The DOI matches its Crossref record; 24 of the 24 references it cites were found in a registry or an index.
Associations of Cognitive Function Scores with Carbon Dioxide, Ventilation, and Volatile Organic Compound Exposures in Office Workers: A Controlled Exposure Study of Green and Conventional Office Environments
Open accessAbstract
Background: The indoor built environment plays a critical role in our overall well-being because of both the amount of time we spend indoors (~90%) and the ability of buildings to positively or negatively influence our health. The advent of sustainable design or green building strategies reinvigorated questions regarding the specific factors in buildings that lead to optimized conditions for health and productivity. Objective: We simulated indoor environmental quality (IEQ) conditions in “Green” and “Conventional” buildings and evaluated the impacts on an objective measure of human performance: higher-order cognitive function. Methods: Twenty-four participants spent 6 full work days (0900–1700 hours) in an environmentally controlled office space, blinded to test conditions. On different days, they were exposed to IEQ conditions representative of Conventional [high concentrations of volatile organic compounds (VOCs)] and Green (low concentrations of VOCs) office buildings in the United States. Additional conditions simulated a Green building with a high outdoor air ventilation rate (labeled Green+) and artificially elevated carbon dioxide (CO2) levels independent of ventilation. Results: On average, cognitive scores were 61% higher on the Green building day and 101% higher on the two Green+ building days than on the Conventional building day (p < 0.0001). VOCs and CO2 were independently associated with cognitive scores. Conclusions: Cognitive function scores were significantly better under Green+ building conditions than in the Conventional building conditions for all nine functional domains. These findings have wide-ranging implications because this study was designed to reflect conditions that are commonly encountered every day in many indoor environments. Citation: Allen JG, MacNaughton P, Satish U, Santanam S, Vallarino J, Spengler JD. 2016. Associations of cognitive function scores with carbon dioxide, ventilation, and volatile organic compound exposures in office workers: a controlled exposure study of green and conventional office environments. Environ Health Perspect 124:805–812; http://dx.doi.org/10.1289/ehp.1510037
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The cited source says what the claim attributes to it.
In the citing paper
“Low ventilation rates and CO2 concentrations normally found in office buildings (approximately 1,000 ppm) have been recently associated with impairment in multiple domains of high-order cognitive function [45,46].”
From Reduced cognitive function during a heat wave among residents of non-air-conditioned buildings: An observational study of young adults in the summer of 2016 (2018) · cites this paper as [46]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Ventilation for Acceptable Indoor Air Quality
Falih, M. (2019) · Cited by 2,497
Satish, U., Mendell, M. J., Shekhar, K., Hotchi, T., Sullivan, D., Streufert, S., & Fisk, W. J. (2012) · Environmental Health Perspectives · doi:10.1289/ehp.1104789 · Cited by 1,064 · cited 4×
“However, this conventional thinking is being challenged as the evidence mounts for CO2 as a direct pollutant, not just a marker for other pollutants (Satish et al. 2012).”
BackgroundMethodInfluentialSelf-citationWargocki, P. L., Wyon, D. P., Sundell, J., Clausen, G., & Fanger, P. O. (2000) · Indoor Air · doi:10.1034/j.1600-0668.2000.010004222.x · Cited by 693 · cited 1×
“…building factors, such as ventilation rate; workspace factors, such as the presence of chemical-emitting materials; and personal factors, such as job stress, allergies, and sex (Mendell 1993; Wargocki et al. 2000; Bornehag et al. 2005; Hedge 2009; Hedge and Gaygen 2010; Nishihara et al. 2014).”
Estimates of Improved Productivity and Health from Better Indoor Environments
Fisk, W. J., & Rosenfeld, A. H. (1997) · Indoor Air · doi:10.1111/j.1600-0668.1997.t01-1-00002.x · Cited by 551
Associations between classroom CO2 concentrations and student attendance in Washington and Idaho
Shendell, D. G., Prill, R., Fisk, W. J., Apte, M. G., Blake, D., & Faulkner, D. (2004) · Indoor Air · doi:10.1111/j.1600-0668.2004.00251.x · Cited by 462 · cited 1×
“Corsi et al. (2002) reported CO 2 concentrations > 1,000 ppm in 66% of 120 classrooms in Texas, and Shendell et al. (2004) measured CO 2 concentrations > 1,000 ppm in 45% of 435 classrooms in Washington and Idaho and reported that elevated CO 2 concentrations were associated with increases in…”
BackgroundEffects of Green Buildings on Employee Health and Productivity
Singh, A., Syal, M., Grady, S. C., & Korkmaz, S. (2010) · American Journal of Public Health · doi:10.2105/ajph.2009.180687 · Cited by 320
Non-Specific Symptoms In Office Workers: A Review And Summary Of The Epidemiologic Literature
Mendell, M. J. (1993) · Indoor Air · doi:10.1111/j.1600-0668.1993.00003.x · Cited by 282
Allen, J. G., MacNaughton, P., Laurent, J. G. C., Flanigan, S. S., Eitland, E. S., & Spengler, J. D. (2015) · Current Environmental Health Reports · doi:10.1007/s40572-015-0063-y · Cited by 281 · cited 1×
“To date, we know of no studies that have been conducted in green buildings where participants were blinded to their building condition (Allen et al. 2015).”
Self-citationPersily, A. (2015) · Building and Environment · doi:10.1016/j.buildenv.2015.02.026 · Cited by 249 · cited 2×
“The > 100-year story of ventilation in buildings is complicated and was neatly summarized recently by Persily (2015).”
Hodgson, A. T., Rudd, A., Beal, D., & Chandra, S. (2000) · Indoor Air · doi:10.1034/j.1600-0668.2000.010003178.x · Cited by 240
Flagged first, then by citations
Research works printed but not linked: 4
- ACGIH (American Conference of Governmental Industrial Hygienists), 2015, 2015 Guide to Occupational Exposure Values.
- Breuer K, Satish U, 2003, Emergency management simulations: an approach to the assessment of decision-making processes in complex dynamic crisis environments., 145
- Corsi RL, Torres VM, Sanders M, Kinney KA, 2002, Carbon dioxide levels and dynamics in elementary schools: results from the TESIAS study., 74
- Swezey, 1998, Preliminary development of a computer-based team performance assessment simulation., Int J Cogn Ergonomics, 2, 163
Cited by
Sorted by citations
Items 301–400 of 976
Human Circulatory/Respiratory‐Inspired Comprehensive Air Purification System
Jeong, S., Shin, J., Kim, J., Kim, H., Lee, J. G., Min, J., Hong, S., & Ko, S. H. (2024) · Advanced Materials · doi:10.1002/adma.202405568 · Cited by 19
Du, B., Reda, I., Licina, D., Kapsis, K., Qi, D., Candanedo, J. A., & Li, T. (2024) · Environmental Science & Technology · doi:10.1021/acs.est.4c02797 · Cited by 19
Xue, T., Kang, N., & Zhu, T. (2024) · Annual Review of Public Health · doi:10.1146/annurev-publhealth-071723-015722 · Cited by 20
Evaluation of relative weights for temperature, CO2, and noise in the aircraft cabin environment
Jia, S., Lai, D., Kang, J., Li, J., & Liu, J. (2018) · Building and Environment · doi:10.1016/j.buildenv.2018.01.009 · Cited by 19
Westermann, S., Niblock, S. J., & Kortt, M. A. (2018) · Journal of Asset Management · doi:10.1057/s41260-018-0079-6 · Cited by 19
“…flows and property market value as a result of a green premium on rents, higher tenant satisfaction and selling prices, and lower vacancy rates (Allen et al. 2015, 2016; Braun and Bienert 2015; CSDH 2008; Deng et al. 2012; Deng and Wu 2014; Devine and Kok 2015; Eichholtz et al. 2010, 2012,…”
BackgroundBharucha, Z. P., Weinstein, N., Watson, D. J., & Böhm, S. (2019) · Journal of Public Health · doi:10.1093/pubmed/fdz057 · Cited by 22
Chen, J., Augenbroe, G., Zeng, Z., & Song, X. (2020) · Building and Environment · doi:10.1016/j.buildenv.2020.106700 · Cited by 18
Longitudinal assessment of personal air pollution clouds in ten home and office environments
Serrano, V. G., & Licina, D. (2022) · Indoor Air · doi:10.1111/ina.12993 · Cited by 18
Duhirwe, P. N., Ngarambe, J., & Yun, G. Y. (2022) · Frontiers of Architectural Research · doi:10.1016/j.foar.2022.10.003 · Cited by 20
A longitudinal study of IAQ metrics and the efficacy of default HVAC ventilation
Varnosfaderani, M. P., Heydarian, A., & Jazizadeh, F. (2024) · Building and Environment · doi:10.1016/j.buildenv.2024.111353 · Cited by 18
The physical work environment and its relationship to stress
Sander, L., Caza, A., & Jordan, P. J. (2019) · Routledge eBooks · doi:10.4324/9781315167237-15 · Cited by 21
Interaction between plant species and substrate type in the removal of CO2 indoors
Gubb, C., Blanuša, T., Griffiths, A., & Pfrang, C. (2019) · Air Quality Atmosphere & Health · doi:10.1007/s11869-019-00736-2 · Cited by 18
Pantelic, J., Dawe, M., & Licina, D. (2019) · PLoS ONE · doi:10.1371/journal.pone.0223136 · Cited by 22
“Additionally, we can reasonably expect that wearing face masks affects productivity by obstructing normal operation within the building, reducing interaction with colleagues, degrading general comfort, and increasing CO2 inhalation which has been linked to cognitive function [33].”
BackgroundThe Possibility of Sustainable Urban Horticulture Based on Nature Therapy
Lü, N., Song, C., Kuronuma, T., Ikei, H., Miyazaki, Y., & Takagaki, M. (2020) · Sustainability · doi:10.3390/su12125058 · Cited by 21
“Research has found that CO2 and volatile organic compounds have direct and negative effects on human cognition and decision making [101].”
BackgroundInvestigation of natural aeration in home offices during the heating season – case study
Kalmár, T., & Kalmár, F. (2020) · Journal of Building Engineering · doi:10.1016/j.jobe.2020.102052 · Cited by 18
Krusaa, M. R., & Hviid, C. A. (2021) · Journal of Building Engineering · doi:10.1016/j.jobe.2021.102161 · Cited by 18
Shen, Y., Kwan, T. H., & Yang, H. (2022) · Applied Energy · doi:10.1016/j.apenergy.2022.118681 · Cited by 18
Awolesi, O., Ghafari, F., & Reams, M. (2025) · Energy and Built Environment · doi:10.1016/j.enbenv.2025.09.002 · Cited by 18
Pollard, B., Engelen, L., Held, F. P., Buskirk, J. V., Spinney, R. E., & de Dear, R. (2022) · Building and Environment · doi:10.1016/j.buildenv.2022.108812 · Cited by 18
An explanatory parametric model to predict comprehensive post-commissioning building performances
Li, P., Lu, Y., Qian, Y., Wang, Y., & Liang, W. (2022) · Building and Environment · doi:10.1016/j.buildenv.2022.108897 · Cited by 17
Abbas, S., Shah, M. I., Sinha, A., & Olohunlana, A. O. (2022) · Evaluation Review · doi:10.1177/0193841x221134850 · Cited by 17
“( Allen et al., 2016) found that compared to conventional buildings, green buildings, or low carbon of fi ces signi fi cantly increase the cognitive score of the people working.”
BackgroundCarroll, G. T., Kirschman, D. L., & Mammana, A. (2022) · Patient Safety in Surgery · doi:10.1186/s13037-022-00343-8 · Cited by 17
“[25] reported declines in “cognitive function scores” when indoor CO2 levels were increased from approximately 500 ppm to approximately 950 ppm, and greater declines when the CO2 level was raised to approximately 1400 ppm.”
BackgroundCrosscutting of the pollutants and building ventilation systems: a literature review
Zuazua-Ros, A., Andrade, L. D. B., Dorregaray-Oyaregui, S., Martín-Gómez, C., Ramos, J. C., Manzueta, R., Sáiz-Esquerra, B. S., & Ariño, A. H. (2023) · Environmental Science and Pollution Research · doi:10.1007/s11356-023-27148-1 · Cited by 17
“(2018), a CO2 concentration of about 1000 ppm could be taken as the maximum level indoor, and higher concentrations can lead to occupant sensibility and discomfort (Satish et al. 2012; Allen et al. 2016).”
BackgroundIndoor environment and brain health across the life course: A systematic review
Lu, J., Wu, J., & Chen, Y. (2024) · Building and Environment · doi:10.1016/j.buildenv.2024.112156 · Cited by 17
The Built Environment—A Missing “Cause of the Causes” of Non-Communicable Diseases
Walls, K., Boulic, M., & Boddy, J. (2016) · International Journal of Environmental Research and Public Health · doi:10.3390/ijerph13100956 · Cited by 17
“Indoor exposure to CO2 on workers can impair performance and decision-making [51] but this raises a number of questions for managing indoor air quality in offices, schools, airplanes, cars and homes.”
Energy taxes and economic growth in OECD countries: a simultaneous equations approach
Hassan, M., Oueslati, W., & Rousselière, D. (2021) · Journal of Environmental Economics and Policy · doi:10.1080/21606544.2021.1937326 · Cited by 17
“In a similar and more recent study, Allen et al. (2016) studied the association between the carbon dioxide and cognitive function scores. They used twenty-four participants that spent 6 full work days (9 am – 5 pm) in an environmentally controlled office space. The participants were been exposed artificially to differ…”
MethodResultImportance of environmental settings for the temporal dynamics of creativity
Daikoku, T., Fang, Q., Hamada, T., Handa, Y., & Nagai, Y. (2021) · Thinking Skills and Creativity · doi:10.1016/j.tsc.2021.100911 · Cited by 27
The cubicle deconstructed: Simple visual enclosure improves perseverance
Roberts, A. C., Yap, H. S., Kwok, K. W., Car, J., Soh, C. K., & Christopoulos, G. I. (2019) · Journal of Environmental Psychology · doi:10.1016/j.jenvp.2019.04.002 · Cited by 19
Bamrungwong, N., Vongmanee, V., & Rattanawong, W. (2020) · Sustainability · doi:10.3390/su12176994 · Cited by 16
Fernández-Agüera, J., Domínguez-Amarillo, S., Campano, M. Á., & Al-Khatri, H. (2022) · Air Quality Atmosphere & Health · doi:10.1007/s11869-022-01239-3 · Cited by 17
“Staying in a room with moderate-to-high CO2 concentrations may also affect cognitive processes and decision-making performance, and a degradation of multiple cognitive measures can be detected when CO2 values exceed 1000 ppm (Allen et al. 2016; Satish et al. 2012).”
BackgroundHerbig, B., Norrefeldt, V., Mayer, F., Reichherzer, A., Lei, F., & Wargocki, P. L. (2022) · Environmental Research · doi:10.1016/j.envres.2022.114770 · Cited by 16
Li, Z., Lu, J., Ruan, X., Wu, Y., Zhao, J., Jiao, X., Sun, J., & Sun, K. (2023) · Toxicology · doi:10.1016/j.tox.2023.153705 · Cited by 16
Qiao, Y., Gao, X., Liao, W., & Chen, D. (2024) · Journal of Building Engineering · doi:10.1016/j.jobe.2024.109325 · Cited by 16
Facing disaster: the great challenges framework
Torres, P. (2018) · foresight · doi:10.1108/fs-04-2018-0040 · Cited by 16
“…“moderate” declines in cognitive performance on decision tasks when the ambient concentration of CO2 increased from 600 to 1,000 ppm, and an “astonishingly large” drop in performance from 1,000 to 2,500 ppm (Grossman 2016; see also Romm 2014; Satish et al. 2012; Allen et al. 2016; Torres 2017a).”
BackgroundIndoor carbon dioxide metric analysis tool
Persily, A. K., & Polidoro, B. J. (2022) · doi:10.6028/nist.tn.2213 · Cited by 16
Guo, D., Zhan, C., Liu, J., Wang, Z., Cui, M., Zhang, X., Su, X., Pan, L., Deng, M., Zhao, L., et al. (2022) · Indoor Air · doi:10.1111/ina.13067 · Cited by 15
A Bibliographic Analysis of Indoor Air Quality (IAQ) in Industrial Environments
Lolli, F., Coruzzolo, A. M., Marinello, S., Traini, A., & Gamberini, R. (2022) · Sustainability · doi:10.3390/su141610108 · Cited by 15
Effect of low concentrations of indoor toluene on cognitive performance: EEG-based evidence
Wang, Z., Liu, J., Wang, J., Guo, D., Pei, J., Zhao, L., Zhang, X., Liu, J., Li, Y., Deng, M., et al. (2022) · Building and Environment · doi:10.1016/j.buildenv.2022.109494 · Cited by 15
Meta-Analysis of the Effect of Ventilation on Intellectual Productivity
Kuramochi, H., Tsurumi, R., & Ishibashi, Y. (2023) · International Journal of Environmental Research and Public Health · doi:10.3390/ijerph20085576 · Cited by 15
Air quality in the car: How CO2 and body odor affect drivers' cognition and driving performance?
Wang, C., Lin, Y., Ptukhin, Y., & Liu, S. (2023) · The Science of The Total Environment · doi:10.1016/j.scitotenv.2023.168785 · Cited by 15
A Method for Predicting Indoor CO2 Concentration in University Classrooms: An RF-TPE-LSTM Approach
Dai, Z., Yuan, Y., Zhu, X., & Zhao, L. (2024) · Applied Sciences · doi:10.3390/app14146188 · Cited by 20
Assessment of Interventions to Improve Air Quality in a Livestock Building
Anthony, T., Yang, A. Y.-J., & Peters, T. M. (2017) · Journal of Agricultural Safety and Health · doi:10.13031/jash.12426 · Cited by 15
“Significant declines in the cognitive ability of office workers were identified with CO 2 exposures in the range of 945 to 2500 ppm (Satish et al., 2012; Allen et al., 2016).”
Sánchez-Fernández, A., Aliaga, E. C., Lerma-Arce, V., & Lorenzo‐Sáez, E. (2023) · International Journal of Environmental Research and Public Health · doi:10.3390/ijerph20186757 · Cited by 15
Perception of Cabin Air Quality among Drivers and Passengers
Constantin, D., Mazilescu, C.-A., Nagi, M., Drăghici, A., & Mihartescu, A.-A. (2016) · Sustainability · doi:10.3390/su8090852 · Cited by 15
Monitoring of carbon dioxide (CO2) accumulation in vehicle cabin
Cheik, G. C., Kamarudin, L. M., Shukri, S., Abdullah, N. S., & Zakaria, A. (2016) · International Conference on Electronic Design · doi:10.1109/iced.2016.7804682 · Cited by 15
“From the research of National Institute of Environmental Health Sciences [8] stated that the high CO2 level could affect human cognition.”
BackgroundSnow, S., Boyson, A., Felipe-King, M., Malik, O., Coutts, L. V., Noakes, C. J., Gough, H., Barlow, J. F., & schraefel, M. C. (2018) · bioRxiv (Cold Spring Harbor Laboratory) · doi:10.1101/483750 · Cited by 16
Felgueiras, F., Mourão, Z. S., Moreira, A. M., & Gabriel, M. F. (2025) · Building and Environment · doi:10.1016/j.buildenv.2025.113320 · Cited by 14
Castro, I. A., Honea, H., Cornelis, E., & Majmundar, A. (2021) · International Journal of Research in Marketing · doi:10.1016/j.ijresmar.2021.09.007 · Cited by 14
Long-term filter efficiency of mobile air purifiers in schools
Granzin, M., Richter, S., Schrod, J., Schubert, N., & Curtius, J. (2022) · Aerosol Science and Technology · doi:10.1080/02786826.2022.2147414 · Cited by 16
“Despite the extraordinarily frequent venting during our experiments, the CO2 concentrations reached values above 1000 ppm several times throughout the day, which can cause loss in concentration, headaches and generally reduces the learning ability (Allen et al. 2016; Wargocki et al. 2020).”
BackgroundWen, Q., Liu, H., Chen, J., Ye, H., & Pan, Z. (2023) · International Journal of Environmental Research and Public Health · doi:10.3390/ijerph20054183 · Cited by 15
Prediction and Comparison of In-Vehicle CO2 Concentration Based on ARIMA and LSTM Models
Han, J., Lin, H., & Qin, Z. (2023) · Applied Sciences · doi:10.3390/app131910858 · Cited by 15
The effect of post-COVID-19 ventilation measures on indoor air quality in primary schools
Eichholtz, P. M. A., Kok, N., & Sun, X. (2023) · PNAS Nexus · doi:10.1093/pnasnexus/pgad429 · Cited by 14
“These studies have documented that im - provements in IAQ have a significant impact on the cognitive performance of test subjects in laboratory settings (7), on the quality of thinking in chess tournaments (8 ), and on the outcomes of various cognitive tests (9).”
BackgroundParticle and Gas-Phase Evaluation of Air Cleaners Under Indoor Wildfire Smoke Conditions
Stinson, B. W., Laguerre, A., & Gall, E. T. (2024) · ACS ES&T Air · doi:10.1021/acsestair.3c00083 · Cited by 16
A Systematic Review of the Vertical Green System for Balancing Ecology and Urbanity
Zhao, J., Rao, Q., Sun, C., Ikram, R. M. A., Fan, C., Li, J., Wang, M., & Zhang, D. (2024) · Water · doi:10.3390/w16111472 · Cited by 14
Williams, A., Schulte, K., & Varaden, D. (2024) · BMC Public Health · doi:10.1186/s12889-024-20635-1 · Cited by 18
Ellenburg, J., Williford, C. J., Rodriguez, S. L., Andersen, P. C., Turnipseed, A. A., Ennis, C. A., Basman, K. A., Hatz, J. M., Prince, J. C., Meyers, D. H., et al. (2019) · Atmospheric Environment X · doi:10.1016/j.aeaoa.2019.100048 · Cited by 14
Klausen, F. B., Amidi, A., Kjærgaard, S. K., Schlünssen, V., Ravn, P., Østergaard, K., Gutzke, V. H., Glasius, M., Grønborg, T. K., Hansen, S. N., et al. (2023) · International Journal of Occupational Medicine and Environmental Health · doi:10.13075/ijomeh.1896.02032 · Cited by 13
Indoor CO2 removal: decentralized carbon capture by air conditioning
Tian, H., Zhu, L., Ni, J., Wei, T., Wang, P., Xiao, H., & Chen, X. (2023) · Materials Today Sustainability · doi:10.1016/j.mtsust.2023.100369 · Cited by 15
Gurrani, S., Prakasham, K., Huang, P., Wu, M., Wu, C., Lin, Y.-C., Tsai, B., Krishnan, A., Tsai, P., & Ponnusamy, V. K. (2023) · Chemosphere · doi:10.1016/j.chemosphere.2023.138667 · Cited by 13
Wang, D., Wang, H., Qu, M., Ma, Y., Wang, K., Jia, S., Yu, C., & Zhang, S. (2023) · Environmental Monitoring and Assessment · doi:10.1007/s10661-023-11439-8 · Cited by 13
“…activities such as energy development have led to rising global environmental problems such as greenhouse effects, global climate change (Hayami et al., 2005; Klemeš & Pierucci, 2008; Wang et al., 2014), and human security (Allen et al., 2016; Cromar et al., 2021; Karnauskas et al., 2020).”
BackgroundTheoretical Threshold for Estimating the Impact of Ventilation on Materials’ Emissions
Domhagen, F., Langer, S., & Kalagasidis, A. S. (2024) · Environmental Science & Technology · doi:10.1021/acs.est.3c09815 · Cited by 13
Bie, H., Guo, B., Li, T., & Loftness, V. (2025) · Energy and Buildings · doi:10.1016/j.enbuild.2025.115389 · Cited by 13
Evaluation of the thermal comfort in different commercial buildings in Guangzhou
Mao, Y., Zhu, K., Zheng, Z., & Fang, Z. (2023) · Indoor and Built Environment · doi:10.1177/1420326x231199639 · Cited by 13
Schütze, A., & Sauerwald, T. (2019) · Elsevier eBooks · doi:10.1016/b978-0-12-814827-3.00011-6 · Cited by 13
Xia, Y., Shikii, S., & Shimomura, Y. (2020) · Ergonomics · doi:10.1080/00140139.2020.1784466 · Cited by 13
Grygierek, K., & Ferdyn-Grygierek, J. (2022) · Energies · doi:10.3390/en15228456 · Cited by 12
Commercial real estate and air pollution
Cvijanović, D., Rolheiser, L., & de Minne, A. V. (2024) · Real Estate Economics · doi:10.1111/1540-6229.12484 · Cited by 12
Zhang, Z., Zhang, Q., Xi, Y., Zhou, Y. F., & Zhan, M. (2024) · Journal of Chromatography A · doi:10.1016/j.chroma.2024.464863 · Cited by 12
Zhao, Z., Huebner, G., Bagkeris, E., & Mumovic, D. (2025) · The Science of The Total Environment · doi:10.1016/j.scitotenv.2025.178652 · Cited by 14
“This finding contrasts with those from other studies that either involved longer exposure durations or different VOC sources (which might contain more irritating compounds) (Allen et al., 2016; Gao et al., 2022).”
InfluentialMota, A., Serôdio, C., Briga-Sá, A., & Valente, A. L. G. (2025) · Sensors · doi:10.3390/s25061683 · Cited by 12
“These symptoms correlate with hypercapnia, which is when the brain receives CO 2 -rich blood and its function is affected [1,3,9].”
On the Ventilation Performance of Low Momentum Confluent Jets Supply Device in a Classroom
Andersson, H., Kabanshi, A., Cehlin, M., & Moshfegh, B. (2020) · Energies · doi:10.3390/en13205415 · Cited by 12
Yu, Y., Wang, B., You, S., Ye, T., Zheng, W., Wei, S., Yang, S. L., Wang, Y., & Li, K. (2021) · Air Quality Atmosphere & Health · doi:10.1007/s11869-021-01074-y · Cited by 12
“In buildings, CO2 concentration is closely linked with occupants’ physi‐ ological responses (Allen et al. 2016; Zhang et al. 2016), and high CO2 concentration greatly reduces both cognitive per‐ formance and learning efficiency (Kenichi et al.”
BackgroundWyrwoll, C. S., Papini, M. G., Chivers, E. K., Yuan, J., Pavlos, N. J., Lucas, R. M., Bierwirth, P. N., & Larcombe, A. N. (2021) · The Journal of Physiology · doi:10.1113/jp282179 · Cited by 12
“Exposure to CO2 levels of 950–2000 ppm (compared to 600 ppm) for periods of 2.5–8 h was associated with reduced cognitive function scores (Satish et al. 2012; Allen et al. 2016).”
BackgroundInfluentialMaheshwari, A. K., Werd, M. R. P., Travis, F. T., Rainforth, M. V., & Lipman, J. (2021) · Journal of Management Spirituality & Religion · doi:10.51327/kyon6624 · Cited by 12
Cross, J. E., Shelley, T. O., & Mayer, A. (2017) · Energy Research & Social Science · doi:10.1016/j.erss.2017.06.020 · Cited by 12
Fan, G., Xie, J., & Liu, J. (2017) · Procedia Engineering · doi:10.1016/j.proeng.2017.10.377 · Cited by 12
Exposure to Particulate Matter and CO2 in indoor conditions at IIT(ISM) Dhanbad
Kumar, S., & Jain, M. K. (2021) · Materials Today Proceedings · doi:10.1016/j.matpr.2021.04.496 · Cited by 12
Designing for Health: How the Physical Environment Plays a Role in Workplace Wellness
Timm, S., Gray, W. A., Curtis, T., & Chung, S. S. E. (2018) · American Journal of Health Promotion · doi:10.1177/0890117118779463b · Cited by 12
“Improvements to indoor air quality (specifically reductions in CO2 levels) have been shown to improve cognitive function in laboratory studies.(16) Reducing nighttime use of traditional artificial light has the potential to help prevent possible carcinogenic effects associated with melatonin supression.”
BackgroundA Review of Cognitive and Behavioral Effects of Increased Carbon Dioxide Exposure in Humans
Stanković, A., Alexander, D. J., Oman, C. M., & Schneiderman, J. S. (2016) · Cited by 11
Zhang, D., Zhang, L., & Zhang, Y. (2024) · Journal of Building Engineering · doi:10.1016/j.jobe.2024.109422 · Cited by 11
A Field Survey on Indoor Climate in Land Transport Cabins of Buses and Trains
Ogundiran, J. O., Nyembwe, J.-P. K. B., Ribeiro, A. S. N., & da Silva, M. (2024) · Atmosphere · doi:10.3390/atmos15050589 · Cited by 11
A novel dataset of indoor environmental conditions in work-from-home settings
Manu, S., & Rysanek, A. (2024) · Building and Environment · doi:10.1016/j.buildenv.2024.112222 · Cited by 11
A Survey on Sensor-Based Techniques for Continuous Stress Monitoring in Knowledge Work Environments
Kallio, J., Vildjiounaite, E., Tervonen, J., & López, M. B. (2025) · ACM Transactions on Computing for Healthcare · doi:10.1145/3720551 · Cited by 14
Forecasting of safe-green buildings using decision tree algorithm: data mining approach
Motaghifard, A., Omidvari, M., & Kazemi, A. (2022) · Environment Development and Sustainability · doi:10.1007/s10668-022-02491-4 · Cited by 11
“Abbaszadeh and Allen researched indoor air quality (Abbaszadeh et al., 2006; Allen et al., 2015), while Colton and Zhang and Altan reviewed the health of residents in the building (Colton et al., 2015; Zhang & Altan, 2011).”
BackgroundTemporal Variations Dataset for Indoor Environmental Parameters in Northern Saudi Arabia
Alshammari, T. A., Ramadan, R. Α., & Ahmad, A. (2023) · Applied Sciences · doi:10.3390/app13127326 · Cited by 11
Faubel, C., Martínez-Molina, A., & Suk, J. Y. (2023) · Journal of Building Engineering · doi:10.1016/j.jobe.2023.108289 · Cited by 12
Quach, T., Behren, J. V., Nelson, D. O., Nguyen, T. N., Tsoh, J. Y., Le, M., Fu, L. W., Beckman, S., & Reynolds, P. (2018) · American Journal of Industrial Medicine · doi:10.1002/ajim.22897 · Cited by 11
Health and Wellbeing in Modern Office Layouts: The Case of Agile Workspaces in Green Buildings
Laughton, K.-A., & Thatcher, A. (2018) · Advances in intelligent systems and computing · doi:10.1007/978-3-319-96068-5_89 · Cited by 11
Chemical space mapping for multicomponent gas mixtures
Kotliar-Shapirov, A., Fedorov, F. S., Ouerdane, H., Evlashin, S. A., Nasibulin, A. G., & Stevenson, K. J. (2021) · Journal of Electroanalytical Chemistry · doi:10.1016/j.jelechem.2021.115472 · Cited by 11
Indoor Coal Combustion for Heating Exacerbates CO2 Exposure Approaching Harmful Levels
Li, Y., Liu, X., Men, Y., Luo, Z., Xiong, R., Li, J., Cheng, H., Tao, S., & Shen, G. (2021) · Environmental Science & Technology Letters · doi:10.1021/acs.estlett.1c00650 · Cited by 11
How will window opening change under global warming: A study for China residence
Liu, Y., Liu, S., Wang, S., & Zhao, B. (2021) · Building and Environment · doi:10.1016/j.buildenv.2021.108672 · Cited by 11
Implementation of the IDAIC framework on an air handling unit to transition to proactive maintenance
Ahern, M., O’Sullivan, D. T. J., & Bruton, K. (2023) · Energy and Buildings · doi:10.1016/j.enbuild.2023.112872 · Cited by 11
Brain Fog: Does Air Pollution Make Us Less Productive?
Schmidt, S. (2019) · Environmental Health Perspectives · doi:10.1289/ehp4869 · Cited by 11
Membrane system for management and utilization of indoor CO2
Yoo, S. Y., Kim, Y. J., Lee, T. H., Lee, B. K., Kim, M. J., Han, S. H., Ha, S. Y., & Park, H. B. (2023) · Journal of Industrial and Engineering Chemistry · doi:10.1016/j.jiec.2023.02.018 · Cited by 10
Xie, Z., Wang, Q., Zhou, K., Ma, L., Wang, J., Li, Y., Chen, S., & Wei, W. (2024) · Indoor Air · doi:10.1155/2024/5781565 · Cited by 10
Duill, F. F., Schulz, F., Jain, A., Paucke, N., Wachem, B. G. M. V., & Beyrau, F. (2024) · Building and Environment · doi:10.1016/j.buildenv.2024.112484 · Cited by 10
Carbon dioxide as a pollutant: the risks on human health and the stability of the biosphere
Bardi, U., Bierwirth, P. N., Huang, K., & McIntyre, J. (2025) · Environmental Science Advances · doi:10.1039/d5va00017c · Cited by 17
Chronopoulos, S. K., Kosma, E. I., Tafiadis, D., Dimopoulos, D., Raptis, V., Karvounis, E. C., Angelidis, P. A., & Kostarakis, P. (2017) · Communications and Network · doi:10.4236/cn.2018.101002 · Cited by 10
Spiropyran-based chromic hydrogels for CO2 absorption and detection
Marco, A., Guirado, G., Sebastián, R. M., & Hernando, J. C. (2023) · Frontiers in Chemistry · doi:10.3389/fchem.2023.1176661 · Cited by 10
“, 2004) and work health and safety (Allen et al., 2016).”
BackgroundZand, M. S., Spallina, S., Ross, A., Zandi, K., Pawlowski, A., Seplaki, C. L., Herington, J., Corbett, A. M., Kaukeinen, K. A., Holden‐Wiltse, J., et al. (2024) · PLoS ONE · doi:10.1371/journal.pone.0291840 · Cited by 10
“One building had HVAC systems”
Metadata
- Authors
- Allen, J. G., MacNaughton, P., Satish, U., Santanam, S., Vallarino, J., & Spengler, J. D.
- Affiliations
- Harvard University (US)
- SUNY Upstate Medical University (US)
- Syracuse University (US)
- Corresponding author
- Allen, Joseph G.
- Venue
- Environmental Health Perspectives
- Publisher
- American Chemical Society (ACS)
- Published
- 2015-10-26
- Volume
- 124
- Issue
- 6
- Pages
- 805-812
- ISSN
- 0091-6765 (ISSN-L)
- 1552-9924
- PMC
- PMC4892924
- OpenAlex
- W2412131385
- Cited by
- 977
- References
- 24
- Citations by year
- 2026: 138 · 2025: 121 · 2024: 121 · 2023: 88 · 2022: 103 · 2021: 107 · 2020: 86 · 2019: 84 · 2018: 66 · 2017: 36 · 2016: 25 · 2015: 1
- FWCI
- 26.76
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Licence
- public-domain
- creativecommons.org/licenses/by/4.0/ (vor, 795 d)
- Locations
- Environmental Health Perspectives (publishedVersion, public-domain)
- PubMed Central (publishedVersion, public-domain)
- PubMed (publishedVersion)
- Digital Access to Scholarship at Harvard (DASH) (Harvard University) (submittedVersion, cc-by)
- Funders
- Harvard T.H. Chan School of Public Health
- National Institute of Environmental Health Sciences (T32ES007069)
- Topics
- Physical Sciences › Environmental Science › Health, Toxicology and Mutagenesis › Indoor Air Quality and Microbial Exposure
- Physical Sciences › Engineering › Architecture › Facilities and Workplace Management
- Physical Sciences › Engineering › Building and Construction › Sustainable Building Design and Assessment
- Keywords
- cognitive function, carbon dioxide exposure, indoor ventilation, volatile organic compounds, sustainable construction, indoor environmental quality, office workers, higher-order cognition
- MeSH terms
- Air Pollutants, Occupational, Carbon Dioxide, Cognition, Humans, United States, Ventilation, Occupational Exposure, Air Pollution, Indoor, Volatile Organic Compounds
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review