The DOI matches its Crossref record; 74 of the 74 references it cites were found in a registry or an index.
Reference intervals: current status, recent developments and future considerations
Open accessAbstract
Reliable and accurate reference intervals (RIs) for laboratory analyses are an integral part of the process of correct interpretation of clinical laboratory test results. RIs given in laboratory reports have an important role in aiding the clinician in interpreting test results in reference to values for healthy populations. Since the 1980s, the International Federation of Clinical Chemistry (IFCC) has been proactive in establishing recommendations to clarify the true significance of the term 'RIs, to select the appropriate reference population and statistically analyse the data. The C28-A3 guideline published by the Clinical and Laboratory Standards Institute (CLSI) and IFCC is still the most widely-used source of reference in this area. In recent years, protocols additional to the Guideline have been published by the IFCC, Committee on Reference Intervals and Decision Limits (C-RIDL), including all details of multicenter studies on RIs to meet the requirements in this area. Multicentric RIs studies are the most important development in the area of RIs. Recently, the C-RIDL has performed many multicentric studies to obtain common RIs. Confusion of RIs and clinical decision limits (CDLs) remains an issue and pediatric and geriatric age groups are a significant problem. For future studies of RIs, the genetic effect would seem to be the most challenging area. The aim of the review is to present the current theory and practice of RIs, with special emphasis given to multicenter RIs studies, RIs studies for pediatric and geriatric age groups, clinical decision limits and partitioning by genetic effects on RIs.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Yaşlı Kadınlarda Üreme Sağlığı
Kokanalı, D., & Engin Üstün, Y. (n.d.) · DergiPark (Istanbul University) · Cited by 170,090
Toprak, O., Kurt, H., Sarı, Y., Şarkış, C., Us, H., & Kırık, A. (2017) · Kidney and Blood Pressure Research · doi:10.1159/000468530 · Cited by 29,627
Grundy, S. M., Bilheimer, D. W., Chait, A., Clark, L. T., Denke, M. A., Havel, R. J., Hazzard, W. R., Hulley, S. B., Hunninghake, D. B., Kreisberg, R. A., et al. (1993) · JAMA · doi:10.1001/jama.269.23.3015 · Cited by 27,947
Expert Panel on Detection, E. (2001) · JAMA: The Journal of the American Medical Association · doi:10.1001/jama.285.19.2486 · Cited by 26,011
An Analysis of Transformations
Box, G. E. P., & Cox, D. R. (1964) · Journal of the Royal Statistical Society Series B: Statistical Methodology · doi:10.1111/j.2517-6161.1964.tb00553.x · Cited by 15,052
David, F. N., & Tukey, J. W. (1977) · Biometrics · doi:10.2307/2529486 · Cited by 12,708
International Organization for Standardization
(2011) · SpringerReference · doi:10.1007/springerreference_16847 · Cited by 12,534
The Jackknife, the Bootstrap and Other Resampling Plans
Efron, B. (1982) · Society for Industrial and Applied Mathematics eBooks · doi:10.1137/1.9781611970319 · Cited by 8,120
Birch, J. B., & Tukey, J. W. (1978) · Journal of the American Statistical Association · doi:10.2307/2286300 · Cited by 1,440
A Simple Method of Resolution of a Distribution into Gaussian Components
Bhattacharya, C. G. (1967) · Biometrics · doi:10.2307/2528285 · Cited by 1,210
Generation and Application of Data on Biological Variation in Clinical Chemistry
Fraser, G. G., & Harris, E. K. (1989) · Critical Reviews in Clinical Laboratory Sciences · doi:10.3109/10408368909106595 · Cited by 870
Dixon, W. J. (1953) · Biometrics · doi:10.2307/3001634 · Cited by 868
Influence of Statistical Method Used on the Resulting Estimate of Normal Range
Reed, A. H., Henry, R. J., & Mason, W. B. (1971) · Clinical Chemistry · doi:10.1093/clinchem/17.4.275 · Cited by 531
Reference intervals: an update
Horn, P. S., & Pesce, A. J. (2003) · Clinica Chimica Acta · doi:10.1016/s0009-8981(03)00133-5 · Cited by 412
Rustad, P., Felding, P., Franzson, L., Kairisto, V., Lahti, A., Mårtensson, A., Petersen, P. H., Simonsson, P., Steensland, H., & Uldall, A. (2004) · Scandinavian Journal of Clinical and Laboratory Investigation · doi:10.1080/00365510410006324 · Cited by 404
Solberg, H. E. (1987) · Clinica Chimica Acta · doi:10.1016/0009-8981(87)90151-3 · Cited by 395
On dividing reference data into subgroups to produce separate reference ranges
Harris, E. K., & Boyd, J. C. (1990) · Clinical Chemistry · doi:10.1093/clinchem/36.2.265 · Cited by 379
Effects of Intra-and Interindividual Variation on the Appropriate Use of Normal Ranges
Harris, E. K. (1974) · Clinical Chemistry · doi:10.1093/clinchem/20.12.1535 · Cited by 324
Effect of Outliers and Nonhealthy Individuals on Reference Interval Estimation
Horn, P. S., Feng, L., Li, Y., & Pesce, A. J. (2001) · Clinical Chemistry · doi:10.1093/clinchem/47.12.2137 · Cited by 301
A robust approach to reference interval estimation and evaluation
Horn, P. S., Pesce, A. J., & Copeland, B. E. (1998) · Clinical Chemistry · doi:10.1093/clinchem/44.3.622 · Cited by 272
Risk factors and cardiovascular disease in Turkey
Onat, A. (2001) · Atherosclerosis · doi:10.1016/s0021-9150(01)00500-7 · Cited by 252
Ceriotti, F., Boyd, J. C., Klein, G., Henny, J., Queraltó, J., Kairisto, V., Panteghini, M., & the IFCC Committee on Reference Intervals and Decision Limits (C-RIDL) (2008) · Clinical Chemistry · doi:10.1373/clinchem.2007.099648 · Cited by 252
Preanalytical quality improvement: in quality we trust
Lippi, G., Becan-McBride, K., Behúlová, D., Bowen, R. A., Church, S., Delanghe, J., Grankvist, K., Kitchen, S., Nybo, M., Nauck, M., et al. (2013) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2012-0597 · Cited by 236
Solberg, H. E. (1987) · Clinica Chimica Acta · doi:10.1016/0009-8981(87)90224-5 · Cited by 222
Inherent biological variation and reference values
Fraser, C. G. (2004) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm.2004.128 · Cited by 222
An appraisal of statistical procedures used in derivation of reference intervals
Ichihara, K., & Boyd, J. C. (2010) · cclm · doi:10.1515/cclm.2010.319 · Cited by 213
Reference intervals: the way forward
Ceriotti, F., Hinzmann, R., & Panteghini, M. (2009) · Annals of Clinical Biochemistry: International Journal of Laboratory Medicine · doi:10.1258/acb.2008.008170 · Cited by 199
Adeli, K., Raizman, J. E., Chen, Y., Higgins, V., Nieuwesteeg, M., Abdelhaleem, M., Wong, S. L., & Blais, D. (2015) · Clinical Chemistry · doi:10.1373/clinchem.2015.240531 · Cited by 185
Defining Cerebrospinal Fluid White Blood Cell Count Reference Values in Neonates and Young Infants
Kestenbaum, L. A., Ebberson, J., Zorc, J. J., Hodinka, R. L., & Shah, S. S. (2010) · Pediatrics · doi:10.1542/peds.2009-1181 · Cited by 168
Medical laboratories. Requirements for quality and competence
(2013) · doi:10.3403/30173019 · Cited by 167
Lippi, G., Banfi, G., Church, S., Cornes, M. P., Carli, G. D., Grankvist, K., Kristensen, G. B. B., Ibarz, M., Panteghini, M., Plebani, M., et al. (2014) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2014-1051 · Cited by 157
Laboratory reference intervals during pregnancy, delivery and the early postpartum period
Klajnbard, A., Szecsi, P. B., Colov, N. P., Andersen, M. R., Jørgensen, M., Bjørngaard, B., Barfoed, A., Haahr, K., & Stender, S. (2009) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm.2010.033 · Cited by 142
Petitclerc, C., & Solberg, H. E. (1987) · Clinica Chimica Acta · doi:10.1016/0009-8981(87)90150-1 · Cited by 141
Harmonization of pre-analytical quality indicators
Plebani, M., Sciacovelli, L., Aita, A., & Chiozza, M. L. (2014) · Biochemia Medica · doi:10.11613/bm.2014.012 · Cited by 127
Ceriotti, F., Henny, J., Queraltó, J. M., Ziyu, S., Özarda, Y., Chen, B., Boyd, J. C., & Panteghini, M. (2010) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm.2010.315 · Cited by 126
Partitioning of Nongaussian-Distributed Biochemical Reference Data into Subgroups
Lahti, A., Petersen, P. H., Boyd, J. C., Rustad, P., Laake, P., & Solberg, H. E. (2004) · Clinical Chemistry · doi:10.1373/clinchem.2003.027953 · Cited by 125
The theory of reference values: an unfinished symphony
Siest, G., Henny, J., Gräsbeck, R., Wilding, P. M., Petitclerc, C., Queraltó, J. M., & Petersen, P. H. (2012) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2012-0682 · Cited by 121
Estey, M. P., Cohen, A. H., Colantonio, D., Chan, M. K., Marvasti, T. B., Randell, E. W., DELVIN, E. E., Cousineau, J., Grey, V., Greenway, D. C., et al. (2013) · Clinical Biochemistry · doi:10.1016/j.clinbiochem.2013.04.001 · Cited by 111
Solberg, H. E., & Petitclerc, C. (1988) · Clinica Chimica Acta · doi:10.1016/0009-8981(88)90074-5 · Cited by 109
Özarda, Y., Ichihara, K., Barth, J. H., & Klee, G. G. (2013) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2013-0249 · Cited by 109
Clinical laboratory reference intervals in pediatrics: The CALIPER initiative
Jung, B., & Adeli, K. (2009) · Clinical Biochemistry · doi:10.1016/j.clinbiochem.2009.06.025 · Cited by 103
Nordin, G., Mårtensson, A., Swolin, B., Sandberg, S., Christensen, N. J., Thorsteinsson, V., Franzson, L., Kairisto, V., & Savolainen, E. (2004) · Scandinavian Journal of Clinical and Laboratory Investigation · doi:10.1080/00365510410002797 · Cited by 98
The REALAB Project: A New Method for the Formulation of Reference Intervals Based on Current Data
Grossi, E., Colombo, R., Cavuto, S., & Franzini, C. (2005) · Clinical Chemistry · doi:10.1373/clinchem.2005.047787 · Cited by 94
Tate, J. R., Sikaris, K. A., Jones, G. R. D., Yen, T., Koerbin, G., Ryan, J. E., Reed, M., Gill, J., Koumantakis, G., Hickman, P. E., et al. (2014) · Europe PMC (PubMed Central) · Cited by 87
Need for Revisiting the Concept of Reference Values
Henny, J., Petitclerc, C., Fuentes‐Arderiu, X., Petersen, P. H., Queraltó, J. M., Schiele, F., & Siest, G. (2000) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm.2000.085 · Cited by 87
Dybkœr, R., & Solberg, H. E. (1987) · Clinica Chimica Acta · doi:10.1016/0009-8981(87)90152-5 · Cited by 87
Prerequisites for use of common reference intervals.
Ceriotti, F. (2007) · PubMed · Cited by 82
Bersot, T. P., Vega, G. L., Grundy, S. M., Palaoğlu, K. E., Atagündüz, P., Özbayrakçı, S., Gökdemir, O., & Mahley, R. W. (1999) · Journal of Lipid Research · doi:10.1016/s0022-2275(20)32447-0 · Cited by 80
Statistical considerations for harmonization of the global multicenter study on reference values
Ichihara, K. (2014) · Clinica Chimica Acta · doi:10.1016/j.cca.2014.01.025 · Cited by 78
Vincent‐Viry, M., Schiele, F., Gueguen, R., Bohnet, K., Visvikis‐Siest, S., & Siest, G. (1998) · Clinical Chemistry · doi:10.1093/clinchem/44.5.957 · Cited by 77
Shaw, J. L. V., Cohen, A. H., Konforte, D., et al. (2013) · Clinical Biochemistry · doi:10.1016/j.clinbiochem.2013.11.008 · Cited by 75
Baadenhuijsen, H., & Smit, J. C. (1985) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm.1985.23.12.829 · Cited by 72
Physiology and its importance for reference intervals.
Sikaris, K. A. (2014) · Europe PMC (PubMed Central) · Cited by 70
Ichihara, K., Ceriotti, F., Tam, T. H., Sueyoshi, S., Poon, P. M. K., Thong, M. L., Higashiuesato, Y., Wang, X., Kataoka, H., Matsubara, A., et al. (2013) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2012-0421 · Cited by 69
Closing the gaps in paediatric reference intervals: the CALIPER initiative.
Schnabl, K. L., Chan, M. K., Gong, Y., et al. (2008) · PubMed · Cited by 67
Medical Laboratories — Requirements for Quality and Competence: An ISO Perspective
Richardson, H. (2002) · Vox Sanguinis · doi:10.1111/j.1423-0410.2002.tb05329.x · Cited by 67
Impact of Subgroup Prevalences on Partitioning of Gaussian-distributed Reference Values
Lahti, A., Petersen, P. H., & Boyd, J. C. (2002) · Clinical Chemistry · doi:10.1093/clinchem/48.11.1987 · Cited by 63
Transference and Validation of Reference Intervals
Tate, J. R., Yen, T., & Jones, G. R. D. (2015) · Clinical Chemistry · doi:10.1373/clinchem.2015.243055 · Cited by 55
Özarda, Y., Ichihara, K., Aslan, D., Aybek, H., Arı, Z., Taneli, F., Çöker, C., Akan, P., Şişman, A. R., Bahceci, O., et al. (2014) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2014-0228 · Cited by 50
The case for common reference intervals.
Jones, G. R. D., Barker, A., Tate, J. R., Lim, C., & Robertson, K. (2004) · PubMed Central · Cited by 48
İlçöl, Y. Ö., & Aslan, D. (2006) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm.2006.139 · Cited by 47
Statistical criteria for separate reference intervals: race and gender groups in creatine kinase
Harris, E. K., Wong, E. T., & Shaw, S. T. (1991) · Clinical Chemistry · doi:10.1093/clinchem/37.9.1580 · Cited by 47
Ichihara, K., Ceriotti, F., Mori, K., Huang, Y.-Y., Shimizu, Y., Suzuki, H., Kitagawa, M., Yamauchi, K., Hayashi, S., Tsou, C.-C., et al. (2013) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2012-0422 · Cited by 46
Sikaris, K. A. (2012) · Europe PMC (PubMed Central) · Cited by 45
Ceriotti, F., & Henny, J. (2008) · PubMed Central · Cited by 41
Colour coding for blood collection tube closures – a call for harmonisation
Šimundić, A.-M., Cornes, M. P., Grankvist, K., Lippi, G., Nybo, M., Ceriotti, F., Theodorsson, E., & Panteghini, M. (2014) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2014-0927 · Cited by 33
Solberg, H. E., & Stamm, D. (1991) · Clinica Chimica Acta · doi:10.1016/0009-8981(91)90266-f · Cited by 30
Ichihara, K., Özarda, Y., Klee, G. G., Straseski, J. A., Baumann, N. A., & Ishikura, K. (2013) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2013-0248 · Cited by 28
Özarda, Y., Kaynak, D. S., Hizli, B., & Aslan, D. (2009) · Cell Biochemistry and Function · doi:10.1002/cbf.1610 · Cited by 26
Validating common reference intervals in routine laboratories
Jones, G. R. D. (2013) · Clinica Chimica Acta · doi:10.1016/j.cca.2013.10.005 · Cited by 26
Intraindividual reference values
Queraltó, J. M. (2004) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm.2004.129 · Cited by 23
Shahabi, P., Siest, G., Herbeth, B., Ndiaye, N. C., & Visvikis‐Siest, S. (2012) · Clinica Chimica Acta · doi:10.1016/j.cca.2012.04.033 · Cited by 18
Common reference intervals: The IFCC position
Ceriotti, F. (2009) · Clinical Biochemistry · doi:10.1016/j.clinbiochem.2008.09.017 · Cited by 18
Multicentric reference values for some quantities measured with the Elecsys 2010® analyser
Fuentes‐Arderiu, X., Ferré-Masferrer, M., González‐Alba, J. M., Villarino-González, M. I., Arrimadas-Esteban, E., Cabrero-Olivé, D., Arroyo, M. C., Garcı́a-Garcı́a, D., Garcı́a-Lario, J. V., Idoate, I., et al. (2001) · Clinica Chimica Acta · doi:10.1016/s0009-8981(00)00406-x · Cited by 17
Cited by
Performance of plasma phosphorylated tau 181 and 217 in the community
Mielke, M. M., Dage, J. L., Frank, R. D., Algeciras-Schimnich, A., Knopman, D. S., Lowe, V. J., Bu, G., Vemuri, P., Graff-Radford, J., Jack, C. R., et al. (2022) · Nature Medicine · doi:10.1038/s41591-022-01822-2 · Cited by 465
Thienpont, L. M., Van Uytfanghe, K., De Grande, L. A. C., Reynders, D., Das, B., Faix, J. D., MacKenzie, F., Decallonne, B., Hishinuma, A., Lapauw, B., et al. (2017) · Clinical Chemistry · doi:10.1373/clinchem.2016.269456 · Cited by 101
The risk of penetration–aspiration related to residue in the pharynx
Steele, C. M., Peladeau-Pigeon, M., Barrett, E., & Wolkin, T. S. (2020) · American Journal of Speech-Language Pathology · doi:10.1044/2020_ajslp-20-00042 · Cited by 57
Ni, L., Xue, P., An, C., Yu, X., Qu, J., Yao, Y., & Li, Y. (2021) · Journal of Healthcare Engineering · doi:10.1155/2021/7119779 · Cited by 48
(2018) · doi:10.3967/bes2018.011
Metadata
- Authors
- Ozarda, Y.
- Venue
- Biochemia Medica
- Published
- 2016
- Volume
- 26
- Issue
- 1
- Pages
- 5-16
- ISSN
- 1330-0962 (ISSN-L)
- 1846-7482
- OpenAlex
- W2297073812
- Cited by
- 264
- References
- 74
- FWCI
- 9.58
- Type
- journal article
- Language
- en
- Open access
- diamond
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.