Principles of Design and Analyses for the Calibration of Accelerometry-Based Activity Monitors
The DOI matches its Crossref record; 50 of the 50 references it cites were found in a registry or an index.
Abstract
The term "calibration" in accelerometry research has come to mean the conversion of counts into other established measurement units. In this article, two types of calibration research are described. Unit calibration (or interinstrument variability) is described as a reliability issue, whereas value calibration is described as more of a validity issue. Principles for design of accelerometry-based validation studies are described to provide a guide for future calibration research. The population must be representative of the intended population in terms of demographics and size, monitors must be representative of the population of monitors that would be available, and activities in the protocol must be representative of the types of activities performed by the intended population. It is also important to employ appropriate analytical strategies in this type of research. A case study employing the appropriate design principles is included to demonstrate how results can vary depending on the type of analyses that are used. Direct comparisons are made between a mixed model regression approach and an approach based on receiver operator characteristic curves.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Calibration of the Computer Science and Applications, Inc. accelerometer
FREEDSON, P. S., MELANSON, E., & SIRARD, J. (1998) · Medicine & Science in Sports & Exercise · doi:10.1097/00005768-199805000-00021 · Cited by 3,825
Calibration of Accelerometer Output for Children
FREEDSON, P., POBER, D., & JANZ, K. F. (2005) · Medicine & Science in Sports & Exercise · doi:10.1249/01.mss.0000185658.28284.ba · Cited by 1,104
Validation and Calibration of Physical Activity Monitors in Children
Puyau, M. R., Adolph, A. L., Vohra, F. A., & Butte, N. F. (2002) · Obesity Research · doi:10.1038/oby.2002.24 · Cited by 1,023
Physical activity levels and patterns of 9- and 15-yr-old European children
RIDDOCH, C. J., BO ANDERSEN, L., WEDDERKOPP, N., HARRO, M., KLASSON-HEGGEBØ, L., SARDINHA, L. B., COOPER, A. R., & EKELUND, U. (2004) · Medicine & Science in Sports & Exercise · doi:10.1249/01.mss.0000106174.43932.92 · Cited by 900
Validity of the computer science and applications (CSA) activity monitor in children
TROST, S. G., WARD, D. S., MOOREHEAD, S. M., WATSON, P. D., RINER, W., & BURKE, J. R. (1998) · Medicine & Science in Sports & Exercise · doi:10.1097/00005768-199804000-00023 · Cited by 769
Physical Activity Assessments for Health-Related Research
Welk, G. J. (2002) · Medical Entomology and Zoology · Cited by 688
Self-citationCalibration of Accelerometer Output for Adults
MATTHEW, C. E. (2005) · Medicine & Science in Sports & Exercise · doi:10.1249/01.mss.0000185659.11982.3d · Cited by 659
Prediction of activity energy expenditure using accelerometers in children.
Puyau, M. R., Adolph, A. L., Vohra, F. A., Zakeri, I., & Butte, N. F. (2004) · PubMed · Cited by 552
Validity of four motion sensors in measuring moderate intensity physical activity
BASSETT, D. R. (2000) · Medicine & Science in Sports & Exercise · doi:10.1097/00005768-200009001-00006 · Cited by 527
Validity of accelerometry for the assessment of moderate intensity physical activity in the field
HENDELMAN, D., MILLER, K., BAGGETT, C., DEBOLD, E., & FREEDSON, P. (2000) · Medicine & Science in Sports & Exercise · doi:10.1097/00005768-200009001-00002 · Cited by 516
Cited by
Comparison of Accelerometer Cut Points for Predicting Activity Intensity in Youth
TROST, S. G., LOPRINZI, P. D., MOORE, R., & PFEIFFER, K. A. (2011) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e318206476e · Cited by 1,360
Strath, S. J., Kaminsky, L. A., Ainsworth, B. E., Ekelund, U., Freedson, P. S., Gary, R. A., Richardson, C. R., Smith, D. T., & Swartz, A. M. (2013) · Circulation · doi:10.1161/01.cir.0000435708.67487.da · Cited by 1,029
The Technology of Accelerometry-Based Activity Monitors: Current and Future
CHEN, K. Y., & BASSETT, D. R. (2005) · Medicine & Science in Sports & Exercise · doi:10.1249/01.mss.0000185571.49104.82 · Cited by 996
Evolution of accelerometer methods for physical activity research
Troiano, R. P., McClain, J. J., Brychta, R. J., & Chen, K. Y. (2014) · British Journal of Sports Medicine · doi:10.1136/bjsports-2014-093546 · Cited by 968
Accelerometer Use in Physical Activity: Best Practices and Research Recommendations
WARD, D. S., EVENSON, K. R., VAUGHN, A., RODGERS, A. B., & TROIANO, R. P. (2005) · Medicine & Science in Sports & Exercise · doi:10.1249/01.mss.0000185292.71933.91 · Cited by 779
Using Accelerometers in Youth Physical Activity Studies: A Review of Methods
Cain, K. L., Sallis, J. F., Conway, T. L., Van Dyck, D., & Calhoon, L. (2013) · Journal of Physical Activity and Health · doi:10.1123/jpah.10.3.437 · Cited by 713
Validation of the GENEA Accelerometer
ESLIGER, D. W., ROWLANDS, A. V., HURST, T. L., CATT, M., MURRAY, P., & ESTON, R. G. (2011) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e31820513be · Cited by 625
Accelerometry: A technique for quantifying movement patterns during walking
Kavanagh, J. J., & Menz, H. B. (2008) · Gait & Posture · doi:10.1016/j.gaitpost.2007.10.010 · Cited by 617
Warren, J. M., Ekelund, U., Besson, H., Mezzani, A., Geladas, N., & Vanhees, L. (2010) · European Journal of Cardiovascular Prevention & Rehabilitation · doi:10.1097/hjr.0b013e32832ed875 · Cited by 587
Translating Physical Activity Recommendations into a Pedometer-Based Step Goal
Marshall, S. J., Levy, S. S., Tudor-Locke, C. E., Kolkhorst, F. W., Wooten, K. M., Ji, M., Macera, C. A., & Ainsworth, B. E. (2009) · American Journal of Preventive Medicine · doi:10.1016/j.amepre.2009.01.021 · Cited by 447
Accelerometer Assessment of Physical Activity in Active, Healthy Older Adults
Copeland, J. L., & Esliger, D. W. (2009) · Journal of Aging and Physical Activity · doi:10.1123/japa.17.1.17 · Cited by 412
State of the Art Reviews: Measurement of Physical Activity in Children and Adolescents
Trost, S. G. (2007) · American Journal of Lifestyle Medicine · doi:10.1177/1559827607301686 · Cited by 404
Dowd, K. P., Szeklicki, R., Minetto, M. A., Murphy, M. H., Polito, A., Ghigo, E., van der Ploeg, H., Ekelund, U., Maciaszek, J., Stemplewski, R., et al. (2018) · International Journal of Behavioral Nutrition and Physical Activity · doi:10.1186/s12966-017-0636-2 · Cited by 385
“Selected self-reported measures of physical activity Adults and Youth (age not specified) Narrative Review Not Appropriate Welk (2005) [68] 1.”
MethodLang, C. E., Bland, M. D., Bailey, R. R., Schaefer, S. Y., & Birkenmeier, R. L. (2013) · Journal of Hand Therapy · doi:10.1016/j.jht.2012.06.005 · Cited by 385
Accelerometer-based measures in physical activity surveillance: current practices and issues
Pedišić, Ž., & Bauman, A. (2015) · British Journal of Sports Medicine · doi:10.1136/bjsports-2013-093407 · Cited by 330
Murphy, S. L. (2009) · Preventive Medicine · doi:10.1016/j.ypmed.2008.12.001 · Cited by 326
Methods for objective measure, quantification and analysis of sedentary behaviour and inactivity
Chastin, S. F. M., & Granat, M. H. (2010) · Gait & Posture · doi:10.1016/j.gaitpost.2009.09.002 · Cited by 323
“Using an energy threshold leads to large uncertainty about the sedentary data recorded, first of all because estimating energy expenditure from accelerometer data is not robust [24] and the length of sedentary period extracted will be very sensitive to the to the metabolic equivalent of task (MET) cut-off point chosen…”
BackgroundReliability and Validity of the IPAQ-Chinese: The Guangzhou Biobank Cohort Study
DENG, H. B., MACFARLANE, D. J., THOMAS, G. N., LAO, X. Q., JIANG, C. Q., CHENG, K. K., & LAM, T. H. (2008) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e31815b0db5 · Cited by 319
Calibration and Validation of Wearable Monitors
BASSETT, D. R., ROWLANDS, A., & TROST, S. G. (2012) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e3182399cf7 · Cited by 292
Chandler, J. L., Brazendale, K., Beets, M. W., & Mealing, B. A. (2016) · Pediatric Obesity · doi:10.1111/ijpo.12033 · Cited by 275
Prediction of Energy Expenditure and Physical Activity in Preschoolers
BUTTE, N. F., WONG, W. W., LEE, J. S., ADOLPH, A. L., PUYAU, M. R., & ZAKERI, I. F. (2014) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0000000000000209 · Cited by 273
Calibration of an accelerometer during free-living activities in children
Mattocks, C., Leary, S., Ness, A., Deere, K., Saunders, J., Tilling, K., Kirkby, J., Blair, S. N., & Riddoch, C. (2007) · International Journal of Pediatric Obesity · doi:10.1080/17477160701408809 · Cited by 271
Accuracy and Reliability of the Kinect Version 2 for Clinical Measurement of Motor Function
Otte, K., Kayser, B., Mansow-Model, S., Verrel, J., Paul, F., Brandt, A. U., & Schmitz-Hübsch, T. (2016) · PLOS ONE · doi:10.1371/journal.pone.0166532 · Cited by 255
Comparison of three generations of ActiGraph™ activity monitors in children and adolescents
Robusto, K. M., & Trost, S. G. (2012) · Journal of Sports Sciences · doi:10.1080/02640414.2012.710761 · Cited by 254
Jones, M., Defever, E., Letsinger, A., Steele, J., & Mackintosh, K. A. (2020) · Journal of Sport and Health Science · doi:10.1016/j.jshs.2019.06.009 · Cited by 189
Validity of physical activity monitors in adults participating in free-living activities
Berntsen, S., Hageberg, R., Aandstad, A., Mowinckel, P., Anderssen, S. A., Carlsen, K.-H., & Andersen, L. B. (2010) · British Journal of Sports Medicine · doi:10.1136/bjsm.2008.048868 · Cited by 191
“and calculation of energy expenditure from oxygen consumption data should ideally adjust for which substrates that are undergoing oxidation.”
BackgroundAgreement between activPAL and ActiGraph for assessing children's sedentary time
Ridgers, N. D., Salmon, J., Ridley, K., O'Connell, E., Arundell, L., & Timperio, A. (2012) · International Journal of Behavioral Nutrition and Physical Activity · doi:10.1186/1479-5868-9-15 · Cited by 191
“Welk GJ: Principles of design and analyses for the calibration of accelerometry-based activity monitors.”
BackgroundMethodInfluentialMacfarlane, D., Chan, A., & Cerin, E. (2011) · Public Health Nutrition · doi:10.1017/s1368980010002806 · Cited by 184
“Accelerometers are well known to underestimate not only several forms of PA((13)), but also the energy cost of free-living activities, especially when using regression equations derived from moderate and vigorous intensity cut-off points that vary within the literature((20,46)).”
BackgroundMethodComparing the performance of three generations of ActiGraph accelerometers
Rothney, M. P., Apker, G. A., Song, Y., & Chen, K. Y. (2008) · Journal of Applied Physiology · doi:10.1152/japplphysiol.90641.2008 · Cited by 177
Modeling Physical Activity Outcomes from Wearable Monitors
HEIL, D. P., BRAGE, S., & ROTHNEY, M. P. (2012) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e3182399dcc · Cited by 121
“Although the scope and impact of the cut point problem (8,16), as well as alternative strategies for computing cut points (30), have been thoroughly acknowledged in the literature, an appropriate alternative analytical strategy has yet to be well”
BackgroundEvaluation of a walking school bus for promoting physical activity in youth
Heelan, K. A., Abbey, B. M., Donnelly, J. E., Mayo, M. S., & Welk, G. J. (2009) · Journal of Physical Activity and Health · doi:10.1123/jpah.6.5.560 · Cited by 94
Self-citationTierney, M., Fraser, A., Purtill, H., & Kennedy, N. (2013) · Arthritis Care & Research · doi:10.1002/acr.21914 · Cited by 56
Boeselt, T., Spielmanns, M., Nell, C., Storre, J. H., Windisch, W., Magerhans, L., Beutel, B., Kenn, K., Greulich, T., Alter, P., et al. (2016) · PLOS ONE · doi:10.1371/journal.pone.0157229 · Cited by 35
“The difference in the daily activity time may be influenced by different algorithm calculation of the producer [21] or systemic deviation witch largely remain in the range of +/- SD or the number of patients.”
BackgroundVanhelst, J., Béghin, L., Salleron, J., Ruiz, J. R., Ortega, F. B., Ottevaere, C., Molnar, D., Kafatos, A., Manios, Y., Widhalm, K., et al. (2014) · Journal of Sports Sciences · doi:10.1080/02640414.2013.809473 · Cited by 17
“…consumption, heart rate); (iii) inclusion of representative activities (i.e. diverse activities that are representative of activities in FLC); and (iv) appropriate analytic methods (i.e. appropriate statistical analysis, presence of a cross-validation group) (Welk, 2005; Vanhelst et al., 2010b).”
Method
Metadata
- Authors
- WELK, G. J.
- Venue
- Medicine & Science in Sports & Exercise
- Published
- 2005-11
- Volume
- 37
- Issue
- 11
- Pages
- S501-S511
- ISSN
- 0195-9131 (ISSN-L)
- OpenAlex
- W2030168699
- Cited by
- 339
- References
- 50
- FWCI
- 6.93
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.