A Novel, Open Access Method to Assess Sleep Duration Using a Wrist-Worn Accelerometer
Open accessThe DOI matches its Crossref record; 39 of the 39 references it cites were found in a registry or an index.
Abstract
Wrist-worn accelerometers are increasingly being used for the assessment of physical activity in population studies, but little is known about their value for sleep assessment. We developed a novel method of assessing sleep duration using data from 4,094 Whitehall II Study (United Kingdom, 2012-2013) participants aged 60-83 who wore the accelerometer for 9 consecutive days, filled in a sleep log and reported sleep duration via questionnaire. Our sleep detection algorithm defined (nocturnal) sleep as a period of sustained inactivity, itself detected as the absence of change in arm angle greater than 5 degrees for 5 minutes or more, during a period recorded as sleep by the participant in their sleep log. The resulting estimate of sleep duration had a moderate (but similar to previous findings) agreement with questionnaire based measures for time in bed, defined as the difference between sleep onset and waking time (kappa = 0.32, 95%CI:0.29,0.34) and total sleep duration (kappa = 0.39, 0.36,0.42). This estimate was lower for time in bed for women, depressed participants, those reporting more insomnia symptoms, and on weekend days. No such group differences were found for total sleep duration. Our algorithm was validated against data from a polysomnography study on 28 persons which found a longer time window and lower angle threshold to have better sensitivity to wakefulness, while the reverse was true for sensitivity to sleep. The novelty of our method is the use of a generic algorithm that will allow comparison between studies rather than a "count" based, device specific method.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Figures
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“Physical activity and sleep were objectively measured over 7 days by use of wristworn triaxial accelerometers; data were assessed with validated calibration and analysis algorithms.13,14”
From Primary care-led weight management for remission of type 2 diabetes (DiRECT): an open-label, cluster-randomised trial (2018) · cites this paper as [13]
Experimental — accuracy not yet measured
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Weighted kappa: nominal scale agreement provision for scaled disagreement or partial credit
Cohen, J. (1968) · Psychological Bulletin · doi:10.1037/h0026256 · Cited by 8,736 · cited 1×
“The agreement between weekly average accelerometer assessed sleep duration (time in bed, and total sleep duration − rounded to the nearest integer) and self-reported sleep duration from the health survey questionnaire was assessed using a confusion matrix and a weighted Cohen’s Kappa coefficient [27].”
MethodPhysical Activity in the United States Measured by Accelerometer
TROIANO, R. P., BERRIGAN, D., DODD, K. W., MÂSSE, L. C., TILERT, T., & MCDOWELL, M. (2008) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e31815a51b3 · Cited by 7,638 · cited 1×
“Studies of physical activity use a hip- or waist-mounted accelerometer that are not suitable for sleep assessment as they are removed prior to bedtime [1].”
Background(2007) · Cited by 6,530
Health inequalities among British civil servants: the Whitehall II study
Marmot, M. G., Stansfeld, S., Patel, C., North, F., Head, J., White, I., Brunner, E., Feeney, A., Marmot, M. G., & Smith, G. D. (1991) · The Lancet · doi:10.1016/0140-6736(91)93068-k · Cited by 3,608
Automatic Sleep/Wake Identification From Wrist Activity
Cole, R. J., Kripke, D. F., Gruen, W., Mullaney, D. J., & Gillin, J. C. (1992) · Sleep · doi:10.1093/sleep/15.5.461 · Cited by 1,941 · cited 2×
“Previously published methods for sleep detection using accelerometers optimized their parameters to best fit with polysomnography-derived periods of sleep [14,18].”
MethodActivity-Based Sleep-Wake Identification: An Empirical Test of Methodological Issues
Sadeh, A., Sharkey, M., & Carskadon, M. A. (1994) · Sleep · doi:10.1093/sleep/17.3.201 · Cited by 1,487 · cited 1×
“Previous work on sleep detection from accelerometer data relied on algorithms that use magnitude of acceleration as their input [13,18,19].”
MethodA scale for the estimation of sleep problems in clinical research
Jenkins, C. D., Stanton, B.-A., Niemcryk, S. J., & Rose, R. M. (1988) · Journal of Clinical Epidemiology · doi:10.1016/0895-4356(88)90138-2 · Cited by 1,203 · cited 1×
“• Insomnia symptoms derived from the Jenkins Sleep Problem Scale [24].”
MethodAge Group Comparability of Raw Accelerometer Output from Wrist- and Hip-Worn Monitors
HILDEBRAND, M., VAN HEES, V. T., HANSEN, B. H., & EKELUND, U. (2014) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0000000000000289 · Cited by 1,043
van Hees, V. T., Gorzelniak, L., Dean León, E. C., Eder, M., Pias, M., Taherian, S., Ekelund, U., Renström, F., Franks, P. W., Horsch, A., et al. (2013) · PLoS ONE · doi:10.1371/journal.pone.0061691 · Cited by 926
The Role of Actigraphy in the Evaluation of Sleep Disorders
Sadeh, A., Hauri, P. J., Kripke, D. F., & Lavie, P. (1995) · Sleep · doi:10.1093/sleep/18.4.288 · Cited by 909
Cited by
Lean, M. E., Leslie, W. S., Barnes, A. C., Brosnahan, N., Thom, G., McCombie, L., Peters, C., Zhyzhneuskaya, S., Al-Mrabeh, A., Hollingsworth, K. G., et al. (2018) · The Lancet · doi:10.1016/s0140-6736(17)33102-1 · Cited by 2,095
Self-citationMigueles, J. H., Rowlands, A. V., Huber, F., Sabia, S., & van Hees, V. T. (2019) · Journal for the Measurement of Physical Behaviour · doi:10.1123/jmpb.2018-0063 · Cited by 955
“…mistakes in sleep diary data g.part4 provides the option to visualize the differences between accelerometer-based estimates and sleep diary; this was for example used in van Hees et al. (van Hees et al., 2015) to identify a dozen of problematic nights out of 27000 nights (Figure 2, panel a).”
MethodSelf-citationJones, S. E., Lane, J. M., Wood, A. R., van Hees, V. T., Tyrrell, J., Beaumont, R. N., Jeffries, A. R., Dashti, H. S., Hillsdon, M., Ruth, K. S., et al. (2019) · Nature Communications · doi:10.1038/s41467-018-08259-7 · Cited by 691
Association of sleep duration in middle and old age with incidence of dementia
Sabia, S., Fayosse, A., Dumurgier, J., van Hees, V. T., Paquet, C., Sommerlad, A., Kivimäki, M., Dugravot, A., & Singh-Manoux, A. (2021) · Nature Communications · doi:10.1038/s41467-021-22354-2 · Cited by 628
Self-citationDashti, H. S., Jones, S. E., Wood, A. R., Lane, J. M., van Hees, V. T., Wang, H., Rhodes, J. A., Song, Y., Patel, K., Anderson, S. G., et al. (2019) · Nature Communications · doi:10.1038/s41467-019-08917-4 · Cited by 609
Estimating sleep parameters using an accelerometer without sleep diary
van Hees, V. T., Sabia, S., Jones, S. E., Wood, A. R., Anderson, K. N., Kivimäki, M., Frayling, T. M., Pack, A. I., Bucan, M., Trenell, M. I., et al. (2018) · Scientific Reports · doi:10.1038/s41598-018-31266-z · Cited by 554
Self-citationGWAS identifies 14 loci for device-measured physical activity and sleep duration
Doherty, A., Smith-Byrne, K., Ferreira, T., Holmes, M. V., Holmes, C., Pulit, S. L., & Lindgren, C. M. (2018) · Nature Communications · doi:10.1038/s41467-018-07743-4 · Cited by 408
Biological and clinical insights from genetics of insomnia symptoms
Sleep, H. A. I., Lane, J. M., Jones, S. E., Dashti, H. S., Wood, A. R., Aragam, K. G., van Hees, V. T., Strand, L. B., Winsvold, B. S., Wang, H., et al. (2019) · Nature Genetics · doi:10.1038/s41588-019-0361-7 · Cited by 397
Genetic studies of accelerometer-based sleep measures yield new insights into human sleep behaviour
Jones, S. E., van Hees, V. T., Mazzotti, D. R., Marques-Vidal, P., Sabia, S., van der Spek, A., Dashti, H. S., Engmann, J., Kocevska, D., Tyrrell, J., et al. (2019) · Nature Communications · doi:10.1038/s41467-019-09576-1 · Cited by 300
Self-citationde Zambotti, M., Goldstein, C., Cook, J., Menghini, L., Altini, M., Cheng, P., & Robillard, R. (2024) · SLEEP · doi:10.1093/sleep/zsad325 · Cited by 250
“Machine learning analysis of data acquired with contemporary research/clinical-grade devices provides a novel methodology that may be superior to original algorithms to quantify sleep from raw acceleration data [73] and may even identify off-wrist time [74].”
Willetts, M., Hollowell, S., Aslett, L., Holmes, C., & Doherty, A. (2018) · Scientific Reports · doi:10.1038/s41598-018-26174-1 · Cited by 250
“To extract sleep information, participants were asked to complete a simple sleep diary, as used in the Whitehall study, which consisted of two questions 46 : ‘ what time did you first fall asleep last night?”
MethodWang, H., Lane, J. M., Jones, S. E., Dashti, H. S., Ollila, H. M., Wood, A. R., van Hees, V. T., Brumpton, B., Winsvold, B. S., Kantojärvi, K., et al. (2019) · Nature Communications · doi:10.1038/s41467-019-11456-7 · Cited by 237
How consumer physical activity monitors could transform human physiology research
Wright, S. P., Hall Brown, T. S., Collier, S. R., & Sandberg, K. (2017) · American Journal of Physiology-Regulatory, Integrative and Comparative Physiology · doi:10.1152/ajpregu.00349.2016 · Cited by 234
Difrancesco, S., Lamers, F., Riese, H., Merikangas, K. R., Beekman, A. T. F., Hemert, A. M., Schoevers, R. A., & Penninx, B. W. J. H. (2019) · Depression and Anxiety · doi:10.1002/da.22949 · Cited by 214
Measuring sleep regularity: theoretical properties and practical usage of existing metrics
Fischer, D., Klerman, E. B., & Phillips, A. J. K. (2021) · Sleep · doi:10.1093/sleep/zsab103 · Cited by 204
The Promise of Sleep: A Multi-Sensor Approach for Accurate Sleep Stage Detection Using the Oura Ring
Altini, M., & Kinnunen, H. (2021) · Sensors · doi:10.3390/s21134302 · Cited by 193
“Third, the difference in arm angle was calculated in 5-s epochs [35], and then aggregated in 30-s epochs using the trimmed mean, max, and IQR.”
MethodFairclough, S. J., Dumuid, D., Taylor, S., Curry, W., McGrane, B., Stratton, G., Maher, C., & Olds, T. (2017) · International Journal of Behavioral Nutrition and Physical Activity · doi:10.1186/s12966-017-0521-z · Cited by 167
“Furthermore, the ST/LPA threshold was not informed by a measure of postural allocation, and sleep time was based on sustained inactivity bouts within a predefined angular range of arm motion [39] rather than using polysomnography.”
MethodMenai, M., van Hees, V. T., Elbaz, A., Kivimaki, M., Singh-Manoux, A., & Sabia, S. (2017) · Scientific Reports · doi:10.1038/srep45772 · Cited by 159
Self-citationMigueles, J. H., Aadland, E., Andersen, L. B., Brønd, J. C., Chastin, S. F., Hansen, B. H., Konstabel, K., Kvalheim, O. M., McGregor, D. E., Rowlands, A. V., et al. (2022) · British Journal of Sports Medicine · doi:10.1136/bjsports-2020-103604 · Cited by 145
Self-citationNavigating through the r packages for movement
Joo, R., Boone, M., Clay, T. A., Patrick, S. C., Clusella‐Trullas, S., & Basille, M. (2019) · Journal of Animal Ecology · doi:10.1111/1365-2656.13116 · Cited by 170
Montoye, A. H. K., Moore, R. W., Bowles, H. R., Korycinski, R. W., & Pfeiffer, K. A. (2016) · British Journal of Sports Medicine · doi:10.1136/bjsports-2015-095947 · Cited by 154
Raw Accelerometer Data Analysis with GGIR R-package: Does Accelerometer Brand Matter?
ROWLANDS, A. V., YATES, T., DAVIES, M., KHUNTI, K., & EDWARDSON, C. L. (2016) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0000000000000978 · Cited by 137
“Two commercially 54 available research grade wrist-worn accelerometers that are widely used globally are the 55 GENEActiv and the ActiGraph (5, 10, 18, 21).”
BackgroundMethodAlonso-Martínez, A. M., Ramírez‐Vélez, R., García‐Alonso, Y., Izquierdo, M., & García‐Hermoso, A. (2021) · International Journal of Environmental Research and Public Health · doi:10.3390/ijerph18020693 · Cited by 148
“[16] sleep algorithm was used to detect sleep and wake between self-reported bedtime and get uptime.”
MethodMigueles, J. H., Cadenas‐Sanchez, C., Tudor‐Locke, C., Löf, M., Esteban‐Cornejo, I., Molina‐Garcia, P., Mora‐Gonzalez, J., Rodriguez‐Ayllon, M., Garcia‐Marmol, E., Ekelund, U., et al. (2019) · Scandinavian Journal of Medicine & Science in Sports · doi:10.1111/sms.13356 · Cited by 123
Testing Self-Report Time-Use Diaries against Objective Instruments in Real Time
Gershuny, J., Harms, T., Doherty, A., Thomas, E., Milton, K., Kelly, P., & Foster, C. (2020) · Sociological Methodology · doi:10.1177/0081175019884591 · Cited by 124
Sleep and circadian rhythm disturbance in bipolar disorder
Bradley, A. J., Webb-Mitchell, R., Hazu, A., Slater, N., Middleton, B., Gallagher, P., McAllister-Williams, H., & Anderson, K. N. (2017) · Psychological Medicine · doi:10.1017/s0033291717000186 · Cited by 119
“The raw accelerometer data was analysed using an open source R package sleep detection algorithm, GGIR, that has already demonstrated a high sensitivity and specificity to detect periods of sleep (van Hees et al. 2015).”
MethodSelf-citationNon-wear or sleep? Evaluation of five non-wear detection algorithms for raw accelerometer data
Ahmadi, M. N., Nathan, N., Sutherland, R., Wolfenden, L., & Trost, S. G. (2020) · Journal of Sports Sciences · doi:10.1080/02640414.2019.1703301 · Cited by 113
“The fi rst algorithm (VH_30/80), developed by Van Hees et al. (van Hees et al., 2013, 2011), identi fi ed non-wear periods using the standard deviation (SD) and range of the acceleration signal along the x, y, and z axes recorded for 60-minute windows, with a 45-minute overlap.”
MethodSleep classification from wrist-worn accelerometer data using random forests
Sundararajan, K., Georgievska, S., te Lindert, B. H. W., Gehrman, P. R., Ramautar, J., Mazzotti, D. R., Sabia, S., Weedon, M. N., van Someren, E. J. W., Ridder, L., et al. (2021) · Scientific Reports · doi:10.1038/s41598-020-79217-x · Cited by 106
Self-citationEdwardson, C. L., Biddle, S. J. H., Clemes, S. A., Davies, M. J., Dunstan, D. W., Eborall, H., Granat, M. H., Gray, L. J., Healy, G. N., Jaicim, N. B., et al. (2022) · BMJ · doi:10.1136/bmj-2021-069288 · Cited by 97
Sabia, S., Dugravot, A., Léger, D., Ben Hassen, C., Kivimaki, M., & Singh-Manoux, A. (2022) · PLOS Medicine · doi:10.1371/journal.pmed.1004109 · Cited by 106
“Sleep duration was estimated using a validated algorithm guided by a sleep log [26]; data from the first and last nights were removed leading to data over 7 nights.”
MethodSelf-citationMcDonough, D. J., Helgeson, M. A., Liu, W., & Gao, Z. (2021) · Journal of sport and health science/Journal of Sport and Health Science · doi:10.1016/j.jshs.2021.07.009 · Cited by 117
“For detection of participants’ sleep quality, we used GGIR to estimate change(s) in arm angle relative to the horizontal plane while sleeping, with a change in arm angle of <5 ̊ over a 5-min period considered as a possible sleep period.(51) We calculated the following sleep variables: sleep duration (h/ night) and sle…”
Burchartz, A., Anedda, B., Auerswald, T., Giurgiu, M., Hill, H., Ketelhut, S., Kolb, S., Mall, C., Manz, K., Nigg, C. R., et al. (2020) · Psychology of sport and exercise · doi:10.1016/j.psychsport.2020.101703 · Cited by 110
Exercise training improves sleep quality: A randomized controlled trial
Jurado‐Fasoli, L., De‐la‐O, A., Molina‐Hidalgo, C., Migueles, J. H., Castillo, M. J., & Amaro‐Gahete, F. J. (2020) · European Journal of Clinical Investigation · doi:10.1111/eci.13202 · Cited by 107
Sensors Capabilities, Performance, and Use of Consumer Sleep Technology
de Zambotti, M., Cellini, N., Menghini, L., Sarlo, M., & Baker, F. C. (2020) · Sleep Medicine Clinics · doi:10.1016/j.jsmc.2019.11.003 · Cited by 82
Wearable Devices: Current Status and Opportunities in Pain Assessment and Management
Leroux, A., Lynn, R. R., Crainiceanu, C., & Sharma, T. (2021) · Digital Biomarkers · doi:10.1159/000515576 · Cited by 104
Cepeda, M., Koolhaas, C. M., van Rooij, F. J. A., Tiemeier, H. W., Guxens, M., Franco, O. H., & Schoufour, J. D. (2018) · Maturitas · doi:10.1016/j.maturitas.2018.01.016 · Cited by 109
40 years of actigraphy in sleep medicine and current state of the art algorithms
Patterson, M. R., Nunes, A. A. S., Gerstel, D., Pilkar, R., Guthrie, T., Neishabouri, A., & Guo, C. C. (2023) · npj Digital Medicine · doi:10.1038/s41746-023-00802-1 · Cited by 91
“For the van Hees et al. 2015 algorithm, a python implementation of the algorithm described in the paper was used14.”
MethodPhelan, S., Wing, R. R., Brannen, A., McHugh, A., Hagobian, T. A., Schaffner, A., Jelalian, E., Hart, C. N., Scholl, T. O., Munoz-Christian, K., et al. (2018) · The American Journal of Clinical Nutrition · doi:10.1093/ajcn/nqx043 · Cited by 83
“Time spent sleeping was estimated by using an algorithm that defined sleep as the absence of change in arm angle >5° for ≥5 min (37).”
MethodStathi, A., Greaves, C. J., Thompson, J. L., Withall, J., Ladlow, P., Taylor, G., Medina-Lara, A., Snowsill, T., Gray, S., Green, C., et al. (2022) · The Lancet Public Health · doi:10.1016/s2468-2667(22)00004-4 · Cited by 113
Benson, J. A., McSorley, V. E., Hawkley, L. C., & Lauderdale, D. S. (2020) · SLEEP · doi:10.1093/sleep/zsaa140 · Cited by 93
“With the advantage of being able to assess sleep over several nights without affecting behavior, actigraphy has recently been added to a number of large population-based studies, such as Whitehall II and the UK Biobank [14, 15].”
Rowlands, A. V. (2018) · Pediatric Exercise Science · doi:10.1123/pes.2018-0201 · Cited by 87
Environment shapes sleep patterns in a wild nocturnal primate
Reinhardt, K. D., Vyazovskiy, V. V., Hernandez-Aguilar, R. A., Imron, M. A., & Nekaris, K. A. I. (2019) · Scientific Reports · doi:10.1038/s41598-019-45852-2 · Cited by 89
Chen, B., Bernard, J. Y., Padmapriya, N., Yao, J., Goh, C. M. J. L., Tan, K. H., Yap, F. K. P., Chong, Y. S., Shek, L. P., Godfrey, K. M., et al. (2019) · International Journal of Behavioral Nutrition and Physical Activity · doi:10.1186/s12966-019-0834-1 · Cited by 90
Migueles, J. H., Cadenas-Sanchez, C., Rowlands, A. V., Henriksson, P., Shiroma, E. J., Acosta, F. M., Rodriguez-Ayllon, M., Esteban-Cornejo, I., Plaza-Florido, A., Gil-Cosano, J. J., et al. (2019) · Scientific Reports · doi:10.1038/s41598-019-54267-y · Cited by 77
pyActigraphy: Open-source python package for actigraphy data visualization and analysis
Hammad, G. H., Reyt, M., Beliy, N., Baillet, M., Deantoni, M., Lesoinne, A., Muto, V., & Schmidt, C. (2021) · PLoS Computational Biology · doi:10.1371/journal.pcbi.1009514 · Cited by 89
Duncan, M., Fenton, S., Brown, W., Collins, C., Glozier, N., Kolt, G., Holliday, E., Morgan, P., Murawski, B., Plotnikoff, R., et al. (2020) · International Journal of Environmental Research and Public Health · doi:10.3390/ijerph17176200 · Cited by 78
Migueles, J. H., Cadenas‐Sánchez, C., Lubans, D. R., Henriksson, P., Torres‐Lopez, L. V., Rodríguez‐Ayllón, M., Plaza‐Florido, A., Gil-Cosano, J. J., Henriksson, H., Escolano-Margarit, M. V., et al. (2023) · JAMA Network Open · doi:10.1001/jamanetworkopen.2023.24839 · Cited by 84
Metabolic effects of bezafibrate in mitochondrial disease
Steele, H., Gomez‐Duran, A., Pyle, A., Hopton, S., Newman, J., Stefanetti, R. J., Charman, S. J., Parikh, J. D., He, L., Viscomi, C., et al. (2020) · EMBO Molecular Medicine · doi:10.15252/emmm.201911589 · Cited by 82
Harrington, D. M., Davies, M. J., Bodicoat, D. H., Charles, J. M., Chudasama, Y. V., Gorely, T., Khunti, K., Plekhanova, T., Rowlands, A. V., Sherar, L. B., et al. (2018) · International Journal of Behavioral Nutrition and Physical Activity · doi:10.1186/s12966-018-0664-6 · Cited by 74
“Sedentary time was partitioned out from sleep using the nocturnal sleep detection algorithm in GGIR [23].”
MethodSleep Deprivation Deteriorates Heart Rate Variability and Photoplethysmography
Bourdillon, N., Jeanneret, F., Nilchian, M., Albertoni, P., Ha, P., & Millet, G. P. (2021) · Frontiers in Neuroscience · doi:10.3389/fnins.2021.642548 · Cited by 85
“These algorithms are Frontiers in Neuroscience | www.frontiersin.org 4 April 2021 | Volume 15 | Article 642548 based on the magnitude of accelerations (Borazio et al., 2014) and changes of arm angle (van Hees et al., 2015).”
BackgroundMontoye, A. H. K., Begum, M., Henning, Z., & Pfeiffer, K. A. (2017) · Physiological Measurement · doi:10.1088/1361-6579/38/2/343 · Cited by 84
Gubelmann, C., Heinzer, R. C., Haba‐Rubio, J., Vollenweider, P., & Marques-Vidal, P. M. (2018) · SLEEP · doi:10.1093/sleep/zsy070 · Cited by 77
“Today, light and wearable accelerometers allow an easy and objective assessment of PA and SB [18], as well as sleep estimation [19].”
Sleep regularity and mortality: a prospective analysis in the UK Biobank
Cribb, L., Sha, R., Yiallourou, S. R., Grima, N., Cavuoto, M. G., Baril, A., & Pase, M. P. (2023) · eLife · doi:10.7554/elife.88359 · Cited by 75
Watson, A., Dumuid, D., Maher, C. A., & Olds, T. (2021) · Journal of sport and health science/Journal of Sport and Health Science · doi:10.1016/j.jshs.2020.12.004 · Cited by 69
“We used customized MATLAB-based software (MathWorks, Natick, MA, USA), which integrates cutpoint-based activity intensity classification(25) and sleep detection using the van Hees algorithm.(26) The software provides a graphical user interface displaying the acceleration trace, to allow visual identification of missin…”
MethodPrivacy implications of accelerometer data: a review of possible inferences
Kröger, J. L., Raschke, P., & Bhuiyan, T. R. (2019) · International Conference on Cryptography, Security and Privacy (CSP) · doi:10.1145/3309074.3309076 · Cited by 77
Husu, P., Tokola, K., Vähä‐Ypyä, H., Sievänen, H. T., Suni, J. H., Heinonen, O. J., Heiskanen, J., Kaikkonen, K., Savonen, K. P., Kokko, S. P., et al. (2021) · Journal for the Measurement of Physical Behaviour · doi:10.1123/jmpb.2020-0056 · Cited by 72
“The method used is nearly similar to the method described by van Hees et al. (2015).”
MethodCabanas‐Sánchez, V., Esteban‐Cornejo, I., Migueles, J. H., Banegas, J. R., Graciani, A., Rodríguez‐Artalejo, F., & Martínez‐Gómez, D. (2019) · Scandinavian Journal of Medicine and Science in Sports · doi:10.1111/sms.13612 · Cited by 69
Chen, B., Bernard, J. Y., Padmapriya, N., Ning, Y., Cai, S., Lança, C., Tan, K. H., Yap, F., Chong, Y.-S., Shek, L., et al. (2020) · The Lancet Child & Adolescent Health · doi:10.1016/s2352-4642(19)30424-9 · Cited by 57
Jakubec, L., Gába, A., Dygrýn, J., Rubín, L., Šimůnek, A., & Sigmund, E. (2020) · BMC Public Health · doi:10.1186/s12889-020-09213-3 · Cited by 66
Yerramalla, M. S., McGregor, D., van Hees, V. T., Fayossé, A., Dugravot, A., Tabák, Á. G., Chen, M., CHASTIN, S. F. M., & Sabia, S. (2021) · International Journal of Behavioral Nutrition and Physical Activity · doi:10.1186/s12966-021-01157-0 · Cited by 67
“Sleep periods were then detected using a validated algorithm guided by sleep log [31].”
MethodSelf-citationRubín, L., Gába, A., Dygrýn, J., Jakubec, L., Materová, E., & Vencálek, O. (2020) · BMC Public Health · doi:10.1186/s12889-020-09802-2 · Cited by 64
Antczak, D., Lonsdale, C., Cruz, B. D. P., Parker, P. D., & Sanders, T. (2021) · International Journal of Behavioral Nutrition and Physical Activity · doi:10.1186/s12966-021-01143-6 · Cited by 70
“For sleep detection, GGIR identifies periods of sustained inactivity where there is a smaller change in arm angle than a predefined threshold [25].”
MethodEcological and social pressures interfere with homeostatic sleep regulation in the wild
Loftus, J., Harel, R., Nuñez, C., & Crofoot, M. (2022) · eLife · doi:10.7554/elife.73695 · Cited by 63
The association between sleep and cognitive abnormalities in bipolar disorder
Bradley, A., Anderson, K. N., Gallagher, P., & McAllister-Williams, H. (2019) · Psychological Medicine · doi:10.1017/s0033291718004038 · Cited by 64
“In brief, the accelerometer data were analysed using an open source R package sleep detection algorithm, GGIR, which has demonstrated a high sensitivity and specificity to detect periods of sleep (van Hees et al., 2015).”
MethodSelf-citationTsanas, A., Woodward, E., & Ehlers, A. (2020) · JMIR mhealth and uhealth · doi:10.2196/14306 · Cited by 62
“For the algorithm of van Hees et al [29], we used their implementation in the GGIR package [43].”
InfluentialKoolhaas, C. M., van Rooij, F. J. A., Schoufour, J. D., Cepeda, M., Tiemeier, H. W., Brage, S., & Franco, O. H. (2017) · Journal of the American Medical Directors Association · doi:10.1016/j.jamda.2017.04.017 · Cited by 68
Rosique-Esteban, N., Papandreou, C., Romaguera, D., Wärnberǵ, J., Corella, D., Martínez‐González, M. Á., Díaz‐López, A., Estruch, R., Vioqué, J., Arós, F., et al. (2018) · SLEEP · doi:10.1093/sleep/zsy190 · Cited by 63
“The method of sleep detection has been previously validated in individuals with at least one valid night and it has been published elsewhere [22].”
MethodTroxel, W., Haas, A. C., Ghosh‐Dastidar, B., Holliday, S. B., Richardson, A. S., Schwartz, H. L., Gary‐Webb, T. L., Hale, L. E., Buysse, D. J., Buman, M. P., et al. (2020) · Journal of Urban Health · doi:10.1007/s11524-019-00418-5 · Cited by 63
Madrid-Navarro, C. J., Puertas, F. J., Sevilla, F. E., Campos, M., Abellán, F. R., Rol, M. A., & Madrid, J. A. (2019) · Frontiers in Neurology · doi:10.3389/fneur.2019.00356 · Cited by 58
Padmapriya, N., Chen, B., Goh, C. M. J. L., Shek, L. P., Chong, Y. S., Tan, K. H., Chan, S., Yap, F. K. P., Godfrey, K. M., Lee, Y. S., et al. (2021) · International Journal of Behavioral Nutrition and Physical Activity · doi:10.1186/s12966-021-01210-y · Cited by 58
Zitser, J., Anatürk, M., Zsoldos, E., Mahmood, A., Filippini, N., Suri, S., Leng, Y., Yaffe, K. S., Singh‐Manoux, A., Mika Kivimaki, B., et al. (2020) · SLEEP · doi:10.1093/sleep/zsz290 · Cited by 55
Self-citationMora-González, J., Esteban‐Cornejo, I., Solis‐Urra, P., Migueles, J. H., Cadenas‐Sánchez, C., Molina‐García, P., Rodríguez‐Ayllón, M., Hillman, C. H., Catena, A., Pontifex, M. B., et al. (2020) · Psychophysiology · doi:10.1111/psyp.13579 · Cited by 57
“A replacement by 0 for all metrics was performed if no data were collected for a specific time frame for the rest of the days; (d) Identification of waking and sleeping hours based on an automatized algorithm guided by the diaries completed by the participants (van Hees et al., 2015).”
MethodMartinez-Avila, W. D., Sánchez‐Delgado, G., Acosta, F. M., Jurado‐Fasoli, L., Oustric, P., Labayen, I., Blundell, J. E., & Ruiz, J. R. (2020) · Nutrients · doi:10.3390/nu12123685 · Cited by 53
Koopman‐Verhoeff, M. E., Serdarević, F., Kocevska, D., Bodrij, F. F., Mileva‐Seitz, V. R., Reiss, I. K. M., Hillegers, M. H. J., Tiemeier, H. W., Cecil, C. A. M., Verhulst, F. C., et al. (2019) · Journal of Child Psychology and Psychiatry · doi:10.1111/jcpp.13060 · Cited by 57
“This procedure generated the following variables: sleep duration, sleep efficiency, sleep onset, and waking time (van Hees et al., 2015).”
MethodGalmes-Panades, A. M., Varela-Mato, V., Konieczna, J., Wärnberǵ, J., Martínez‐González, M. Á., Salas‐Salvadó, J., Corella, D., Schröder, H., Vioqué, J., Alonso‐Gómez, Á. M., et al. (2019) · International Journal of Behavioral Nutrition and Physical Activity · doi:10.1186/s12966-019-0892-4 · Cited by 59
Zhu, G., Catt, M., Cassidy, S., Birch-Machin, M., Trenell, M., Hiden, H., Woodman, S., & Anderson, K. N. (2019) · PLOS ONE · doi:10.1371/journal.pone.0226220 · Cited by 49
“The generic algorithm has been assessed in a large UK study[25].”
MethodSelf-citationHachenberger, J., Teuber, Z., Li, Y., Abkai, L., Wild, E., & Lemola, S. (2023) · Scientific Reports · doi:10.1038/s41598-023-35987-8 · Cited by 55
Aktaruzzaman, M., Rivolta, M. W., Karmacharya, R., Scarabottolo, N., Pugnetti, L., Garegnani, M., Bovi, G., Scalera, G. M., Ferrarin, M., & Sassi, R. (2017) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2017.08.006 · Cited by 56
Validation of an automated sleep detection algorithm using data from multiple accelerometer brands
Plekhanova, T., Rowlands, A. V., Davies, M. J., Hall, A. P., Yates, T., & Edwardson, C. L. (2023) · Journal of Sleep Research · doi:10.1111/jsr.13760 · Cited by 45
“Recently, van Hees et al. (2015) developed a sleep detection algorithm based on angular wrist rotation measured with raw acceleration data.”
BackgroundResultInfluentialChanges in physical activity after bariatric surgery: using objective and self-reported measures
Afshar, S., Seymour, K., Kelly, S. B., Woodcock, S., van Hees, V. T., & Mathers, J. C. (2016) · Surgery for Obesity and Related Diseases · doi:10.1016/j.soard.2016.09.012 · Cited by 53
Scarlett, S., Nolan, H., Kenny, R. A., & O’Connell, M. D. L. (2020) · Sleep Health · doi:10.1016/j.sleh.2020.06.003 · Cited by 51
“Large studies examining agreement between subjective and objective measurements in community dwelling older adults are limited.(11,26) A number of large, population representative studies of older adults have introduced accelerometery measurement including The Irish Longitudinal Study on Ageing (TILDA),(27) the Englis…”
BackgroundTaylor, A. H., Taylor, R. S., Ingram, W. M., Anokye, N., Dean, S. G., Jolly, K. B., Mutrie, N., Lambert, J. D., Yardley, L., Greaves, C. J., et al. (2020) · Health Technology Assessment · doi:10.3310/hta24630 · Cited by 55
Lund, H. N., Pedersen, I. N., Johnsen, S. P., Heymann-Szlachcinska, A. M., Tuszewska, M., Bízik, G., Larsen, J. I., Kulhay, E., Larsen, A., Grønbech, B. E., et al. (2020) · Trials · doi:10.1186/s13063-020-04247-9 · Cited by 47
“The Music Star gives information from log files of music played, time, and duration [24].”
BackgroundMethodMatricciani, L., Dumuid, D., Paquet, C., Fraysse, F., Wang, Y., Baur, L. A., Juonala, M., Ranganathan, S., Lycett, K., Kerr, J. A., et al. (2021) · Sleep Medicine · doi:10.1016/j.sleep.2020.12.001 · Cited by 46
Roberts-Lewis, S. F., White, C. M., Ashworth, M. J., & Rose, M. R. (2021) · Disability and Rehabilitation · doi:10.1080/09638288.2021.1983042 · Cited by 53
A systematic review of the performance of actigraphy in measuring sleep stages
Yuan, H., Hill, E. A., Kyle, S. D., & Doherty, A. (2024) · Journal of Sleep Research · doi:10.1111/jsr.14143 · Cited by 55
Effects of different exercise training programs on body composition: A randomized control trial
Amaro‐Gahete, F. J., De‐la‐O, A., Jurado‐Fasoli, L., Ruiz, J. R., Castillo, M. J., & Gutiérrez, Á. (2019) · Scandinavian Journal of Medicine and Science in Sports · doi:10.1111/sms.13414 · Cited by 51
A Smartwatch Step Counter for Slow and Intermittent Ambulation
Genovese, V., Mannini, A., & Sabatini, A. M. (2017) · IEEE Access · doi:10.1109/access.2017.2702066 · Cited by 49
“Accelerometry is the technology of choice for wearable devices to measure and assess physical activity, with several applications documented, including gait and balance quality evaluation for fall risk assessment [6], [7], sleep assessment [8], fall detection and prevention [9].”
BackgroundComparison of Sedentary Time Between Thigh-Worn and Wrist-Worn Accelerometers
Suorsa, K., Pulakka, A., Leskinen, T., Pentti, J., Holtermann, A., Heinonen, O. J., Sunikka, J., Vahtera, J., & Stenholm, S. (2020) · Journal for the Measurement of Physical Behaviour · doi:10.1123/jmpb.2019-0052 · Cited by 47
“…magnitude of dynamic acceleration expressed as ENMO (as mg [milligravitational units] where g = 9.81 m/s2) over 5-s epochs with negative values rounded to zero (Migueles, Rowlands, Huber, Sabia, & van Hees, 2019; Sabia et al., 2014; van Hees, 2014; van Hees et al., 2013; van Hees et al., 2015).”
BackgroundMethodInfluentialGába, A., Dygrýn, J., Štefelová, N., Rubín, L., Hron, K., Jakubec, L., & Pedišić, Ž. (2020) · International Journal of Behavioral Nutrition and Physical Activity · doi:10.1186/s12966-020-01004-8 · Cited by 46
Actigraphy Enables Home Screening of Rapid Eye Movement Behavior Disorder in Parkinson's Disease
Raschellà, F., Scafa, S., Puiatti, A., Moraud, E. M., & Ratti, P. (2022) · Annals of Neurology · doi:10.1002/ana.26517 · Cited by 45
Activity Monitoring with a Wrist-Worn, Accelerometer-Based Device
Lin, W., Verma, V. K., Lee, M., & Lai, C. (2018) · Micromachines · doi:10.3390/mi9090450 · Cited by 44
Dumuid, D., Wake, M. A., Burgner, D. P., Tremblay, M. S., Okely, A. D., Edwards, B., Dwyer, T., & Olds, T. (2021) · PLoS ONE · doi:10.1371/journal.pone.0245501 · Cited by 47
“A MATLAB-based customized software program (Cobra), the algorithm by van Hees et al [24], visual inspection of accelerometer traces and the paper-based logs were used to identify sleep and non-wear time.”
MethodDuncan, M. J., Vandelanotte, C., Trost, S. G., Rebar, A. L., Rogers, N., Burton, N. W., Murawski, B., Rayward, A., Fenton, S., & Brown, W. J. (2016) · BMC Public Health · doi:10.1186/s12889-016-3256-x · Cited by 43
Häusler, N., Marques-Vidal, P. M., Haba‐Rubio, J., & Heinzer, R. C. (2019) · Sleep Medicine · doi:10.1016/j.sleep.2019.02.008 · Cited by 42
SciKit Digital Health: Python Package for Streamlined Wearable Inertial Sensor Data Processing
Adamowicz, L., Christakis, Y., Czech, M. D., & Adamusiak, T. (2022) · JMIR mhealth and uhealth · doi:10.2196/36762 · Cited by 46
“Sleep and physical activity monitoring, which typically use a wrist-based sensor, are also among extensively researched areas [11-18].”
BackgroundSegmenting accelerometer data from daily life with unsupervised machine learning
van Kuppevelt, D., Heywood, J., Hamer, M., Sabia, S., Fitzsimons, E., & van Hees, V. (2019) · PLOS ONE · doi:10.1371/journal.pone.0208692 · Cited by 41
“• Sustained inactivity: all continuous time periods with no z-angle change of more than 5 degrees lasting at least 5 minutes [8];”
BackgroundMethodSelf-citationTime in Nature Associated with Decreased Fatigue in UK Truck Drivers
Longman, D. P., Shaw, C. N., Varela-Mato, V., Sherry, A. P., Ruettger, K. B., Sayyah, M., Guest, A. J., Chen, Y., Paine, N. J., King, J. A., et al. (2021) · International Journal of Environmental Research and Public Health · doi:10.3390/ijerph18063158 · Cited by 43
“Sleep durations identified between self-reported, or algorithm defined, sleep onset time and out of bed time were calculated using a validated sleep detection algorithm [70].”
MethodMigueles, J. H., Cadenas‐Sánchez, C., Esteban‐Cornejo, I., Torres‐Lopez, L. V., Aadland, E., CHASTIN, S. F. M., Erickson, K. I., Catena, A., & Ortega, F. B. (2020) · Journal of Clinical Medicine · doi:10.3390/jcm9041080 · Cited by 46
Short-term effect of physical activity on sleep health: A population-based study using accelerometry
Wendt, A. T., Crochemore‐Silva, I., Gonçalves, H., Menezes, A. M. B., Barros, F. C., & Wehrmeister, F. C. (2020) · Journal of sport and health science/Journal of Sport and Health Science · doi:10.1016/j.jshs.2020.04.007 · Cited by 46
“All algorithms and cut-offs for PA and sleep were validated to triaxial accelerometers previously.(31,34)”
Method
Metadata
- Authors
- van Hees, V. T., Sabia, S., Anderson, K. N., Denton, S. J., Oliver, J., Catt, M., Abell, J. G., Kivimäki, M., Trenell, M. I., & Singh-Manoux, A.
- Affiliations
- Freeman Hospital (GB)
- Newcastle University (GB)
- University College London (GB)
- Venue
- PLOS ONE
- Publisher
- Public Library of Science (PLoS)
- Published
- 2015-11-16
- Volume
- 10
- Issue
- 11
- Pages
- e0142533
- ISSN
- 1932-6203 (ISSN-L)
- PMC
- PMC4646630
- OpenAlex
- W2180429985
- Cited by
- 744
- References
- 39
- Citations by year
- 2026: 86 · 2025: 102 · 2024: 101 · 2023: 85 · 2022: 97 · 2021: 68 · 2020: 105 · 2019: 45 · 2018: 31 · 2017: 17 · 2016: 6
- FWCI
- 27.20
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Licence
- Locations
- PLoS ONE (publishedVersion, cc-by)
- Europe PMC (PubMed Central) (publishedVersion, cc-by)
- PubMed Central (publishedVersion, cc-by)
- PubMed (publishedVersion)
- RePEc: Research Papers in Economics (submittedVersion)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
- UCL Discovery (University College London) (submittedVersion)
- Figshare (submittedVersion, cc-by)
- Newcastle University ePrints (Newcastle Univesity) (cc-by)
- Funders
- National Institute for Health and Care Research (R01AG034454, SRF-2011-04-017)
- British Heart Foundation (R01 AG013196, R01AG034454, K013351, PG/29605)
- National Institutes of Health (R01AG013196; R01AG034454; R01HL036310)
- Medical Research Council (MR/K013351/1, K013351, MR/K006312/1, R01AG034454)
- Economic and Social Research Council (R01AG034454, ES/J023299/1, ES/ J023299, R01HL036310, J023299)
- National Institute on Aging (R01AG034454, R01AG013196)
- National Heart, Lung, and Blood Institute (R01HL036310)
- National Institute of Environmental Health Sciences (ES/J023299)
- Topics
- Social Sciences › Psychology › Experimental and Cognitive Psychology › Sleep and related disorders
- Physical Sciences › Computer Science › Computer Vision and Pattern Recognition › Context-Aware Activity Recognition Systems
- Health Sciences › Medicine › Public Health, Environmental and Occupational Health › Physical Activity and Health
- Keywords
- sleep duration, wrist-worn accelerometers, physical activity monitoring, time in bed, total sleep duration, sleep diary, polysomnography validation, older adults, insomnia, depression, weekend effect, Whitehall II study
- MeSH terms
- Acceleration, Aged, Aged, 80 and over, Algorithms, Depression, Equipment Design, Female, United Kingdom, Humans, Sleep Initiation and Maintenance Disorders, Male, Middle Aged, Monitoring, Physiologic, Motor Activity, Surveys and Questionnaires, Sex Factors, Sleep, Sleep Wake Disorders, Time Factors, Wrist, Polysomnography, Actigraphy
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.
