Technical Reliability Assessment of Three Accelerometer Models in a Mechanical Setup
The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
PURPOSE: To determine which of the three most commonly used accelerometer models has the best intra- and interinstrument reliability using a mechanical laboratory setup. Secondly, to determine the effects that acceleration and frequency have on these reliability measures. METHODS: Three experiments were performed. In the first, five each of the Actical, Actigraph, and RT3 accelerometers were placed on a hydraulic shaker plate and simultaneously accelerated in the vertical plane at varying accelerations and frequencies. Six different conditions of varying intensity were used to produce a range of accelerometer counts. Reliability was calculated using standard deviation, standard error of the measurement, coefficient of variation, and intraclass correlation coefficients. In the second and third experiments, 39 Actical and 50 Actigraph accelerometers were put through the same six conditions. RESULTS: Experiment 1 showed poor reliability in the RT3 (intra- and interinstrument CV > 40%). Experiments 2 and 3 clearly indicated that the Actical (CVintra = 0.5%, CVinter = 5.4%) was more reliable than the Actigraph (CVintra = 3.2%, CVinter = 8.6%). Variability in the Actical was negatively related to the acceleration of the condition, whereas no relationship was found between acceleration and reliability in the Actigraph. Variability in the Actigraph was negatively related to the frequency of the condition, whereas no relationship was found between frequency and reliability in the Actical. CONCLUSION: Of the three accelerometer models measured in this study, the Actical had the best intra- and interinstrument reliability. However, discrepant trends in the variability of Actical and Actigraph counts across accelerations and frequencies preclude the selection of a superior model. More work is needed to understand why accelerometers designed to measure the same thing behave so differently.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Conducting accelerometer-based activity assessments in field-based research
TROST, S. G., MCIVER, K. L., & PATE, R. R. (2005) · Medicine & Science in Sports & Exercise · doi:10.1249/01.mss.0000185657.86065.98 · Cited by 2,033
The Technology of Accelerometry-Based Activity Monitors: Current and Future
CHEN, K. Y., & BASSETT, D. R. (2005) · Medicine & Science in Sports & Exercise · doi:10.1249/01.mss.0000185571.49104.82 · Cited by 996
Accelerometer Use in Physical Activity: Best Practices and Research Recommendations
WARD, D. S., EVENSON, K. R., VAUGHN, A., RODGERS, A. B., & TROIANO, R. P. (2005) · Medicine & Science in Sports & Exercise · doi:10.1249/01.mss.0000185292.71933.91 · Cited by 779
Validity of the computer science and applications (CSA) activity monitor in children
TROST, S. G., WARD, D. S., MOOREHEAD, S. M., WATSON, P. D., RINER, W., & BURKE, J. R. (1998) · Medicine & Science in Sports & Exercise · doi:10.1097/00005768-199804000-00023 · Cited by 769
Cited by
Calibration of two objective measures of physical activity for children
Evenson, K. R., Catellier, D. J., Gill, K., Ondrak, K. S., & McMurray, R. G. (2008) · Journal of Sports Sciences · doi:10.1080/02640410802334196 · Cited by 2,677
Strath, S. J., Kaminsky, L. A., Ainsworth, B. E., Ekelund, U., Freedson, P. S., Gary, R. A., Richardson, C. R., Smith, D. T., & Swartz, A. M. (2013) · Circulation · doi:10.1161/01.cir.0000435708.67487.da · Cited by 1,029
Shephard, R. J. (2011) · Yearbook of Sports Medicine · doi:10.1016/j.yspm.2011.03.006 · Cited by 877
Young, D. R., Hivert, M.-F., Alhassan, S., Camhi, S. M., Ferguson, J. F., Katzmarzyk, P. T., Lewis, C. E., Owen, N., Perry, C. K., Siddique, J., et al. (2016) · Circulation · doi:10.1161/cir.0000000000000440 · Cited by 791
Validation of the GENEA Accelerometer
ESLIGER, D. W., ROWLANDS, A. V., HURST, T. L., CATT, M., MURRAY, P., & ESTON, R. G. (2011) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e31820513be · Cited by 625
Self-citationWarren, J. M., Ekelund, U., Besson, H., Mezzani, A., Geladas, N., & Vanhees, L. (2010) · European Journal of Cardiovascular Prevention & Rehabilitation · doi:10.1097/hjr.0b013e32832ed875 · Cited by 587
Diaz, K. M., Howard, V. J., Hutto, B., Colabianchi, N., Vena, J. E., Safford, M. M., Blair, S. N., & Hooker, S. P. (2017) · Annals of Internal Medicine · doi:10.7326/m17-0212 · Cited by 530
The contribution of office work to sedentary behaviour associated risk
Parry, S., & Straker, L. (2013) · BMC Public Health · doi:10.1186/1471-2458-13-296 · Cited by 501
Accelerometer Assessment of Physical Activity in Active, Healthy Older Adults
Copeland, J. L., & Esliger, D. W. (2009) · Journal of Aging and Physical Activity · doi:10.1123/japa.17.1.17 · Cited by 412
Self-citationAccelerometers and pedometers: methodology and clinical application
Corder, K., Brage, S., & Ekelund, U. (2007) · Current Opinion in Clinical Nutrition and Metabolic Care · doi:10.1097/mco.0b013e328285d883 · Cited by 339
Accelerometer-based measures in physical activity surveillance: current practices and issues
Pedišić, Ž., & Bauman, A. (2015) · British Journal of Sports Medicine · doi:10.1136/bjsports-2013-093407 · Cited by 330
Murphy, S. L. (2009) · Preventive Medicine · doi:10.1016/j.ypmed.2008.12.001 · Cited by 326
How Active Are People With Stroke?: Use of Accelerometers to Assess Physical Activity
Rand, D., Eng, J. J., Tang, P.-F., Jeng, J.-S., & Hung, C. (2009) · Stroke · doi:10.1161/strokeaha.108.523621 · Cited by 325
Reliability of the Actigraph GT3X+ Accelerometer in Adults under Free-Living Conditions
Aadland, E., & Ylvisåker, E. (2015) · PLOS ONE · doi:10.1371/journal.pone.0134606 · Cited by 313
Evenson, K., Buchner, D., & Morland, K. (2011) · Preventing Chronic Disease · doi:10.5888/pcd9.110109 · Cited by 267
Age and Gender Differences in Youth Physical Activity: Does Physical Maturity Matter?
SHERAR, L. B., ESLIGER, D. W., BAXTER-JONES, A. D. G., & TREMBLAY, M. S. (2007) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e3180335c3c · Cited by 254
Self-citationEstimating Activity and Sedentary Behavior from an Accelerometer on the Hip or Wrist
ROSENBERGER, M. E., HASKELL, W. L., ALBINALI, F., MOTA, S., NAWYN, J., & INTILLE, S. (2013) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e31827f0d9c · Cited by 237
“None of the reports using these advanced analytical procedures on data collected at the wrist have estimated AEE; they have predicted physical activity type and intensity categories (2, 3, 13, 32, 45).”
Adam Noah, J., Spierer, D. K., Gu, J., & Bronner, S. (2013) · Journal of Medical Engineering & Technology · doi:10.3109/03091902.2013.831135 · Cited by 202
“validity [10–28].”
Technical variability of the GT3X accelerometer
Santos-Lozano, A., Marín, P. J., Torres-Luque, G., Ruiz, J. R., Lucía, A., & Garatachea, N. (2012) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2012.02.005 · Cited by 180
“7% with the ActiGraph 7164 model [5], or values in he order of 0.”
BackgroundResultInfluentialComparing the performance of three generations of ActiGraph accelerometers
Rothney, M. P., Apker, G. A., Song, Y., & Chen, K. Y. (2008) · Journal of Applied Physiology · doi:10.1152/japplphysiol.90641.2008 · Cited by 177
Patterns of sedentary time and cardiometabolic risk among Canadian adults
Carson, V., Wong, S. L., Winkler, E., Healy, G. N., Colley, R. C., & Tremblay, M. S. (2014) · Preventive Medicine · doi:10.1016/j.ypmed.2014.04.005 · Cited by 172
Self-citationEvaluation of Activity Monitors in Controlled and Free-Living Environments
FEITO, Y., BASSETT, D. R., & THOMPSON, D. L. (2012) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e3182351913 · Cited by 159
Physical Activity after Stroke: A Systematic Review and Meta-Analysis
Field, M. J., Gebruers, N., Shanmuga Sundaram, T., Nicholson, S., & Mead, G. (2013) · ISRN Stroke · doi:10.1155/2013/464176 · Cited by 143
Validation of photoplethysmography as a method to detect heart rate during rest and exercise
Spierer, D. K., Rosen, Z., Litman, L. L., & Fujii, K. (2015) · Journal of Medical Engineering & Technology · doi:10.3109/03091902.2015.1047536 · Cited by 139
“Prior studies examining accelerometer-based wearable technology have shown these devices to be reliable and valid in both children [9–11] and adults [10,12,13].”
BackgroundProtocols for evaluating equivalency of accelerometry-based activity monitors
WELK, G. J., MCCLAIN, J., & AINSWORTH, B. E. (2012) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e3182399d8f · Cited by 124
“, turntables, wheels, vibration tables, or shaker tables) to impart a standardized movement or acceleration to multiple units of a monitor model (6,10,14, 21,24,27).”
BackgroundInfluentialHale, L. A., Pal, J., & Becker, I. (2008) · Archives of Physical Medicine and Rehabilitation · doi:10.1016/j.apmr.2008.02.027 · Cited by 118
Duval, K., Strychar, I., Cyr, M.-J., Prud'homme, D., Rabasa-Lhoret, R., & Doucet, É. (2008) · The American Journal of Clinical Nutrition · doi:10.3945/ajcn.2008.26220 · Cited by 73
Evans, D. S., Snitker, S., Wu, S.-H., Mody, A., Njajou, O. T., Perlis, M. L., Gehrman, P. R., Shuldiner, A. R., & Hsueh, W.-C. (2011) · SLEEP · doi:10.1093/sleep/34.5.661 · Cited by 53
Validating Accelerometry as a Measure of Physical Activity and Energy Expenditure in Chronic Stroke
Serra, M. C., Balraj, E., DiSanzo, B. L., Ivey, F. M., Hafer-Macko, C. E., Treuth, M. S., & Ryan, A. S. (2017) · Topics in Stroke Rehabilitation · doi:10.1080/10749357.2016.1183866 · Cited by 46
Persistent fatigue in hematopoietic stem cell transplantation survivors
Hacker, E. D., Fink, A. M., Peters, T., Park, C., Fantuzzi, G., & Rondelli, D. (2017) · Cancer Nursing · doi:10.1097/ncc.0000000000000405 · Cited by 37
“8) Gender, n (%) Male 14 (56) 14 (56) 28 (56) Female 11 (44) 11 (44) 22 (44) Race, n (%) African American 3 (12) 3 (6) Asian 1 (4) 1 (2) Hispanic 1 (4) 1 (2) White 22 (88) 20 (80) 42 (84) Not reported 3 (12) 3 (6) Education, n (%) Graduated from high school 1 (4) 1 (4) 2 (4) Some college 4 (16) 9 (36) 13 (26) Graduate…”
Shim, S., Kim, H., & Jung, J. (2014) · Journal of Physical Therapy Science · doi:10.1589/jpts.26.1009 · Cited by 37
Hall, P. A., Zehr, C., Paulitzki, J., & Rhodes, R. (2014) · Annals of Behavioral Medicine · doi:10.1007/s12160-013-9582-7 · Cited by 33
Effects of Body Mass Index and Tilt Angle on Output of Two Wearable Activity Monitors
FEITO, Y., BASSETT, D. R., TYO, B., & THOMPSON, D. L. (2011) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e3181fefd40 · Cited by 32
“Technical information regarding the two devices can be found elsewhere (4,5,7,24).”
A comparison of uniaxial and triaxial accelerometers for the assessment of physical activity in dogs
Cheung, K. W., Starling, M. J., & McGreevy, P. D. (2014) · Journal of Veterinary Behavior · doi:10.1016/j.jveb.2013.11.003 · Cited by 12
“The accelerometers have been validated in laboratory settings and on humans in everyday situations (Le-Masurier and TudorLocke, 2003; Esliger and Tremblay, 2006; Corder et al., 2007; Oliver et al., 2011).”
Background
Metadata
- Authors
- ESLIGER, D. W., & TREMBLAY, M. S.
- Venue
- Medicine & Science in Sports & Exercise
- Published
- 2006-12
- Volume
- 38
- Issue
- 12
- Pages
- 2173-2181
- ISSN
- 0195-9131 (ISSN-L)
- OpenAlex
- W2001323070
- Cited by
- 244
- References
- 4
- FWCI
- 5.69
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.