The Clinical Plasma Proteome: A Survey of Clinical Assays for Proteins in Plasma and Serum
The DOI matches its Crossref record; 18 of the 18 references it cites were found in a registry or an index.
Abstract
An analysis of all US Food and Drug Administration (FDA) approvals for protein-based assays through 2008 reveals 109 unique protein targets in plasma or serum, as well as 62 additional tests for peptides, protein posttranslational modifications, protein complexes, autoantibodies against endogenous proteins, and blood cell proteins. A further 96 unique protein targets are assayed in plasma by laboratory-developed tests available for clinical use in the US, yielding a total of 205 proteins that include products of approximately 211 genes (excluding immunoglobulins). These tests provide quantitative measurements for approximately 1% of the human protein gene products, defining a practical clinical plasma proteome. The rate of introduction of new protein analytes has remained essentially flat over the past 15 years, averaging 1.5 new proteins per year (median of 1 per year). This rate falls far short of that needed to support projected medical needs and indicates serious deficiencies in the protein biomarker pipeline, from which no proteomics-discovered analytes have yet emerged.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Anderson, N. L., & Anderson, N. G. (2002) · Molecular & Cellular Proteomics · doi:10.1074/mcp.r200007-mcp200 · Cited by 4,414
Self-citationImmunoassay of endogenous plasma insulin in man
Yalow, R. S., & Berson, S. A. (1960) · Journal of Clinical Investigation · doi:10.1172/jci104130 · Cited by 3,041
Tietz Textbook of Clinical Chemistry
(1999) · Archives of Pathology and Laboratory Medicine · doi:10.5858/123.7.646b · Cited by 2,495
Protein biomarker discovery and validation: the long and uncertain path to clinical utility
Rifai, N., Gillette, M. A., & Carr, S. A. (2006) · Nature Biotechnology · doi:10.1038/nbt1235 · Cited by 1,867
Addona, T. A., Abbatiello, S. E., Schilling, B., Skates, S. J., Mani, D. R., Bunk, D. M., Spiegelman, C. H., Zimmerman, L. J., Ham, A.-J. L., Keshishian, H., et al. (2009) · Nature Biotechnology · doi:10.1038/nbt.1546 · Cited by 1,037 · cited 1×
“If MS methods are able to achieve immunoassay sensitivity (approaching ng/L concentrations) and precision (18) at comparable cost, then similar MS instrument platforms could find use in both biomarker research and development (where a comprehensive library of specific assays for all human proteins has been proposed (1…”
BackgroundSelf-citationOmenn, G. S., States, D. J., Adamski, M., Blackwell, T. W., Menon, R., Hermjakob, H., Apweiler, R., Haab, B. B., Simpson, R. J., Eddes, J. S., et al. (2005) · PROTEOMICS · doi:10.1002/pmic.200500358 · Cited by 787
Distinguishing protein-coding and noncoding genes in the human genome
Clamp, M., Fry, B., Kamal, M., Xie, X., Cuff, J., Lin, M. F., Kellis, M., Lindblad-Toh, K., & Lander, E. S. (2007) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0709013104 · Cited by 624
The fundamental flaws of immunoassays and potential solutions using tandem mass spectrometry
Hoofnagle, A. N., & Wener, M. H. (2009) · Journal of Immunological Methods · doi:10.1016/j.jim.2009.06.003 · Cited by 561
Bias as a threat to the validity of cancer molecular-marker research
Ransohoff, D. F. (2005) · Nature Reviews Cancer · doi:10.1038/nrc1550 · Cited by 487
IMMUNOASSAY OF ENDOGENOUS PLASMA INSULIN IN MAN
YALOW, R. S., & BERSON, S. A. (1996) · Obesity Research · doi:10.1002/j.1550-8528.1996.tb00274.x · Cited by 460
Cited by
Protein Analysis by Shotgun/Bottom-up Proteomics
Zhang, Y., Fonslow, B. R., Shan, B., Baek, M.-C., & Yates, J. R. (2013) · Chemical Reviews · doi:10.1021/cr3003533 · Cited by 1,491
Biomedical research: increasing value, reducing waste.
Macleod, M. R., Michie, S., Roberts, I., Dirnagl, U., Chalmers, I., Ioannidis, J. P. A., Salman, R. A.-S., Chan, A.-W., & Glasziou, P. (2014) · The Lancet · doi:10.1016/s0140-6736(13)62329-6 · Cited by 1,003
Revisiting biomarker discovery by plasma proteomics
Geyer, P. E., Holdt, L. M., Teupser, D., & Mann, M. (2017) · Molecular Systems Biology · doi:10.15252/msb.20156297 · Cited by 917
“In this sense, there are more than 100 FDA-cleared or FDA-approved clinical plasma or serum tests, mainly in the abundant, functional class (50%), followed by tissue leakage markers (25%), and the rest include receptor ligands, immunoglobulins, and aberrant secretions (Anderson, 2010).”
BackgroundPlasma Proteome Profiling to Assess Human Health and Disease
Geyer, P. E., Kulak, N. A., Pichler, G., Holdt, L. M., Teupser, D., & Mann, M. (2016) · Cell Systems · doi:10.1016/j.cels.2016.02.015 · Cited by 734
“5 per year in the 15 years before 2010 (Anderson, 2010)— and this has generally been done by immunoassay-based technologies, such as prostate-specific antigen, one of the best known biomarkers in medicine (Vihko et al.”
BackgroundMethodInfluentialHigh-Resolution Native Mass Spectrometry
Tamara, S., den Boer, M. A., & Heck, A. J. R. (2022) · Chemical Reviews · doi:10.1021/acs.chemrev.1c00212 · Cited by 511
Quantitative analysis of peptides and proteins in biomedicine by targeted mass spectrometry
Gillette, M. A., & Carr, S. A. (2013) · Nature Methods · doi:10.1038/nmeth.2309 · Cited by 495
Genetics meets proteomics: perspectives for large population-based studies
Suhre, K., McCarthy, M. I., & Schwenk, J. M. (2021) · Nature Reviews Genetics · doi:10.1038/s41576-020-0268-2 · Cited by 478
Wilson, D. H., Rissin, D. M., Kan, C. W., Fournier, D. R., Piech, T., Campbell, T. G., Meyer, R. E., Fishburn, M. W., Cabrera, C., Patel, P. P., et al. (2016) · SLAS Technology · doi:10.1177/2211068215589580 · Cited by 470
Rapid, deep and precise profiling of the plasma proteome with multi-nanoparticle protein corona
Blume, J. E., Manning, W. C., Troiano, G., Hornburg, D., Figa, M., Hesterberg, L., Platt, T. L., Zhao, X., Cuaresma, R. A., Everley, P. A., et al. (2020) · Nature Communications · doi:10.1038/s41467-020-17033-7 · Cited by 452
Comparative Human Salivary and Plasma Proteomes
Loo, J. A., Yan, W., Ramachandran, P., & Wong, D. T. (2010) · Journal of Dental Research · doi:10.1177/0022034510380414 · Cited by 444
Mass spectrometry-based proteomics: existing capabilities and future directions
Angel, T. E., Aryal, U. K., Hengel, S. M., Baker, E. S., Kelly, R. T., Robinson, E. W., & Smith, R. D. (2012) · Chemical Society Reviews · doi:10.1039/c2cs15331a · Cited by 441
A targeted proteomics–based pipeline for verification of biomarkers in plasma
Whiteaker, J. R., Lin, C., Kennedy, J., Hou, L., Trute, M., Sokal, I., Yan, P., Schoenherr, R. M., Zhao, L., Voytovich, U. J., et al. (2011) · Nature Biotechnology · doi:10.1038/nbt.1900 · Cited by 364
Vidova, V., & Spacil, Z. (2017) · Analytica Chimica Acta · doi:10.1016/j.aca.2017.01.059 · Cited by 352
Quantitative variability of 342 plasma proteins in a human twin population
Liu, Y., Buil, A., Collins, B. C., Gillet, L. C., Blum, L. C., Cheng, L., Vitek, O., Mouritsen, J., Lachance, G., Spector, T. D., et al. (2015) · Molecular Systems Biology · doi:10.15252/msb.20145728 · Cited by 328
Sweetening the Pot: Adding Glycosylation to the Biomarker Discovery Equation
Drake, P. M., Cho, W., Li, B., Prakobphol, A., Johansen, E., Anderson, N. L., Regnier, F. E., Gibson, B. W., & Fisher, S. J. (2010) · Clinical Chemistry · doi:10.1373/clinchem.2009.136333 · Cited by 302
Self-citationLarge-scale serum protein biomarker discovery in Duchenne muscular dystrophy
Hathout, Y., Brody, E., Clemens, P. R., Cripe, L., DeLisle, R. K., Furlong, P., Gordish-Dressman, H., Hache, L., Henricson, E., Hoffman, E. P., et al. (2015) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1507719112 · Cited by 290
Vogeser, M., & Seger, C. (2010) · Clinical Chemistry · doi:10.1373/clinchem.2009.138602 · Cited by 290
Quantification of protein interactions and solution transport using high-density GMR sensor arrays
Gaster, R. S., Xu, L., Han, S.-J., Wilson, R. J., Hall, D. A., Osterfeld, S. J., Yu, H., & Wang, S. X. (2011) · Nature Nanotechnology · doi:10.1038/nnano.2011.45 · Cited by 272
Cohen, L., Cui, N., Cai, Y., Garden, P. M., Li, X., Weitz, D. A., & Walt, D. R. (2020) · ACS Nano · doi:10.1021/acsnano.0c02378 · Cited by 263
The use of mass spectrometry to analyze dried blood spots
Wagner, M., Tonoli, D., Varesio, E., & Hopfgartner, G. (2016) · Mass Spectrometry Reviews · doi:10.1002/mas.21441 · Cited by 262
Advances in targeted proteomics and applications to biomedical research
Shi, T., Song, E., Nie, S., Rodland, K. D., Liu, T., Qian, W., & Smith, R. D. (2016) · PROTEOMICS · doi:10.1002/pmic.201500449 · Cited by 257
Ignjatovic, V., Geyer, P. E., Palaniappan, K. K., Chaaban, J. E., Omenn, G. S., Baker, M. S., Deutsch, E. W., & Schwenk, J. M. (2019) · Journal of Proteome Research · doi:10.1021/acs.jproteome.9b00503 · Cited by 229
Sajic, T., Liu, Y., & Aebersold, R. (2015) · PROTEOMICS – Clinical Applications · doi:10.1002/prca.201400117 · Cited by 210
Smith, J. G., & Gerszten, R. E. (2017) · Circulation · doi:10.1161/circulationaha.116.025446 · Cited by 206
Skin in the diagnostics game: Wearable biosensor nano- and microsystems for medical diagnostics
Dervisevic, M., Alba, M., Prieto-Simon, B., & Voelcker, N. H. (2020) · Nano Today · doi:10.1016/j.nantod.2019.100828 · Cited by 203
LC–MS/MS for protein and peptide quantification in clinical chemistry
Rauh, M. (2012) · Journal of Chromatography B · doi:10.1016/j.jchromb.2011.09.030 · Cited by 171
Stepien, G., Moros, M., Pérez-Hernández, M., Monge, M., Gutiérrez, L., Fratila, R. M., las Heras, M. D., Menao Guillén, S., Puente Lanzarote, J. J., Solans, C., et al. (2018) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.7b18648 · Cited by 158
Corey, K. E., Pitts, R., Lai, M., Loureiro, J., Masia, R., Osganian, S. A., Gustafson, J. L., Hutter, M. M., Gee, D. W., Meireles, O. R., et al. (2022) · Journal of Hepatology · doi:10.1016/j.jhep.2021.09.026 · Cited by 88
Carrasco-Zanini, J., Pietzner, M., Koprulu, M., Wheeler, E., Kerrison, N. D., Wareham, N. J., & Langenberg, C. (2024) · The Lancet Digital Health · doi:10.1016/s2589-7500(24)00087-6 · Cited by 46
Rezeli, M., Végvári, Á., Donnarumma, F., Gidlöf, O., Smith, J. G., Erlinge, D., & Marko-Varga, G. (2013) · Journal of Proteomics · doi:10.1016/j.jprot.2013.05.016 · Cited by 33
“[18] Anderson NL.”
BackgroundSissala, N., Babačić, H., Leo, I. R., Cao, X., Forshed, J., Eriksson, L. E., Lehtiö, J., Fredolini, C., Åberg, M., & Pernemalm, M. (2025) · Communications Chemistry · doi:10.1038/s42004-025-01753-2 · Cited by 25
Increase value and reduce waste in research on psychological therapies
Cristea, I. A., & Naudet, F. (2019) · Behaviour Research and Therapy · doi:10.1016/j.brat.2019.103479 · Cited by 22
Rezeli, M., Végvári, Á., Fehniger, T. E., Laurell, T., & Marko-Varga, G. (2011) · Journal of Clinical Bioinformatics · doi:10.1186/2043-9113-1-7 · Cited by 15
Quality requirements for quantitative clinical chemistry proteomics
(2014) · Translational Proteomics · doi:10.1016/j.trprot.2013.10.001 · Cited by 11
Metadata
- Authors
- Anderson, N. L.
- Venue
- Clinical Chemistry
- Publisher
- Oxford University Press (OUP)
- Published
- 2010-02-01
- Volume
- 56
- Issue
- 2
- Pages
- 177-185
- ISSN
- 0009-9147 (ISSN-L)
- 1530-8561
- OpenAlex
- W2160061958
- Cited by
- 562
- References
- 18
- FWCI
- 14.04
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.