Quantitative X-ray tomography
Open accessThe DOI matches its Crossref record; 136 of the 136 references it cites were found in a registry or an index.
Abstract
X-ray computer tomography (CT) is fast becoming an accepted tool within the materials science community for the acquisition of 3D images. Here the authors review the current state of the art as CT transforms from a qualitative diagnostic tool to a quantitative one. Our review considers first the image acquisition process, including the use of iterative reconstruction strategies suited to specific segmentation tasks and emerging methods that provide more insight (e.g. fast and high resolution imaging, crystallite (grain) imaging) than conventional attenuation based tomography. Methods and shortcomings of CT are examined for the quantification of 3D volumetric data to extract key topological parameters such as phase fractions, phase contiguity, and damage levels as well as density variations. As a non-destructive technique, CT is an ideal means of following structural development over time via time lapse sequences of 3D images (sometimes called 3D movies or 4D imaging). This includes information needed to optimise manufacturing processes, for example sintering or solidification, or to highlight the proclivity of specific degradation processes under service conditions, such as intergranular corrosion or fatigue crack growth. Besides the repeated application of static 3D image quantification to track such changes, digital volume correlation (DVC) and particle tracking (PT) methods are enabling the mapping of deformation in 3D over time. Finally the use of CT images is considered as the starting point for numerical modelling based on realistic microstructures, for example to predict flow through porous materials, the crystalline deformation of polycrystalline aggregates or the mechanical properties of composite materials.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Feldkamp, L. A., Davis, L. C., & Kress, J. W. (1984) · Journal of the Optical Society of America A · doi:10.1364/josaa.1.000612 · Cited by 6,319
The quickhull algorithm for convex hulls
Barber, C. B., Dobkin, D. P., & Huhdanpaa, H. (1996) · ACM Transactions on Mathematical Software · doi:10.1145/235815.235821 · Cited by 5,359
How Long Is the Coast of Britain? Statistical Self-Similarity and Fractional Dimension
Mandelbrot, B. (1967) · Science · doi:10.1126/science.156.3775.636 · Cited by 4,090
Fatigue crack closure under cyclic tension
Elber, W. (1970) · Engineering Fracture Mechanics · doi:10.1016/0013-7944(70)90028-7 · Cited by 2,204
Simultaneous phase and amplitude extraction from a single defocused image of a homogeneous object
Paganin, D., Mayo, S. C., Gureyev, T. E., Miller, P. R., & Wilkins, S. W. (2002) · Journal of Microscopy · doi:10.1046/j.1365-2818.2002.01010.x · Cited by 2,062
Miao, J., Charalambous, P., Kirz, J., & Sayre, D. (1999) · Nature · doi:10.1038/22498 · Cited by 1,976
Phase retrieval and differential phase-contrast imaging with low-brilliance X-ray sources
Pfeiffer, F., Weitkamp, T., Bunk, O., & David, C. (2006) · Nature Physics · doi:10.1038/nphys265 · Cited by 1,855
Phase-contrast imaging using polychromatic hard X-rays
Wilkins, S. W., Gureyev, T. E., Gao, D., Pogany, A., & Stevenson, A. W. (1996) · Nature · doi:10.1038/384335a0 · Cited by 1,766
X-ray phase imaging with a grating interferometer
Weitkamp, T., Diaz, A., David, C., Pfeiffer, F., Stampanoni, M., Cloetens, P., & Ziegler, E. (2005) · Optics Express · doi:10.1364/opex.13.006296 · Cited by 1,211
Hild, F., & Roux, S. (2006) · Strain · doi:10.1111/j.1475-1305.2006.00258.x · Cited by 1,188
Chen, G.-H., Tang, J., & Leng, S. (2008) · Medical Physics · doi:10.1118/1.2836423 · Cited by 1,141
Diffraction enhanced x-ray imaging
Chapman, D., Thomlinson, W., Johnston, R. E., Washburn, D., Pisano, E., Gmür, N., Zhong, Z., Menk, R., Arfelli, F., & Sayers, D. (1997) · Physics in Medicine and Biology · doi:10.1088/0031-9155/42/11/001 · Cited by 1,098
Accurate image reconstruction from few-views and limited-angle data in divergent-beam CT
Sidky, E. Y., Kao, C.-M., & Pan, X. (2006) · Journal of X-Ray Science and Technology: Clinical Applications of Diagnosis and Therapeutics · doi:10.3233/xst-2006-00155 · Cited by 1,091
The direct examination of three-dimensional bone architecture in vitro by computed tomography
Feldkamp, L. A., Goldstein, S. A., Parfitt, M. A., Jesion, G., & Kleerekoper, M. (1989) · Journal of Bone and Mineral Research · doi:10.1002/jbmr.5650040103 · Cited by 1,071
Phase-contrast imaging of weakly absorbing materials using hard X-rays
Davis, T. J., Gao, D., Gureyev, T. E., Stevenson, A. W., & Wilkins, S. W. (1995) · Nature · doi:10.1038/373595a0 · Cited by 1,010
Digital volume correlation: Three-dimensional strain mapping using X-ray tomography
Bay, B. K., Smith, T. S., Fyhrie, D. P., & Saad, M. (1999) · Experimental Mechanics · doi:10.1007/bf02323555 · Cited by 941
Phase objects in synchrotron radiation hard x-ray imaging
Cloetens, P., Barrett, R., Baruchel, J., Guigay, J.-P., & Schlenker, M. (1996) · Journal of Physics D: Applied Physics · doi:10.1088/0022-3727/29/1/023 · Cited by 853
Soft X-ray microscopy at a spatial resolution better than 15 nm
Chao, W., Harteneck, B. D., Liddle, J. A., Anderson, E. H., & Attwood, D. T. (2005) · Nature · doi:10.1038/nature03719 · Cited by 851
Iterative Reconstruction Technique for Reducing Body Radiation Dose at CT: Feasibility Study
Hara, A. K., Paden, R. G., Silva, A. C., Kujak, J. L., Lawder, H. J., & Pavlicek, W. (2009) · American Journal of Roentgenology · doi:10.2214/ajr.09.2397 · Cited by 779
Beam hardening in X-ray reconstructive tomography
Brooks, R. A., & Chiro, G. D. (1976) · Physics in Medicine and Biology · doi:10.1088/0031-9155/21/3/004 · Cited by 721
X-ray micro-tomography an attractive characterisation technique in materials science
Salvo, L., Cloetens, P., Maire, É., Zabler, S., Blandin, J. J., Buffière, J., Ludwig, W., Boller, E., Bellet, D., & Josserond, C. (2003) · Nuclear Instruments and Methods in Physics Research Section B Beam Interactions with Materials and Atoms · doi:10.1016/s0168-583x(02)01689-0 · Cited by 586
HALL, S. A., BORNERT, M., DESRUES, J., PANNIER, Y., LENOIR, N., VIGGIANI, G., & BéSUELLE, P. (2010) · Géotechnique · doi:10.1680/geot.2010.60.5.315 · Cited by 568
The true toughness of human cortical bone measured with realistically short cracks
Koester, K. J., Ager, J. W., & Ritchie, R. O. (2008) · Nature Materials · doi:10.1038/nmat2221 · Cited by 558
Observation of microstructure and damage in materials by phase sensitive radiography and tomography
Cloetens, P., Pateyron-Salomé, M., Buffière, J. Y., Peix, G., Baruchel, J., Peyrin, F., & Schlenker, M. (1997) · Journal of Applied Physics · doi:10.1063/1.364374 · Cited by 538
Elastic Properties of Model Porous Ceramics
Roberts, A. P., & Garboczi, E. J. (2000) · Journal of the American Ceramic Society · doi:10.1111/j.1151-2916.2000.tb01680.x · Cited by 527
Recent advances in X-ray microtomography applied to materials
Stock, S. R. (2008) · International Materials Reviews · doi:10.1179/174328008x277803 · Cited by 517
In Situ Experiments with X ray Tomography: an Attractive Tool for Experimental Mechanics
Buffiere, J. Y., Maire, E., Adrien, J., Masse, J. P., & Boller, E. (2010) · Experimental Mechanics · doi:10.1007/s11340-010-9333-7 · Cited by 500
Self-citationVan Bael, S., Kerckhofs, G., Moesen, M., Pyka, G., Schrooten, J., & Kruth, J. P. (2011) · Materials Science and Engineering: A · doi:10.1016/j.msea.2011.06.045 · Cited by 452
In vivo corrosion and corrosion protection of magnesium alloy LAE442☆
Witte, F., Fischer, J., Nellesen, J., Vogt, C., Vogt, J., Donath, T., & Beckmann, F. (2010) · Acta Biomaterialia · doi:10.1016/j.actbio.2009.10.012 · Cited by 438
Age-related changes in the plasticity and toughness of human cortical bone at multiple length scales
Zimmermann, E. A., Schaible, E., Bale, H., Barth, H. D., Tang, S. Y., Reichert, P., Busse, B., Alliston, T., Ager, J. W., & Ritchie, R. O. (2011) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1107966108 · Cited by 412
Freeze casting of porous materials: review of critical factors in microstructure evolution
Li, W. L., Lu, K., & Walz, J. Y. (2012) · International Materials Reviews · doi:10.1179/1743280411y.0000000011 · Cited by 372 · cited 1×
“This can provide valuable information from a materials design viewpoint because of the scope for microstructural tailoring via control of the solidification conditions.(58) In this frame rate regime most of the work to date has been undertaken at synchrotron sources because of the greater flux.”
BackgroundX-ray microtomography of materials
Stock, S. R. (1999) · International Materials Reviews · doi:10.1179/095066099101528261 · Cited by 366
Soft X‐ray spectroscopy from image sequences with sub‐100 nm spatial resolution
Jacobsen, Wirick, Flynn, & Zimba (2000) · Journal of Microscopy · doi:10.1046/j.1365-2818.2000.00640.x · Cited by 346
Characterization of internal damage in a MMCp using X-ray synchrotron phase contrast microtomography
Buffière, J., Maire, É., Cloetens, P., Lormand, G., & Fougères, R. (1999) · Acta Materialia · doi:10.1016/s1359-6454(99)00024-5 · Cited by 338
MicroComputed Tomography: Methodology and Applications
Stock, S. R. (2008) · Thammasat University Digital Collections · Cited by 336
Evaluation of a microcomputed tomography system to study trabecular bone structure
Kuhn, J. L., Goldstein, S. A., Feldkamp, L. A., Goulet, R. W., & Jesion, G. (1990) · Journal of Orthopaedic Research · doi:10.1002/jor.1100080608 · Cited by 336
Ma, Z., Tavares, J. M. R. S., Jorge, R. N., & Mascarenhas, T. (2010) · Computer Methods in Biomechanics and Biomedical Engineering · doi:10.1080/10255840903131878 · Cited by 316
DART: A Practical Reconstruction Algorithm for Discrete Tomography
Batenburg, K. J., & Sijbers, J. (2011) · IEEE Transactions on Image Processing · doi:10.1109/tip.2011.2131661 · Cited by 315
Methods and applications of digital volume correlation
Bay, B. K. (2008) · The Journal of Strain Analysis for Engineering Design · doi:10.1243/03093247jsa436 · Cited by 285
Roux, S., Réthoré, J., & Hild, F. (2009) · Journal of Physics D: Applied Physics · doi:10.1088/0022-3727/42/21/214004 · Cited by 273
Elliott, J. C., & Dover, S. D. (1982) · Journal of Microscopy · doi:10.1111/j.1365-2818.1982.tb00376.x · Cited by 272
Watching the Growth of Bulk Grains During Recrystallization of Deformed Metals
Schmidt, S., Nielsen, S. F., Gundlach, C., Margulies, L., Huang, X., & Jensen, D. J. (2004) · Science · doi:10.1126/science.1098627 · Cited by 260
Ohnesorge, B., Flohr, T., Schwarz, K., Heiken, J. P., & Bae, K. T. (2000) · Medical Physics · doi:10.1118/1.598855 · Cited by 248
Real space soft x-ray imaging at 10 nm spatial resolution
Chao, W., Fischer, P., Tyliszczak, T., Rekawa, S., Anderson, E., & Naulleau, P. (2012) · Optics Express · doi:10.1364/oe.20.009777 · Cited by 246
Diffraction-limited imaging in a scanning transmission x-ray microscope
Jacobsen, C., Williams, S., Anderson, E., Browne, M. T., Buckley, C. J., Kern, D., Kirz, J., Rivers, M., & Zhang, X. (1991) · Optics Communications · doi:10.1016/0030-4018(91)90016-7 · Cited by 244
Sintering and microstructure of ice: a review
Blackford, J. R. (2007) · Journal of Physics D: Applied Physics · doi:10.1088/0022-3727/40/21/r02 · Cited by 230
Kruzic, J. J., Nalla, R. K., Kinney, J. H., & Ritchie, R. O. (2003) · Biomaterials · doi:10.1016/s0142-9612(03)00458-7 · Cited by 219
Nanoscale zoom tomography with hard x rays using Kirkpatrick-Baez optics
Mokso, R., Cloetens, P., Maire, E., Ludwig, W., & Buffière, J.-Y. (2007) · Applied Physics Letters · doi:10.1063/1.2719653 · Cited by 213
Self-citationIn-Line Phase-Contrast X-ray Imaging and Tomography for Materials Science
Mayo, S. C., Stevenson, A. W., & Wilkins, S. W. (2012) · Materials · doi:10.3390/ma5050937 · Cited by 210
Tkachuk, A., Duewer, F., Cui, H., Feser, M., Wang, S., & Yun, W. (2007) · Zeitschrift für Kristallographie - Crystalline Materials · doi:10.1524/zkri.2007.222.11.650 · Cited by 207
Representation of real particles for DEM simulation using X-ray tomography
Wang, L., Park, J.-Y., & Fu, Y. (2007) · Construction and Building Materials · doi:10.1016/j.conbuildmat.2005.08.013 · Cited by 204
High-energy diffraction microscopy at the advanced photon source
Lienert, U., Li, S. F., Hefferan, C. M., Lind, J., Suter, R. M., Bernier, J. V., Barton, N. R., Brandes, M. C., Mills, M. J., Miller, M. P., et al. (2011) · JOM · doi:10.1007/s11837-011-0116-0 · Cited by 191
Ludwig, W., Buffière, J.-Y., Savelli, S., & Cloetens, P. (2003) · Acta Materialia · doi:10.1016/s1359-6454(02)00320-8 · Cited by 190
Epting, W. K., Gelb, J., & Litster, S. (2012) · Advanced Functional Materials · doi:10.1002/adfm.201101525 · Cited by 188
A hard X-ray nanoprobe beamline for nanoscale microscopy
Winarski, R. P., Holt, M. V., Rose, V., Fuesz, P., Carbaugh, D., Benson, C., Shu, D., Kline, D., Stephenson, G. B., McNulty, I., et al. (2012) · Journal of Synchrotron Radiation · doi:10.1107/s0909049512036783 · Cited by 188
Characterization of multi-scale microstructural features in Opalinus Clay
Keller, L. M., Schuetz, P., Erni, R., Rossell, M. D., Lucas, F., Gasser, P., & Holzer, L. (2013) · Microporous and Mesoporous Materials · doi:10.1016/j.micromeso.2012.11.029 · Cited by 185
Meganck, J. A., Kozloff, K. M., Thornton, M. M., Broski, S. M., & Goldstein, S. A. (2009) · Bone · doi:10.1016/j.bone.2009.07.078 · Cited by 185
Three dimensional experimental and numerical multiscale analysis of a fatigue crack
Rannou, J., Limodin, N., Réthoré, J., Gravouil, A., Ludwig, W., Baïetto-Dubourg, M.-C., Buffière, J.-Y., Combescure, A., Hild, F., & Roux, S. (2010) · Computer Methods in Applied Mechanics and Engineering · doi:10.1016/j.cma.2009.09.013 · Cited by 175
Digital volume correlation including rotational degrees of freedom during minimization
Smith, T. S., Bay, B. K., & Rashid, M. M. (2002) · Experimental Mechanics · doi:10.1007/bf02410982 · Cited by 172
Fast microtomography using high energy synchrotron radiation
Di Michiel, M., Merino, J. M., Fernandez-Carreiras, D., Buslaps, T., Honkimäki, V., Falus, P., Martins, T., & Svensson, O. (2005) · Review of Scientific Instruments · doi:10.1063/1.1884194 · Cited by 169
Burnett, T. L., McDonald, S. A., Gholinia, A., Geurts, R., Janus, M., Slater, T. J. A., Haigh, S. J., Örnek, C., Al-Muaili, F., Engelberg, D., et al. (2014) · Scientific Reports · doi:10.1038/srep04711 · Cited by 164
Self-citationSanchez, S., Ahlberg, P. E., Trinajstic, K. M., Mirone, A., & Tafforeau, P. (2012) · Microscopy and Microanalysis · doi:10.1017/s1431927612001079 · Cited by 163
Asghar, Z., Requena, G., & Boller, E. (2011) · Acta Materialia · doi:10.1016/j.actamat.2011.07.006 · Cited by 162
Voxel-Scale Digital Volume Correlation
Leclerc, H., Périé, J.-N., Roux, S., & Hild, F. (2011) · Experimental Mechanics · doi:10.1007/s11340-010-9407-6 · Cited by 161
Role of microstructure in the aging-related deterioration of the toughness of human cortical bone
Nalla, R. K., Kruzic, J. J., Kinney, J. H., Balooch, M., Ager, J. W., & Ritchie, R. O. (2006) · Materials Science and Engineering: C · doi:10.1016/j.msec.2005.08.021 · Cited by 160
Moreno-Atanasio, R., Williams, R. A., & Jia, X. (2010) · Particuology · doi:10.1016/j.partic.2010.01.001 · Cited by 159
Three-Dimensional Analysis of High-Resolution X-Ray Computed Tomography Data with Morpho+
Brabant, L., Vlassenbroeck, J., De Witte, Y., Cnudde, V., Boone, M. N., Dewanckele, J., & Van Hoorebeke, L. (2011) · Microscopy and Microanalysis · doi:10.1017/s1431927610094389 · Cited by 159
Recent Advances in CT Image Reconstruction
Hsieh, J., Nett, B. E., Zhou, Y., Sauer, K. D., Thibault, J., & Bouman, C. A. (2013) · Current Radiology Reports · doi:10.1007/s40134-012-0003-7 · Cited by 153
Analytical and numerical prediction of heat transfer and pressure drop in open-cell metal foams
Bai, M., & Chung, J. N. (2011) · International Journal of Thermal Sciences · doi:10.1016/j.ijthermalsci.2011.01.007 · Cited by 148
Thurner, P. J., Wyss, P., Voide, R., Stauber, M., Stampanoni, M., Sennhauser, U. J., & Müller, R. (2006) · Bone · doi:10.1016/j.bone.2006.01.147 · Cited by 144
Phase Contrast X-Ray Synchrotron Imaging: Opening Access to Fossil Inclusions in Opaque Amber
Lak, M., Néraudeau, D., Nel, A., Cloetens, P., Perrichot, V., & Tafforeau, P. (2008) · Microscopy and Microanalysis · doi:10.1017/s1431927608080264 · Cited by 142
Bulk observation of metal powder sintering by X-ray synchrotron microtomography
Lame, O., Bellet, D., Michiel, M. D., & Bouvard, D. (2003) · Acta Materialia · doi:10.1016/j.actamat.2003.10.032 · Cited by 139
Shearing, P. R., Brandon, N. P., Gelb, J., Bradley, R. S., Withers, P. J., Marquis, A. J., Cooper, S. J., & Harris, S. J. (2012) · Journal of The Electrochemical Society · doi:10.1149/2.053207jes · Cited by 138
Self-citationDavis, G. R., & Elliott, J. C. (1997) · Nuclear Instruments and Methods in Physics Research Section A Accelerators Spectrometers Detectors and Associated Equipment · doi:10.1016/s0168-9002(97)00566-4 · Cited by 135
Betts, C. (2012) · Materials Science and Technology · doi:10.1179/026708311x13135950699290 · Cited by 131
Soft-tissue phase-contrast tomography with an x-ray tube source
Bech, M., Jensen, T. H., Feidenhans’l, R., Bunk, O., Dávid, C., & Pfeiffer, F. (2009) · Physics in Medicine and Biology · doi:10.1088/0031-9155/54/9/010 · Cited by 128
Ultrahigh-Resolution X-ray Tomography
Haddad, W. S., McNulty, I., Trebes, J. E., et al. (1994) · Science · doi:10.1126/science.266.5188.1213 · Cited by 125
Zernike phase contrast in scanning microscopy with X-rays
Holzner, C., Feser, M., Vogt, S., Hornberger, B., Baines, S. B., & Jacobsen, C. J. (2010) · Nature Physics · doi:10.1038/nphys1765 · Cited by 124
Diémoz, P. C., Bravin, A., & Coan, P. (2012) · Optics Express · doi:10.1364/oe.20.002789 · Cited by 122
Metallic foams: Radiative properties/comparison between different models
Loretz, M., Coquard, R., Baillis, D. D., & Maire, É. (2007) · Journal of Quantitative Spectroscopy and Radiative Transfer · doi:10.1016/j.jqsrt.2007.05.007 · Cited by 121
Wavelet-based multiresolution local tomography
Rashid-Farrokhi, F., Liu, K. J. R., Berenstein, C. A., & Walnut, D. F. (1997) · IEEE Transactions on Image Processing · doi:10.1109/83.624961 · Cited by 121
Bernard, D., Nielsen, Ø., Salvo, L., & Cloetens, P. (2004) · Materials Science and Engineering A · doi:10.1016/j.msea.2004.09.004 · Cited by 120
Eastwood, D. S., Yufit, V., Gelb, J., Gu, A., Bradley, R. S., Harris, S. J., Brett, D. J. L., Brandon, N. P., Lee, P. D., Withers, P. J., et al. (2013) · Advanced Energy Materials · doi:10.1002/aenm.201300506 · Cited by 114
Self-citationZeghondy, B., Iacona, E., & Taine, J. (2006) · International Journal of Heat and Mass Transfer · doi:10.1016/j.ijheatmasstransfer.2006.02.034 · Cited by 112
Jacques, S. D. M., Michiel, M. D., Beale, A. M., Sochi, T., O’Brien, M. G., Espinosa‐Alonso, L., Weckhuysen, B. M., & Barnes, P. W. (2011) · Angewandte Chemie International Edition · doi:10.1002/anie.201104604 · Cited by 112
Guvenilir, A., Breunig, T. M., Kinney, J. H., et al. (1997) · Acta Materialia · doi:10.1016/s1359-6454(96)00311-4 · Cited by 105
Simultaneous Tomography and Diffraction Analysis of Creep Damage
Pyzalla, A. R., Camin, B., Buslaps, T., et al. (2005) · Science · doi:10.1126/science.1106778 · Cited by 105
Quantifying the 3D macrostructure of tissue scaffolds
Jones, J. R., Atwood, R., Poologasundarampillai, G., Yue, S., & Lee, P. D. (2008) · Journal of Materials Science Materials in Medicine · doi:10.1007/s10856-008-3597-9 · Cited by 104
Veyhl, C., Belova, I. V., Murch, G. E., & Fiedler, T. (2011) · Materials Science and Engineering A · doi:10.1016/j.msea.2011.02.031 · Cited by 103
Dowker, S. E. P., Elliott, J. C., Davis, G. R., Wilson, R. M., & Cloetens, P. (2004) · Caries Research · doi:10.1159/000080580 · Cited by 103
Nielsen, S. F., Poulsen, H. F., Beckmann, F., et al. (2003) · Acta Materialia · doi:10.1016/s1359-6454(03)00053-3 · Cited by 102
Nanoscale X-Ray Microscopic Imaging of Mammalian Mineralized Tissue
Andrews, J. C., Almeida, E. A. C., van der Meulen, M. C. H., Alwood, J. S., Lee, C., Liu, Y., Chen, J., Meirer, F., Feser, M., Gelb, J., et al. (2010) · Microscopy and Microanalysis · doi:10.1017/s1431927610000231 · Cited by 101
Yin, G.-C., Tang, M., Song, Y., Chen, F., Liang, K. S., Duewer, F., Yun, W., Ko, C.-H., & Shieh, H. D. (2006) · Applied Physics Letters · doi:10.1063/1.2211300 · Cited by 101
Buffière, J., Ferrié, E., Proudhon, H., et al. (2006) · Materials Science and Technology · doi:10.1179/174328406x114135 · Cited by 100
Coleri, E., Harvey, J., Yang, K., & Boone, J. M. (2012) · Construction and Building Materials · doi:10.1016/j.conbuildmat.2011.12.071 · Cited by 100
Metamorphosis revealed: time-lapse three-dimensional imaging inside a living chrysalis
Lowe, T., Garwood, R. J., Simonsen, T. J., Bradley, R. S., & Withers, P. J. (2013) · Journal of The Royal Society Interface · doi:10.1098/rsif.2013.0304 · Cited by 100
Self-citationDillard, T., N’Guyen, F., Maire, É., Salvo, L., Forest, S., Bienvenu, Y., Bartout, J. D., Croset, M., Dendievel, R., & Cloetens, P. (2005) · The Philosophical Magazine A Journal of Theoretical Experimental and Applied Physics · doi:10.1080/14786430412331331916 · Cited by 99
The history and future of X-ray microscopy
Kirz, J., & Jacobsen, C. J. (2009) · Journal of Physics Conference Series · doi:10.1088/1742-6596/186/1/012001 · Cited by 94
High energy X-ray scattering tomography applied to bone
Stock, S. R., Carlo, F. D., & Almer, J. (2007) · Journal of Structural Biology · doi:10.1016/j.jsb.2007.10.001 · Cited by 88
Limodin, N., Réthoré, J., Buffière, J., et al. (2010) · Acta Materialia · doi:10.1016/j.actamat.2010.01.024 · Cited by 87
Analytical Modelling of the Radiative Properties of Metallic Foams: Contribution of X‐Ray Tomography
Loretz, M., Maire, É., & Baillis, D. D. (2008) · Advanced Engineering Materials · doi:10.1002/adem.200700334 · Cited by 87
Direct observation of 3-D grain growth in Al–0.1% Mn
Schmidt, S., Olsen, U. L., Poulsen, H. F., Sørensen, H. O., Lauridsen, E. M., Margulies, L., Maurice, C., & Jensen, D. J. (2008) · Scripta Materialia · doi:10.1016/j.scriptamat.2008.04.049 · Cited by 86
Guan, Y., Li, W., Gong, Y., Liu, G., Zhang, X., Chen, J., Gelb, J., Yun, W., Xiong, Y., Tian, Y., et al. (2010) · Journal of Power Sources · doi:10.1016/j.jpowsour.2010.09.059 · Cited by 86
Stienon, A., Fazekas, A., Buffière, J.-Y., et al. (2009) · Materials Science and Engineering A · doi:10.1016/j.msea.2009.02.008 · Cited by 84
Leng, H., Wang, X., Ross, R. D., Niebur, G. L., & Roeder, R. K. (2007) · Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials · doi:10.1016/j.jmbbm.2007.06.002 · Cited by 84
Cross-linked polymers for nanofabrication of high-resolution zone plates in nickel and germanium
Schneider, G., Schliebe, T., & Aschoff, H. (1995) · Journal of Vacuum Science & Technology B Microelectronics and Nanometer Structures Processing Measurement and Phenomena · doi:10.1116/1.588271 · Cited by 83
Fracture, aging, and disease in bone
Ager, J. W., Balooch, G., & Ritchie, R. O. (2006) · Journal of materials research/Pratt's guide to venture capital sources · doi:10.1557/jmr.2006.0242 · Cited by 82
Zone-doubled Fresnel zone plates for high-resolution hard X-ray full-field transmission microscopy
Vila‐Comamala, J., Pan, Y., Lombardo, J. J., et al. (2012) · Journal of Synchrotron Radiation · doi:10.1107/s0909049512029640 · Cited by 77
20-nm-resolution Soft x-ray microscopy demonstrated by use of multilayer test structures
Chao, W. L., Anderson, E. H., Denbeaux, G. P., Harteneck, B. D., Liddle, J. A., Olynick, D. L., Pearson, A. L., Salmassi, F. H., Song, C. Y., & Attwood, D. T. (2003) · Optics Letters · doi:10.1364/ol.28.002019 · Cited by 69
Mookhoek, S. D., Mayo, S. C., Hughes, A. E., Furman, S., Fischer, H., & van der Zwaag, S. (2010) · Advanced Engineering Materials · doi:10.1002/adem.200900289 · Cited by 67
Isaac, A. C., Sket, F., Reimers, W., Camin, B., Sauthoff, G., & Pyzalla, A. R. (2007) · Materials Science and Engineering A · doi:10.1016/j.msea.2007.05.108 · Cited by 65
Characterization of hierarchical pore structures in ceramics using multiscale tomography
Tariq, F., Haswell, R., Lee, P. D., et al. (2011) · Acta Materialia · doi:10.1016/j.actamat.2010.12.012 · Cited by 64
The effect of thermal oxidation on polycrystalline graphite studied by X-ray tomography
Babout, L., Mummery, P., Marrow, T. J., et al. (2004) · Carbon · doi:10.1016/j.carbon.2004.11.002 · Cited by 61
Grain-resolved elastic strains in deformed copper measured by three-dimensional X-ray diffraction
Oddershede, J., Schmidt, S., Poulsen, H. F., Margulies, L., Wright, J. P., Moscicki, M., Reimers, W., & Winther, G. (2011) · Materials Characterization · doi:10.1016/j.matchar.2011.04.020 · Cited by 61
Guan, Y., Gong, Y., Li, W., Gelb, J., Zhang, L., Liu, G., Zhang, X., Song, X., Xia, C., Xiong, Y., et al. (2011) · Journal of Power Sources · doi:10.1016/j.jpowsour.2011.08.083 · Cited by 59
Quantitative 3D Characterization of Solidification Structure and Defect Evolution in Al Alloys
Puncreobutr, C., Lee, P. D., Hamilton, R., & Phillion, A. B. (2012) · JOM · doi:10.1007/s11837-011-0217-9 · Cited by 58
Manning, P. L., Margetts, L., Johnson, M. R., Withers, P. J., Sellers, W. I., Falkingham, P. L., Mummery, P. M., Barrett, P. M., & Raymont, D. R. (2009) · The Anatomical Record · doi:10.1002/ar.20986 · Cited by 57
Self-citationIn situ tomographic investigation on the early hydration behaviors of cementing systems
Gastaldi, D., Canonico, F., Capelli, L., Boccaleri, E., Milanesio, M., Palin, L., Croce, G., Marone, F., Mader, K. S., & Stampanoni, M. (2011) · Construction and Building Materials · doi:10.1016/j.conbuildmat.2011.10.016 · Cited by 55
In SituX-Ray Tomography Studies of Microstructural Evolution Combined with 3D Modeling
Buffière, J., Cloetens, P., Ludwig, W., et al. (2008) · MRS Bulletin · doi:10.1557/mrs2008.126 · Cited by 54
Hierarchically structured titanium foams for tissue scaffold applications
Singh, R., Lee, P. D., Jones, J. R., Poologasundarampillai, G., Post, T., Lindley, T. C., & Dashwood, R. J. (2010) · Acta Biomaterialia · doi:10.1016/j.actbio.2010.06.027 · Cited by 51
Microimaging and tomography with chemical speciation
Rau, C., Somogyi, A., & Simionovici, A. (2003) · Nuclear Instruments and Methods in Physics Research Section B Beam Interactions with Materials and Atoms · doi:10.1016/s0168-583x(02)01737-8 · Cited by 51
High-resolution lenses for sub-100 nm x-ray fluorescence microscopy
Dávid, C., Kaulich, B., Barrett, R., Salome-Pateyron, M., & Susini, J. (2000) · Applied Physics Letters · doi:10.1063/1.1329638 · Cited by 51
Fiber bundle push-out test and image-based finite element simulation for 3D carbon/carbon composites
Sharma, R., Mahajan, P., & Mittal, R. K. (2012) · Carbon · doi:10.1016/j.carbon.2012.02.030 · Cited by 48
A laboratory system for element specific hyperspectral X-ray imaging
Jacques, S. D. M., Egan, C., Wilson, M. D., Veale, M. C., Seller, P., & Cernik, R. J. (2013) · The Analyst · doi:10.1039/c2an36157d · Cited by 46
Syha, M., Rheinheimer, W., Bäurer, M., et al. (2011) · Scripta Materialia · doi:10.1016/j.scriptamat.2011.08.005 · Cited by 46
HIGH RESOLUTION COMPUTED TOMOGRAPHY AND IMPLICATIONS FOR FATIGUE CRACK CLOSURE MODELLING
Guvenilir, & Stock, S. R. (1998) · Fatigue & Fracture of Engineering Materials & Structures · doi:10.1046/j.1460-2695.1998.00062.x · Cited by 46
Development of fast (sub-minute) micro-tomography
Uesugi, K., Hoshino, M., Takeuchi, A., et al. (2010) · AIP conference proceedings · doi:10.1063/1.3478197 · Cited by 43
Tsafnat, N., Amanat, N., & Jones, A. S. (2010) · Fuel · doi:10.1016/j.fuel.2010.08.026 · Cited by 40
Fuloria, D., & Lee, P. D. (2009) · Acta Materialia · doi:10.1016/j.actamat.2009.07.051 · Cited by 40
A prioriinformation in a regularized sinogram-based method for removing ring artefacts in tomography
Titarenko, S. S., Titarenko, V., Kyrieleis, A., & Withers, P. J. (2010) · Journal of Synchrotron Radiation · doi:10.1107/s0909049510010964 · Cited by 40
Self-citationBabout, L., Marsden, B. J., Mummery, P., et al. (2008) · Acta Materialia · doi:10.1016/j.actamat.2008.04.045 · Cited by 37
Wismans, J. G. F., Govaert, L. E., & van Dommelen, J. A. W. (2010) · Journal of Polymer Science Part B Polymer Physics · doi:10.1002/polb.22055 · Cited by 36
Morphological analysis of pores in directionally freeze-cast titanium foams
Fife, J. L., Li, J. C., Dunand, D. C., & Voorhees, P. W. (2009) · Journal of materials research/Pratt's guide to venture capital sources · doi:10.1557/jmr.2009.0023 · Cited by 28
Rosenberg, E., Brusselle-Dupend, N., & Epsztein, T. (2011) · Materials Science and Engineering A · doi:10.1016/j.msea.2011.04.091 · Cited by 25
Revealing the three dimensional internal structure of aluminium alloys
Thompson, G. E., Hashimoto, T., Zhong, X., Curioni, M., Zhou, X., Skeldon, P., Withers, P. J., Carr, J., & Monteith, A. G. (2013) · Surface and Interface Analysis · doi:10.1002/sia.5221 · Cited by 20
Self-citation4D Damage Characterization during Superplastic Deformation of Magnesium Alloys
Lhuissier, P., Scheel, M., Salvo, L., Boller, E., Michiel, M. D., & Blandin, J. J. (2012) · Materials science forum · doi:10.4028/www.scientific.net/msf.735.61 · Cited by 6
Cited by
Failure of metals I: Brittle and ductile fracture
Pineau, A., Benzerga, A. A., & Pardoen, T. (2016) · Acta Materialia · doi:10.1016/j.actamat.2015.12.034 · Cited by 1,180
Withers, P. J., Bouman, C., Carmignato, S., Cnudde, V., Grimaldi, D., Hagen, C. K., Maire, E., Manley, M., Du Plessis, A., & Stock, S. R. (2021) · Nature Reviews Methods Primers · doi:10.1038/s43586-021-00015-4 · Cited by 1,079
Self-citationAlloy design for aircraft engines
Pollock, T. M. (2016) · Nature Materials · doi:10.1038/nmat4709 · Cited by 931
In-operando high-speed tomography of lithium-ion batteries during thermal runaway
Finegan, D. P., Scheel, M., Robinson, J. B., Tjaden, B., Hunt, I., Mason, T. J., Millichamp, J., Di Michiel, M., Offer, G. J., Hinds, G., et al. (2015) · Nature Communications · doi:10.1038/ncomms7924 · Cited by 844
In situ X-ray imaging of defect and molten pool dynamics in laser additive manufacturing
Leung, C. L. A., Marussi, S., Atwood, R. C., Towrie, M., Withers, P. J., & Lee, P. D. (2018) · Nature Communications · doi:10.1038/s41467-018-03734-7 · Cited by 817
Self-citation
Metadata
- Authors
- Maire, E., & Withers, P. J.
- Venue
- International Materials Reviews
- Publisher
- SAGE Publications
- Published
- 2014-01
- Volume
- 59
- Issue
- 1
- Pages
- 1-43
- ISSN
- 0950-6608 (ISSN-L)
- 1743-2804
- OpenAlex
- W2154940804
- Cited by
- 1,374
- References
- 136
- FWCI
- 63.57
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.