The DOI matches its Crossref record; 48 of the 48 references it cites were found in a registry or an index.
Graft Fixation in Cruciate Ligament Reconstruction
Abstract
Cruciate ligament reconstruction has progressed dramatically in the last 20 years. Anatomic placement of ligament substitutes has fostered rehabilitation efforts that stress immediate and full range of motion, immediate weightbearing, neuromuscular strength and coordination, and early return to athletic competition (3 months). This has placed extreme importance on secure graft fixation at the time of ligament reconstruction. Current ligament substitutes require a bony or soft tissue component to be fixed within a bone tunnel or on the periosteum at a distance from the normal ligament attachment site. Fixation devices have progressed from metal to biodegradable and from far to near-normal native ligament attachment sites. Ideally, the biomechanical properties of the entire graft construct would approach those of the native ligament and facilitate biologic incorporation of the graft. Fixation should be done at the normal anatomic attachment site of the native ligament (aperture fixation) and, over time, allow the biologic return of the histologic transition zone from ligament to fibrocartilage, to calcified fibrocartilage, to bone. The purpose of this article is to review current fixation devices and techniques in cruciate ligament surgery.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Biomechanical analysis of human ligament grafts used in knee-ligament repairs and reconstructions.
Noyes, F. R., Butler, D. L., Grood, E. S., Zernicke, R. F., & Hefzy, M. S. (1984) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-198466030-00005 · Cited by 1,524
Woo, S. L.-Y., Hollis, J. M., Adams, D. J., Lyon, R. M., & Takai, S. (1991) · The American Journal of Sports Medicine · doi:10.1177/036354659101900303 · Cited by 1,196
Tendon-healing in a bone tunnel. A biomechanical and histological study in the dog.
Rodeo, S. A., Arnoczky, S. P., Torzilli, P. A., Hidaka, C., & Warren, R. F. (1993) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-199312000-00009 · Cited by 1,104
The mechanics of the knee joint in relation to normal walking
Morrison, J. B. (1970) · Journal of Biomechanics · doi:10.1016/0021-9290(70)90050-3 · Cited by 1,055
Late degradation tissue response to poly(?-lactide) bone plates and screws
Bergsma, J. (1995) · Biomaterials · doi:10.1016/0142-9612(95)91092-d · Cited by 799
Kurosaka, M., Yoshiya, S., & Andrish, J. T. (1987) · The American Journal of Sports Medicine · doi:10.1177/036354658701500306 · Cited by 745
Anterior and posterior cruciate ligament reconstruction in rhesus monkeys.
Clancy, W. G., Narechania, R. G., Rosenberg, T. D., Gmeiner, J. G., Wisnefske, D. D., & Lange, T. A. (1981) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-198163080-00008 · Cited by 703
HAMNER, D. L., BROWN, C. H., STEINER, M. E., HECKER, A. T., & HAYES, W. C. (1999) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-199904000-00013 · Cited by 633
Self-citationDaniels, A. U., Chang, M. K. O., Andriano, K. P., & Heller, J. (1990) · Journal of Applied Biomaterials · doi:10.1002/jab.770010109 · Cited by 483
Arthroscopic Reconstruction of the Anterior Cruciate Ligament
Corry, I. S., Webb, J. M., Clingeleffer, A. J., & Pinczewski, L. A. (1999) · The American Journal of Sports Medicine · doi:10.1177/03635465990270040701 · Cited by 462
[Arthroscopic reconstruction of anterior cruciate ligament].
Kristensen, G. (2005) · PubMed · Cited by 457
The mechanical properties of the two bundles of the human posterior cruciate ligament
Race, A., & Amis, A. A. (1994) · Journal of Biomechanics · doi:10.1016/0021-9290(94)90028-0 · Cited by 452
L’Insalata, J. C., Klatt, B., Fu, F. H., & Harner, C. D. (1997) · Knee Surgery, Sports Traumatology, Arthroscopy · doi:10.1007/s001670050056 · Cited by 432
Shelbourne, K. D., & Gray, T. (1997) · The American Journal of Sports Medicine · doi:10.1177/036354659702500610 · Cited by 413
Fu, F. H., Bennett, C. H., Ma, C. B., Menetrey, J., & Lattermann, C. (2000) · The American Journal of Sports Medicine · doi:10.1177/03635465000280010801 · Cited by 412
Anterior Cruciate Ligament Graft Fixation: Comparison of Hamstring and Patellar Tendon Grafts
Steiner, M. E., Hecker, A. T., Brown, C. H., & Hayes, W. C. (1994) · The American Journal of Sports Medicine · doi:10.1177/036354659402200215 · Cited by 398
Self-citationFunction of the knee joint in various activities.
Morrison, J. B. (1969) · PubMed · Cited by 319
An Analysis of Autograft Fixation After Anterior Cruciate Ligament Reconstruction in a Rabbit Model
Grana, W. A., Egle, D. M., Mahnken, R., & Goodhart, C. W. (1994) · The American Journal of Sports Medicine · doi:10.1177/036354659402200309 · Cited by 317
Ishibashi, Y., Rudy, T. W., Livesay, G. A., Stone, J. D., Fu, F. H., & Woo, S. L.-Y. (1997) · Arthroscopy: The Journal of Arthroscopic & Related Surgery · doi:10.1016/s0749-8063(97)90152-3 · Cited by 285
Fixation with bioabsorbable screws for the treatment of fractures of the ankle.
Bucholz, R. W., Henry, S., & Henley, M. B. (1994) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-199403000-00001 · Cited by 271
The strength of the central third patellar. tendon graft: A biomechanical study
Cooper, D. E., Deng, X. H., Burstein, A. L., & Warren, R. F. (1993) · The American Journal of Sports Medicine · doi:10.1177/036354659302100610 · Cited by 264
Nebelung, W. (1998) · Arthroscopy: The Journal of Arthroscopic & Related Surgery · doi:10.1016/s0749-8063(98)70015-5 · Cited by 234
LAMBERT, K. L. (1983) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-198301000-00016 · Cited by 228
Vuori, I., Heinonen, A., Siev�nen, H., Kannus, P., Pasanen, M., & Oja, P. (1994) · Calcified Tissue International · doi:10.1007/bf00310170 · Cited by 207
Poly (l-lactide): a long-term degradation study in vivo
Pistner, H., Bendi, D. R., Mühling, J., & Reuther, J. F. (1993) · Biomaterials · doi:10.1016/0142-9612(93)90121-h · Cited by 205
Hamstring tendon fixation using interference screws: a biomechanical study in calf tibial bone
Weiler, A., Hoffmann, R., Stähelin, A., Bail, H., Siepe, C., & Südkamp, N. (1998) · Arthroscopy: The Journal of Arthroscopic & Related Surgery · doi:10.1016/s0749-8063(98)70117-3 · Cited by 201
Self-citationWeiler, A., Windhagen, H. J., Raschke, M. J., Laumeyer, A., & Hoffmann, R. F. G. (1998) · The American Journal of Sports Medicine · doi:10.1177/03635465980260010401 · Cited by 196
Self-citationHöher, J., Livesay, G. A., Ma, C. B., Withrow, J. D., Fu, F. H., & Woo, S. L. (1999) · Knee Surgery, Sports Traumatology, Arthroscopy · doi:10.1007/s001670050151 · Cited by 194
Stäubli, H. ‐., Schatzmann, L., Brunner, P., Rincón, L., & Nolte, L. ‐. (1996) · Knee Surgery, Sports Traumatology, Arthroscopy · doi:10.1007/bf01477262 · Cited by 191
BÖSTMAN, O. M. (1992) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-199205000-00031 · Cited by 185
Clark, R., Olsen, R., Larson, B., Goble, E. M., & Farrer, R. (1998) · Arthroscopy The Journal of Arthroscopic and Related Surgery · doi:10.1016/s0749-8063(98)70141-0 · Cited by 182
Preliminary results of an absorbable interference screw
Barber, F. A., Elrod, B. F., McGuire, D. A., & Paulos, L. E. (1995) · Arthroscopy · doi:10.1016/0749-8063(95)90129-9 · Cited by 178 · cited 1×
“clinical studies have reported no significant difference in clinical outcome.(3,31,60)”
ResultAnalysis of a Semitendinosus Autograft in a Rabbit Model
Blickenstaff, K. R., Grana, W. A., & Egle, D. (1997) · The American Journal of Sports Medicine · doi:10.1177/036354659702500420 · Cited by 164 · cited 1×
“In a recent animal study there was evidence that the healing under interference screw compression follows different patterns than what has been described in animal models using noncompressing extraarticular fixation techniques.(7,34,73,92) In this animal model, Weiler et al.”
ResultRevision Anterior Cruciate Ligament Surgery: Experience From Miami
Uribe, J. W., Hechtman, K. S., Zvijac, J. E., & Tjin-A-Tsoi, E. W. (1996) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-199604000-00010 · Cited by 162
Rowden, N. J., Sher, D., Rogers, G. J., & Schindhelm, K. (1997) · The American Journal of Sports Medicine · doi:10.1177/036354659702500409 · Cited by 161
Weiler, A., Helling, H.-J., Kirch, U., et al. (1996) · PubMed · Cited by 156
Self-citationPena, F. A., Grøntvedt, T., Brown, G. A., Aune, A. K., & Engebretsen, L. (1996) · The American Journal of Sports Medicine · doi:10.1177/036354659602400314 · Cited by 155
Isometry testing for anterior cruciate ligament reconstruction revisited
Morgan, C. D., Kalmam, V. R., & Grawl, D. M. (1995) · Arthroscopy The Journal of Arthroscopic and Related Surgery · doi:10.1016/0749-8063(95)90104-3 · Cited by 150
The biomechanics of interference screw fixation of patellar tendon anterior cruciate ligament grafts
Brown, C. H., Hecker, A. T., Hipp, J. A., Myers, E. R., & Hayes, W. C. (1993) · The American Journal of Sports Medicine · doi:10.1177/036354659302100622 · Cited by 147
Self-citationMechanical characterization of biodegradable implants
Claes, L. (1992) · Clinical Materials · doi:10.1016/0267-6605(92)90083-6 · Cited by 142
Markolf, K. L., Burchfield, D. M., Shapiro, M. M., et al. (1996) · Journal of Bone and Joint Surgery · doi:10.2106/00004623-199611000-00014 · Cited by 141
Stähelin, A. C., Weiler, A., Rüfenacht, H., Hoffmann, R. F. G., Geissmann, A., & Feinstein, R. S. (1997) · Arthroscopy The Journal of Arthroscopic and Related Surgery · doi:10.1016/s0749-8063(97)90162-6 · Cited by 134
Self-citationForeign‐Body Reaction to the Bioabsorbable Suretac Device
Burkart, A., Imhoff, A. B., & Roscher, E. (2000) · Arthroscopy The Journal of Arthroscopic and Related Surgery · doi:10.1016/s0749-8063(00)90134-8 · Cited by 125
Rupp, S., Krauss, P. W., & Fritsch, E. W. (1997) · Arthroscopy The Journal of Arthroscopic and Related Surgery · doi:10.1016/s0749-8063(97)90210-3 · Cited by 120
Biodegradable rods versus Kirschner wire fixation of wrist fractures. A randomised trial
Pp, C., Handelberg, F., & Haentjens, P. (1992) · Journal of Bone and Joint Surgery - British Volume · doi:10.1302/0301-620x.74b6.1332974 · Cited by 110
Hulstyn, M. J., Fadale, P. D., Abate, J., & Walsh, W. R. (1993) · Arthroscopy The Journal of Arthroscopic and Related Surgery · doi:10.1016/s0749-8063(05)80316-0 · Cited by 91
Marti, C. B., Imhoff, A. B., Bahrs, C., & Roméro, J. (1997) · Knee Surgery Sports Traumatology Arthroscopy · doi:10.1007/s001670050053 · Cited by 80
Local foreign-body reactions to biodegradable implants
Hoffmann, R. F. G., Weiler, A., Helling, H. J., Krettek, C., & Rehm, K. E. (1997) · Der Unfallchirurg · doi:10.1007/s001130050172 · Cited by 52
Self-citation
Cited by
Treatment of Anterior Cruciate Ligament Injuries, Part I
Beynnon, B. D., Johnson, R. J., Abate, J. A., Fleming, B. C., & Nichols, C. E. (2005) · The American Journal of Sports Medicine · doi:10.1177/0363546505279913 · Cited by 638
Tendon healing in a bone tunnel. Part II
Weiler, A., Hoffmann, R. F. G., Bail, H. J., Rehm, O., & Südkamp, N. P. (2002) · Arthroscopy: The Journal of Arthroscopic & Related Surgery · doi:10.1053/jars.2002.30657 · Cited by 481
Self-citationKousa, P., Järvinen, T. L. N., Vihavainen, M., Kannus, P., & Järvinen, M. (2003) · The American Journal of Sports Medicine · doi:10.1177/03635465030310020401 · Cited by 426
Engineering Orthopedic Tissue Interfaces
Yang, P. J., & Temenoff, J. S. (2009) · Tissue Engineering Part B: Reviews · doi:10.1089/ten.teb.2008.0371 · Cited by 294
Metadata
- Authors
- Brand, J., Weiler, A., Caborn, D. N. M., Brown, C. H., & Johnson, D. L.
- Venue
- The American Journal of Sports Medicine
- Publisher
- SAGE Publications
- Published
- 2000-09
- Volume
- 28
- Issue
- 5
- Pages
- 761-774
- ISSN
- 0363-5465 (ISSN-L)
- 1552-3365
- OpenAlex
- W2164678492
- Cited by
- 436
- References
- 48
- FWCI
- 11.27
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.