Analyzing a Portion of the ROC Curve
The DOI matches its Crossref record; 14 of the 14 references it cites were found in a registry or an index.
Abstract
The area under the ROC curve is a common index summarizing the information contained in the curve. When comparing two ROC curves, though, problems arise when interest does not lie in the entire range of false-positive rates (and hence the entire area). Numerical integration is suggested for evaluating the area under a portion of the ROC curve. Variance estimates are derived. The method is applicable for either continuous or rating scale binormal data, from independent or dependent samples. An example is presented which looks at rating scale data of computed tomographic scans of the head with and without concomitant use of clinical history. The areas under the two ROC curves over an a priori range of false- positive rates are examined, as well as the areas under the two curves at a specific point.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
(1982) · Cited by 1,288
I., E., Gerald, C. F., & Wheatley, P. O. (1985) · Mathematics of Computation · doi:10.2307/2007813 · Cited by 1,012
Dorfman, D. D., & Alf, E. (1969) · Journal of Mathematical Psychology · doi:10.1016/0022-2496(69)90019-4 · Cited by 874
ROC Analysis Applied to the Evaluation of Medical Imaging Techniques
SWETS, J. A. (1979) · Investigative Radiology · doi:10.1097/00004424-197903000-00002 · Cited by 699
The use of relative operating characteristic (ROC) curves in test performance evaluation.
Beck, & Shultz, E. K. (1986) · PubMed · Cited by 621
Survival Models and Data Analysis
Khuri, A. I. (1981) · Journal of Quality Technology · doi:10.1080/00224065.1981.11978771 · Cited by 602
Statistical Approaches to the Analysis of Receiver Operating Characteristic (ROC) Curves
McNeil, B. J., & Hanley, J. A. (1984) · Medical Decision Making · doi:10.1177/0272989x8400400203 · Cited by 556
Swets, J. A. (1986) · Psychological Bulletin · doi:10.1037//0033-2909.99.2.181 · Cited by 508
Metz, C. E., Wang, P.-L., & Kronman, H. B. (1984) · Information Processing in Medical Imaging · doi:10.1007/978-94-009-6045-9_25 · Cited by 356
The Robustness of the "Binormal" Assumptions Used in Fitting ROC Curves
Hanley, J. A. (1988) · Medical Decision Making · doi:10.1177/0272989x8800800308 · Cited by 309
Cited by
pROC: an open-source package for R and S+ to analyze and compare ROC curves
Robin, X., Turck, N., Hainard, A., Tiberti, N., Lisacek, F., Sanchez, J.-C., & Müller, M. (2011) · BMC Bioinformatics · doi:10.1186/1471-2105-12-77 · Cited by 13,697
Receiver-operating characteristic (ROC) plots: a fundamental evaluation tool in clinical medicine
Zweig, M. H., & Campbell, G. (1993) · Clinical Chemistry · doi:10.1093/clinchem/39.4.561 · Cited by 6,569
(2013) · Europe PMC (PubMed Central) · Cited by 2,089
Phases of Biomarker Development for Early Detection of Cancer
Pepe, M. S., Etzioni, R., Feng, Z., Potter, J. D., Thompson, M. L., Thornquist, M., Winget, M., & Yasui, Y. (2001) · JNCI Journal of the National Cancer Institute · doi:10.1093/jnci/93.14.1054 · Cited by 1,686
“Histograms and receiver operating characteristic (ROC) curve for a cancer antigen, CA 19 – 9, as a biomarker for pancreatic cancer (14).”
Receiver-operating characteristic analysis for evaluating diagnostic tests and predictive models
Zou, K. H., O’Malley, A. J., & Mauri, L. (2007) · Circulation · doi:10.1161/circulationaha.105.594929 · Cited by 1,473
The Efficacy of Diagnostic Imaging
Fryback, D. G., & Thornbury, J. R. (1991) · Medical Decision Making · doi:10.1177/0272989x9101100203 · Cited by 1,291
Measuring classifier performance: a coherent alternative to the area under the ROC curve
Hand, D. J. (2009) · Machine Learning · doi:10.1007/s10994-009-5119-5 · Cited by 1,003
Translational biomarker discovery in clinical metabolomics: an introductory tutorial
Xia, J., Broadhurst, D. I., Wilson, M., & Wishart, D. S. (2013) · Metabolomics · doi:10.1007/s11306-012-0482-9 · Cited by 953
Receiver Operating Characteristic (ROC) Curve: Practical Review for Radiologists
Park, S. H., Goo, J. M., & Jo, C.-H. (2004) · Korean Journal of Radiology · doi:10.3348/kjr.2004.5.1.11 · Cited by 907
Receiver Operating Characteristic Curves and Their Use in Radiology
Obuchowski, N. A. (2003) · Radiology · doi:10.1148/radiol.2291010898 · Cited by 843
The use of receiver operating characteristic curves in biomedical informatics
Lasko, T. A., Bhagwat, J. G., Zou, K. H., & Ohno-Machado, L. (2005) · Journal of Biomedical Informatics · doi:10.1016/j.jbi.2005.02.008 · Cited by 823
Guidelines for Meta-analyses Evaluating Diagnostic Tests
Irwig, L., Tosteson, A. N. A., Gatsonis, C., Lau, J., Colditz, G., Chalmers, T. C., & Mosteller, F. (1994) · Annals of Internal Medicine · doi:10.7326/0003-4819-120-8-199404150-00008 · Cited by 753
Journal of Statistical Planning and Inference, the
(2005) · Encyclopedia of Statistical Sciences · doi:10.1002/0471667196.ess1316 · Cited by 720
Statistical Evaluation of Prognostic versus Diagnostic Models: Beyond the ROC Curve
Cook, N. R. (2008) · Clinical Chemistry · doi:10.1373/clinchem.2007.096529 · Cited by 691
Properties of the summary receiver operating characteristic (SROC) curve for diagnostic test data
Walter, S. D. (2002) · Statistics in Medicine · doi:10.1002/sim.1099 · Cited by 672
A deep learning system for detecting diabetic retinopathy across the disease spectrum
Dai, L., Wu, L., Li, H., Cai, C., Wu, Q., Kong, H., Liu, R., Wang, X., Hou, X., Liu, Y., et al. (2021) · Nature Communications · doi:10.1038/s41467-021-23458-5 · Cited by 620
“The AUCs were compared using binormal model methods 59 , where a two-sided P value of less than 0.05 was considered statistically signi fi cant.”
MethodInfluentialTranscriptional Basis of Mouse and Human Dendritic Cell Heterogeneity
Brown, C. C., Gudjonson, H., Pritykin, Y., Deep, D., Lavallée, V.-P., Mendoza, A., Fromme, R., Mazutis, L., Ariyan, C., Leslie, C., et al. (2019) · Cell · doi:10.1016/j.cell.2019.09.035 · Cited by 601
Chicco, D., & Jurman, G. (2023) · BioData Mining · doi:10.1186/s13040-023-00322-4 · Cited by 597
Obuchowski, N. A., & Bullen, J. A. (2018) · Physics in Medicine & Biology · doi:10.1088/1361-6560/aab4b1 · Cited by 542
Jones, C. M., & Athanasiou, T. (2005) · The Annals of Thoracic Surgery · doi:10.1016/j.athoracsur.2004.09.040 · Cited by 523
Statistical Evaluation of a Biomarker
Ray, P., Manach, Y. L., Riou, B., Houle, T. T., & Warner, D. S. (2010) · Anesthesiology · doi:10.1097/aln.0b013e3181d47604 · Cited by 503
Two-Branch Recurrent Network for Isolating Deepfakes in Videos
Masi, I., Killekar, A., Mascarenhas, R. M., Gurudatt, S. P., & AbdAlmageed, W. (2020) · Lecture Notes in Computer Science · doi:10.1007/978-3-030-58571-6_39 · Cited by 471
Meta-analytic methods for diagnostic test accuracy
Irwig, L., Macaskill, P., Glasziou, P., & Fahey, M. (1995) · Journal of Clinical Epidemiology · doi:10.1016/0895-4356(94)00099-c · Cited by 467
Measuring and comparing the accuracy of species distribution models with presence–absence data
Liu, C., White, M., & Newell, G. (2011) · Ecography · doi:10.1111/j.1600-0587.2010.06354.x · Cited by 456
Combining GFR and Albuminuria to Classify CKD Improves Prediction of ESRD
Hallan, S. I., Ritz, E., Lydersen, S., Romundstad, S., Kvenild, K., & Orth, S. R. (2009) · Journal of the American Society of Nephrology · doi:10.1681/asn.2008070730 · Cited by 439
The interpretation of diagnostic tests
Shapiro, D. E. (1999) · Statistical Methods in Medical Research · doi:10.1177/096228029900800203 · Cited by 383
easyROC: An Interactive Web-tool for ROC Curve Analysis Using R Language Environment
Goksuluk, D., Korkmaz, S., Zararsiz, G., & Karaagaoglu, A. (2016) · The R Journal · doi:10.32614/rj-2016-042 · Cited by 377
The diagnostic value of biomarkers (SteatoTest) for the prediction of liver steatosis
Poynard, T., Ratziu, V., Naveau, S., Thabut, D., Charlotte, F., Messous, D., Capron, D., Abella, A., Massard, J., Ngo, Y., et al. (2005) · Comparative Hepatology · doi:10.1186/1476-5926-4-10 · Cited by 368
ROC Curves in Clinical Chemistry: Uses, Misuses, and Possible Solutions
Obuchowski, N. A., Lieber, M. L., & Wians, F. H. (2004) · Clinical Chemistry · doi:10.1373/clinchem.2004.031823 · Cited by 358
“…the average sensitivity for the range of FPRs that is useful clinically (e.g., average sensitivity when the FPR is " 0.10) or the average specificity for the range of sensitivities useful clinically (e.g., average specificity when sensitivity is # 0.90), i.e., the partial area index (36 , 37) .”
BackgroundInfluentialLi, J., Xie, H., Li, J., Wang, Z., & Zhang, Y. (2021) · 2021 IEEE/CVF Conference on Computer Vision and Pattern Recognition (CVPR) · doi:10.1109/cvpr46437.2021.00639 · Cited by 357
Partial AUC Estimation and Regression
Dodd, L. E., & Pepe, M. S. (2003) · Biometrics · doi:10.1111/1541-0420.00071 · Cited by 346
Carrington, A. M., Manuel, D. G., Fieguth, P. W., Ramsay, T., Osmani, V., Wernly, B., Bennett, C., Hawken, S., Magwood, O., Sheikh, Y., et al. (2023) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/tpami.2022.3145392 · Cited by 339
Belinson, J., Qiao, Y. L., Pretorius, R., Zhang, W. H., Elson, P., Li, L., Pan, Q. J., Fischer, C., Lorincz, A., & Zahniser, D. (2001) · Gynecologic Oncology · doi:10.1006/gyno.2001.6370 · Cited by 337
Receiver operating characteristic (ROC) analysis: Basic principles and applications in radiology
van Erkel, A. R., & Pattynama, P. M. T. (1998) · European Journal of Radiology · doi:10.1016/s0720-048x(97)00157-5 · Cited by 327
AUC Maximization in the Era of Big Data and AI: A Survey
Yang, T., & Ying, Y. (2023) · ACM Computing Surveys · doi:10.1145/3554729 · Cited by 323
Obuchowski (2005) · doi:10.2214/ajr.184.2.01840364 · Cited by 321
A review of data-driven fault detection and diagnostics for building HVAC systems
Chen, Z., O’Neill, Z., Wen, J., Pradhan, O., Yang, T., Lu, X., Lin, G., Miyata, S., Lee, S., Shen, C., et al. (2023) · Applied Energy · doi:10.1016/j.apenergy.2023.121030 · Cited by 311
Estimation and Comparison of Receiver Operating Characteristic Curves
Pepe, M. S., Longton, G., & Janes, H. (2009) · The Stata Journal: Promoting communications on statistics and Stata · doi:10.1177/1536867x0900900101 · Cited by 306
Tuning metal single atoms embedded in NxCy moieties toward high-performance electrocatalysis
Ha, M., Kim, D. Y., Umer, M., Gladkikh, V., Myung, C. W., & Kim, K. S. (2021) · Energy & Environmental Science · doi:10.1039/d1ee00154j · Cited by 305
Review of Pavement Defect Detection Methods
Cao, W., Liu, Q., & He, Z. (2020) · IEEE Access · doi:10.1109/access.2020.2966881 · Cited by 304
Combining diagnostic test results to increase accuracy
Pepe, M. S. (2000) · Biostatistics · doi:10.1093/biostatistics/1.2.123 · Cited by 303
The Performance of Risk Prediction Models
Gerds, T. A., Cai, T., & Schumacher, M. (2008) · Biometrical Journal · doi:10.1002/bimj.200810443 · Cited by 288
Metz, C. E. (2006) · Journal of the American College of Radiology · doi:10.1016/j.jacr.2006.02.021 · Cited by 274
“Proper” Binormal ROC Curves: Theory and Maximum-Likelihood Estimation
Metz, C. E., & Pan, X. (1999) · Journal of Mathematical Psychology · doi:10.1006/jmps.1998.1218 · Cited by 273
Halligan, S., Altman, D. G., & Mallett, S. (2015) · European Radiology · doi:10.1007/s00330-014-3487-0 · Cited by 255
“The less good a test at discriminating between patients with and without an abnormality, the more the two distributions will overlap of thresholds via “ partial ” AUC (pAUC) is possible [12] but choosing a single important threshold is usually more practical.”
BackgroundAn ensemble learning framework for anomaly detection in building energy consumption
Araya, D. B., Grolinger, K., ElYamany, H. F., Capretz, M. A. M., & Bitsuamlak, G. (2017) · Energy and Buildings · doi:10.1016/j.enbuild.2017.02.058 · Cited by 254
Obayashi, T., Aoki, Y., Tadaka, S., Kagaya, Y., & Kinoshita, K. (2018) · Plant and Cell Physiology · doi:10.1093/pcp/pcx191 · Cited by 252
“01, which is the area under a part of the receiver operating characteristic curve with a false-positive rate of 0.01 (McClish 1989).”
BackgroundInfluentialBenner, C., Havulinna, A. S., Järvelin, M.-R., Salomaa, V., Ripatti, S., & Pirinen, M. (2017) · The American Journal of Human Genetics · doi:10.1016/j.ajhg.2017.08.012 · Cited by 242
“cording to their achieved TPR versus FPR through the partial area under the curve (pAUC).(32) AUC is defined as the area under the TPR-versus-FPR curve and can be interpreted as the probability”
MethodSignal Detectability: The Use of ROC Curves and Their Analyses
Centor, R. M. (1991) · Medical Decision Making · doi:10.1177/0272989x9101100205 · Cited by 239
Obuchowski, N. A., & Rockette, H. E. (1995) · Communications in Statistics - Simulation and Computation · doi:10.1080/03610919508813243 · Cited by 234
Selecting Differentially Expressed Genes from Microarray Experiments
Pepe, M. S., Longton, G., Anderson, G. L., & Schummer, M. (2003) · Biometrics · doi:10.1111/1541-0420.00016 · Cited by 207
“The partial area under the curve, pAUC( t 0 ), in effect averages this proportion across values of t t 0 (McClish, 1989).”
Rizzo, L., Calvaruso, V., Cacopardo, B., Alessi, N., Attanasio, M., Petta, S., Fatuzzo, F., Montineri, A., Mazzola, A., L'abbate, L., et al. (2011) · American Journal of Gastroenterology · doi:10.1038/ajg.2011.341 · Cited by 200
“Partial AUROC analysis for TE and ARFI has been calculated as previously proposed by McClish (”
MethodA Blood-Based Proteomic Classifier for the Molecular Characterization of Pulmonary Nodules
Li, X.-J., Hayward, C., Fong, P.-Y., Dominguez, M., Hunsucker, S. W., Lee, L. W., McLean, M., Law, S., Butler, H., Schirm, M., et al. (2013) · Science Translational Medicine · doi:10.1126/scitranslmed.3007013 · Cited by 192
“The receiver operating characteristic (ROC) curve and the corresponding area under the curve (AUC) of the classifier on the discovery samples are reported in fig.”
MethodInfluentialFagan, A. M., Shaw, L. M., Xiong, C., Vanderstichele, H., Mintun, M. A., Trojanowski, J. Q., Coart, E., Morris, J. C., & Holtzman, D. M. (2011) · Archives of Neurology · doi:10.1001/archneurol.2011.105 · Cited by 189
“5) LP to PiB range, d 0-719 LP same d or prior to PiB, % (range, d) 80 (0-719) LP after PiB, % (range, d) 20 (1-400)”
Assessing the Performance of Classification Methods
Hand, D. J. (2012) · International Statistical Review · doi:10.1111/j.1751-5823.2012.00183.x · Cited by 177
Mirabello, L., Schiffman, M., Ghosh, A., Rodriguez, A. C., Vasiljevic, N., Wentzensen, N., Herrero, R., Hildesheim, A., Wacholder, S., Scibior‐Bentkowska, D., et al. (2013) · International Journal of Cancer · doi:10.1002/ijc.27750 · Cited by 165
“5.(21) Analyses were performed using SPSS 15.”
A Guide for the Design of Evolve and Resequencing Studies
Kofler, R., & Schlötterer, C. (2014) · Molecular Biology and Evolution · doi:10.1093/molbev/mst221 · Cited by 163
Sample Size Tables For Receiver Operating Characteristic Studies
Obuchowski, N. A. (2000) · American Journal of Roentgenology · doi:10.2214/ajr.175.3.1750603 · Cited by 159
“It is a good global measure of accuracy [2]; however, for particular clinical applications, we are usually interested in only a certain portion of the ROC curve [3].”
BackgroundBeam, C. A., Conant, E. F., & Sickles, E. A. (2003) · JNCI Journal of the National Cancer Institute · doi:10.1093/jnci/95.4.282 · Cited by 158
Caveats and pitfalls of ROC analysis in clinical microarray research (and how to avoid them)
Berrar, D., & Flach, P. (2012) · Briefings in Bioinformatics · doi:10.1093/bib/bbr008 · Cited by 136
Mental health screening in addiction, corrections and social service settings: Validating the MMS
Alexander, M. J., Haugland, G., Lin, S. P., Bertollo, D. N., & McCorry, F. A. (2008) · International Journal of Mental Health and Addiction · doi:10.1007/s11469-007-9100-x · Cited by 71
“The areas under the curve for each target group were compared with each other using a test of z scores (McClish 1989).”
MethodMethods for assessing accuracy and reliability in functional MRI
Le, T. H., & Hu, X. P. (1997) · NMR in Biomedicine · doi:10.1002/(sici)1099-1492(199706/08)10:4/5<160::aid-nbm458>3.0.co;2-a · Cited by 49
ALCOdb: Gene Coexpression Database for Microalgae
Aoki, Y., Okamura, Y., Ohta, H., Kinoshita, K., & Obayashi, T. (2016) · Plant and Cell Physiology · doi:10.1093/pcp/pcv190 · Cited by 43
Zilker, S., Weinzierl, S., Kraus, M., Zschech, P., & Matzner, M. (2024) · Health Care Management Science · doi:10.1007/s10729-024-09673-8 · Cited by 29
“AUC ROC determines how well a classifier can distinguish between classes [75], and remains unbiased when dealing with highly imbalanced class distributions [76].”
BackgroundKusa, W., Lipani, A., Knoth, P., & Hanbury, A. (2023) · Intelligent Systems with Applications · doi:10.1016/j.iswa.2023.200193 · Cited by 21
“An alternative can be to calculate partial AUC score (pAUC), a practice for highly sensitive diagnostic tests (McClish, 1989, Jiang et al., 1996).”
Metadata
- Authors
- McClish, D. K.
- Venue
- Medical Decision Making
- Publisher
- SAGE Publications
- Published
- 1989-08
- Volume
- 9
- Issue
- 3
- Pages
- 190-195
- ISSN
- 0272-989X (ISSN-L)
- 1552-681X
- OpenAlex
- W2078622638
- Cited by
- 707
- References
- 14
- FWCI
- 5.05
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.