1161/01.res.79.3.581 · Cited by 615
Mechanotransduction and flow across the endothelial glycocalyx
Weinbaum, S., Zhang, X., Han, Y., Vink, H., & Cowin, S. C. (2003) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1332808100 · Cited by 579
Sequential contribution of L- and P-selectin to leukocyte rolling in vivo.
Ley, K., Bullard, D. C., Arbonés, M. L., Bosse, R., Vestweber, D., Tedder, T. F., & Beaudet, A. L. (1995) · The Journal of experimental medicine · doi:10.1084/jem.181.2.669 · Cited by 574
Formation of perfused, functional microvascular tubes in vitro
Chrobak, K. M., Potter, D. R., & Tien, J. (2006) · Microvascular Research · doi:10.1016/j.mvr.2006.02.005 · Cited by 553 · cited 2×
“2 In the case of full-field μ-PIV, estimated fluid-particle velocities were fit with a function of the form vfit(r) = vmax ( 2 G(α)− ∫ α r/R f(σ) dσ )( 2 G(α)− ∫ α 0 f(σ) dσ )−1 , 0 < r/R < α (1) using the fitting function f(r) = (r/R)(1−c1 sinh(c2 α))+α c1 sinh(c2 r/R), where α = a/R, c1 and c2 are constants found th…”
BackgroundSelf-citationThe Endothelial Glycocalyx Protects Against Myocardial Edema
van den Berg, B. M., Vink, H., & Spaan, J. A. E. (2003) · Circulation Research · doi:10.1161/01.res.0000065917.53950.75 · Cited by 531
FLOW THROUGH INTERSTITIUM AND OTHER FIBROUS MATRICES
Levick, J. R. (1987) · Quarterly Journal of Experimental Physiology · doi:10.1113/expphysiol.1987.sp003085 · Cited by 480
Permeation of the luminal capillary glycocalyx is determined by hyaluronan
Henry, C. B. S., & Duling, B. R. (1999) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.1999.277.2.h508 · Cited by 426
McCormick, S. M., Eskin, S. G., McIntire, L. V., Teng, C. L., Lu, C.-M., Russell, C. G., & Chittur, K. K. (2001) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.171259298 · Cited by 385
Inflammation- and ischemia-induced shedding of venular glycocalyx
Mulivor, A. W., & Lipowsky, H. H. (2004) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.00832.2003 · Cited by 382
Gautam, N., Maria Olofsson, A., Herwald, H., Iversen, L. F., Lundgren-Åkerlund, E., Hedqvist, P., Arfors, K.-E., Flodgaard, H., & Lindbom, L. (2001) · Nature Medicine · doi:10.1038/nm1001-1123 · Cited by 362
Role of glycocalyx in leukocyte-endothelial cell adhesion
Mulivor, A. W., & Lipowsky, H. H. (2002) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.00117.2002 · Cited by 328
Thi, M. M., Tarbell, J. M., Weinbaum, S., & Spray, D. C. (2004) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0407474101 · Cited by 325
TNF-α increases entry of macromolecules into luminal endothelial cell glycocalyx
Henry, C. B. S., & Duling, B. R. (2000) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.2000.279.6.h2815 · Cited by 325
Oncotic pressures opposing filtration across non‐fenestrated rat microvessels
Adamson, R. H., Lenz, J. F., Zhang, X., Adamson, G. N., Weinbaum, S., & Curry, F. E. (2004) · The Journal of Physiology · doi:10.1113/jphysiol.2003.058255 · Cited by 323
Squire, J. M., Chew, M., Nneji, G., Neal, C., Barry, J., & Michel, C. (2001) · Journal of Structural Biology · doi:10.1006/jsbi.2002.4441 · Cited by 284
Reactive oxygen species mediate modification of glycocalyx during ischemia-reperfusion injury
Rubio-Gayosso, I., Platts, S. H., & Duling, B. R. (2006) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.00796.2005 · Cited by 262
Surapisitchat, J., Hoefen, R. J., Pi, X., Yoshizumi, M., Yan, C., & Berk, B. C. (2001) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.101134098 · Cited by 225
Yao, Y., Rabodzey, A., & Dewey, C. F. (2007) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.00162.2007 · Cited by 222
Near-Wall μ-PIV Reveals a Hydrodynamically Relevant Endothelial Surface Layer in Venules In Vivo
Smith, M. L., Long, D. S., Damiano, E. R., & Ley, K. (2003) · Biophysical Journal · doi:10.1016/s0006-3495(03)74507-x · Cited by 214
Self-citationLong, D. S., Smith, M. L., Pries, A. R., Ley, K., & Damiano, E. R. (2004) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0402937101 · Cited by 210
Self-citationTheriault, A., Chao, J.-T., & Gapor, A. (2002) · Atherosclerosis · doi:10.1016/s0021-9150(01)00540-8 · Cited by 128
Effect of the endothelial surface layer on transmission of fluid shear stress to endothelial cells
Secomb, T. W., Hsu, R., & Pries, A. R. (2001) · Biorheology · doi:10.1177/0006355x2001038002003008 · Cited by 117
Damiano, E. R., Duling, B. R., Ley, K. F., & Skalak, T. C. (1996) · Journal of Fluid Mechanics · doi:10.1017/s0022112096000274 · Cited by 96
Self-citationJacob, M., Rehm, M., Loetsch, M., Paul, J. O., Bruegger, D., WELSCH, U. N., Conzen, P. F., & Becker, B. F. (2007) · Journal of Vascular Research · doi:10.1159/000104871 · Cited by 89
Platts, S. H., Linden, J. M., & Duling, B. R. (2003) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.00899.2002 · Cited by 87
Adenosine A 3 Receptor Activation Modulates the Capillary Endothelial Glycocalyx
Platts, S. H., & Duling, B. R. (2003) · Circulation Research · doi:10.1161/01.res.0000108262.35847.60 · Cited by 73
Cited by
Chiu, J.-J., & Chien, S. (2011) · Physiological Reviews · doi:10.1152/physrev.00047.2009 · Cited by 2,280
“Endothelial glycocalyx, a carbohydrate-rich layer that is a network of membrane-bound proteoglycans and glycoproteins lining the luminal side of endothelium, may serve as a mechanosensor to transmit mechanical forces into biochemical signals in ECs (181, 470, 608, 610, 635).”
BackgroundSchmidt, E. P., Yang, Y., Janssen, W. J., Gandjeva, A., Perez, M. J., Barthel, L., Zemans, R. L., Bowman, J. C., Koyanagi, D. E., Yunt, Z. X., et al. (2012) · Nature Medicine · doi:10.1038/nm.2843 · Cited by 848
Therapeutic strategies targeting the endothelial glycocalyx: acute deficits, but great potential
Becker, B. F., Chappell, D., Bruegger, D., Annecke, T., & Jacob, M. (2010) · Cardiovascular Research · doi:10.1093/cvr/cvq137 · Cited by 438
Endothelial Glycocalyx: Permeability Barrier and Mechanosensor
Curry, F. E., & Adamson, R. H. (2012) · Annals of Biomedical Engineering · doi:10.1007/s10439-011-0429-8 · Cited by 312
Endothelial glycocalyx and coronary vascular permeability: the fringe benefit
Becker, B. F., Chappell, D., & Jacob, M. (2010) · Basic Research in Cardiology · doi:10.1007/s00395-010-0118-z · Cited by 277
Metadata
- Authors
- Potter, D. R., & Damiano, E. R.
- Venue
- Circulation Research
- Published
- 2008-04-11
- Volume
- 102
- Issue
- 7
- Pages
- 770-776
- ISSN
- 0009-7330 (ISSN-L)
- 1524-4571
- OpenAlex
- W2101685062
- Cited by
- 173
- References
- 31
- FWCI
- 6.44
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.