Myocardial first-pass perfusion cardiovascular magnetic resonance: history, theory, and current state of the art
Open accessThe DOI matches its Crossref record; 59 of the 59 references it cites were found in a registry or an index.
Abstract
In less than two decades, first-pass perfusion cardiovascular magnetic resonance (CMR) has undergone a wide range of changes with the development and availability of improved hardware, software, and contrast agents, in concert with a better understanding of the mechanisms of contrast enhancement. The following review provides a perspective of the historical development of first-pass CMR, the developments in pulse sequence design and contrast agents, the relevant animal models used in early preclinical studies, the mechanism of artifacts, the differences between 1.5T and 3T scanning, and the relevant clinical applications and protocols. This comprehensive overview includes a summary of the past clinical performance of first-pass perfusion CMR and current clinical applications using state-of-the-art methodologies.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
American Heart Association Writing Group on Myocardial Segmentation and Registration for Cardiac Imaging:, Cerqueira, M. D., Weissman, N. J., Dilsizian, V., Jacobs, A. K., Kaul, S., Laskey, W. K., Pennell, D. J., Rumberger, J. A., Ryan, T., et al. (2002) · Circulation · doi:10.1161/hc0402.102975 · Cited by 6,990
SENSE: Sensitivity encoding for fast MRI
Pruessmann, K. P., Weiger, M., Scheidegger, M. B., & Boesiger, P. (1999) · Magnetic Resonance in Medicine · doi:10.1002/(sici)1522-2594(199911)42:5<952::aid-mrm16>3.0.co;2-s · Cited by 6,251 · cited 1×
“Parallel imaging [25-27] is also widely used as a means for accelerating image acquisition.”
Generalized autocalibrating partially parallel acquisitions (GRAPPA)
Griswold, M. A., Jakob, P. M., Heidemann, R. M., Nittka, M., Jellus, V., Wang, J., Kiefer, B., & Haase, A. (2002) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10171 · Cited by 5,303 · cited 1×
“Parallel imaging [25-27] is also widely used as a means for accelerating image acquisition.”
Kim, R. J., Wu, E., Rafael, A., Chen, E.-L., Parker, M. A., Simonetti, O., Klocke, F. J., Bonow, R. O., & Judd, R. M. (2000) · New England Journal of Medicine · doi:10.1056/nejm200011163432003 · Cited by 3,306 · cited 2×
“Viable myocardium based on transmural extent of scar along with extent of ischemia may help guide assessment of the need for and likely response to revascularization in such cases [56].”
Simultaneous acquisition of spatial harmonics (SMASH): Fast imaging with radiofrequency coil arrays
Sodickson, D. K., & Manning, W. J. (1997) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910380414 · Cited by 2,142 · cited 1×
“Parallel imaging [25-27] is also widely used as a means for accelerating image acquisition.”
Wagner, A., Mahrholdt, H., Holly, T. A., Elliott, M. D., Regenfus, M., Parker, M., Klocke, F. J., Bonow, R. O., Kim, R. J., & Judd, R. M. (2003) · The Lancet · doi:10.1016/s0140-6736(03)12389-6 · Cited by 1,307 · cited 4×
“Two studies [7,80] compared flow reserve by CMR versus PET, the non-invasive gold-standard at present, and demonstrated a high correlation and diagnostic accuracy.”
InfluentialACC/AHA/ASNC Guidelines for the Clinical Use of Cardiac Radionuclide Imaging—Executive Summary
Klocke, F. J., Baird, M. G., Lorell, B. H., Bateman, T. M., Messer, J. V., Berman, D. S., O’Gara, P. T., Carabello, B. A., Russell, R. O., Cerqueira, M. D., et al. (2003) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2003.08.011 · Cited by 1,303
Characteristics of gadolinium-DTPA complex: a potential NMR contrast agent
Weinmann, H., Brasch, R., Press, W., & Wesbey, G. (1984) · American Journal of Roentgenology · doi:10.2214/ajr.142.3.619 · Cited by 1,231 · cited 1×
“Due to its seven unpaired electrons, gadolinium is one of the most effective paramagnetic agents[9].”
Hachamovitch, R., Berman, D. S., Shaw, L. J., Kiat, H., Cohen, I., Cabico, J. A., Friedman, J., & Diamond, G. A. (1998) · Circulation · doi:10.1161/01.cir.97.6.535 · Cited by 1,221 · cited 1×
“Single photon emission computed tomographic (SPECT) imaging of myocardial perfusion with 201TI or 99mTc-labeled agents is an established clinical standard [1-4], but has relatively poor spatial resolution, suffers from soft tissue attenuation artifacts, is not quantitative, and delivers a significant dose of ionizing…”
McCrohon, J. A., Moon, J. C. C., Prasad, S. K., McKenna, W. J., Lorenz, C. H., Coats, A. J. S., & Pennell, D. J. (2003) · Circulation · doi:10.1161/01.cir.0000078641.19365.4c · Cited by 1,154 · cited 1×
“The value added by LGE imaging comes from its proven reliability in delineating extent of infarcted myocardium[56] as well as its superior ability to detect myocardial disease due to other nonischemic cardiomyopathies [88].”
Panting, J. R., Gatehouse, P. D., Yang, G.-Z., Grothues, F., Firmin, D. N., Collins, P., & Pennell, D. J. (2002) · New England Journal of Medicine · doi:10.1056/nejmoa012369 · Cited by 767
Magnetic Resonance Perfusion Measurements for the Noninvasive Detection of Coronary Artery Disease
Nagel, E. C., Klein, C., Paetsch, I., Hettwer, S., Schnackenburg, B., Wegscheider, K., & Fleck, E. (2003) · Circulation · doi:10.1161/01.cir.0000080915.35024.a9 · Cited by 683 · cited 1×
“[90] upslope 84 51% 88% 90% 89%”
Schwitter, J., Nanz, D., Kneifel, S., Bertschinger, K., Büchi, M., Knüsel, P. R., Marincek, B., Lüscher, T. F., & von Schulthess, G. K. (2001) · Circulation · doi:10.1161/01.cir.103.18.2230 · Cited by 663 · cited 5×
“While the earliest CMR studies had limitations, such as poor slice coverage and low temporal resolution, recent clinical studies show that CMR now compares quite favorably to SPECT and PET [6-8].”
InfluentialCommittee Members, Klocke, F. J., Baird, M. G., Lorell, B. H., Bateman, T. M., Messer, J. V., Berman, D. S., O’Gara, P. T., Carabello, B. A., Russell, R. O., et al. (2003) · Circulation · doi:10.1161/01.cir.0000080946.42225.4d · Cited by 659
Cerebral blood flow determination by rapid-sequence computed tomography: theoretical analysis.
Axel, L. (1980) · Radiology · doi:10.1148/radiology.137.3.7003648 · Cited by 625 · cited 1×
“A potentially better approach is to approximately mathematically undo ("deconvolve") the effects of the AIF from the observed tissue response, in order to estimate the corresponding underlying MTT and calculate the blood flow; a variety of approaches have been proposed for carrying out such calculations [29,62,63].”
Self-citationAl-Saadi, N., Nagel, E., Gross, M., Bornstedt, A., Schnackenburg, B., Klein, C., Klimek, W., Oswald, H., & Fleck, E. (2000) · Circulation · doi:10.1161/01.cir.101.12.1379 · Cited by 578 · cited 2×
“However, in research endeavors and in some clinical settings, one may use a relative index of myocardial perfusion reserve [7,57,64,65].”
EANM/ESC procedural guidelines for myocardial perfusion imaging in nuclear cardiology
Hesse, B., Tägil, K., Cuocolo, A., Anagnostopoulos, C., Bardiés, M., Bax, J., Bengel, F., Busemann Sokole, E., Davies, G., Dondi, M., et al. (2005) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-005-1779-y · Cited by 527 · cited 1×
“Single photon emission computed tomographic (SPECT) imaging of myocardial perfusion with 201TI or 99mTc-labeled agents is an established clinical standard [1-4], but has relatively poor spatial resolution, suffers from soft tissue attenuation artifacts, is not quantitative, and delivers a significant dose of ionizing…”
MAXWELL, M. P., HEARSE, D. J., & YELLON, D. M. (1987) · Cardiovascular Research · doi:10.1093/cvr/21.10.737 · Cited by 515 · cited 1×
“demonstrated that dogs and cats possess the greatest coronary collateral flow after acute ischemia, with pigs possessing the least, and rats, rabbits, and sheep intermediate between dogs and pigs[15].”
Hombach, V., Grebe, O., Merkle, N., Waldenmaier, S., Höher, M., Kochs, M., Wöhrle, J., & Kestler, H. A. (2005) · European Heart Journal · doi:10.1093/eurheartj/ehi147 · Cited by 496 · cited 1×
“Patients who had infarcts with microvascular obstruction were found to have significantly more events, such as death and hospitalization for heart failure, and increased adverse remodeling [73-75].”
Lima, J. A. C., Judd, R. M., Bazille, A., Schulman, S. P., Atalar, E., & Zerhouni, E. A. (1995) · Circulation · doi:10.1161/01.cir.92.5.1117 · Cited by 474
Jerosch‐Herold, M., Wilke, N. M., Stillman, A. E., & Wilson, R. F. (1998) · Medical Physics · doi:10.1118/1.598163 · Cited by 474 · cited 2×
“A potentially better approach is to approximately mathematically undo ("deconvolve") the effects of the AIF from the observed tissue response, in order to estimate the corresponding underlying MTT and calculate the blood flow; a variety of approaches have been proposed for carrying out such calculations [29,62,63].”
Clinical magnetic resonance imaging
Edelman, R. R., Hesselink, J. R., & Zlatkin, M. B. (1990) · Saunders eBooks · Cited by 420
Klem, I., Heitner, J. F., Shah, D. J., Sketch, M. H., Behar, V., Weinsaft, J., Cawley, P., Parker, M., Elliott, M., Judd, R. M., et al. (2006) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2005.10.074 · Cited by 415 · cited 3×
“A step-wise algorithm that begins with review of LGE images, followed by stress and rest perfusion images works well for overall classification of presence or absence of epicardial coronary disease in most cases [46].”
InfluentialFirst-pass cardiac perfusion: evaluation with ultrafast MR imaging.
Atkinson, D. J., Burstein, D., & Edelman, R. R. (1990) · Radiology · doi:10.1148/radiology.174.3.2305058 · Cited by 359 · cited 2×
“Thus, perfused tissue appears brighter during the first pass of the gadolinium-based contrast agent[5].”
Paetsch, I., Jahnke, C., Wahl, A., Gebker, R., Neuss, M., Fleck, E., & Nagel, E. (2004) · Circulation · doi:10.1161/01.cir.0000138927.00357.fb · Cited by 333 · cited 1×
“Paetch et al.[83] reported similarly high sensitivity, specificity, and accuracy compared to dobutamine stress MR for detection of coronary artery disease.”
Wu, K. C., Kim, R. J., Bluemke, D. A., Rochitte, C. E., Zerhouni, E. A., Becker, L. C., & Lima, J. A. C. (1998) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(98)00429-x · Cited by 321 · cited 2×
“More importantly the presence of microvascular obstruction has been shown to have negative prognostic value in patients with acute infarcts [67,73,74].”
Ingkanisorn, W. P., Kwong, R. Y., Bohme, N. S., Geller, N. L., Rhoads, K. L., Dyke, C. K., Paterson, D. I., Syed, M. A., Aletras, A. H., & Arai, A. E. (2006) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2005.11.059 · Cited by 320 · cited 2×
“In a study of 135 patients, who presented to the emergency department with chest pain, but without acute myocardial infarction, Ingkanisorn et al.[84] reported that an abnormal adenosine perfusion CMR exam had a 100% sensitivity and 93% specificity for predicting future events, such as coronary artery disease, new MI,…”
Microvascular Obstruction and Left Ventricular Remodeling Early After Acute Myocardial Infarction
Gerber, B. L., Rochitte, C. E., Melin, J. A., McVeigh, E. R., Bluemke, D. A., Wu, K. C., Becker, L. C., & Lima, J. A. C. (2000) · Circulation · doi:10.1161/01.cir.101.23.2734 · Cited by 288 · cited 2×
“More importantly the presence of microvascular obstruction has been shown to have negative prognostic value in patients with acute infarcts [67,73,74].”
Self-citationAbsolute Myocardial Perfusion in Canines Measured by Using Dual-Bolus First-Pass MR Imaging
Christian, T. F., Rettmann, D. W., Aletras, A. H., Liao, S. L., Taylor, J. L., Balaban, R. S., & Arai, A. E. (2004) · Radiology · doi:10.1148/radiol.2323030573 · Cited by 286 · cited 1×
“This has led to two imaging strategies: 1) the "dual-bolus" method[32,33], which involves AIF measurement during a separate lowdose injection (1/10th or 1/20th the dose) prior to the fulldose injection used for the measurement of myocardial enhancement and 2) the "dual-sequence" method [3436], which replaces one of th…”
Water diffusion and exchange as they influence contrast enhancement
Donahue, K. M., Weisskoff, R. M., & Burstein, D. (1997) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.1880070114 · Cited by 270 · cited 1×
“For low doses of paramagnetic agents, an approximately linear relationship between the image intensity and contrast agent concentration exists[10].”
Myocardial blood flow quantification with MRI by model‐independent deconvolution
Jerosch‐Herold, M., Swingen, C., & Seethamraju, R. T. (2002) · Medical Physics · doi:10.1118/1.1473135 · Cited by 268 · cited 1×
“For example, measurements of regional myocardial blood flow (in ml/g/min) can be made using timeintensity curve deconvolution with a measured arterial input function (AIF), usually from the left ventricular cavity or ascending aorta[29,30].”
Bernstein, M. A., Huston, J., & Ward, H. A. (2006) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.20698 · Cited by 255
Tissue Mean Transit Time from Dynamic Computed Tomography by a Simple Deconvolution Technique
AXEL, L. (1983) · Investigative Radiology · doi:10.1097/00004424-198301000-00018 · Cited by 251 · cited 1×
“A potentially better approach is to approximately mathematically undo ("deconvolve") the effects of the AIF from the observed tissue response, in order to estimate the corresponding underlying MTT and calculate the blood flow; a variety of approaches have been proposed for carrying out such calculations [29,62,63].”
Self-citationEarly Contrast-Enhanced MRI Predicts Late Functional Recovery After Reperfused Myocardial Infarction
Rogers, W. J., Kramer, C. M., Geskin, G., Hu, Y.-L., Theobald, T. M., Vido, D. A., Petruolo, S., & Reichek, N. (1999) · Circulation · doi:10.1161/01.cir.99.6.744 · Cited by 244 · cited 1×
“The presence of microvascular obstruction in an infarcted area can be a marker of non-viable tissue in which function rarely recovers [68-72].”
Giang, T. V., Nanz, D., Coulden, R. A., Friedrich, M. G., Graves, M. J., Al‐Saadi, N., Lüscher, T. F., vonSchulthess, G., & Schwitter, J. (2004) · European Heart Journal · doi:10.1016/j.ehj.2004.06.037 · Cited by 211 · cited 1×
“[78,79] Most studies have examined the diagnostic accuracy for detection of anatomical coronary artery stenosis (defined either as > 50% or > 75% luminal diameter reduction).”
Ishida, N., Sakuma, H., Motoyasu, M., Okinaka, T., Isaka, N., Nakano, T., & Takeda, K. (2003) · Radiology · doi:10.1148/radiol.2291021118 · Cited by 208 · cited 1×
“Ishida et al.[82] showed a higher diagnostic accuracy of perfusion CMR than SPECT for detection of significant CAD.”
Jayaweera, A. R., Wei, K., Coggins, M., Bin, J. P., Goodman, C., & Kaul, S. (1999) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.1999.277.6.h2363 · Cited by 186 · cited 2×
“Thus, the ischemic regions demonstrate reduced signal intensity relative to the normal myocardium on T1-weighted images during vasodilation and appear as a perfusion defect [54].”
Lanza, G. A., Buffon, A., Sestito, A., Natale, L., Sgueglia, G. A., Galiuto, L., Infusino, F., Mariani, L., Centola, A., & Crea, F. (2008) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2007.08.060 · Cited by 185
Ibrahim, T., Nekolla, S. G., Schreiber, K., Odaka, K., Volz, S., Mehilli, J., Güthlin, M., Delius, W., & Schwaiger, M. (2002) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(01)01829-0 · Cited by 178 · cited 1×
“Two studies [7,80] compared flow reserve by CMR versus PET, the non-invasive gold-standard at present, and demonstrated a high correlation and diagnostic accuracy.”
Nuclear cardiology : state of the art and future directions
Zaret, B. L., & Beller, G. (1993) · Mosby eBooks · Cited by 177
Rieber, J., Huber, A. M. A., Erhard, I., Mueller, S., Schweyer, M., Köenig, A., Schiele, T. M., Theisen, K., Siebert, U., Schoenberg, S. O., et al. (2006) · European Heart Journal · doi:10.1093/eurheartj/ehl039 · Cited by 176 · cited 1×
“In another study, Rieber et al.[81] compared the diagnostic accuracy of perfusion CMR versus angiographically measured fractional flow reserve and reported good diagnostic accuracy of perfusion CMR to this invasive gold-standard.”
Taylor, A. J., Al-Saadi, N., Abdel-Aty, H., Schulz-Menger, J., Messroghli, D. R., & Friedrich, M. G. (2004) · Circulation · doi:10.1161/01.cir.0000127812.62277.50 · Cited by 169 · cited 1×
“The presence of microvascular obstruction in an infarcted area can be a marker of non-viable tissue in which function rarely recovers [68-72].”
Human cardiac imaging at 3 T using phased array coils
Noeske, R., Seifert, F. C., Rhein, K. H., & Rinneberg, H. H. (2000) · Magnetic Resonance in Medicine · doi:10.1002/1522-2594(200012)44:6<978::aid-mrm22>3.0.co;2-9 · Cited by 167 · cited 1×
“5T whereas 3T optimization is now only being performed[51,52] As 3T scanners gain a wider market share, this concern will most likely disappear.”
Donahue, K. M., Weisskoff, R. M., Chesler, D. A., Kwong, K. K., Bogdanov, A. A., Mandeville, J. B., & Rosen, B. R. (1996) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910360608 · Cited by 165 · cited 1×
“Finally, there may be some uncertainty as to whether it is reasonable to assume that all the water in the tissue is equally exposed to the contrast agent ("fast exchange" condition) [61].”
Feasibility of tissue magnetic resonance imaging
Paelinck, B. P., Roos, A., Bax, J. J., Bosmans, J. M., van der Geest, R. J., Dhondt, D., Parizel, P. M., Vrints, C. J., & Lamb, H. J. (2005) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2004.12.051 · Cited by 152 · cited 1×
“Incorporating other measurements, such as presence of significant valvular disease and velocity-encoded data to assess diastolic function[89]1, allows a brief, single CMR exam to provide comprehensive assessment for etiologies of cardiovascular signs and symptoms that might otherwise require multiple testing and, ther…”
Dynamic contrast‐enhanced myocardial perfusion imaging using saturation‐prepared TrueFISP
Schreiber, W., Schmitt, M., Kalden, P., Mohrs, O. K., Kreitner, K., & THELEN, M. (2002) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.10209 · Cited by 134 · cited 4×
“The work done by Arai,[37] Fenchel et al.,[41] and Schreiber et al. [39] attributes magnetic susceptibility, associated with the concentration of Gd-DTPA in the bolus, as a possible cause for the DRA.”
InfluentialPlein, S., Radjenovic, A., Ridgway, J. P., Barmby, D. S., Greenwood, J. P., Ball, S. G., & Sivananthan, M. U. (2005) · Radiology · doi:10.1148/radiol.2352040454 · Cited by 131 · cited 1×
“[91] upslope 92 64% 88% 82% 86%”
Comprehensive Cardiac Magnetic Resonance Imaging at 3.0 Tesla
Gutberlet, M., Noeske, R., Schwinge, K., Freyhardt, P., Felix, R., & Niendorf, T. (2006) · Investigative Radiology · doi:10.1097/01.rli.0000195840.50230.10 · Cited by 131 · cited 1×
“5T [48].”
Cury, R. C., Cattani, C. A. M., Gabure, L. A. G., Racy, D. J., GÓIS, J. M., Siebert, U., Lima, S. S., & Brady, T. J. (2006) · Radiology · doi:10.1148/radiol.2401051161 · Cited by 108 · cited 1×
“Similarly high accuracy was reported in other single-center studies[64,76,77] on a segmental basis alone.”
Effect of Gd‐DTPA‐BMA on blood and myocardial T1 at 1.5T and 3T in humans
Sharma, P., Socolow, J., Patel, S. J., Pettigrew, R. I., & Oshinski, J. N. (2006) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.20504 · Cited by 98
Cernicanu, A., & Axel, L. (2006) · Academic Radiology · doi:10.1016/j.acra.2006.02.040 · Cited by 87 · cited 1×
“For example, acquiring a "proton density" image at the same location can be used both to provide an "absolute" intensity scale and to correct for shading due to the use of local surface coils [59,60].”
Self-citationSabharwal, N. K., & Lahiri, A. (2003) · Heart · doi:10.1136/heart.89.11.1291 · Cited by 72 · cited 1×
“Single photon emission computed tomographic (SPECT) imaging of myocardial perfusion with 201TI or 99mTc-labeled agents is an established clinical standard [1-4], but has relatively poor spatial resolution, suffers from soft tissue attenuation artifacts, is not quantitative, and delivers a significant dose of ionizing…”
Kim, D. C., & Axel, L. (2005) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.20471 · Cited by 66 · cited 1×
“Nevertheless, precontrast T1 is higher for higher fields, making the difference of T1 before and after contrast larger for high fields and enabling an overall better contrast to noise ratio (CNR) for myocardial enhancement [36,47].”
Self-citationSusceptibility changes following bolus injections
Albert, M. S., Haung, W., Lee, J. H., Patlak, C. S., & SPRINGER, C. S. J. (1993) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910290520 · Cited by 64 · cited 1×
“Albert et al.[42] studied the mechanism of bulk magnetic susceptibility induced by a contrast agent bolus injection.”
Jerosch‐Herold, M., Hu, X., Murthy, N. S., Rickers, C., & Stillman, A. E. (2003) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.10384 · Cited by 61
Wang, Y., Moin, K., Akinboboye, O. O., & Reichek, N. (2005) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20700 · Cited by 54 · cited 1×
“Wang et al.[28] compared a b-SSFP sequence with spoiled GRE and segmented EPI in volunteers with no clinical history of CAD.”
OʼKonski, M. S., Fc, W., Longhurst, J., Roth, D. M., & Bloor, C. M. (1987) · PubMed · Cited by 46
Kim, D. C., Cernicanu, A., & Axel, L. (2005) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20704 · Cited by 43 · cited 3×
“Kim et al[21] evaluated favourably the use of a B1 Insensitive Rotation (BIR-4) saturation pulse to account for the field distortions.”
Self-citationKraitchman, D. L., Hillenbrand, H. B., Oznur, I., Lima, J. A. C., McVeigh, E. R., Zerhouni, E. A., & Bluemke, D. A. (2000) · Journal of Cardiovascular Magnetic Resonance · doi:10.3109/10976640009148681 · Cited by 15
Self-citation
Cited by
Fratz, S., Chung, T., Greil, G. F., Samyn, M. M., Taylor, A. M., Valsangiacomo Buechel, E. R., Yoo, S.-J., & Powell, A. J. (2013) · Journal of Cardiovascular Magnetic Resonance · doi:10.1186/1532-429x-15-51 · Cited by 507
Kilner, P. J., Geva, T., Kaemmerer, H., Trindade, P. T., Schwitter, J., & Webb, G. D. (2010) · European Heart Journal · doi:10.1093/eurheartj/ehp586 · Cited by 429
Cardiovascular Magnetic Resonance
Pennell, D. J. (2010) · Circulation · doi:10.1161/circulationaha.108.811547 · Cited by 338
Cardiovascular magnetic resonance physics for clinicians: part II
Biglands, J. D., Radjenovic, A., & Ridgway, J. P. (2012) · Journal of Cardiovascular Magnetic Resonance · doi:10.1186/1532-429x-14-66 · Cited by 241
“For a comprehensive and highly informative review of the causes of DRAs see [16].”
Influential
Metadata
- Authors
- Gerber, B. L., Raman, S. V., Nayak, K., Epstein, F. H., Ferreira, P., Axel, L., & Kraitchman, D. L.
- Venue
- Journal of Cardiovascular Magnetic Resonance
- Publisher
- Elsevier BV
- Published
- 2008-01
- Volume
- 10
- Issue
- 1
- Pages
- 18
- ISSN
- 1097-6647 (ISSN-L)
- OpenAlex
- W2137151313
- Cited by
- 219
- References
- 59
- FWCI
- 13.86
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.