The Hydrodynamically Relevant Endothelial Cell Glycocalyx Observed In Vivo Is Absent In Vitro
The DOI matches its Crossref record; 31 of the 31 references it cites were found in a registry or an index.
Abstract
In recent years, the endothelial cell surface glycocalyx has emerged as a structure of fundamental importance to a broad range of phenomena that determine cardiovascular health and disease. This new understanding of the functional significance of the glycocalyx has been made possible through recently developed experimental techniques using intravital microscopy that are capable of directly probing the glycocalyx in vivo. Using fluorescent microparticle image velocimetry in venules and endothelialized cylindrical collagen microchannels, we show that the hydrodynamically relevant endothelial cell glycocalyx surface layer observed in microvessels in vivo (0.52±0.28 μm thickness), which is a fundamental determinant of the hydrodynamic and mechanical environment at the endothelial cell surface, is absent from human umbilical vein (0.03±0.04 μm thickness) and bovine aortic (0.02±0.04 μm thickness) endothelial cells grown and maintained under standard cell culture conditions in vitro. An endothelial surface–bound glycosaminoglycan layer, not necessarily indicative of but having similar hydrodynamic properties to the endothelial glycocalyx observed in vivo, was detected (0.21±0.27 μm thickness) only after hyaluronan and chondroitin sulfate were added to the cell culture media at hyperphysiological concentrations (0.2 mg/mL perfused for 75 minutes). The implications of this glycocalyx deficiency under standard cell culture conditions in these pervasive in vitro models broadly impact a myriad of studies involving endothelial cell monolayers in which inferences are made that may depend on endothelial cell surface chemistry. In light of these findings, conclusions drawn from such studies in the areas of microvascular permeability, inflammation, mechanotransduction, and atherosclerosis must be carefully reconsidered.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A mechanosensory complex that mediates the endothelial cell response to fluid shear stress
Tzima, E., Irani-Tehrani, M., Kiosses, W. B., Dejana, E., Schultz, D. A., Engelhardt, B., Cao, G., DeLisser, H., & Schwartz, M. A. (2005) · Nature · doi:10.1038/nature03952 · Cited by 1,711
The Structure and Function of the Endothelial Glycocalyx Layer
Weinbaum, S., Tarbell, J. M., & Damiano, E. R. (2007) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.9.060906.151959 · Cited by 1,198
Self-citationTopper, J. N., Cai, J., Falb, D., & Gimbrone, M. A. (1996) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.93.19.10417 · Cited by 843
Yang, L., Froio, R. M., Sciuto, T. E., Dvorak, A. M., Alon, R., & Luscinskas, F. W. (2005) · Blood · doi:10.1182/blood-2004-12-4942 · Cited by 721
Heparan Sulfate Proteoglycan Is a Mechanosensor on Endothelial Cells
Florian, J. A., Kosky, J. R., Ainslie, K., Pang, Z., Dull, R. O., & Tarbell, J. M. (2003) · Circulation Research · doi:10.1161/01.res.0000101744.47866.d5 · Cited by 615
Vink, H., & Duling, B. R. (1996) · Circulation Research · doi:10.1161/01.res.79.3.581 · Cited by 615
Mechanotransduction and flow across the endothelial glycocalyx
Weinbaum, S., Zhang, X., Han, Y., Vink, H., & Cowin, S. C. (2003) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1332808100 · Cited by 579
Sequential contribution of L- and P-selectin to leukocyte rolling in vivo.
Ley, K., Bullard, D. C., Arbonés, M. L., Bosse, R., Vestweber, D., Tedder, T. F., & Beaudet, A. L. (1995) · The Journal of experimental medicine · doi:10.1084/jem.181.2.669 · Cited by 574
Formation of perfused, functional microvascular tubes in vitro
Chrobak, K. M., Potter, D. R., & Tien, J. (2006) · Microvascular Research · doi:10.1016/j.mvr.2006.02.005 · Cited by 553 · cited 2×
“2 In the case of full-field μ-PIV, estimated fluid-particle velocities were fit with a function of the form vfit(r) = vmax ( 2 G(α)− ∫ α r/R f(σ) dσ )( 2 G(α)− ∫ α 0 f(σ) dσ )−1 , 0 < r/R < α (1) using the fitting function f(r) = (r/R)(1−c1 sinh(c2 α))+α c1 sinh(c2 r/R), where α = a/R, c1 and c2 are constants found th…”
BackgroundSelf-citationThe Endothelial Glycocalyx Protects Against Myocardial Edema
van den Berg, B. M., Vink, H., & Spaan, J. A. E. (2003) · Circulation Research · doi:10.1161/01.res.0000065917.53950.75 · Cited by 531
Cited by
Chiu, J.-J., & Chien, S. (2011) · Physiological Reviews · doi:10.1152/physrev.00047.2009 · Cited by 2,280
“Endothelial glycocalyx, a carbohydrate-rich layer that is a network of membrane-bound proteoglycans and glycoproteins lining the luminal side of endothelium, may serve as a mechanosensor to transmit mechanical forces into biochemical signals in ECs (181, 470, 608, 610, 635).”
BackgroundSchmidt, E. P., Yang, Y., Janssen, W. J., Gandjeva, A., Perez, M. J., Barthel, L., Zemans, R. L., Bowman, J. C., Koyanagi, D. E., Yunt, Z. X., et al. (2012) · Nature Medicine · doi:10.1038/nm.2843 · Cited by 848
Therapeutic strategies targeting the endothelial glycocalyx: acute deficits, but great potential
Becker, B. F., Chappell, D., Bruegger, D., Annecke, T., & Jacob, M. (2010) · Cardiovascular Research · doi:10.1093/cvr/cvq137 · Cited by 438
Endothelial Glycocalyx: Permeability Barrier and Mechanosensor
Curry, F. E., & Adamson, R. H. (2012) · Annals of Biomedical Engineering · doi:10.1007/s10439-011-0429-8 · Cited by 312
Endothelial glycocalyx and coronary vascular permeability: the fringe benefit
Becker, B. F., Chappell, D., & Jacob, M. (2010) · Basic Research in Cardiology · doi:10.1007/s00395-010-0118-z · Cited by 277
Davis, M. J., Earley, S., Li, Y.-S., & Chien, S. (2023) · Physiological Reviews · doi:10.1152/physrev.00053.2021 · Cited by 273
Loss of the Endothelial Glycocalyx Links Albuminuria and Vascular Dysfunction
Salmon, A. H. J., Ferguson, J. K., Burford, J. L., Gevorgyan, H., Nakano, D., Harper, S. J., Bates, D. O., & Peti-Peterdi, J. (2012) · Journal of the American Society of Nephrology · doi:10.1681/asn.2012010017 · Cited by 267
Modulation of Endothelial Glycocalyx Structure under Inflammatory Conditions
Kolářová, H., Ambrůzová, B., Švihálková Šindlerová, L., Klinke, A., & Kubala, L. (2014) · Mediators of Inflammation · doi:10.1155/2014/694312 · Cited by 257
Damage of the endothelial glycocalyx in chronic kidney disease
Padberg, J.-S., Wiesinger, A., di Marco, G. S., Reuter, S., Grabner, A., Kentrup, D., Lukasz, A., Oberleithner, H., Pavenstädt, H., Brand, M., et al. (2014) · Atherosclerosis · doi:10.1016/j.atherosclerosis.2014.03.016 · Cited by 241
Ebong, E. E., Macaluso, F. P., Spray, D. C., & Tarbell, J. M. (2011) · Arteriosclerosis, Thrombosis, and Vascular Biology · doi:10.1161/atvbaha.111.225268 · Cited by 237
“…No fixation Fluorescent microspheres in medium HUVEC¶ 0.03 Potter and Damiano (2008)8 -PIV No fixation Fluorescent microspheres in medium BAEC 0.02 Potter and Damiano (2008)8 TEM Glut Lanthanum HUVEC 0.03 Chappell et al. (2009)7 TEM Glut RR BAEC 0.02 to 0.04 Ueda et al. (2004)10 TEM Glut…”
BackgroundInfluentialvan Golen, R. F., van Gulik, T. M., & Heger, M. (2012) · Free Radical Biology and Medicine · doi:10.1016/j.freeradbiomed.2012.01.013 · Cited by 221
Chappell, D., Jacob, M., Paul, O., Rehm, M., Welsch, U., Stoeckelhuber, M., Conzen, P., & Becker, B. F. (2009) · Circulation Research · doi:10.1161/circresaha.108.187831 · Cited by 218
“15 The uncertainty arises in part from (1) differences in the technique applied to estimate the dimension (eg, indirect measurement of exclusion zones for blood cells as opposed to fluorescent tracers; calculations based on flow resistance measurements and optical vessel width; ex vivo determinations after fixation by…”
MethodPrice, G. M., Wong, K. H. K., Truslow, J. G., Leung, A. D., Acharya, C., & Tien, J. (2010) · Biomaterials · doi:10.1016/j.biomaterials.2010.04.041 · Cited by 184
“The discordant effects of increased shear in vivo and in vitro suggest that nitricoxide release is largelyabsent inour tubes; this explanation is consistent with the reported lack of glycocalyx in vitro, a structure that is required for shear stress-inducedreleaseofnitric oxide [44,45].”
Gao, L., & Lipowsky, H. H. (2010) · Microvascular Research · doi:10.1016/j.mvr.2010.06.005 · Cited by 182
“A similar loss of δ in response to infusion of hyaluronidase was inferred by the indirect technique of particle image velocimetry by extrapolation of venular velocity profiles in cremaster muscle (Potter and Damiano, 2008).”
Lipowsky, H. H. (2012) · Annals of Biomedical Engineering · doi:10.1007/s10439-011-0427-x · Cited by 180
Mechanosensing at the Vascular Interface
Tarbell, J. M., Simon, S. I., & Curry, F.-R. E. (2014) · Annual Review of Biomedical Engineering · doi:10.1146/annurev-bioeng-071813-104908 · Cited by 180
Dogné, S., Flamion, B., & Caron, N. (2018) · Arteriosclerosis, Thrombosis, and Vascular Biology · doi:10.1161/atvbaha.118.310839 · Cited by 177
The Recovery Time Course of the Endothelial Cell Glycocalyx In Vivo and Its Implications In Vitro
Potter, D. R., Jiang, J., & Damiano, E. R. (2009) · Circulation Research · doi:10.1161/circresaha.108.191585 · Cited by 176
Self-citationNanomechanics of the Endothelial Glycocalyx in Experimental Sepsis
Wiesinger, A., Peters, W., Chappell, D., Kentrup, D., Reuter, S., Pavenstädt, H., Oberleithner, H., & Kümpers, P. (2013) · PLoS ONE · doi:10.1371/journal.pone.0080905 · Cited by 170
“limitations of in vivo visualization methods probably impede any direct comparison of glycocalyx dimensions, we noted that this value was compatible with many of the aforementioned reports [19,39,44].”
ResultThe cell-free layer in microvascular blood flow
Kim, S., Ong, P. K., Yalcin, O., Intaglietta, M., & Johnson, P. C. (2009) · Biorheology · doi:10.3233/bir-2009-0530 · Cited by 159
“Recent studies [35,43] by Damiano and coworkers report that this glycocalyx layer is slightly thinner ( ∼ 0.4 µm) in arterioles (ID 20–70 µm) than venules.”
Influential
Metadata
- Authors
- Potter, D. R., & Damiano, E. R.
- Venue
- Circulation Research
- Published
- 2008-04-11
- Volume
- 102
- Issue
- 7
- Pages
- 770-776
- ISSN
- 0009-7330 (ISSN-L)
- 1524-4571
- OpenAlex
- W2101685062
- Cited by
- 173
- References
- 31
- FWCI
- 6.44
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.