The DOI matches its Crossref record; 62 of the 62 references it cites were found in a registry or an index.
Diffraction phase microscopy: principles and applications in materials and life sciences
Abstract
The main obstacle in retrieving quantitative phase with high sensitivity is posed by the phase noise due to mechanical vibrations and air fluctuations that typically affect any interferometric system. In this paper, we review diffraction phase microscopy (DPM), which is a common-path quantitative phase imaging (QPI) method that significantly alleviates the noise problem. DPM utilizes a compact Mach–Zehnder interferometer to combine several attributes of current QPI methods. This compact configuration inherently cancels out most mechanisms responsible for noise and is single-shot, meaning that the acquisition speed is limited only by the speed of the camera employed. This technique is also nondestructive and does not require staining or coating of the specimen. This unique collection of features enables the DPM system to accurately monitor the dynamics of various nanoscale phenomena in a wide variety of environments. The DPM system can operate in both transmission and reflection modes in order to accommodate both transparent and opaque samples, respectively. Thus, current applications of DPM include measuring the dynamics of biological samples, semiconductor wet etching and photochemical etching processes, surface wetting and evaporation of water droplets, self-assembly of nanotubes, expansion and deformation of materials, and semiconductor wafer defect detection. Finally, DPM with white light averages out much of the speckle background and also offers potential for spectroscopic measurements.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Габор, Д. (1946) · Journal of the IEE · Cited by 5,036
GABOR, D. (1948) · Nature · doi:10.1038/161777a0 · Cited by 4,548
Fourier-transform method of fringe-pattern analysis for computer-based topography and interferometry
Takeda, M., Ina, H., & Kobayashi, S. (1982) · Journal of the Optical Society of America · doi:10.1364/josa.72.000156 · Cited by 4,277
Beiträge zur Theorie des Mikroskops und der mikroskopischen Wahrnehmung
Abbe, E. (1873) · Archiv für Mikroskopische Anatomie · doi:10.1007/bf02956173 · Cited by 2,724
Phase-shifting digital holography
Yamaguchi, I., & Zhang, T. (1997) · Optics Letters · doi:10.1364/ol.22.001268 · Cited by 2,061
Hoshen, J., & Kopelman, R. (1976) · Physical Review B · doi:10.1103/physrevb.14.3438 · Cited by 1,928
The pathogenic basis of malaria
Miller, L. H., Baruch, D. I., Marsh, K., & Doumbo, O. K. (2002) · Nature · doi:10.1038/415673a · Cited by 1,746
Developing optofluidic technology through the fusion of microfluidics and optics
Psaltis, D., Quake, S. R., & Yang, C. (2006) · Nature · doi:10.1038/nature05060 · Cited by 1,733
Reconstructed Wavefronts and Communication Theory*
Leith, E. N., & Upatnieks, J. (1962) · Journal of the Optical Society of America · doi:10.1364/josa.52.001123 · Cited by 1,658
Marquet, P., Rappaz, B., Magistretti, P. J., Cuche, E., Emery, Y., Colomb, T., & Depeursinge, C. (2005) · Optics Letters · doi:10.1364/ol.30.000468 · Cited by 1,254
DIGITAL IMAGE FORMATION FROM ELECTRONICALLY DETECTED HOLOGRAMS
Goodman, J. W., & Lawrence, R. W. (1967) · Applied Physics Letters · doi:10.1063/1.1755043 · Cited by 1,148
Red cell membrane: past, present, and future
Mohandas, N., & Gallagher, P. G. (2008) · Blood · doi:10.1182/blood-2008-07-161166 · Cited by 1,089
Phase contrast, a new method for the microscopic observation of transparent objects
Zernike, F. (1942) · Physica · doi:10.1016/s0031-8914(42)80035-x · Cited by 1,068
Cell and molecular mechanics of biological materials
Bao, G., & Suresh, S. (2003) · Nature Materials · doi:10.1038/nmat1001 · Cited by 1,055
Etch rates for micromachining processing-part II
Williams, K. R., Gupta, K., & Wasilik, M. (2003) · Journal of Microelectromechanical Systems · doi:10.1109/jmems.2003.820936 · Cited by 1,027
Suresh, S., Spatz, J., Mills, J. P., Micoulet, A., Dao, M., Lim, C. T., Beil, M., & Seufferlein, T. (2005) · Acta Biomaterialia · doi:10.1016/j.actbio.2004.09.001 · Cited by 878
Park, Y., Diez-Silva, M., Popescu, G., Lykotrafitis, G., Choi, W., Feld, M. S., & Suresh, S. (2008) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0806100105 · Cited by 689
Self-citationRappaz, B., Marquet, P., Cuche, E., Emery, Y., Depeursinge, C., & Magistretti, P. J. (2005) · Optics Express · doi:10.1364/opex.13.009361 · Cited by 674
High-resolution quantitative phase-contrast microscopy by digital holography
Mann, C. J., Yu, L., Lo, C.-M., & Kim, M. K. (2005) · Optics Express · doi:10.1364/opex.13.008693 · Cited by 663
Frequency spectrum of the flicker phenomenon in erythrocytes
Brochard‐Wyart, F., & Jf, L. (1975) · Journal de physique · doi:10.1051/jphys:0197500360110103500 · Cited by 658
Biochemistry of Plasmodium (malarial parasites)
Sherman, I. W. (1979) · Microbiological Reviews · doi:10.1128/mmbr.43.4.453-495.1979 · Cited by 639
Cell refractive index tomography by digital holographic microscopy
Charrière, F., Marian, A., Montfort, F., Kuehn, J., Colomb, T., Cuche, E., Marquet, P., & Depeursinge, C. (2006) · Optics Letters · doi:10.1364/ol.31.000178 · Cited by 561
Lim H. W., G., Wortis, M., & Mukhopadhyay, R. (2002) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.202617299 · Cited by 520
Optical imaging of cell mass and growth dynamics
Popescu, G., Park, Y., Lue, N., Best-Popescu, C., Deflores, L., Dasari, R. R., Feld, M. S., & Badizadegan, K. (2008) · American Journal of Physiology-Cell Physiology · doi:10.1152/ajpcell.00121.2008 · Cited by 518
Self-citationLee, K., Kim, K., Jung, J., Heo, J., Cho, S., Lee, S., Chang, G., Jo, Y., Park, H., & Park, Y. (2013) · Sensors · doi:10.3390/s130404170 · Cited by 510
Goldberg, D. E., Slater, A. F., Cerami, A., & Henderson, G. B. (1990) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.87.8.2931 · Cited by 485
Lensfree microscopy on a cellphone
Tseng, D., Mudanyali, O., Oztoprak, C., Isikman, S. O., Sencan, I., Yaglidere, O., & Ozcan, A. (2010) · Lab on a Chip · doi:10.1039/c003477k · Cited by 480
Pulling a single chromatin fiber reveals the forces that maintain its higher-order structure
Cui, Y., & Bustamante, C. (2000) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.97.1.127 · Cited by 471
Fourier phase microscopy for investigation of biological structures and dynamics
Popescu, G., DeFlores, L. P., Vaughan, J. C., Badizadegan, K., Iwai, H., Dasari, R. R., & Feld, M. S. (2004) · Optics Letters · doi:10.1364/ol.29.002503 · Cited by 450
Self-citationInterference Microscopy and Mass Determination
BARER, R. (1952) · Nature · doi:10.1038/169366b0 · Cited by 433
Spectrin-Level Modeling of the Cytoskeleton and Optical Tweezers Stretching of the Erythrocyte
Li, J., Dao, M., Lim, C. T., & Suresh, S. (2005) · Biophysical Journal · doi:10.1529/biophysj.104.047332 · Cited by 426
Linear-time connected-component labeling based on sequential local operations
Suzuki, K., Horiba, I., & Sugie, N. (2003) · Computer Vision and Image Understanding · doi:10.1016/s1077-3142(02)00030-9 · Cited by 414
Forced Unfolding of Proteins Within Cells
Johnson, C. P., Tang, H.-Y., Carag, C., Speicher, D. W., & Discher, D. E. (2007) · Science · doi:10.1126/science.1139857 · Cited by 377
Phase contrast, a new method for the microscopic observation of transparent objects part II
Zernike, F. (1942) · Physica · doi:10.1016/s0031-8914(42)80079-8 · Cited by 377
Investigation of living pancreas tumor cells by digital holographic microscopy
Kemper, B., Carl, D., Schnekenburger, J., Bredebusch, I., Schäfer, M., Domschke, W., & von Bally, G. (2006) · Journal of Biomedical Optics · doi:10.1117/1.2204609 · Cited by 364
Molecular Maps of Red Cell Deformation: Hidden Elasticity and in Situ Connectivity
Discher, D. E., Mohandas, N., & Evans, E. A. (1994) · Science · doi:10.1126/science.7973655 · Cited by 355
Lateral mobility of integral membrane proteins is increased in spherocytic erythrocytes
Sheetz, M. P., Schindler, M., & Koppel, D. E. (1980) · Nature · doi:10.1038/285510a0 · Cited by 322
Red Blood Cell Membrane Fluctuations and Shape Controlled by ATP-Induced Cytoskeletal Defects
Gov, N. S., & Safran, S. A. (2005) · Biophysical Journal · doi:10.1529/biophysj.104.045328 · Cited by 305
Diffraction phase microscopy with white light
Bhaduri, B., Pham, H., Mir, M., & Popescu, G. (2012) · Optics Letters · doi:10.1364/ol.37.001094 · Cited by 304
Self-citationPlasmodium falciparum Maturation Abolishes Physiologic Red Cell Deformability
Cranston, H. A., Boylan, C. W., Carroll, G. L., Sutera, S. P., Williamson, J. R., Gluzman, I. Y., & Krogstad, D. J. (1984) · Science · doi:10.1126/science.6362007 · Cited by 301
Dynamics of shear-induced ATP release from red blood cells
Wan, J., Ristenpart, W. D., & Stone, H. A. (2008) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0805779105 · Cited by 279
Kilejian, A. (1979) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.76.9.4650 · Cited by 243
Viscoelasticity of the human red blood cell
Puig-de-Morales-Marinkovic, M., Turner, K. T., Butler, J. P., Fredberg, J. J., & Suresh, S. (2007) · American Journal of Physiology-Cell Physiology · doi:10.1152/ajpcell.00562.2006 · Cited by 243
Optical Measurement of Cell Membrane Tension
Popescu, G., Ikeda, T., Goda, K., Best-Popescu, C. A., Laposata, M., Manley, S., Dasari, R. R., Badizadegan, K., & Feld, M. S. (2006) · Physical Review Letters · doi:10.1103/physrevlett.97.218101 · Cited by 223
Self-citationInterference Microscopy and Mass Determination
DAVIES, H. G., & WILKINS, M. H. F. (1952) · Nature · doi:10.1038/169541a0 · Cited by 209
Cytoskeleton Confinement and Tension of Red Blood Cell Membranes
Gov, N., Zilman, A. G., & Safran, S. (2003) · Physical Review Letters · doi:10.1103/physrevlett.90.228101 · Cited by 189
Rappaz, B., Charrière, F., Depeursinge, C., Magistretti, P. J., & Marquet, P. (2008) · Optics Letters · doi:10.1364/ol.33.000744 · Cited by 183
Phase imaging of cells by simultaneous dual-wavelength reflection digital holography
Khmaladze, A., Kim, M., & Lo, C.-M. (2008) · Optics Express · doi:10.1364/oe.16.010900 · Cited by 161
Hwang, C. J. (1969) · Journal of Applied Physics · doi:10.1063/1.1658263 · Cited by 160
Applications of digital and analog holography in three-dimensional imaging
Nehmetallah, G., & Banerjee, P. P. (2012) · Advances in Optics and Photonics · doi:10.1364/aop.4.000472 · Cited by 158
Shaked, N. T., Satterwhite, L. L., Truskey, G. A., Wax, A. P., & Telen, M. J. (2011) · Journal of Biomedical Optics · doi:10.1117/1.3556717 · Cited by 152
Viscoelastic properties of erythrocyte membranes in high-frequency electric fields
Engelhardt, H., Gaub, H. E., & Sackmann, E. (1984) · Nature · doi:10.1038/307378a0 · Cited by 142
Existence of a Flat Phase in Red Cell Membrane Skeletons
Schmidt, C. F., Svoboda, K., Lei, N., Petsche, I. B., Berman, L. E., Safinya, C. R., & Grest, G. S. (1993) · Science · doi:10.1126/science.8438153 · Cited by 132
Hemoglobin degradation in the malaria parasite : an ordered process in a unique organelle
Goldberg, D. E. (1990) · Medical Entomology and Zoology · Cited by 122
Quantitative phase spectroscopy
Rinehart, M. T., Zhu, Y., & Wax, A. P. (2012) · Biomedical Optics Express · doi:10.1364/boe.3.000958 · Cited by 114
Detecting 20 nm Wide Defects in Large Area Nanopatterns Using Optical Interferometric Microscopy
Zhou, R., Edwards, C., Arbabi, A., et al. (2013) · Nano Letters · doi:10.1021/nl401622b · Cited by 112
Self-citationReal-Time Digital Holographic Microscopy for Phase Contrast 3D Imaging of Dynamic Phenomena
Anand, A., Chhaniwal, V. K., & Javidi, B. (2010) · Journal of Display Technology · doi:10.1109/jdt.2010.2052020 · Cited by 100
Dynamic DIC by digital holography microscopy for enhancing phase-contrast visualization
Miccio, L., Fińizio, A., Puglisi, R., Balduzzi, D., Galli, A., & Ferraro, P. (2011) · Biomedical Optics Express · doi:10.1364/boe.2.000331 · Cited by 75
Coherence properties of red blood cell membrane motions
Popescu, G., Park, Y., Dasari, R. R., Badizadegan, K., & Feld, M. S. (2007) · Physical Review E · doi:10.1103/physreve.76.031902 · Cited by 71
Self-citationFournier, J., Lacoste, D., & Raphaël, É. (2004) · Physical Review Letters · doi:10.1103/physrevlett.92.018102 · Cited by 66
Curl, C. L., Bellair, C. J., Harris, P. J. F., Allman, B. E., Roberts, A., Nugent, K. A., & Delbridge, L. M. D. (2004) · Clinical and Experimental Pharmacology and Physiology · doi:10.1111/j.1440-1681.2004.04100.x · Cited by 61
Weinstein, R. S., Graham, A. R., Lian, F., Braunhut, B. L., Barker, G. P., Krupinski, E. A., & Bhattacharyya, A. K. (2012) · Apmis · doi:10.1111/j.1600-0463.2011.02866.x · Cited by 58
Cited by
Superpixel-based spatial amplitude and phase modulation using a digital micromirror device
Goorden, S. A., Bertolotti, J., & Mosk, A. P. (2014) · Optics Express · doi:10.1364/oe.22.017999 · Cited by 356
Quantitative Phase Imaging: Recent Advances and Expanding Potential in Biomedicine
Nguyen, T. L., Pradeep, S., Judson-Torres, R. L., Reed, J., Teitell, M. A., & Zangle, T. A. (2022) · ACS Nano · doi:10.1021/acsnano.1c11507 · Cited by 318
Self-citationQuantitative phase imaging based on holography: trends and new perspectives
Huang, Z., & Cao, L. (2024) · Light: Science & Applications · doi:10.1038/s41377-024-01453-x · Cited by 277
Gradient light interference microscopy for 3D imaging of unlabeled specimens
Nguyen, T. H., Kandel, M. E., Rubessa, M., Wheeler, M. B., & Popescu, G. (2017) · Nature Communications · doi:10.1038/s41467-017-00190-7 · Cited by 259
Self-citation
Metadata
- Authors
- Bhaduri, B., Edwards, C., Pham, H., Zhou, R., Nguyen, T. H., Goddard, L. L., & Popescu, G.
- Venue
- Advances in Optics and Photonics
- Publisher
- Optica Publishing Group
- Published
- 2014-03-26
- Volume
- 6
- Issue
- 1
- Pages
- 57
- ISSN
- 1943-8206 (ISSN-L)
- OpenAlex
- W2004908285
- Cited by
- 425
- References
- 62
- FWCI
- 17.64
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.