Principles of Design and Analyses for the Calibration of Accelerometry-Based Activity Monitors
Abstract
The term "calibration" in accelerometry research has come to mean the conversion of counts into other established measurement units. In this article, two types of calibration research are described. Unit calibration (or interinstrument variability) is described as a reliability issue, whereas value calibration is described as more of a validity issue. Principles for design of accelerometry-based validation studies are described to provide a guide for future calibration research. The population must be representative of the intended population in terms of demographics and size, monitors must be representative of the population of monitors that would be available, and activities in the protocol must be representative of the types of activities performed by the intended population. It is also important to employ appropriate analytical strategies in this type of research. A case study employing the appropriate design principles is included to demonstrate how results can vary depending on the type of analyses that are used. Direct comparisons are made between a mixed model regression approach and an approach based on receiver operator characteristic curves.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Calibration of the Computer Science and Applications, Inc. accelerometer
FREEDSON, P. S., MELANSON, E., & SIRARD, J. (1998) · Medicine & Science in Sports & Exercise · doi:10.1097/00005768-199805000-00021 · Cited by 3,825
Calibration of Accelerometer Output for Children
FREEDSON, P., POBER, D., & JANZ, K. F. (2005) · Medicine & Science in Sports & Exercise · doi:10.1249/01.mss.0000185658.28284.ba · Cited by 1,104
Validation and Calibration of Physical Activity Monitors in Children
Puyau, M. R., Adolph, A. L., Vohra, F. A., & Butte, N. F. (2002) · Obesity Research · doi:10.1038/oby.2002.24 · Cited by 1,023
Physical activity levels and patterns of 9- and 15-yr-old European children
RIDDOCH, C. J., BO ANDERSEN, L., WEDDERKOPP, N., HARRO, M., KLASSON-HEGGEBØ, L., SARDINHA, L. B., COOPER, A. R., & EKELUND, U. (2004) · Medicine & Science in Sports & Exercise · doi:10.1249/01.mss.0000106174.43932.92 · Cited by 900
Validity of the computer science and applications (CSA) activity monitor in children
TROST, S. G., WARD, D. S., MOOREHEAD, S. M., WATSON, P. D., RINER, W., & BURKE, J. R. (1998) · Medicine & Science in Sports & Exercise · doi:10.1097/00005768-199804000-00023 · Cited by 769
Physical Activity Assessments for Health-Related Research
Welk, G. J. (2002) · Medical Entomology and Zoology · Cited by 688
Self-citationCalibration of Accelerometer Output for Adults
MATTHEW, C. E. (2005) · Medicine & Science in Sports & Exercise · doi:10.1249/01.mss.0000185659.11982.3d · Cited by 659
Prediction of activity energy expenditure using accelerometers in children.
Puyau, M. R., Adolph, A. L., Vohra, F. A., Zakeri, I., & Butte, N. F. (2004) · PubMed · Cited by 552
Validity of four motion sensors in measuring moderate intensity physical activity
BASSETT, D. R. (2000) · Medicine & Science in Sports & Exercise · doi:10.1097/00005768-200009001-00006 · Cited by 527
Validity of accelerometry for the assessment of moderate intensity physical activity in the field
HENDELMAN, D., MILLER, K., BAGGETT, C., DEBOLD, E., & FREEDSON, P. (2000) · Medicine & Science in Sports & Exercise · doi:10.1097/00005768-200009001-00002 · Cited by 516
Estimation of energy expenditure using CSA accelerometers at hip and wrist sites
SWARTZ, A. M., STRATH, S. J., BASSETT, D. R., O???BRIEN, W. L., KING, G. A., & AINSWORTH, B. E. (2000) · Medicine & Science in Sports & Exercise · doi:10.1097/00005768-200009001-00003 · Cited by 513
Defining Accelerometer Thresholds for Activity Intensities in Adolescent Girls
The University of North Carolina at Chapel Hill University Libraries (2020) · Carolina Digital Repository (University of North Carolina at Chapel Hill) · doi:10.17615/zfsn-y805 · Cited by 496
Compliance with physical activity guidelines: prevalence in a population of children and youth
Pate, R. (2002) · Annals of Epidemiology · doi:10.1016/s1047-2797(01)00263-0 · Cited by 472
Physical activity assessed by activity monitor and doubly labeled water in children
EKELUND, U., SJÖSTRÖM, M., YNGVE, A., POORTVLIET, E., NILSSON, A., FROBERG, K., WEDDERKOPP, N., & WESTERTERP, K. (2001) · Medicine & Science in Sports & Exercise · doi:10.1097/00005768-200102000-00017 · Cited by 441
Reliability of accelerometry-based activity monitors: a generalizability study.
Welk, G. J., Schaben, J. A., & Morrow, J. R. (2004) · PubMed · Cited by 397
Self-citationReexamination of Validity and Reliability of the CSA Monitor in Walking and Running
BRAGE, S., WEDDERKOPP, N., FRANKS, P. W., BO ANDERSEN, L., & FROBERG, K. (2003) · Medicine & Science in Sports & Exercise · doi:10.1249/01.mss.0000079078.62035.ec · Cited by 347
A comparative evaluation of three accelerometry-based physical activity monitors
WELK, G. J., BLAIR, S. N., WOOD, K., JONES, S., & THOMPSON, R. W. (2000) · Medicine & Science in Sports & Exercise · doi:10.1097/00005768-200009001-00008 · Cited by 343
Self-citationMeasurement of Human Daily Physical Activity
Zhang, K., Werner, P., Sun, M., Pi‐Sunyer, F. X., & Boozer, C. N. (2003) · Obesity Research · doi:10.1038/oby.2003.7 · Cited by 306
An Objective Method for Measurement of Sedentary Behavior in 3‐ to 4‐Year Olds
Reilly, J. J., Coyle, J., Kelly, L., Burke, G., Grant, S., & Paton, J. Y. (2003) · Obesity Research · doi:10.1038/oby.2003.158 · Cited by 240
Comparison of Activity Monitors to Estimate Energy Cost of Treadmill Exercise
KING, G. A., TORRES, N., POTTER, C., BROOKS, T. J., & COLEMAN, K. J. (2004) · Medicine & Science in Sports & Exercise · doi:10.1249/01.mss.0000132379.09364.f8 · Cited by 238
Bouten, C. V., Verboeket-van de Venne, W. P., Westerterp, K. R., Verduin, M., & Janssen, J. D. (1996) · Journal of Applied Physiology · doi:10.1152/jappl.1996.81.2.1019 · Cited by 223
Children's Activity Rating Scale (CARS): Description and Calibration
Puhl, J., Greaves, K., Hoyt, M., & Baranowski, T. (1990) · Research Quarterly for Exercise and Sport · doi:10.1080/02701367.1990.10607475 · Cited by 219
Improving energy expenditure estimation by using a triaxial accelerometer
Chen, K. Y., & Sun, M. (1997) · Journal of Applied Physiology · doi:10.1152/jappl.1997.83.6.2112 · Cited by 211
Improving Energy Expenditure Estimation for Physical Activity
ZHANG, K., PI-SUNYER, F. X., & BOOZER, C. N. (2004) · Medicine & Science in Sports & Exercise · doi:10.1249/01.mss.0000126585.40962.22 · Cited by 180
NICHOLS, J. F., MORGAN, C. G., SARKIN, J. A., SALLIS, J. F., & CALFAS, K. J. (1999) · Medicine & Science in Sports & Exercise · doi:10.1097/00005768-199906000-00022 · Cited by 178
Field evaluation of the Computer Science and Applications, Inc. physical activity monitor
Sirard, J. R., Melanson, E. L., Li, L., & Freedson, P. S. (2000) · Medicine & Science in Sports & Exercise · doi:10.1097/00005768-200003000-00022 · Cited by 164
Comparisons of four methods of estimating physical activity in adult women
LEENDERS, N. Y. J. M., SHERMAN, W. M., & NAGARAJA, H. N. (2000) · Medicine & Science in Sports & Exercise · doi:10.1097/00005768-200007000-00021 · Cited by 161
The reliability, validity, and stability of a measure of physical activity in the elderly
Kochersberger, G., McConnell, E., Kuchibhatla, M. N., & Pieper, C. (1996) · Archives of Physical Medicine and Rehabilitation · doi:10.1016/s0003-9993(96)90258-0 · Cited by 159
A Longitudinal Study of Fitness and Activity in Girls Predisposed to Obesity
Treuth, M. S., Butte, N. F., Adolph, A. L., & Puyau, M. R. (2004) · Medicine & Science in Sports & Exercise · doi:10.1249/01.mss.0000113666.98463.b0 · Cited by 154
Bouten, C. V. C., Sauren, A. A. H. J., Verduin, M., & Janssen, J. J. (1997) · Medical & Biological Engineering & Computing · doi:10.1007/bf02510392 · Cited by 151
The accuracy of the TriTrac-R3D accelerometer to estimate energy expenditure
Jakicic, J. M., Winters, C., Lagally, K. M., HO, J., Robertson, R. J., & Wing, R. R. (1999) · Medicine & Science in Sports & Exercise · doi:10.1097/00005768-199905000-00020 · Cited by 149
Technical reliability of the CSA activity monitor: The EarlyBird Study
Metcalf, B. S., Curnow, J. S. H., EVANS, C. J., Voss, L. D., & Wilkin, T. J. (2002) · Medicine & Science in Sports & Exercise · doi:10.1097/00005768-200209000-00022 · Cited by 144
Using the Computer Science and Applications (CSA) Activity Monitor in Preschool Children
Fairweather, S. C., Reilly, J. J., Grant, S., Whittaker, A. R., & Paton, J. Y. (1999) · Pediatric Exercise Science · doi:10.1123/pes.11.4.413 · Cited by 141
Ekelund, U., Yngve, A., Brage, S., Westerterp, K. R., & Sjöstróm, M. (2004) · American Journal of Clinical Nutrition · doi:10.1093/ajcn/79.5.851 · Cited by 140
Differences in Physical Activity Between Black and White Girls Living in Rural and Urban Areas
Felton, G., Dowda, M. C., Ward, D. S., Dishman, R. K., Trost, S. G., Saunders, R. P., & Pate, R. R. (2002) · Journal of School Health · doi:10.1111/j.1746-1561.2002.tb07338.x · Cited by 127
Field trial of a three-dimensional activity monitor: comparison with self report
Matthews, C. E., & Freedson, P. S. (1995) · Medicine & Science in Sports & Exercise · doi:10.1249/00005768-199507000-00017 · Cited by 126
Comparison of MTI Accelerometer Cut-Points for Predicting Time Spent in Physical Activity
Strath, S. J., Bassett, D. R., & Swartz, A. M. (2003) · International Journal of Sports Medicine · doi:10.1055/s-2003-39504 · Cited by 110
Estimating Physical Activity Using the CSA Accelerometer and a Physical Activity Log
Schmidt, M. D., Freedson, P. S., & Chasan‐Taber, L. (2003) · Medicine & Science in Sports & Exercise · doi:10.1249/01.mss.0000084421.97661.17 · Cited by 106
Field evaluation of energy expenditure in women using Tritrac accelerometers
Campbell, K. L., Crocker, P. R. E., & McKenzie, D. C. (2002) · Medicine & Science in Sports & Exercise · doi:10.1097/00005768-200210000-00020 · Cited by 106
Brage, S., Brage, N., Wedderkopp, N., & Froberg, K. (2003) · Measurement in Physical Education and Exercise Science · doi:10.1207/s15327841mpee0702_4 · Cited by 95
Accuracy and reliability of the Caltrac accelerometer for estimating energy expenditure
Pambianco, G., Wing, R. R., & Robertson, R. J. (1990) · Medicine & Science in Sports & Exercise · doi:10.1249/00005768-199012000-00020 · Cited by 94
Comparison of accelerometers with oxygen consumption in older adults during exercise
Fehling, P. C., Smith, D. L., Warner, S., & Dalsky, G. P. (1999) · Medicine & Science in Sports & Exercise · doi:10.1097/00005768-199901000-00026 · Cited by 85
Brage, S., Wedderkopp, N., Andersen, L. B., & Froberg, K. (2003) · Pediatric Exercise Science · doi:10.1123/pes.15.3.277 · Cited by 85
Validity of uniaxial accelerometry during activities of daily living in children
Eisenmann, J. C., Strath, S. J., Shadrick, D., Rigsby, P., Hirsch, N. M., & Jacobson, L. (2004) · European Journal of Applied Physiology · doi:10.1007/s00421-003-0983-3 · Cited by 82
Walking and running energy expenditure estimated by Caltrac and indirect calorimetry
Haymes, E. M., & Byrnes, W. C. (1993) · Medicine & Science in Sports & Exercise · doi:10.1249/00005768-199312000-00008 · Cited by 80
Johnson, R., Russ, J., & Goran, M. (1998) · International Journal of Obesity · doi:10.1038/sj.ijo.0800723 · Cited by 72
Laboratory Calibration and Validation of the Biotrainer and Actitrac Activity Monitors
Welk, G. J., ALMEIDA, J., & Morss, G. M. (2003) · Medicine & Science in Sports & Exercise · doi:10.1249/01.mss.0000069525.56078.22 · Cited by 62
Self-citationCalorimetric Validation of the Caltrac® Accelerometer during Level Walking
Balogun, J. A., Martin, D. A., & Clendenin, M. A. (1989) · Physical Therapy · doi:10.1093/ptj/69.6.501 · Cited by 57
HEART RATE AS AN INDICATOR OF PHYSICAL ACTIVITY INTENSITY IN ADOLESCENTS
Ekelund, U., Poortvliet, E., Yngve, A., Nilsson, A. E., f, A. H.-W., & m, M. S. S. (2001) · Medicine & Science in Sports & Exercise · doi:10.1097/00005768-200105001-01406 · Cited by 50
Novel Technique for Assessing Physical Activity Using Accelerometer Data
POBER, D. M., Raphael, C., & Freedson, P. S. (2004) · Medicine & Science in Sports & Exercise · doi:10.1097/00005768-200405001-00946 · Cited by 2
Cited by
Comparison of Accelerometer Cut Points for Predicting Activity Intensity in Youth
TROST, S. G., LOPRINZI, P. D., MOORE, R., & PFEIFFER, K. A. (2011) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e318206476e · Cited by 1,360
Strath, S. J., Kaminsky, L. A., Ainsworth, B. E., Ekelund, U., Freedson, P. S., Gary, R. A., Richardson, C. R., Smith, D. T., & Swartz, A. M. (2013) · Circulation · doi:10.1161/01.cir.0000435708.67487.da · Cited by 1,029
The Technology of Accelerometry-Based Activity Monitors: Current and Future
CHEN, K. Y., & BASSETT, D. R. (2005) · Medicine & Science in Sports & Exercise · doi:10.1249/01.mss.0000185571.49104.82 · Cited by 996
Evolution of accelerometer methods for physical activity research
Troiano, R. P., McClain, J. J., Brychta, R. J., & Chen, K. Y. (2014) · British Journal of Sports Medicine · doi:10.1136/bjsports-2014-093546 · Cited by 968
Accelerometer Use in Physical Activity: Best Practices and Research Recommendations
WARD, D. S., EVENSON, K. R., VAUGHN, A., RODGERS, A. B., & TROIANO, R. P. (2005) · Medicine & Science in Sports & Exercise · doi:10.1249/01.mss.0000185292.71933.91 · Cited by 779
Metadata
- Authors
- WELK, G. J.
- Venue
- Medicine & Science in Sports & Exercise
- Published
- 2005-11
- Volume
- 37
- Issue
- 11
- Pages
- S501-S511
- ISSN
- 0195-9131 (ISSN-L)
- OpenAlex
- W2030168699
- Cited by
- 339
- References
- 50
- FWCI
- 6.93
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.