The Effect of Electric Cross-Talk in Retinal Neurostimulation
Open accessThe DOI matches its Crossref record; 12 of the 12 references it cites were found in a registry or an index.
Abstract
PURPOSE: To investigate the efficacy of electric field shaping in modulating the extent and activation threshold in retinal neurostimulation. This study aims to quantify the interference of neighboring stimulation sites by assessing the shift in the activation threshold produced by a concomitant interfering stimulus. METHODS: Electrical stimuli were applied to healthy retinae in a feline model (n = 4) using a 24-channel electrode array surgically implanted in the suprachoroidal space. A 96-channel penetrating electrode array was used for recording cortical responses to a number of stimulation paradigms. Data were analyzed offline. Concurrent monopolar and hexapolar stimuli were delivered at primary and interfering sites separated by up to 2.19 mm to evaluate electric cross-talk. The spike rate was fit to a sigmoidal curve to estimate the P50 threshold. The slope of the linear regression of the P50 value versus interfering current level was considered as a measure of cross-talk. RESULTS: Concurrent monopolar stimulation produced a proportional drop in the P50 of approximately 20% of the interfering current level in presence of a primary monopolar and hexapolar stimulus. On the other hand, hexapolar interference did not alter activation thresholds at the primary site. CONCLUSIONS: Hexapolar stimulation reduces electric cross-talk between neighboring sites and represents a technique to reduce interference between individual stimulation sites. In contrast, concurrent monopolar stimulation produces a reduction of the activation threshold of stimuli delivered nearby. Thus, a single source of subthreshold monopolar charge injection can provide benefit in the form of significant threshold reduction simultaneously at multiple stimulation sites.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Interim results from the international trial of Second Sight's visual prosthesis
Humayun, M. S., Dorn, J. D., da Cruz, L., Dagnelie, G., Sahel, J.-A., Stanga, P. E., Cideciyan, A. V., Duncan, J. L., Eliott, D., Filley, E., et al. (2012) · Ophthalmology · doi:10.1016/j.ophtha.2011.09.028 · Cited by 700
First-in-human trial of a novel suprachoroidal retinal prosthesis
Ayton, L. N., Blamey, P. J., Guymer, R. H., Luu, C. D., Nayagam, D. A. X., Sinclair, N. C., Shivdasani, M. N., Yeoh, J., McCombe, M. F., Briggs, R. J., et al. (2014) · PLoS ONE · doi:10.1371/journal.pone.0115239 · Cited by 333
The functional performance of the Argus II retinal prosthesis
Stronks, H. C., & Dagnelie, G. (2014) · Expert Review of Medical Devices · doi:10.1586/17434440.2014.862494 · Cited by 189
Current steering creates additional pitch percepts in adult cochlear implant recipients
Firszt, J. B., Koch, D. B., Downing, M., & Litvak, L. (2007) · Otology & Neurotology · doi:10.1097/01.mao.0000281803.36574.bc · Cited by 150
Electric crosstalk impairs spatial resolution of multi-electrode arrays in retinal implants
Wilke, R. G. H., Moghadam, G. K., Lovell, N. H., Suaning, G. J., & Dokos, S. (2011) · Journal of Neural Engineering · doi:10.1088/1741-2560/8/4/046016 · Cited by 110 · cited 1×
“In the literature, this also is referred to as cross-talk.(11,17) Approaches to reduce interference from concomitant stimulation have considered spatial isolation of stimuli by confining the electric field using current focusing techniques,(9,18,19) time-multiplexing strategies,(1,20,21) or both.”
BackgroundSelf-citationFocal activation of the feline retina via a suprachoroidal electrode array
Wong, Y. T., Chen, S. C., Seo, J. M., Morley, J. W., Lovell, N. H., & Suaning, G. J. (2009) · Vision Research · doi:10.1016/j.visres.2009.02.018 · Cited by 109
Self-citationSpatiotemporal Interactions in Retinal Prosthesis Subjects
Horsager, A., Greenberg, R. J., & Fine, I. (2010) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.09-3746 · Cited by 95
Current steering in retinal stimulation via a quasimonopolar stimulation paradigm
Matteucci, P. B., Chen, S. C., Tsai, D., Dodds, C. W. D., Dokos, S., Morley, J. W., Lovell, N. H., & Suaning, G. J. (2013) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.13-11653 · Cited by 79 · cited 3×
“In a previous study, the QMP stimulation paradigm was presented whereby return current was shared between a distant monopolar electrode and a surrounding hexapolar guard.(9) The QMP approach possessed the low-threshold characteristics of monopolar stimulation and the contained and focused retinal activation of hexapol…”
MethodInfluentialSelf-citationFactors Affecting Perceptual Thresholds in a Suprachoroidal Retinal Prosthesis
Shivdasani, M. N., Sinclair, N. C., Dimitrov, P. N., Varsamidis, M., Ayton, L. N., Luu, C. D., Perera, T., McDermott, H. J., & Blamey, P. J. (2014) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.14-14396 · Cited by 78
McCreery, D. B., Agnew, W. F., & Bullara, L. A. (2002) · Annals of Biomedical Engineering · doi:10.1114/1.1430748 · Cited by 77
Cited by
Development of visual Neuroprostheses: trends and challenges.
Fernandez, E. (2018) · Bioelectronic Medicine · doi:10.1186/s42234-018-0013-8 · Cited by 114
Visual prosthesis: interfacing stimulating electrodes with retinal neurons to restore vision.
Barriga-Rivera, A., Bareket, L., Goding, J., Aregueta-Robles, U. A., & Suaning, G. J. (2017) · Frontiers in Neuroscience · doi:10.3389/fnins.2017.00620 · Cited by 73
“Despite its contribution to complex phosphenes, electric crosstalk can be beneficial, as it may reduce activation thresholds due to field summation (Matteucci et al., 2016), or may inhibit neural activation as the effective overlap of electric fields bring the extracellular potential above the…”
BackgroundInfluentialSelf-citationStimulation strategies for improving the resolution of retinal prostheses
Tong, W., Meffin, H., Garrett, D. J., & Ibbotson, M. R. (2020) · Frontiers in Neuroscience · doi:10.3389/fnins.2020.00262 · Cited by 66
Optimization of return electrodes in neurostimulating arrays
Flores, T., Goetz, G., Lei, X., & Palanker, D. (2016) · Journal of Neural Engineering · doi:10.1088/1741-2560/13/3/036010 · Cited by 43
Spencer, T. C., Fallon, J. B., Thien, P. C., & Shivdasani, M. N. (2016) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.16-19325 · Cited by 31
Metadata
- Authors
- Matteucci, P. B., Barriga-Rivera, A., Eiber, C. D., Lovell, N. H., Morley, J. W., & Suaning, G. J.
- Venue
- Investigative Opthalmology & Visual Science
- Published
- 2016-03-08
- Volume
- 57
- Issue
- 3
- Pages
- 1031
- ISSN
- 0146-0404 (ISSN-L)
- 1552-5783
- OpenAlex
- W2294624352
- Cited by
- 39
- References
- 12
- FWCI
- 3.58
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: The Effect of Electric Cross-Talk in Retinal Neurostimulation. https://app.cochat.ai/papers/10.1167/iovs.15-18400
- The paper
- Matteucci, P. B., Barriga-Rivera, A., Eiber, C. D., Lovell, N. H., Morley, J. W., & Suaning, G. J. (2016). The Effect of Electric Cross-Talk in Retinal Neurostimulation. Investigative Opthalmology & Visual Science. https://doi.org/10.1167/iovs.15-18400
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.