The DOI matches its Crossref record; 81 of the 81 references it cites were found in a registry or an index.
Cochlear implants: Current designs and future possibilities
Abstract
The cochlear implant is the most successful of all neural prostheses developed to date. It is the most effective prosthesis in terms of restoration of function, and the people who have received a cochlear implant outnumber the recipients of other types of neural prostheses by orders of magnitude. The primary purpose of this article is to provide an overview of contemporary cochlear implants from the perspective of two designers of implant systems. That perspective includes the anatomical situation presented by the deaf cochlea and how the different parts of an implant system (including the user's brain) must work together to produce the best results. In particular, we present the design considerations just mentioned and then describe in detail how the current levels of performance have been achieved. We also describe two recent advances in implant design and performance. In concluding sections, we first present strengths and limitations of present systems and then offer some possibilities for further improvements in this technology. In all, remarkable progress has been made in the development of cochlear implants but much room still remains for improvements, especially for patients presently at the low end of the performance spectrum.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Which elements are excited in electrical stimulation of mammalian central nervous system: A review
Ranck, J. B. (1975) · Brain Research · doi:10.1016/0006-8993(75)90364-9 · Cited by 2,024
Discharge Patterns of Single Fibers in the Cat's Auditory Nerve
Nelson, S. B., Watanabe, T., Thomas, E. C., & Louise, F. C. (1966) · Defense Technical Information Center (DTIC) · Cited by 1,531
Mechanics of the Mammalian Cochlea
Robles, L., & Ruggero, M. A. (2001) · Physiological Reviews · doi:10.1152/physrev.2001.81.3.1305 · Cited by 1,476
Ann Otol Rhinol Laryngol [Suppl].
Cw, C. (1978) · PubMed · Cited by 1,313
Auditory-nerve response from cats raised in a low-noise chamber
Liberman, M. C. (1978) · The Journal of the Acoustical Society of America · doi:10.1121/1.381736 · Cited by 1,203
Better speech recognition with cochlear implants
Wilson, B. S., Finley, C. C., Lawson, D. T., Wolford, R. D., Eddington, D. K., & Rabinowitz, W. M. (1991) · Nature · doi:10.1038/352236a0 · Cited by 1,190
Self-citationFriesen, L. M., Shannon, R. V., Baskent, D., & Wang, X. (2001) · The Journal of the Acoustical Society of America · doi:10.1121/1.1381538 · Cited by 1,049
Cross-modal plasticity: where and how?
Bavelier, D., & Neville, H. J. (2002) · Nature Reviews Neuroscience · doi:10.1038/nrn848 · Cited by 1,040
Rf, G. (1985) · Cited by 949
Chimaeric sounds reveal dichotomies in auditory perception
Smith, Z. M., Delgutte, B., & Oxenham, A. J. (2002) · Nature · doi:10.1038/416087a · Cited by 873
Dallos, P. (1992) · The Journal of Neuroscience · doi:10.1523/jneurosci.12-12-04575.1992 · Cited by 710
Electric-Acoustic Stimulation of the Auditory System
vonIlberg, C., Kiefer, J., Tillein, J., Pfenningdorff, T., Hartmann, R., Stürzebecher, E., & Klinke, R. (1999) · ORL · doi:10.1159/000027695 · Cited by 508
Gantz, B. J., Turner, C., Gfeller, K. E., & Lowder, M. W. (2005) · The Laryngoscope · doi:10.1097/01.mlg.0000157695.07536.d2 · Cited by 502
Cross-modal plasticity and cochlear implants
Lee, D. S., Lee, J. S., Oh, S. H., Kim, S.-K., Kim, J.-W., Chung, J.-K., Lee, M. C., & Kim, C. S. (2001) · Nature · doi:10.1038/35051653 · Cited by 480
Grundzüge einer allgemeinen Theorie der linearen Integralgleichungen
Hilbert, D. (1989) · Teubner-Archiv zur Mathematik · doi:10.1007/978-3-322-84410-1_1 · Cited by 450
Auditory‐Nerve Activity in Cats with Normal and Abnormal Cochleas
Kiang, N. Y. S., Moxon, E. C., & Levine, R. A. (1970) · Novartis Foundation Symposia · doi:10.1002/9780470719756.ch15 · Cited by 385
Speech recognition with amplitude and frequency modulations
Zeng, F.-G., Nie, K., Stickney, G. S., Kong, Y.-Y., Vongphoe, M., Bhargave, A., Wei, C., & Cao, K. (2005) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0406460102 · Cited by 383
Fishman, K. E., Shannon, R. V., & Slattery, W. H. (1997) · Journal of Speech, Language, and Hearing Research · doi:10.1044/jslhr.4005.1201 · Cited by 380
Combining acoustic and electrical hearing
Gantz, B. J., & Turner, C. W. (2003) · The Laryngoscope · doi:10.1097/00005537-200310000-00012 · Cited by 377
Speech recognition in noise for cochlear implant listeners: Benefits of residual acoustic hearing
Turner, C. W., Gantz, B. J., Vidal, C., Behrens, A., & Henry, B. A. (2004) · The Journal of the Acoustical Society of America · doi:10.1121/1.1687425 · Cited by 363
Speech and melody recognition in binaurally combined acoustic and electric hearing
Kong, Y.-Y., Stickney, G. S., & Zeng, F.-G. (2005) · The Journal of the Acoustical Society of America · doi:10.1121/1.1857526 · Cited by 351
Temporal pitch in electric hearing
Zeng, F.-G. (2002) · Hearing Research · doi:10.1016/s0378-5955(02)00644-5 · Cited by 314
Conservation of low-frequency hearing in cochlear implantation
Kiefer, J., Gstoettner, W. K., Baumgartner, W., Pok, S. M., Tillein, J., Ye, Q., & Ilberg, C. V. (2004) · Acta Oto-Laryngologica · doi:10.1080/00016480310000755a · Cited by 309
Physiology of Olivocochlear Efferents
Guinan, J. J. (1996) · Springer Handbook of Auditory Research · doi:10.1007/978-1-4612-0757-3_8 · Cited by 307
Discharge patterns of cat primary auditory fibers with electrical stimulation of the cochlea
Hartmann, R., Topp, G., & Klinke, R. (1984) · Hearing Research · doi:10.1016/0378-5955(84)90094-7 · Cited by 298
Histopathology of Cochlear Implants in Humans
Nadol, J. B., Burgess, B. J., Gantz, B. J., Coker, N. J., Ketten, D. R., Kos, I., Roland, J. T., Shiao, J. Y., Eddington, D. K., Montandon, P., et al. (2001) · Annals of Otology, Rhinology & Laryngology · doi:10.1177/000348940111000914 · Cited by 292
Shepherd, R. K., & Javel, E. (1997) · Hearing Research · doi:10.1016/s0378-5955(97)00046-4 · Cited by 292
Hearing preservation in cochlear implantation for electric acoustic stimulation
Gstoettner, W., Kiefer, J., Baumgartner, W.-D., Pok, S., Peters, S., & Adunka, O. (2004) · Acta Oto-Laryngologica · doi:10.1080/00016480410016432 · Cited by 277
Skinner, M. W., Clark, G. M., Whitford, L. A., Seligman, P., Staller, S. J., Shipp, D. B., Shallop, J. K., Everingham, C., Menapace, C., & Arndt, P. L. (1994) · PubMed · Cited by 276
Rubinstein, J. T., Wilson, B. S., Finley, C. C., & Abbas, P. J. (1999) · Hearing Research · doi:10.1016/s0378-5955(98)00185-3 · Cited by 276
Self-citationDorman, M. F., Gifford, R. H., Spahr, A. J., & McKarns, S. A. (2008) · Audiology and Neurotology · doi:10.1159/000111782 · Cited by 275
Schleich, P., Nopp, P., & D’Haese, P. (2004) · Ear and Hearing · doi:10.1097/01.aud.0000130792.43315.97 · Cited by 268
Rapid development of cortical auditory evoked potentials after early cochlear implantation
Sharma, A., Dorman, M. F., & Spahr, A. J. (2002) · Neuroreport · doi:10.1097/00001756-200207190-00030 · Cited by 260
MED-EL Cochlear Implants: State of the Art and a Glimpse Into the Future
Hochmair, I., Nopp, P., Jolly, C., Schmidt, M., Schößer, H., Garnham, C., & Anderson, I. (2006) · Trends in Amplification · doi:10.1177/1084713806296720 · Cited by 254
Temporal processing and speech recognition in cochlear implant users
Fu, Q.-J. (2002) · NeuroReport · doi:10.1097/00001756-200209160-00013 · Cited by 237
Fraysse, B., Macías, Á. R., Sterkers, O., Burdo, S., Ramsden, R., Deguine, O., Klenzner, T., Lenarz, T., Rodriguez, M. M., Von Wallenberg, E., et al. (2006) · Otology & Neurotology · doi:10.1097/01.mao.0000226289.04048.0f · Cited by 237
Adunka, O., Unkelbach, M. H., MacK, M., Hambek, M., Gstoettner, W., & Kiefer, J. (2004) · Acta Oto-Laryngologica · doi:10.1080/00016480410018179 · Cited by 228
Multichannel Cochlear Implants: Relation of Histopathology to Performance
Fayad, J. N., & Linthicum, F. H. (2006) · The Laryngoscope · doi:10.1097/01.mlg.0000227176.09500.28 · Cited by 222
Cochlear Implants in Adults and Children
Gates, G. A. (1995) · JAMA: The Journal of the American Medical Association · doi:10.1001/jama.1995.03530240065043 · Cited by 211
Single fiber mapping of spatial excitation patterns in the electrically stimulated auditory nerve
van den Honert, C., & Stypulkowski, P. H. (1987) · Hearing Research · doi:10.1016/0378-5955(87)90167-5 · Cited by 209
Encoding Frequency Modulation to Improve Cochlear Implant Performance in Noise
Nie, K., Stickney, G., & Zeng, F.-G. (2005) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2004.839799 · Cited by 209
Deafness-Induced Changes in the Auditory Pathway: Implications for Cochlear Implants
Shepherd, R. K., & Hardie, N. A. (2001) · Audiology and Neurotology · doi:10.1159/000046843 · Cited by 189
National Institutes of Health Consensus Conference.
Fink, M. (1985) · PubMed · Cited by 180
Gantz, B. J., Turner, C., & Gfeller, K. E. (2006) · Audiology and Neurotology · doi:10.1159/000095616 · Cited by 170
Cochlear Implants: Some Likely Next Steps
Wilson, B. S., Lawson, D. T., Müller, J. M., Tyler, R. S., & Kiefer, J. (2003) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.5.040202.121645 · Cited by 160
Self-citationAuditory Prosthesis with a Penetrating Nerve Array
Middlebrooks, J. C., & Snyder, R. L. (2007) · Journal of the Association for Research in Otolaryngology · doi:10.1007/s10162-007-0070-2 · Cited by 158
Frijns, J. H. M., Briaire, J. J., & Grote, J. J. (2001) · Otology & Neurotology · doi:10.1097/00129492-200105000-00012 · Cited by 155
Incremental training increases the plasticity of the auditory space map in adult barn owls
Linkenhoker, B. A., & Knudsen, E. I. (2002) · Nature · doi:10.1038/nature01002 · Cited by 153
Current steering creates additional pitch percepts in adult cochlear implant recipients
Firszt, J. B., Koch, D. B., Downing, M., & Litvak, L. (2007) · Otology & Neurotology · doi:10.1097/01.mao.0000281803.36574.bc · Cited by 150
HISTOPATHOLOGY OF PROFOUND SENSORINEURAL DEAFNESSa
Hinojosa, R., & Marion, M. S. (1983) · Annals of the New York Academy of Sciences · doi:10.1111/j.1749-6632.1983.tb31662.x · Cited by 148
Place-pitch discrimination of single- versus dual-electrode stimuli by cochlear implant users
Donaldson, G. S., Kreft, H. A., & Litvak, L. M. (2005) · The Journal of the Acoustical Society of America · doi:10.1121/1.1937362 · Cited by 140
Enhancing temporal cues to voice pitch in continuous interleaved sampling cochlear implants
Green, T. J., Faulkner, A., & Rosen, S. (2004) · The Journal of the Acoustical Society of America · doi:10.1121/1.1785611 · Cited by 130
Cochlear implants and ex vivo BDNF gene therapy protect spiral ganglion neurons
Rejali, D., Lee, V. A., Abrashkin, K. A., Humayun, N., Swiderski, D. L., & Raphael, Y. (2007) · Hearing Research · doi:10.1016/j.heares.2007.02.010 · Cited by 129
Speech and music perception with the new fine structure speech coding strategy: preliminary results
Arnoldner, C., Riss, D., Brunner, M., Ďurišin, M., Baumgartner, W., & Hamzavi, J. (2007) · Acta Oto-Laryngologica · doi:10.1080/00016480701275261 · Cited by 125
Strategies to preserve or regenerate spiral ganglion neurons
Roehm, P. C., & Hansen, M. R. (2005) · Current Opinion in Otolaryngology & Head & Neck Surgery · doi:10.1097/01.moo.0000180919.68812.b9 · Cited by 118
Performance of Patients Using Different Cochlear Implant Systems: Effects of Input Dynamic Range
Spahr, A. J., Dorman, M. F., & Loiselle, L. H. (2007) · Ear and Hearing · doi:10.1097/aud.0b013e3180312607 · Cited by 113
Pitch ranking with nonsimultaneous dual-electrode electrical stimulation of the cochlea
McDermott, H. J., & McKay, C. M. (1994) · The Journal of the Acoustical Society of America · doi:10.1121/1.410475 · Cited by 107
Thirty years of theBritish Journal of Audiology: Guest editorial: The future of cochlear implants
Wilson, B. S. (1997) · British Journal of Audiology · doi:10.3109/03005369709076795 · Cited by 106
Self-citationUsing Current Steering to Increase Spectral Resolution in CII and HiRes 90K Users
Koch, D. B., Downing, M., Osberger, M. J., & Litvak, L. M. (2007) · Ear and Hearing · doi:10.1097/aud.0b013e31803150de · Cited by 105
Preservation of Basal Inner Ear Structures in Cochlear Implantation
Adunka, O. F., Gstoettner, W., Hambek, M., et al. (2004) · ORL · doi:10.1159/000081887 · Cited by 100
Acoustic Simulations of Combined Electric and Acoustic Hearing (EAS)
Dorman, M., Spahr, A., Loizou, P., Dana, C. J., & Schmidt, J. S. (2005) · Ear and Hearing · doi:10.1097/00003446-200508000-00001 · Cited by 94
Koch, D. B., Osberger, M. J., Segel, P., & Kessler, D. K. (2004) · Audiology and Neurotology · doi:10.1159/000078391 · Cited by 93
Pettingill, L. N., Richardson, R. T., Wise, A. K., O’Leary, S. J., & Shepherd, R. K. (2007) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2007.895375 · Cited by 87
Combined Electroacoustic Stimulation in Conventional Candidates for Cochlear Implantation
James, C. J., Fraysse, B., Déguine, O., Lenarz, T., Mawman, D. J., Ramos, Á., Ramsden, R. T., & Sterkers, O. (2006) · Audiology and Neurotology · doi:10.1159/000095615 · Cited by 86
Perimodiolar Electrodes in Cochlear Implant Surgery
Gstoettner, O. A. W. K. (2001) · Acta Oto-Laryngologica · doi:10.1080/000164801300043569 · Cited by 85
Ye, Q., Tillein, J., Hartmann, R., Gstoettner, W., & Kiefer, J. (2007) · Ear and Hearing · doi:10.1097/01.aud.0000261655.30652.62 · Cited by 83
Two New Directions in Speech Processor Design for Cochlear Implants
Wilson, B. S., Schatzer, R., Lopez‐Poveda, E. A., Sun, X., Lawson, D. T., & Wolford, R. D. (2005) · Ear and Hearing · doi:10.1097/00003446-200508001-00009 · Cited by 79
Self-citationComparative studies of speech processing strategies for cochlear implants
Wilson, B. S., Finley, C. C., Weber, B. A., White, M. W., Farmer, J. C., Wolford, R. D., Merzenich, M. M., Lawson, D. T., Kenan, P. D., & Schindler, R. A. (1988) · The Laryngoscope · doi:10.1288/00005537-198810000-00009 · Cited by 74
Self-citationThe Surprising Performance of Present-Day Cochlear Implants
Wilson, B. S., & Dorman, M. F. (2007) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2007.893505 · Cited by 72
Self-citationKiefer, J., Ilberg, C. V., Hubner-Egner, J., Rupprecht, V., & Knecht, R. (2000) · Annals of Otology Rhinology & Laryngology · doi:10.1177/000348940010901105 · Cited by 69
Are spiral ganglion cell numbers important for speech perception with a cochlear implant?
Blamey, P. J. (1997) · PubMed · Cited by 67
Engineering Design of Cochlear Implants
Wilson, B. S. (2004) · Springer handbook of auditory research · doi:10.1007/978-0-387-22585-2_2 · Cited by 57
Self-citationCochlear Nerve Stimulation with a 3-Dimensional Penetrating Electrode Array
Hillman, T. A., Badi, A. N., Normann, R. A., Kertesz, T., & Shelton, C. (2003) · Otology & Neurotology · doi:10.1097/00129492-200309000-00013 · Cited by 54
Modiolar Proximity of Three Perimodiolar Cochlear Implant Electrodes
Bałkany, T. J., Eshraghi, A. A., & Yang, N. W. (2002) · Acta Oto-Laryngologica · doi:10.1080/00016480260000021 · Cited by 54
Wilson, B. S., & Dorman, M. F. (2008) · IEEE Sensors Journal · doi:10.1109/jsen.2007.912917 · Cited by 44
Self-citationThe Design and Function of Cochlear Implants
Dorman, M. F., & Wilson, B. S. (2004) · American Scientist · doi:10.1511/2004.49.942 · Cited by 44
Self-citationDevelopment of a Novel Eighth‐Nerve Intraneural Auditory Neuroprosthesis
Badi, A. N., Kertesz, T. R., Gurgel, R. K., Shelton, C., & Normann, R. A. (2003) · The Laryngoscope · doi:10.1097/00005537-200305000-00012 · Cited by 38
Cochlear Electrode Arrays: Past, Present and Future
Spelman, F. A. (2006) · Audiology and Neurotology · doi:10.1159/000090680 · Cited by 36
Anatomical Considerations and Long-Term Effects of Electrical Stimulation
Leake, P. A., & Rebscher, S. J. (2004) · Springer handbook of auditory research · doi:10.1007/978-0-387-22585-2_4 · Cited by 26
Prosthetic Stimulation of the Auditory System with Intraneural Electrodes
Arts, H. A., Jones, D. A., & Anderson, D. J. (2003) · Annals of Otology, Rhinology & Laryngology · doi:10.1177/00034894031120s905 · Cited by 22
Electrode Independence in Intraneural Cochlear Nerve Stimulation
Badi, A. N., Owa, A. O., Shelton, C., et al. (2006) · Otology & Neurotology · doi:10.1097/01.mao.0000244368.70190.38 · Cited by 16
Cited by
Cochlear implants: A remarkable past and a brilliant future
Wilson, B. S., & Dorman, M. F. (2008) · Hearing Research · doi:10.1016/j.heares.2008.06.005 · Cited by 868
Self-citationTissue–electronics interfaces: from implantable devices to engineered tissues
Feiner, R., & Dvir, T. (2017) · Nature Reviews Materials · doi:10.1038/natrevmats.2017.76 · Cited by 595
Cochlear implantation outcomes in adults: A scoping review
Boisvert, I., Reis, M., Au, A., Cowan, R., & Dowell, R. C. (2020) · PLOS ONE · doi:10.1371/journal.pone.0232421 · Cited by 318
Artificial vision through neuronal stimulation
Fernandes, R. A. B., Diniz, B., Ribeiro, R., & Humayun, M. (2012) · Neuroscience Letters · doi:10.1016/j.neulet.2012.01.063 · Cited by 90
Optimization of return electrodes in neurostimulating arrays
Flores, T., Goetz, G., Lei, X., & Palanker, D. (2016) · Journal of Neural Engineering · doi:10.1088/1741-2560/13/3/036010 · Cited by 43
Metadata
- Authors
- Wilson, B. S.
- Venue
- The Journal of Rehabilitation Research and Development
- Published
- 2008-12-01
- Volume
- 45
- Issue
- 5
- Pages
- 695-730
- ISSN
- 0742-3241 (ISSN-L)
- 0748-7711
- OpenAlex
- W1984184977
- Cited by
- 396
- References
- 81
- FWCI
- 7.47
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.