Estimation of Daily Energy Expenditure in Pregnant and Non-Pregnant Women Using a Wrist-Worn Tri-Axial Accelerometer
Open accessThe DOI matches its Crossref record; 36 of the 36 references it cites were found in a registry or an index.
Abstract
BACKGROUND: Few studies have compared the validity of objective measures of physical activity energy expenditure (PAEE) in pregnant and non-pregnant women. PAEE is commonly estimated with accelerometers attached to the hip or waist, but little is known about the validity and participant acceptability of wrist attachment. The objectives of the current study were to assess the validity of a simple summary measure derived from a wrist-worn accelerometer (GENEA, Unilever Discover, UK) to estimate PAEE in pregnant and non-pregnant women, and to evaluate participant acceptability. METHODS: Non-pregnant (N = 73) and pregnant (N = 35) Swedish women (aged 20-35 yrs) wore the accelerometer on their wrist for 10 days during which total energy expenditure (TEE) was assessed using doubly-labelled water. PAEE was calculated as 0.9×TEE-REE. British participants (N = 99; aged 22-65 yrs) wore accelerometers on their non-dominant wrist and hip for seven days and were asked to score the acceptability of monitor placement (scored 1 [least] through 10 [most] acceptable). RESULTS: There was no significant correlation between body weight and PAEE. In non-pregnant women, acceleration explained 24% of the variation in PAEE, which decreased to 19% in leave-one-out cross-validation. In pregnant women, acceleration explained 11% of the variation in PAEE, which was not significant in leave-one-out cross-validation. Median (IQR) acceptability of wrist and hip placement was 9(8-10) and 9(7-10), respectively; there was a within-individual difference of 0.47 (p<.001). CONCLUSIONS: A simple summary measure derived from a wrist-worn tri-axial accelerometer adds significantly to the prediction of energy expenditure in non-pregnant women and is scored acceptable by participants.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
(1965) · The Lancet · doi:10.1016/s0140-6736(65)91037-8 · Cited by 16,856
Prince, S. A., Adamo, K. B., Hamel, M., Hardt, J., Connor Gorber, S., & Tremblay, M. (2008) · International Journal of Behavioral Nutrition and Physical Activity · doi:10.1186/1479-5868-5-56 · Cited by 3,162
The thrifty phenotype hypothesis
Hales, C. N., & Barker, D. J. P. (2001) · British Medical Bulletin · doi:10.1093/bmb/60.1.5 · Cited by 2,738
Conducting accelerometer-based activity assessments in field-based research
TROST, S. G., MCIVER, K. L., & PATE, R. R. (2005) · Medicine & Science in Sports & Exercise · doi:10.1249/01.mss.0000185657.86065.98 · Cited by 2,033
The Effect of Social Desirability and Social Approval on Self-Reports of Physical Activity
Adams, S. A. (2005) · American Journal of Epidemiology · doi:10.1093/aje/kwi054 · Cited by 1,160 · cited 1×
“Nonetheless, the current findings in non-pregnant women are comparable to the accuracy reported for accelerometer positioned on the hip or lower back [9,32–34].”
The Technology of Accelerometry-Based Activity Monitors: Current and Future
CHEN, K. Y., & BASSETT, D. R. (2005) · Medicine & Science in Sports & Exercise · doi:10.1249/01.mss.0000185571.49104.82 · Cited by 996
Self-citationPhysical Activity Assessment With Accelerometers: An Evaluation Against Doubly Labeled Water
Plasqui, G., & Westerterp, K. R. (2007) · Obesity · doi:10.1038/oby.2007.281 · Cited by 654
Estimation of gait cycle characteristics by trunk accelerometry
Moe-Nilssen, R., & Helbostad, J. L. (2004) · Journal of Biomechanics · doi:10.1016/s0021-9290(03)00233-1 · Cited by 640
Validation of the GENEA Accelerometer
ESLIGER, D. W., ROWLANDS, A. V., HURST, T. L., CATT, M., MURRAY, P., & ESTON, R. G. (2011) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e31820513be · Cited by 625 · cited 2×
“The accelerometer (GENEA, Unilever Discover, Sharnbrook Bedfordshire, UK) comprised a tri-axial STMicroelectronics accelerometer (LIS3LV02DL) with a dynamic range of 6 6 g (1 g= 9.81 m ? s 2 2 ), as described elsewhere [13].”
InfluentialSelf-citation
Cited by
Doherty, A., Jackson, D., Hammerla, N., Plötz, T., Olivier, P., Granat, M. H., White, T., van Hees, V. T., Trenell, M. I., Owen, C. G., et al. (2017) · PLOS ONE · doi:10.1371/journal.pone.0169649 · Cited by 1,250
Self-citationAge Group Comparability of Raw Accelerometer Output from Wrist- and Hip-Worn Monitors
HILDEBRAND, M., VAN HEES, V. T., HANSEN, B. H., & EKELUND, U. (2014) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0000000000000289 · Cited by 1,043
Self-citationMigueles, J. H., Rowlands, A. V., Huber, F., Sabia, S., & van Hees, V. T. (2019) · Journal for the Measurement of Physical Behaviour · doi:10.1123/jmpb.2018-0063 · Cited by 955
van Hees, V. T., Gorzelniak, L., Dean León, E. C., Eder, M., Pias, M., Taherian, S., Ekelund, U., Renström, F., Franks, P. W., Horsch, A., et al. (2013) · PLoS ONE · doi:10.1371/journal.pone.0061691 · Cited by 926
Self-citationA novel, open access method to assess sleep duration using a wrist-worn accelerometer
van Hees, V. T., Sabia, S., Anderson, K. N., Denton, S. J., Oliver, J., Catt, M., Abell, J. G., Kivimäki, M., Trenell, M. I., & Singh-Manoux, A. (2015) · PLOS ONE · doi:10.1371/journal.pone.0142533 · Cited by 744
Self-citationFerguson, T., Rowlands, A. V., Olds, T., & Maher, C. (2015) · International Journal of Behavioral Nutrition and Physical Activity · doi:10.1186/s12966-015-0201-9 · Cited by 468
Calibration of the GENEA accelerometer for assessment of physical activity intensity in children
Phillips, L. R. S., Parfitt, G., & Rowlands, A. V. (2013) · Journal of Science and Medicine in Sport · doi:10.1016/j.jsams.2012.05.013 · Cited by 322
Daily physical activity assessment with accelerometers: new insights and validation studies
Plasqui, G., Bonomi, A. G., & Westerterp, K. R. (2013) · Obesity Reviews · doi:10.1111/obr.12021 · Cited by 315
Sabia, S., van Hees, V. T., Shipley, M. J., Trenell, M. I., Hagger-Johnson, G., Elbaz, A., Kivimaki, M., & Singh-Manoux, A. (2014) · American Journal of Epidemiology · doi:10.1093/aje/kwt330 · Cited by 304
Wear Compliance and Activity in Children Wearing Wrist- and Hip-Mounted Accelerometers
FAIRCLOUGH, S. J., NOONAN, R., ROWLANDS, A. V., VAN HEES, V., KNOWLES, Z., & BODDY, L. M. (2016) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0000000000000771 · Cited by 300
Self-citationValidity of activity monitors in health and chronic disease: a systematic review
Van Remoortel, H., Giavedoni, S., Raste, Y., Burtin, C., Louvaris, Z., Gimeno-Santos, E., Langer, D., Glendenning, A., Hopkinson, N. S., Vogiatzis, I., et al. (2012) · International Journal of Behavioral Nutrition and Physical Activity · doi:10.1186/1479-5868-9-84 · Cited by 277
Chandler, J. L., Brazendale, K., Beets, M. W., & Mealing, B. A. (2016) · Pediatric Obesity · doi:10.1111/ijpo.12033 · Cited by 275
Self-affirmation alters the brain’s response to health messages and subsequent behavior change.
Falk, E. B., O’Donnell, M. B., Cascio, C. N., Tinney, F., Kang, Y., Lieberman, M. D., Taylor, S. E., An, L., Resnicow, K., & Strecher, V. J. (2015) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1500247112 · Cited by 190
Accelerometer-assessed Physical Activity in Epidemiology: Are Monitors Equivalent?
ROWLANDS, A. V., MIRKES, E. M., YATES, T., CLEMES, S., DAVIES, M., KHUNTI, K., & EDWARDSON, C. L. (2018) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0000000000001435 · Cited by 187
“Critically, the GGIR accelerometer processing package used in this study (17, 18, 19) can be easily applied to large datasets and is available open-source, as is the function we created to convert Axivity raw files to a format that can be analysed in GGIR.”
Application of data fusion techniques and technologies for wearable health monitoring
King, R. C., Villeneuve, E., White, R. J., Sherratt, R. S., Holderbaum, W., & Harwin, W. S. (2017) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2016.12.011 · Cited by 182
“[13] to investigate the estimation of daily energy expenditure using a wrist-worn accelerometer, the acceptability of wearing the device on the hip or wrist was also examined.”
Hip and Wrist Accelerometer Algorithms for Free-Living Behavior Classification
ELLIS, K., KERR, J., GODBOLE, S., STAUDENMAYER, J., & LANCKRIET, G. (2016) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0000000000000840 · Cited by 186
White, T., Westgate, K., Wareham, N. J., & Brage, S. (2016) · PLOS ONE · doi:10.1371/journal.pone.0167472 · Cited by 169
Self-citationWijsman, C. A., Westendorp, R. G., Verhagen, E. A., Catt, M., Slagboom, P. E., de Craen, A. J., Broekhuizen, K., van Mechelen, W., van Heemst, D., van der Ouderaa, F., et al. (2013) · Journal of Medical Internet Research · doi:10.2196/jmir.2843 · Cited by 156
“The GENEActiv wrist accelerometer provides a simple summary statistic of total activity counts has been validated for measuring daily physical activity against doubly labeled water [19].”
Self-citationRowlands, A. V. (2018) · Pediatric Exercise Science · doi:10.1123/pes.2018-0201 · Cited by 87
O'Brien, J. T., Gallagher, P., Stow, D., Hammerla, N., Ploetz, T., Firbank, M., Ladha, C., Ladha, K., Jackson, D., McNaney, R., et al. (2017) · Psychological Medicine · doi:10.1017/s0033291716002166 · Cited by 76
“Wear-time was estimated using the approach described in van Hees et al. (2011), where each 30 min segment of recording is classi fi ed as ‘ wear-time ’ if the standard deviation of the acceleration magnitude exceeds a fi xed threshold of 13 m g ( g = 9.81 m/s 2 ).”
InfluentialKim, Y., White, T., Wijndaele, K., Sharp, S. J., Wareham, N. J., & Brage, S. (2017) · International Journal of Obesity · doi:10.1038/ijo.2017.122 · Cited by 66
Self-citationWearable accelerometer-derived physical activity and incident disease
Khurshid, S., Weng, L.-C., Nauffal, V., Pirruccello, J. P., Venn, R. A., Al-Alusi, M. A., Benjamin, E. J., Ellinor, P. T., & Lubitz, S. A. (2022) · npj Digital Medicine · doi:10.1038/s41746-022-00676-9 · Cited by 63
Wrist-worn accelerometers in assessment of energy expenditure during intensive training
Kinnunen, H., Tanskanen, M., Kyröläinen, H., & Westerterp, K. R. (2012) · Physiological Measurement · doi:10.1088/0967-3334/33/11/1841 · Cited by 53
Segmenting accelerometer data from daily life with unsupervised machine learning
van Kuppevelt, D., Heywood, J., Hamer, M., Sabia, S., Fitzsimons, E., & van Hees, V. (2019) · PLOS ONE · doi:10.1371/journal.pone.0208692 · Cited by 41
Self-citationSegmenting accelerometer data from daily life with unsupervised machine learning
van Kuppevelt, D., Heywood, J., Hamer, M., Sabia, S., Fitzsimons, E., & van Hees, V. (2018) · doi:10.1101/263046 · Cited by 41
Self-citationValidation of the Fitbit One® for physical activity measurement at an upper torso attachment site
Diaz, K. M., Krupka, D. J., Chang, M. J., Shaffer, J. A., Ma, Y., Goldsmith, J., Schwartz, J. E., & Davidson, K. W. (2016) · BMC Research Notes · doi:10.1186/s13104-016-2020-8 · Cited by 29
Liang, Y. Y., He, Y., Huang, P., Feng, H., Li, H., Ai, S., Du, J., Xue, H., Liu, Y., Zhang, J., et al. (2025) · Journal of Sport and Health Science · doi:10.1016/j.jshs.2024.100973 · Cited by 25
Brand, Y. E., Kluge, F., Palmerini, L., Paraschiv-Ionescu, A., Becker, C., Cereatti, A., Maetzler, W., Sharrack, B., Vereijken, B., Yarnall, A. J., et al. (2024) · Scientific Reports · doi:10.1038/s41598-024-71491-3 · Cited by 19
Slyepchenko, A., Uher, R., Ho, K., Hassel, S., Matthews, C., Lukus, P. K., Daros, A. R., Minarik, A., Placenza, F., Li, Q. S., et al. (2023) · Scientific Reports · doi:10.1038/s41598-023-42138-6 · Cited by 17
Metadata
- Authors
- van Hees, V. T., Renström, F., Wright, A., Gradmark, A., Catt, M., Chen, K. Y., Löf, M., Bluck, L., Pomeroy, J., Wareham, N. J., Ekelund, U., Brage, S., & Franks, P. W.
- Venue
- PLoS ONE
- Publisher
- Public Library of Science (PLoS)
- Published
- 2011-07-29
- Volume
- 6
- Issue
- 7
- Pages
- e22922
- ISSN
- 1932-6203 (ISSN-L)
- OpenAlex
- W2109270820
- Cited by
- 289
- References
- 36
- FWCI
- 5.39
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.