The DOI matches its Crossref record; 54 of the 55 references it cites were found in a registry or an index.
Current Steering in Retinal Stimulation via a Quasimonopolar Stimulation Paradigm
Open accessAbstract
PURPOSE: Research to restore some degree of vision to patients suffering from retinal degeneration is becoming increasingly more promising. Several groups have chosen electrical stimulation of the remaining network of a degenerate retina as a means to generate discrete light percepts (phosphenes). Approaches vary significantly, with the greatest difference being the location of the stimulating electrode itself. METHODS: Suprachoroidal positioning offers excellent mechanical stability and surgical simplicity; however, at the cost of activation thresholds and focused stimulation due to the distance from the electrodes to the target neurons. Past studies proposed a hexapolar electrode configuration to focus the cortical activation and minimize cross-talk between electrodes during concurrent stimulation. The high impedance nature of the choroid and pigment epithelium, however, cause current to shunt between the stimulating and return electrodes, resulting in even higher activation thresholds. In our study, we analyzed the effect of stimulating the feline retina using a quasimonopolar stimulation by simultaneously stimulating a hexapolar and distant monopolar return configurations. RESULTS: Results of in vivo studies showed that quasimonopolar stimulation can be used to maintain the activation containment properties of hexapolar stimulation, while lowering the activation threshold to values almost equivalent to those of monopolar stimulation. CONCLUSIONS: The optimal stimulus was found to be composed of a subthreshold monopolar stimulus combined with a suprathreshold hexapolar stimulation. This resulted in a decrease of activation threshold of 60% with respect to hexapolar alone, but with no discernible deleterious effect on the charge containment of a pure hexapolar stimulation.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“For instance, current steering has been applied both in retinal implants (Dumm et al., 2014; Matteucci et al., 2013), cochlear implants (Firszt et al., 2007; Kalkman et al., 2016) and deep brain stimulators (Gross and McDougal, 2013) although it has not yet found clinical applications in the cerebral cortex.”
From Dynamic Stimulation of Visual Cortex Produces Form Vision in Sighted and Blind Humans (2020) · cites this paper as Matteucci et al., 2013
Citations
Cites
The sensations produced by electrical stimulation of the visual cortex
Brindley, G. S., & Lewin, W. S. (1968) · The Journal of Physiology · doi:10.1113/jphysiol.1968.sp008519 · Cited by 1,170
Rf, G. (1985) · Cited by 949
Wt, L., Holmquest, H. J., Scot, D., & Dow, M. (1961) · PubMed · Cited by 898
The retinotopic organization of area 17 (striate cortex) in the cat
Tusa, R. J., Palmer, L. A., & Rosenquist, A. C. (1978) · Journal of Comparative Neurology · doi:10.1002/cne.901770204 · Cited by 737 · cited 1×
“Previous studies also have indicated a correlation between retinal recruitment and cortical activation localization.(40) Recently, however, there has been evidence that the correlation does not always correspond to an equivalent increase in cortical localization.”
Rizzo, J. F., Wyatt, J., Loewenstein, J., Kelly, S., & Shire, D. (2003) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.02-0817 · Cited by 478
Dobelle, W. H., & Mladejovsky, M. G. (1974) · The Journal of Physiology · doi:10.1113/jphysiol.1974.sp010766 · Cited by 468
A neural interface for a cortical vision prosthesis
Normann, R. A., Maynard, E. M., Rousche, P. J., & Warren, D. J. (1999) · Vision Research · doi:10.1016/s0042-6989(99)00040-1 · Cited by 409
Veraart, C., Raftopoulos, C., Mortimer, J. T., Delbeke, J., Pins, D., Michaux, G., Vanlierde, A., Parrini, S., & Wanet-Defalque, M.-C. (1998) · Brain Research · doi:10.1016/s0006-8993(98)00977-9 · Cited by 405
Morphometric analysis of the extramacular retina from postmortem eyes with retinitis pigmentosa.
Humayun, M. S., Prince, M. R., de Juan, E., Barrón, Y., Moskowitz, M., Klock, I. B., & Milam, A. H. (1999) · PubMed · Cited by 366
Rose, T. L., & Robblee, L. S. (1990) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.61038 · Cited by 358
Brief, Noninjurious Electric Waveform for Stimulation of the Brain
Lilly, J. C., Hughes, J. R., Alvord, E. C., & Galkin, T. W. (1955) · Science · doi:10.1126/science.121.3144.468 · Cited by 287
Learning Retina Implants with Epiretinal Contacts
Eckmiller, R. (1997) · Ophthalmic Research · doi:10.1159/000268026 · Cited by 257
Visual Performance Using a Retinal Prosthesis in Three Subjects With Retinitis Pigmentosa
Yanai, D., Weiland, J. D., Mahadevappa, M., Greenberg, R. J., Fine, I., & Humayun, M. S. (2007) · American Journal of Ophthalmology · doi:10.1016/j.ajo.2007.01.027 · Cited by 231
Neuroprosthetics : Theory and Practice
Horch, K., & Dhillon, G. S. (2004) · doi:10.1142/4987#t=toc · Cited by 215
Single fiber mapping of spatial excitation patterns in the electrically stimulated auditory nerve
van den Honert, C., & Stypulkowski, P. H. (1987) · Hearing Research · doi:10.1016/0378-5955(87)90167-5 · Cited by 209
Auditory Cortical Images of Cochlear-Implant Stimuli: Dependence on Electrode Configuration
Bierer, J. A., & Middlebrooks, J. C. (2002) · Journal of Neurophysiology · doi:10.1152/jn.00212.2001 · Cited by 172 · cited 1×
“tion in the auditory cortex is affected by return configurations of the stimulating device.(49,50)”
BackgroundMajji, A. B., Humayun, M. S., Weiland, J. D., Suzuki, S., D’Anna, S. A., & de Juan, E. (1999) · PubMed · Cited by 172
A model for intracortical visual prosthesis research
Troyk, P., Bak, M., Berg, J., Bradley, D., Cogan, S., Erickson, R., Kufta, C., McCreery, D., Schmidt, E., & Towle, V. (2003) · Artificial Organs · doi:10.1046/j.1525-1594.2003.07308.x · Cited by 166
Active transport of ions across frog retinal pigment epithelium
Miller, S. S., & Steinberg, R. H. (1977) · Experimental Eye Research · doi:10.1016/0014-4835(77)90090-2 · Cited by 164
Auditory Prosthesis with a Penetrating Nerve Array
Middlebrooks, J. C., & Snyder, R. L. (2007) · Journal of the Association for Research in Otolaryngology · doi:10.1007/s10162-007-0070-2 · Cited by 158
Development and Implantation of a Minimally Invasive Wireless Subretinal Neurostimulator
Shire, D. B., Kelly, S. K., Chen, J., Doyle, P., Gingerich, M. D., Cogan, S. F., Drohan, W. A., Mendoza, O., Theogarajan, L. S., Wyatt, J. L., et al. (2009) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2009.2021401 · Cited by 156
A multiple electrode cochlear implant
Clark, G. M., Tong, Y. C., Black, R. C., Forster, I. C., Patrick, J. F., & DEWHURST, D. J. (1977) · The Journal of Laryngology & Otology · doi:10.1017/s0022215100084607 · Cited by 149
Quadrupolar stimulation for cochlear prostheses: modeling and experimental data
Jolly, C., Spelman, F. A., & Clopton, B. M. (1996) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.508549 · Cited by 141
Kanda, H., Morimoto, T., Fujikado, T., Tano, Y., Fukuda, Y., & Sawai, H. (2004) · Investigative Ophthalmology & Visual Science · doi:10.1167/iovs.02-1268 · Cited by 138 · cited 1×
“Most early suprachoroidal studies have focused primarily on monopolar stimulation, with the return electrode either in the vitreous or on the sclera.(23,25,27) With the increase in electrode numbers and density, the complex electric field interactions between stimulation electrodes will affect the ability to elicit di…”
BackgroundA novel stimulus artifact removal technique for high-rate electrical stimulation
Heffer, L. F., & Fallon, J. B. (2008) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2008.01.023 · Cited by 119
Walter, P., Szurman, P., Vobig, M. A., Berk, H., LÜDTKE-HANDJERY, H.-C., Richter, H. A., Mittermayer, C., Heimann, K., & Sellhaus, B. (1999) · Retina · doi:10.1097/00006982-199911000-00012 · Cited by 116
Electric crosstalk impairs spatial resolution of multi-electrode arrays in retinal implants
Wilke, R. G. H., Moghadam, G. K., Lovell, N. H., Suaning, G. J., & Dokos, S. (2011) · Journal of Neural Engineering · doi:10.1088/1741-2560/8/4/046016 · Cited by 110
Self-citationFocal activation of the feline retina via a suprachoroidal electrode array
Wong, Y. T., Chen, S. C., Seo, J. M., Morley, J. W., Lovell, N. H., & Suaning, G. J. (2009) · Vision Research · doi:10.1016/j.visres.2009.02.018 · Cited by 109
Self-citationSpatiotemporal Interactions in Retinal Prosthesis Subjects
Horsager, A., Greenberg, R. J., & Fine, I. (2010) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.09-3746 · Cited by 95
Transretinal electrical stimulation by an intrascleral multichannel electrode array in rabbit eyes
Nakauchi, K., Fujikado, T., Kanda, H., Morimoto, T., Choi, J., Ikuno, Y., Sakaguchi, H., Kamei, M., Ohji, M., Yagi, T., et al. (2004) · Graefe s Archive for Clinical and Experimental Ophthalmology · doi:10.1007/s00417-004-1060-2 · Cited by 92 · cited 2×
“This value is comparable to the findings of Sakaguchi et al. (42 lC cm 2) using a 500 ls phase and a 100 lm electrode45; Nakauchi et al.46 (56 lC cm 2), with a 180 lm electrode and 500 ls phase time; and Zhou et al. (48.64 lC cm 2) using a 1 ms phase time and a 300 lm electrode.23 Monopolar and hexapolar (128.5 6 11.4…”
MethodInfluentialBrindley, G. S. (1956) · The Journal of Physiology · doi:10.1113/jphysiol.1956.sp005647 · Cited by 92
Multiple components of ganglion cell desensitization in response to prosthetic stimulation
Freeman, D. K., & Fried, S. I. (2011) · Journal of Neural Engineering · doi:10.1088/1741-2560/8/1/016008 · Cited by 90 · cited 1×
“As a consequence, only the 5 ms window from 2 ms poststimulus onset to 7 ms poststimulus onset was analyzed, as spikes detected within this phase are attributed to direct retinal ganglion cell activation.(44) This allowed us to focus the analysis on the shape of the stimulating field.”
MethodThe visual sensations produced by electrical stimulation of the medial occipital cortex.
Brindley, G. S., & Lewin, W. S. (1968) · PubMed · Cited by 89
Cochlear implant electrode configuration effects on activation threshold and tonotopic selectivity
Snyder, R. L., Middlebrooks, J. C., & Bonham, B. H. (2007) · Hearing Research · doi:10.1016/j.heares.2007.09.013 · Cited by 85 · cited 1×
“tion in the auditory cortex is affected by return configurations of the stimulating device.(49,50)”
BackgroundTransretinal Electrical Stimulation with a Suprachoroidal Multichannel Electrode in Rabbit Eyes
Sakaguchi, H., Fujikado, T., Fang, X., Kanda, H., Osanai, M., Nakauchi, K., Ikuno, Y., Kamei, M., Yagi, T., Nishimura, S., et al. (2004) · Japanese Journal of Ophthalmology · doi:10.1007/s10384-004-0055-1 · Cited by 84
Cicione, R., Shivdasani, M. N., Fallon, J. B., Luu, C. D., Allen, P. J., Rathbone, G. D., Shepherd, R. K., & Williams, C. E. (2012) · Journal of Neural Engineering · doi:10.1088/1741-2560/9/3/036009 · Cited by 79 · cited 4×
“The sigmoid was used to interpolate a current value at which the spike rate reaches that of half of maximum (P50), and this was used as an indication of variation in perceptual threshold.(36) Threshold values of P50 were calculated for hexapolar, monopolar, and quasimonopolar, and the results compared to determine the…”
BackgroundMethodInfluentialRetinal Neurostimulator for a Multifocal Vision Prosthesis
Wong, Y. T., Dommel, N., Preston, P., Hallum, L. E., Lehmann, T., Lovell, N. H., & Suaning, G. J. (2007) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2007.903958 · Cited by 79 · cited 4×
“This value is comparable to the findings of Sakaguchi et al. (42 lC cm 2) using a 500 ls phase and a 100 lm electrode45; Nakauchi et al.46 (56 lC cm 2), with a 180 lm electrode and 500 ls phase time; and Zhou et al. (48.64 lC cm 2) using a 1 ms phase time and a 300 lm electrode.23 Monopolar and hexapolar (128.5 6 11.4…”
MethodInfluentialSelf-citationZhou, J., Woo, S. J., Park, S. I., Kim, E., Seo, J.-M., Chung, H., & Kim, S. J. (2008) · BioMed Research International · doi:10.1155/2008/547428 · Cited by 75 · cited 2×
“64 lC cm (2)) using a 1 ms phase time and a 300 lm electrode.(23) Monopolar and hexapolar (128.”
BackgroundMethodYamauchi, Y., Franco, L. M., Jackson, D., Naber, J. F., Ziv, R. O., Rizzo, J. F., Kaplan, H. J., & Enzmann, V. (2005) · Journal of Neural Engineering · doi:10.1088/1741-2560/2/1/007 · Cited by 71 · cited 1×
“Most early suprachoroidal studies have focused primarily on monopolar stimulation, with the return electrode either in the vitreous or on the sclera.(23,25,27) With the increase in electrode numbers and density, the complex electric field interactions between stimulation electrodes will affect the ability to elicit di…”
BackgroundZrenner, E. (2002) · Ophthalmologica · doi:10.1159/000064650 · Cited by 60
Object localization, discrimination, and grasping with the optic nerve visual prosthesis
Duret, F., Brelén, M. E., Lambert, V., Gérard, B., Delbeke, J., & Veraart, C. (2006) · Restorative Neurology and Neuroscience · doi:10.3233/rnn-2006-00328 · Cited by 59 · cited 1×
“As with most systems, the perfect device remains elusive, and various solutions have been proposed targeting the visual cortex, lateral geniculate nucleus, and optic nerve.(10,11) In recent years, approaches at the center of intense research have focused on electrical stimulation of retinal neurons that survive neural…”
BackgroundIntraocular epiretinal prosthesis to restore vision in blind humans
Mokwa, W., Goertz, M., Koch, C., Krisch, I., Trieu, H. K., & Walter, P. (2008) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2008.4650530 · Cited by 56
Electrical treatment of cardiac arrest: a cardiac stimulator-defibrillator.
Hopps, J. A., & Bigelow, W. G. (1954) · PubMed · Cited by 55
Visual Prosthetics: Physiology, Bioengineering, Rehabilitation
Dagnelie, G. (2011) · Springer eBooks · doi:10.1007/978-1-4419-0754-7 · Cited by 50
Villalobos, J., Allen, P. J., McCombe, M. F., Ulaganathan, M., Zamir, E., Ng, D. C., Shepherd, R. K., & Williams, C. E. (2011) · Graefe s Archive for Clinical and Experimental Ophthalmology · doi:10.1007/s00417-011-1794-6 · Cited by 46 · cited 2×
“Positioning the electrode in the suprachoroidal space requires a simple surgical procedure that does not require a vitrectomy.(26) To facilitate insertion of the stimulating electrode array (Fig.”
BackgroundExperimental implantation of epiretinal retina implants (EPI-RET) with an IOL-type receiver unit
Gerding, H., Benner, F. P., & Taneri, S. (2007) · Journal of Neural Engineering · doi:10.1088/1741-2560/4/1/s06 · Cited by 44 · cited 1×
“However, mechanical stability and fixation of the electrode can prove difficult.(20,21) The subretinal approach improves the mechanical stability; however, it involves complex surgery to detach the retina partially from the pigment epithelium at the implantation site.”
BackgroundHandbook of Neural Engineering
(2006) · Wiley eBooks · doi:10.1002/0470068299 · Cited by 36
Advances in Retinal Neuroprosthetics
Lovell, N. H., Hallum, L. E., Chen, S. C., Dokos, S., Byrnes‐Preston, P., Green, R. A., Poole-Warren, L. A., Lehmann, T., & Suaning, G. J. (2006) · Wiley eBooks · doi:10.1002/9780470068298.ch20 · Cited by 34
Self-citationA continuum model of retinal electrical stimulation
Joarder, S. A., Abramian, M., Suaning, G. J., Lovell, N. H., & Dokos, S. (2011) · Journal of Neural Engineering · doi:10.1088/1741-2560/8/6/066006 · Cited by 32 · cited 3×
“7) and studies by Joarder et al.35 Threshold difference likely arises from the high impedance nature of the choroid and retinal pigment epithelium47,48: monopolar stimulation, with a remote return electrode, is more likely to produce transretinal currents that stimulate the remaining retinal cells, unlike hexapolar st…”
BackgroundInfluentialSelf-citationAn automated system for rapid evaluation of high-density electrode arrays in neural prostheses
John, S. E., Shivdasani, M. N., Leuenberger, J., Fallon, J. B., Shepherd, R. K., Millard, R. E., Rathbone, G. D., & Williams, C. E. (2011) · Journal of Neural Engineering · doi:10.1088/1741-2560/8/3/036011 · Cited by 21 · cited 2×
“The isolated PXI chassis (PXI-1000B) system included a switch matrix (PXI2532) to redirect the charge-balanced, constant current biphasic pulse,(41) generated by the stimulator, and a digital multimeter (DMM; PXI-4072) to acquire the resulting voltage waveform and determine values for electrode impedance as described…”
MethodEfficacy of supra-choroidal, bipolar, electrical stimulation in a vision prosthesis
Wong, Y. T., Chen, S. C., Kerdraon, Y., Allen, P. J., McCombe, M. F., Morley, J. W., Lovell, N. H., & Suaning, G. J. (2008) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2008.4649525 · Cited by 14
Self-citationDodds, C. W. D., Schüettler, M., Guenther, T., Lovell, N. H., & Suaning, G. J. (2011) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2011.6090141 · Cited by 12
Self-citationSiu, T. L. T., & Morley, J. W. (2008) · Journal of Clinical Neuroscience · doi:10.1016/j.jocn.2007.06.012 · Cited by 10 · cited 1×
“Stimulating electrodes have been positioned on the retina (epiretinal), below the retina (subretinal), between the choroid and sclera (suprachoroidal), and outside the sclera (episcleral).(15) The epiretinal approach involves positioning the stimulating electrodes directly adjacent to the retinal ganglion cells and ne…”
BackgroundSelf-citationFried, S. I., & Jensen, R. J. (2011) · Springer eBooks · doi:10.1007/978-1-4419-0754-7_12 · Cited by 2 · cited 1×
“This allows the electrodes to be in close proximity to the ganglion cells, with results showing that this position yields the lowest activation threshold of all the approaches.(19) However, mechanical stability and fixation of the electrode can prove difficult.”
Background
Cited by
Dynamic Stimulation of Visual Cortex Produces Form Vision in Sighted and Blind Humans
Beauchamp, M. S., Oswalt, D., Sun, P., Foster, B. L., Magnotti, J. F., Niketeghad, S., Pouratian, N., Bosking, W. H., & Yoshor, D. (2020) · Cell · doi:10.1016/j.cell.2020.04.033 · Cited by 257
“For instance, current steering has been applied both in retinal implants (Dumm et al., 2014; Matteucci et al., 2013), cochlear implants (Firszt et al.”
BackgroundEmerging therapies for inherited retinal degeneration
Scholl, H. P. N., Strauss, R. W., Singh, M. S., Dalkara, D., Roska, B., Picaud, S., & Sahel, J.-A. (2016) · Science Translational Medicine · doi:10.1126/scitranslmed.aaf2838 · Cited by 219
Spatially patterned electrical stimulation to enhance resolution of retinal prostheses
Jepson, L. H., Hottowy, P., Mathieson, K., Gunning, D. E., Dąbrowski, W., Litke, A. M., & Chichilnisky, E. J. (2014) · The Journal of Neuroscience · doi:10.1523/jneurosci.2882-13.2014 · Cited by 103
Goding, J. A., Gilmour, A. D., Robles, U. A. A., Hasan, E. A., & Green, R. A. (2017) · Advanced Functional Materials · doi:10.1002/adfm.201702969 · Cited by 95
Electrical Stimulation of the Retina to Produce Artificial Vision
Weiland, J. D., Walston, S. T., & Humayun, M. S. (2016) · Annual Review of Vision Science · doi:10.1146/annurev-vision-111815-114425 · Cited by 97
Metadata
- Authors
- Matteucci, P. B., Chen, S. C., Tsai, D., Dodds, C. W. D., Dokos, S., Morley, J. W., Lovell, N. H., & Suaning, G. J.
- Affiliations
- UNSW Sydney (AU)
- The University of Sydney (AU)
- Howard Hughes Medical Institute (US)
- Corresponding author
- Matteucci, Paul B.
- Venue
- Investigative Opthalmology & Visual Science
- Published
- 2013-06-21
- Volume
- 54
- Issue
- 6
- Pages
- 4307
- ISSN
- 0146-0404 (ISSN-L)
- 1552-5783
- OpenAlex
- W1990485400
- Cited by
- 79
- References
- 55
- Citations by year
- 2026: 4 · 2024: 2 · 2023: 3 · 2022: 7 · 2021: 5 · 2020: 6 · 2019: 5 · 2018: 10 · 2017: 7 · 2016: 16 · 2015: 6 · 2014: 8
- FWCI
- 4.91
- Type
- journal article
- Language
- en
- Open access
- hybrid
- doi.org
- Licence
- cc-by
- Locations
- Investigative Ophthalmology & Visual Science (publishedVersion, cc-by)
- PubMed (publishedVersion)
- Funders
- University of New South Wales
- Topics
- Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
- Health Sciences › Medicine › Ophthalmology › Retinal Development and Disorders
- Health Sciences › Medicine › Anesthesiology and Pain Medicine › Pain Management and Treatment
- Keywords
- retinal prosthesis, current shunting, activation threshold, phosphenes, retinal degeneration
- MeSH terms
- Animals, Cats, Choroid, Electric Stimulation, Electrodes, Implanted, Evoked Potentials, Visual, Phosphenes, Retinal Ganglion Cells, Visual Perception, Prostheses and Implants, Visual Prosthesis
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.