The DOI matches its Crossref record; 54 of the 55 references it cites were found in a registry or an index.
Current Steering in Retinal Stimulation via a Quasimonopolar Stimulation Paradigm
Open accessAbstract
PURPOSE: Research to restore some degree of vision to patients suffering from retinal degeneration is becoming increasingly more promising. Several groups have chosen electrical stimulation of the remaining network of a degenerate retina as a means to generate discrete light percepts (phosphenes). Approaches vary significantly, with the greatest difference being the location of the stimulating electrode itself. METHODS: Suprachoroidal positioning offers excellent mechanical stability and surgical simplicity; however, at the cost of activation thresholds and focused stimulation due to the distance from the electrodes to the target neurons. Past studies proposed a hexapolar electrode configuration to focus the cortical activation and minimize cross-talk between electrodes during concurrent stimulation. The high impedance nature of the choroid and pigment epithelium, however, cause current to shunt between the stimulating and return electrodes, resulting in even higher activation thresholds. In our study, we analyzed the effect of stimulating the feline retina using a quasimonopolar stimulation by simultaneously stimulating a hexapolar and distant monopolar return configurations. RESULTS: Results of in vivo studies showed that quasimonopolar stimulation can be used to maintain the activation containment properties of hexapolar stimulation, while lowering the activation threshold to values almost equivalent to those of monopolar stimulation. CONCLUSIONS: The optimal stimulus was found to be composed of a subthreshold monopolar stimulus combined with a suprathreshold hexapolar stimulation. This resulted in a decrease of activation threshold of 60% with respect to hexapolar alone, but with no discernible deleterious effect on the charge containment of a pure hexapolar stimulation.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“For instance, current steering has been applied both in retinal implants (Dumm et al., 2014; Matteucci et al., 2013), cochlear implants (Firszt et al., 2007; Kalkman et al., 2016) and deep brain stimulators (Gross and McDougal, 2013) although it has not yet found clinical applications in the cerebral cortex.”
From Dynamic Stimulation of Visual Cortex Produces Form Vision in Sighted and Blind Humans (2020) · cites this paper as Matteucci et al., 2013
Citations
Cites
The sensations produced by electrical stimulation of the visual cortex
Brindley, G. S., & Lewin, W. S. (1968) · The Journal of Physiology · doi:10.1113/jphysiol.1968.sp008519 · Cited by 1,170
Rf, G. (1985) · Cited by 949
Wt, L., Holmquest, H. J., Scot, D., & Dow, M. (1961) · PubMed · Cited by 898
The retinotopic organization of area 17 (striate cortex) in the cat
Tusa, R. J., Palmer, L. A., & Rosenquist, A. C. (1978) · Journal of Comparative Neurology · doi:10.1002/cne.901770204 · Cited by 737 · cited 1×
“Previous studies also have indicated a correlation between retinal recruitment and cortical activation localization.(40) Recently, however, there has been evidence that the correlation does not always correspond to an equivalent increase in cortical localization.”
Rizzo, J. F., Wyatt, J., Loewenstein, J., Kelly, S., & Shire, D. (2003) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.02-0817 · Cited by 478
Dobelle, W. H., & Mladejovsky, M. G. (1974) · The Journal of Physiology · doi:10.1113/jphysiol.1974.sp010766 · Cited by 468
A neural interface for a cortical vision prosthesis
Normann, R. A., Maynard, E. M., Rousche, P. J., & Warren, D. J. (1999) · Vision Research · doi:10.1016/s0042-6989(99)00040-1 · Cited by 409
Veraart, C., Raftopoulos, C., Mortimer, J. T., Delbeke, J., Pins, D., Michaux, G., Vanlierde, A., Parrini, S., & Wanet-Defalque, M.-C. (1998) · Brain Research · doi:10.1016/s0006-8993(98)00977-9 · Cited by 405
Morphometric analysis of the extramacular retina from postmortem eyes with retinitis pigmentosa.
Humayun, M. S., Prince, M. R., de Juan, E., Barrón, Y., Moskowitz, M., Klock, I. B., & Milam, A. H. (1999) · PubMed · Cited by 366
Rose, T. L., & Robblee, L. S. (1990) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.61038 · Cited by 358
Cited by
Dynamic Stimulation of Visual Cortex Produces Form Vision in Sighted and Blind Humans
Beauchamp, M. S., Oswalt, D., Sun, P., Foster, B. L., Magnotti, J. F., Niketeghad, S., Pouratian, N., Bosking, W. H., & Yoshor, D. (2020) · Cell · doi:10.1016/j.cell.2020.04.033 · Cited by 257
“For instance, current steering has been applied both in retinal implants (Dumm et al., 2014; Matteucci et al., 2013), cochlear implants (Firszt et al.”
BackgroundEmerging therapies for inherited retinal degeneration
Scholl, H. P. N., Strauss, R. W., Singh, M. S., Dalkara, D., Roska, B., Picaud, S., & Sahel, J.-A. (2016) · Science Translational Medicine · doi:10.1126/scitranslmed.aaf2838 · Cited by 219
Spatially patterned electrical stimulation to enhance resolution of retinal prostheses
Jepson, L. H., Hottowy, P., Mathieson, K., Gunning, D. E., Dąbrowski, W., Litke, A. M., & Chichilnisky, E. J. (2014) · The Journal of Neuroscience · doi:10.1523/jneurosci.2882-13.2014 · Cited by 103
Goding, J. A., Gilmour, A. D., Robles, U. A. A., Hasan, E. A., & Green, R. A. (2017) · Advanced Functional Materials · doi:10.1002/adfm.201702969 · Cited by 95
Electrical Stimulation of the Retina to Produce Artificial Vision
Weiland, J. D., Walston, S. T., & Humayun, M. S. (2016) · Annual Review of Vision Science · doi:10.1146/annurev-vision-111815-114425 · Cited by 97
Laser patterning of platinum electrodes for safe neurostimulation
Green, R. A., Matteucci, P. B., Dodds, C. W. D., Palmer, J., Dueck, W. F., Hassarati, R. T., Byrnes-Preston, P., Lovell, N. H., & Suaning, G. J. (2014) · Journal of Neural Engineering · doi:10.1088/1741-2560/11/5/056017 · Cited by 86
“Measurements were made in conjunction with other visual percept investigations, presented elsewhere [34, 35], and hence these studies were performed at 36 h post implantation.”
ResultSelf-citationVisual prosthesis: interfacing stimulating electrodes with retinal neurons to restore vision.
Barriga-Rivera, A., Bareket, L., Goding, J., Aregueta-Robles, U. A., & Suaning, G. J. (2017) · Frontiers in Neuroscience · doi:10.3389/fnins.2017.00620 · Cited by 73
“While electrical return path configurations such as hexapolar or the quasi-monopolar stimulation paradigms provide more contained spread of the electric field using hexagonal guards to recover electric current (Matteucci et al., 2013), the combined effect of cross-talk and axonal stimulation has led to the reporting o…”
BackgroundSelf-citationPixium Vision: First Clinical Results and Innovative Developments
Hornig, R., Dapper, M., Joliff, E. L., Hill, R. G., Ishaque, K., Posch, C., Benosman, R. B., Mer, Y. L., Sahel, J., & Picaud, S. A. (2016) · Springer eBooks · doi:10.1007/978-3-319-41876-6_8 · Cited by 73
Cortical visual prostheses: From microstimulation to functional percept
Najarpour Foroushani, A., Pack, C. C., & Sawan, M. (2018) · Journal of Neural Engineering · doi:10.1088/1741-2552/aaa904 · Cited by 62
“This issue could be overcome with a quasi-monopolar strategy [120, 122].”
BackgroundBendali, A., Rousseau, L., Lissorgues, G., Scorsone, E., Djilas, M., Dégardin, J., Dubus, E., Fouquet, S., Benosman, R., Bergonzo, P., et al. (2015) · Biomaterials · doi:10.1016/j.biomaterials.2015.07.018 · Cited by 66
Honeycomb-shaped electro-neural interface enables cellular-scale pixels in subretinal prosthesis
Flores, T. A., Huang, T., Bhuckory, M. B., Ho, E., Chen, Z., Dalal, R., Galambos, L., Kamins, T. I., Mathieson, K., & Palanker, D. (2019) · Scientific Reports · doi:10.1038/s41598-019-47082-y · Cited by 66
The appearance of phosphenes elicited using a suprachoroidal retinal prosthesis
Sinclair, N. C., Shivdasani, M. N., Perera, T., Gillespie, L. N., McDermott, H. J., Ayton, L. N., Blamey, P. J., & for the Bionic Vision Australia Consortium (2016) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.15-18991 · Cited by 60
“, common ground, hexagonal, pseudo-hexagonal) were able to limit the spread of retinal and cortical activation when compared to monopolar stimulation.(36,51) A caveat to be noted is that in this study and all reported preclinical studies, only single-electrode stimulation was used.”
ResultTowards high-resolution retinal prostheses with direct optical addressing and inductive telemetry
Ha, S., Khraiche, M. L., Akinin, A., Jing, Y., Damle, S., Kuang, Y. J., Bauchner, S., Lo, Y., Freeman, W. R., Silva, G. A., et al. (2016) · Journal of Neural Engineering · doi:10.1088/1741-2560/13/5/056008 · Cited by 56
Teplitzky, B. A., Verbick, L. Z., Xiao, Y., & Johnson, M. D. (2016) · Frontiers in Computational Neuroscience · doi:10.3389/fncom.2016.00058 · Cited by 50
“…steering with implantable electrode arrays has existed in the fields of spinal cord stimulation (Holsheimer et al., 1998; Manola et al., 2007), intracochlear stimulation (Firszt et al., 2007; Berenstein et al., 2008), and retinal stimulation (Matteucci et al., 2013; Dumm et al., 2014) for some time.”
BackgroundEpiretinal stimulation with local returns enhances selectivity at cellular resolution
Fan, V. H., Grosberg, L. E., Madugula, S. S., Hottowy, P., Dąbrowski, W., Sher, A., Litke, A. M., & Chichilnisky, E. J. (2018) · Journal of Neural Engineering · doi:10.1088/1741-2552/aaeef1 · Cited by 45
High-amplitude electrical stimulation can reduce elicited neuronal activity in visual prosthesis
Barriga‐Rivera, A., Guo, T., Yang, C.-Y., Abed, A. A., Dokos, S., Lovell, N. H., Morley, J. W., & Suaning, G. J. (2017) · Scientific Reports · doi:10.1038/srep42682 · Cited by 40
Self-citationThe Effect of Electric Cross-Talk in Retinal Neurostimulation
Matteucci, P. B., Barriga‐Rivera, A., Eiber, C. D., Lovell, N. H., Morley, J. W., & Suaning, G. J. (2016) · Investigative Ophthalmology & Visual Science · doi:10.1167/iovs.15-18400 · Cited by 42
“In a previous study, the QMP stimulation paradigm was presented whereby return current was shared between a distant monopolar electrode and a surrounding hexapolar guard.(9) The QMP approach possessed the low-threshold characteristics of monopolar stimulation and the contained and focused retinal activation of hexapol…”
MethodInfluentialSelf-citationComputational challenges and opportunities for a bi-directional artificial retina
Shah, N. P., & Chichilnisky, E. J. (2020) · Journal of Neural Engineering · doi:10.1088/1741-2552/aba8b1 · Cited by 39
Improved visual acuity using a retinal implant and an optimized stimulation strategy
Tong, W., Stamp, M. E. M., Apollo, N. V., Ganesan, K., Hamish Meffin, A., Prawer, S., Garrett, D. J., & Ibbotson, M. R. (2019) · Journal of Neural Engineering · doi:10.1088/1741-2552/ab5299 · Cited by 45
Biocompatibility and functionalization of diamond for neural applications
Yang, K., & Narayan, R. J. (2019) · Current Opinion in Biomedical Engineering · doi:10.1016/j.cobme.2019.03.002 · Cited by 36
Quasi-monopolar electrical stimulation of the retina: a computational modelling study
Abramian, M., Lovell, N. H., Habib, A., Morley, J. W., Suaning, G. J., & Dokos, S. (2014) · Journal of Neural Engineering · doi:10.1088/1741-2560/11/2/025002 · Cited by 36
Self-citationProgress in artificial vision through suprachoroidal retinal implants
Bareket, L., Barriga‐Rivera, A., Zapf, M. P., Lovell, N. H., & Suaning, G. J. (2017) · Journal of Neural Engineering · doi:10.1088/1741-2552/aa6cbb · Cited by 45
Self-citationOptimization of Electrical Stimulation for a High-Fidelity Artificial Retina
Shah, N. P., Madugula, S., Grosberg, L., Mena, G., Tandon, P., Hottowy, P., Sher, A., Litke, A., Mitra, S., & Chichilnisky, E. J. (2019) · 2019 9th International IEEE/EMBS Conference on Neural Engineering (NER) · doi:10.1109/ner.2019.8716987 · Cited by 32
“For example, the impact of different electrical stimulation patterns such as current steering [17], [19], [20] and local return [21], [22] can be directly compared by evaluating the quality of the final inferred visual image.”
BackgroundSpencer, T. C., Fallon, J. B., Thien, P. C., & Shivdasani, M. N. (2016) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.16-19325 · Cited by 31
Creating virtual electrodes with 2D current steering
Spencer, T. C., Fallon, J. B., & Shivdasani, M. N. (2018) · Journal of Neural Engineering · doi:10.1088/1741-2552/aab1b8 · Cited by 33
3D Diamond Electrode Array for High-Acuity Stimulation in Neural Tissue
Stamp, M. E. M., Tong, W., Ganesan, K., Prawer, S., Ibbotson, M. R., & Garrett, D. J. (2020) · ACS Applied Bio Materials · doi:10.1021/acsabm.9b01165 · Cited by 29
Implications of Neural Plasticity in Retinal Prosthesis
Caravaca-Rodriguez, D., Gaytan, S. P., Suaning, G. J., & Barriga‐Rivera, A. (2022) · Investigative Ophthalmology & Visual Science · doi:10.1167/iovs.63.11.11 · Cited by 42
Self-citationApproaches to a cortical vision prosthesis: implications of electrode size and placement
Christie, B. P., Ashmont, K. R., House, P. A., & Greger, B. (2016) · Journal of Neural Engineering · doi:10.1088/1741-2560/13/2/025003 · Cited by 26
Yang, C. Y., Tsai, D., Guo, T., Dokos, S., Suaning, G. J., Morley, J. W., & Lovell, N. H. (2018) · Journal of Neural Engineering · doi:10.1088/1741-2552/aac315 · Cited by 27
Self-citationNeural Responses to Multielectrode Stimulation of Healthy and Degenerate Retina
Halupka, K. J., Abbott, C. J., Wong, Y. T., Cloherty, S. L., Grayden, D. B., Burkitt, A. N., Sergeev, E. N., Luu, C. D., Brandli, A. A., Allen, P. J., et al. (2017) · Investigative Ophthalmology & Visual Science · doi:10.1167/iovs.16-21290 · Cited by 25
Performance optimization of current focusing and virtual electrode strategies in retinal implants
Moghaddam, G. K., Lovell, N. H., Wilke, R. G. H., Suaning, G. J., & Dokos, S. (2014) · Computer Methods and Programs in Biomedicine · doi:10.1016/j.cmpb.2014.06.012 · Cited by 24
Self-citationEggenberger, S. C., James, N. L., Ho, C., Eamegdool, S. S., Tatarinoff, V., Craig, N. A., Gow, B. S., Wan, S., Dodds, C. W. D., La Hood, D., et al. (2021) · Biomaterials · doi:10.1016/j.biomaterials.2021.121191 · Cited by 21
Self-citationModelling of magnetoelectric nanoparticles for non-invasive brain stimulation: a computational study
Fiocchi, S., Chiaramello, E., Marrella, A., Bonato, M., Parazzini, M., & Ravazzani, P. (2022) · Journal of Neural Engineering · doi:10.1088/1741-2552/ac9085 · Cited by 27
“Micro-stimulation and retina stimulation studies (Matteucci et al 2013, Urdaneta et al 2021) have shown that an effective spread of neural activation can be expressed as the square root of the current injected in the electrode divided by the square root of the excitability constant, i.e. r =…”
BackgroundLyu, Q., Lu, Z., Li, H., Qiu, S., Guo, J., Sui, X., Sun, P., Li, L., Chai, X., & Lovell, N. H. (2019) · International Journal of Neural Systems · doi:10.1142/s0129065720500069 · Cited by 24
Self-citationPrediction of cortical responses to simultaneous electrical stimulation of the retina
Halupka, K. J., Shivdasani, M. N., Cloherty, S. L., Grayden, D. B., Wong, Y. T., Burkitt, A. N., & Hamish Meffin, A. (2016) · Journal of Neural Engineering · doi:10.1088/1741-2560/14/1/016006 · Cited by 23
Spike-triggered average electrical stimuli as input filters for bionic vision—a perspective
Rathbun, D. L., Ghorbani, N., Shabani, H., Zrenner, E., & Hosseinzadeh, Z. (2018) · Journal of Neural Engineering · doi:10.1088/1741-2552/aae493 · Cited by 22
Neuromodulation of the retina from the suprachoroidal space: The Phoenix 99 implant
Suaning, G. J., Lovell, N. H., & Lehmann, T. (2014) · IEEE Biomedical Circuits and Systems Conference (BioCAS) · doi:10.1109/biocas.2014.6981711 · Cited by 20
“To address that issue, we introduced a quasimonopolar (QMP) stimulation approach wherein a combination of mono- and hexapolar stimulation served to reduce the stimulation threshold while at the same time containing the extent of retinal activation to an area limited by the hexagon guard ring [16].”
MethodSelf-citationProbing the functional impact of sub-retinal prosthesis
Roux, S., Matonti, F., Dupont, F., Hoffart, L., Takerkart, S., Picaud, S., Pham, P., & Chavane, F. (2016) · eLife · doi:10.7554/elife.12687 · Cited by 18
“, 2008), including current steering methods (Jepson et al., 2014a; Matteucci et al., 2013) or the effect of the return electrode configuration (Cicione et al.”
BackgroundMethodInfluentialCorna, A., Ramesh, P., Jetter, F., Lee, M.-J., Macke, J. H., & Zeck, G. (2021) · Journal of Neural Engineering · doi:10.1088/1741-2552/ac0679 · Cited by 18
“The confinement or steering of the stimulating electrical field [11, 71] is part of ongoing research and may be combined in future with sinusoidal or smooth-wave stimuli.”
BackgroundSpatially patterned bi-electrode epiretinal stimulation for axon avoidance at cellular resolution
Vilkhu, R. S., Madugula, S. S., Grosberg, L. E., Gogliettino, A. R., Hottowy, P., Dąbrowski, W., Sher, A., Litke, A. M., Mitra, S., & Chichilnisky, E. J. (2021) · Journal of Neural Engineering · doi:10.1088/1741-2552/ac3450 · Cited by 21
Zapf, M. P., Boon, M. Y., Matteucci, P. B., Lovell, N. H., & Suaning, G. J. (2015) · Journal of Neural Engineering · doi:10.1088/1741-2560/12/3/036001 · Cited by 26
Self-citationCicione, R., Fallon, J. B., Rathbone, G. D., Williams, C. E., & Shivdasani, M. N. (2014) · Investigative Ophthalmology & Visual Science · doi:10.1167/iovs.14-14754 · Cited by 17
Long‐term anesthetic protocol in rats: feasibility in electrophysiology studies in visual prosthesis
Barriga‐Rivera, A., Tatarinoff, V., Lovell, N. H., Morley, J. W., & Suaning, G. J. (2017) · Veterinary Ophthalmology · doi:10.1111/vop.12507 · Cited by 17
“In similar experiments, Matteucci et al.10,24 used a combination of intravenous infusion of alphaxalone and inhaled isoflurane.”
MethodResultInfluentialSelf-citationItaliano, M. L., Guo, T., Lovell, N. H., & Tsai, D. (2022) · Journal of Neural Engineering · doi:10.1088/1741-2552/ac72c2 · Cited by 18
Self-citationBiophysical basis of the linear electrical receptive fields of retinal ganglion cells
Esler, T. B., Maturana, M. I., Kerr, R. R., Grayden, D. B., Burkitt, A. N., & Hamish Meffin, A. (2018) · Journal of Neural Engineering · doi:10.1088/1741-2552/aacbaa · Cited by 18
Borda, E., Gaillet, V., Airaghi Leccardi, M. J. I., Zollinger, E. G., Moreira, R. C., & Ghezzi, D. (2022) · Journal of Neural Engineering · doi:10.1088/1741-2552/ac6d7e · Cited by 11
Barriga‐Rivera, A., Morley, J. W., Lovell, N. H., & Suaning, G. J. (2016) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2016.7591956 · Cited by 11
“Alternatives such as the quasi-monopolar approach [6] led to reduced activation thresholds with more restricted spatial activation.”
BackgroundSelf-citationElectrical Field Shaping Techniques in a Feline Model of Retinal Degeneration
Spencer, T. C., Fallon, J. B., Abbott, C. J., Allen, P. J., Brandli, A. A., Luu, C. D., Epp, S. B., & Shivdasani, M. N. (2018) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2018.8512473 · Cited by 9
Computational Models of Neural Retina
Dokos, S., & Guo, T. (2020) · Springer eBooks · doi:10.1007/978-1-4614-7320-6_652-2 · Cited by 10
Self-citationReal-Time Optimization of the Current Steering for Visual Prosthesis
Chen, Z., Wang, B.-Y., & Palanker, D. (2021) · International IEEE/EMBS Conference on Neural Engineering · doi:10.1109/ner49283.2021.9441400 · Cited by 10
“Computation of the electric field emanating from multiple electrodes involves Poisson’s equation of volume conduction, which can be solved with the finite element method (FEM) [3][6][7][10][11][12].”
BackgroundMethodA 4+1 architecture for in vivo electrophysiology visual prosthesis
Barriga‐Rivera, A., Eiber, C. D., Matteucci, P. B., Chen, S. C., Morley, J. W., Lovell, N. H., & Suaning, G. J. (2016) · Journal of Accessibility and Design for All · doi:10.17411/jacces.v6i2.108 · Cited by 8
“…electrode arrays are fabricated at the authors’ laboratory by laser micromachining of platinum foil positioned on a polydimethylsiloxane substrate and mechanically strengthened with a layer of polyethylene terephthalate (Dodds, Schuettler, Guenther, Lovell, & Suaning, 2011; Matteucci et al., 2013).”
BackgroundMethodInfluentialSelf-citationXie, Y., Qin, P., Guo, T., Abed, A. A., Lovell, N. H., & Tsai, D. (2023) · Journal of Neural Engineering · doi:10.1088/1741-2552/aced20 · Cited by 8
Self-citationElectrically evoked potentials in an ovine model for the evaluation of visual prosthesis efficacy
Barriga‐Rivera, A., Eiber, C. D., Dodds, C. W. D., Fung, A. T.-C., Tatarinoff, V., Lovell, N. H., & Suaning, G. J. (2015) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2015.7319112 · Cited by 6
Self-citationSuprachoroidal Retinal Prostheses
Ayton, L. N., Suaning, G. J., Lovell, N. H., Petoe, M. A., Nayagam, D. A. X., Brawn, T.-L. E., & Burkitt, A. N. (2016) · Springer eBooks · doi:10.1007/978-3-319-41876-6_10 · Cited by 6
Self-citationStimulation of peripheral nerves using conductive hydrogel electrodes
Gilmour, A. D., Goding, J. A., Robles, U. A. A., Staples, N. A., Byrnes‐Preston, P., Morley, J. W., Lovell, N. H., Chew, D. J., & Green, R. A. (2018) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2018.8513628 · Cited by 4
Self-citationVirtual electrodes generated by focused penta‐polar current stimulation for neuromodulation
Shim, S., Park, J. H., & Kim, S. J. (2020) · Micro & Nano Letters · doi:10.1049/mnl.2019.0348 · Cited by 4
Neural Implants Without Electronics: A Proof-of-Concept Study on a Human Skin Model
Kiele, P., Braig, D., Weis, J., Baslan, Y., Pasluosta, C. F., & Stieglitz, T. (2020) · IEEE Open Journal of Engineering in Medicine and Biology · doi:10.1109/ojemb.2020.2981254 · Cited by 5
“Using current steering, this drawback might be overcome [28] at the cost of another”
BackgroundXiao, Y., & Johnson, M. D. (2015) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2015.08.001 · Cited by 3
Computational Models of Neural Retina
Dokos, S., & Guo, T. (2022) · Springer eBooks · doi:10.1007/978-1-0716-1006-0_652 · Cited by 3
Self-citationOptic nerve and retinal electrostimulation in rats: direct activation of the retinal ganglion cells
Barriga‐Rivera, A., Suaning, G. J., Delgado-Garcia, J. M., & Gruart, A. (2018) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2018.8512517 · Cited by 2
“es neighboring electrodes can be used to inhibit neural activation [4] or to focus the electric current towards the desired retinal area [5].”
MethodSelf-citationPartitioned Temporal Dithering for Efficient Epiretinal Electrical Stimulation
Lotlikar, A., Shah, N. P., Gogliettino, A. R., Vilkhu, R. S., Madugula, S. S., Grosberg, L. E., Hottowy, P., Sher, A., Litke, A. M., Chichilnisky, E. J., et al. (2023) · International IEEE/EMBS Conference on Neural Engineering · doi:10.1109/ner52421.2023.10123787 · Cited by 3
A method to assess the location and positional stability of supra-choroidal retinal neuroprostheses
Gow, B. S., & Suaning, G. J. (2016) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2016.7591782 · Cited by 2
Self-citationLemaire, W., Benhouria, M., Koua, K., Tong, W., Martin-Hardy, G., Stamp, M. E. M., Ganesan, K., Gauthier, L.-P., Besrour, M., Ahnood, A., et al. (2024) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2024.3516492 · Cited by 3
“It also limits the use of active charge balancing [14], [15] and the delivery of flexible multipolar stimulation patterns such as current steering [16], [17] and current focusing [18], which are demonstrated means of enhancing spatial resolution.”
BackgroundVisual Prosthesis, Suprachoroidal, and Trans-retinal Devices
Suaning, G. J. (2014) · Springer eBooks · doi:10.1007/978-1-4614-7320-6_668-1
Self-citationRetinal/Visual Interfaces (Models, Theory, Techniques): Overview
Lovell, N. H. (2015) · Springer eBooks · doi:10.1007/978-1-4614-6675-8_789
Self-citationA model of electrical stimulation of a retinal cell population using a multi-electrode array
Abed, A. A., Lovell, N. H., Suaning, G. J., & Dokos, S. (2015) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2015.7318849
“The electrical stimulation paradigms simulated in this study and multi-electrode array design were employed in an in vivo feline study of suprachoroidal stimulation [13].”
BackgroundMethodSelf-citationStrategic circuits for neuromodulation of the visual system
Suaning, G. J. (2017) · Asia and South Pacific Design Automation Conference (ASP-DAC) · doi:10.1109/aspdac.2017.7858336 · Cited by 1
Self-citationExperimental and Model-based Approaches to Directional Thalamic Deep Brain Stimulation
Xiao, J. (2016) · University of Minnesota Digital Conservancy (University of Minnesota)
Current Advances in the Design of Retinal and Cortical Visual Prostheses
Bareket, L., Barriga‐Rivera, A., Rosenfeld, J. V., Lovell, N. H., & Suaning, G. J. (2018) · Elsevier eBooks · doi:10.1016/b978-0-12-812539-7.00005-2
Self-citationSelective electrical stimulation with current-field modulation
Kárason, H., Pilkington, Ó., & Helgason, Þ. (2021) · Current Directions in Biomedical Engineering · doi:10.1515/cdbme-2021-2205
Visual Prosthesis, Suprachoroidal and Trans-retinal Devices
Suaning, G. J. (2022) · Springer eBooks · doi:10.1007/978-1-0716-1006-0_668
Self-citationRetinal/Visual Interfaces (Models, Theory, Techniques): Overview
Lovell, N. H. (2022) · Springer eBooks · doi:10.1007/978-1-0716-1006-0_789
Self-citationRetinal/Visual Interfaces (Models, Theory, Techniques): Overview
Lovell, N. H. (2014) · Springer eBooks · doi:10.1007/978-1-4614-7320-6_789-1
Self-citationFactors Affecting the Efficacy of Retinal Implants
Alqahtani, A. (2023) · International Conference on Bio Signals, Images, and Instrumentation (ICBSII) · doi:10.1109/icbsii58188.2023.10181078
An arbitrary waveform neurostimulator for preclinical studies: design and verification
Guzmán-Miranda, H., & Barriga‐Rivera, A. (2024) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-024-03241-6 · Cited by 2
“This device allows for investigating the benefits of a number of stimulation strategies that include current steering [31, 32], temporal interference [18], and stochastic facilitation [33] among others.”
Bilateral retinal implants for improving visual restoration: a simulated bionic vision study
Rodriguez-Miguez, P., Soria, P. R., & Barriga‐Rivera, A. (2026) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-026-03513-3
A Dynamic Virtual Channel Approach to Enhance Retinal Prosthetic Precision
Liu, Z., Guo, T., He, Y., Zheng, S., Song, X., Dai, C., Li, J., Chai, X., Chen, Y., & Li, L. (2026) · Biomimetics · doi:10.3390/biomimetics11050307
“Building on this concept, Matteucci et al. developed a quasi-monopolar stimulation paradigm that maintains comparable stimulus focality and overcomes the high activation threshold limitations inherent to the local current recycling strategy [36].”
Stimulus Optimization Using the Artificial Bee Colony Algorithm for Visual Neuroprostheses
Pratiwi, A. M., Jara-Balsera, J., Guzmán-Miranda, H., Suaning, G. J., & Barriga‐Rivera, A. (2026) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2026.3706302
Self-citationToward Electrical Impedance Tomography of Functional Activity in the RetinaPreprint
Ravagli, E., McEwan, A., Protti, D., & Aristovich, K. Y. (2026) · bioRxiv (Cold Spring Harbor Laboratory) · doi:10.64898/2026.10.23.761326
“One critical aspect that remains a strong focus of current research is the identification of optimal spatial and temporal patterns of electrical stimulation needed to elicit retinal activity that will lead to visual perception [17].”
Metadata
- Authors
- Matteucci, P. B., Chen, S. C., Tsai, D., Dodds, C. W. D., Dokos, S., Morley, J. W., Lovell, N. H., & Suaning, G. J.
- Affiliations
- UNSW Sydney (AU)
- The University of Sydney (AU)
- Howard Hughes Medical Institute (US)
- Corresponding author
- Matteucci, Paul B.
- Venue
- Investigative Opthalmology & Visual Science
- Published
- 2013-06-21
- Volume
- 54
- Issue
- 6
- Pages
- 4307
- ISSN
- 0146-0404 (ISSN-L)
- 1552-5783
- OpenAlex
- W1990485400
- Cited by
- 79
- References
- 55
- Citations by year
- 2026: 4 · 2024: 2 · 2023: 3 · 2022: 7 · 2021: 5 · 2020: 6 · 2019: 5 · 2018: 10 · 2017: 7 · 2016: 16 · 2015: 6 · 2014: 8
- FWCI
- 4.91
- Type
- journal article
- Language
- en
- Open access
- hybrid
- doi.org
- Licence
- cc-by
- Locations
- Investigative Ophthalmology & Visual Science (publishedVersion, cc-by)
- PubMed (publishedVersion)
- Funders
- University of New South Wales
- Topics
- Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
- Health Sciences › Medicine › Ophthalmology › Retinal Development and Disorders
- Health Sciences › Medicine › Anesthesiology and Pain Medicine › Pain Management and Treatment
- Keywords
- retinal prosthesis, current shunting, activation threshold, phosphenes, retinal degeneration
- MeSH terms
- Animals, Cats, Choroid, Electric Stimulation, Electrodes, Implanted, Evoked Potentials, Visual, Phosphenes, Retinal Ganglion Cells, Visual Perception, Prostheses and Implants, Visual Prosthesis
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.