Effect of flash glucose monitoring on glycemic control, hypoglycemia, diabetes-related distress, and resource utilization in the Association of British Clinical Diabetologists (ABCD) nationwide audit
Open accessAbstract
OBJECTIVE: The FreeStyle Libre (FSL) flash glucose-monitoring device was made available on the U.K. National Health Service (NHS) drug tariff in 2017. This study aims to explore the U.K. real-world experience of FSL and the impact on glycemic control, hypoglycemia, diabetes-related distress, and hospital admissions. RESEARCH DESIGN AND METHODS: Clinicians from 102 NHS hospitals in the U.K. submitted FSL user data, collected during routine clinical care, to a secure web-based tool held within the NHS N3 network. The t and Mann-Whitney U tests were used to compare the baseline and follow-up HbA1c and other baseline demographic characteristics. Linear regression analysis was used to identify predictors of change in HbA1c following the use of FSL. Within-person variations of HbA1c were calculated using . RESULTS: Data were available for 10,370 FSL users (97% with type 1 diabetes), age 38.0 (±18.8) years, 51% female, diabetes duration 16.0 (±49.9) years, and BMI of 25.2 (±16.5) kg/m2 (mean [±SD]). FSL users demonstrated a −5.2 mmol/mol change in HbA1c, reducing from 67.5 (±20.9) mmol/mol (8.3%) at baseline to 62.3 (±18.5) mmol/mol (7.8%) after 7.5 (interquartile range 3.4–7.8) months of follow-up (n = 3,182) (P < 0.0001). HbA1c reduction was greater in those with initial HbA1c ≥69.5 mmol/mol (>8.5%), reducing from 85.5 (±16.1) mmol/mol (10%) to 73.1 (±15.8) mmol/mol (8.8%) (P < 0.0001). The baseline Gold score (score for hypoglycemic unawareness) was 2.7 (±1.8) and reduced to 2.4 (±1.7) (P < 0.0001) at follow-up. A total of 53% of those with a Gold score of ≥4 at baseline had a score <4 at follow-up. FSL use was also associated with a reduction in diabetes distress (P < 0.0001). FSL use was associated with a significant reduction in paramedic callouts and hospital admissions due to hypoglycemia and hyperglycemia/diabetic ketoacidosis. CONCLUSIONS: We show that the use of FSL was associated with significantly improved glycemic control and hypoglycemia awareness and a reduction in hospital admissions.
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In adults with type 1 diabetes who wear intermittently scanned CGM, hypoglycemia improves.
“and hypoglycemia (41,43,75,78,79).”
From 7. Diabetes Technology: Standards of Care in Diabetes—2025 (2025) · cites this paper as [75]
Continuous glucose monitoring improves glycemic control and reduces the risk of severe and nonsevere hypoglycemia.
“Continuous glucose monitoring (CGM) has been shown to improve glycemic control and self-monitoring, as well as to reduce the risk of hypoglycemia.”
From Importance of FDA-integrated continuous glucose monitors to ensure accuracy of continuous glucose monitoring (2025) · cites this paper as [8]
CGM supports people with diabetes to optimize therapy, diet, and activity, facilitating improved HbA1c, increased time in target range 70-180 mg/dL, reduced time below range <70 mg/dL, and improved Glycemia Risk Index scores.
“In fact, CGM supports people with DM to optimize their therapy, diet, and activity, facilitating improved HbA1c, increased time in target range of 70 to 180 mg/dL, reduced time below range (<70 mg/dL), and improved Glycemia Risk Index scores.5-11”
From Importance of FDA-integrated continuous glucose monitors to ensure accuracy of continuous glucose monitoring (2025) · cites this paper as [8]
Publicly available accuracy data from observational and randomized clinical trials supporting some non-iCGM-approved entrants include small sample sizes and/or very few data points in the critical range of <70 mg/dL, more stable patients, and no glucose and insulin challenges, and data may not have been published in peer-reviewed journals.
“For example, publicly available accuracy data from both observational and randomized clinical trials supporting some non-iCGM-approved entrants include small sample sizes and/or very few data points in the critical range of <70 mg/dL, more stable patients, and no glucose and insulin challenges, and data may not have been published in peer-reviewed journals.8,11,20-24,35,36,39-48”
From Importance of FDA-integrated continuous glucose monitors to ensure accuracy of continuous glucose monitoring (2025) · cites this paper as [8]
Individuals on a variety of insulin treatment plans can benefit from CGM with improved glucose control, decreased hypoglycemia, and enhanced self-efficacy.
“Individuals on a variety of insulin treatment plans can benefit from CGM with improved glucose control, decreased hypoglycemia, and enhanced self-efficacy (Section 7, “Diabetes Technology”) (1).”
From 6. Glycemic Targets: <i>Standards of Care in Diabetes—2023</i> (2023) · cites this paper as [1]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Cites
Battelino, T., Danne, T., Bergenstal, R. M., Amiel, S. A., Beck, R., Biester, T., Bosi, E., Buckingham, B. A., Cefalu, W. T., Close, K. L., et al. (2019) · Diabetes Care · doi:10.2337/dci19-0028 · Cited by 4,032 · see citing works
Beck, R. W., Riddlesworth, T., Ruedy, K., Ahmann, A., Bergenstal, R., Haller, S., Kollman, C., Kruger, D., McGill, J. B., Polonsky, W., et al. (2017) · JAMA · doi:10.1001/jama.2016.19975 · Cited by 1,185 · cited 1× · see citing works
“The benefits include improvements 69 in glycaemic control and hypoglycaemia[1-4].”
BackgroundBolinder, J., Antuna, R., Geelhoed-Duijvestijn, P., Kröger, J., & Weitgasser, R. (2016) · The Lancet · doi:10.1016/s0140-6736(16)31535-5 · Cited by 893 · see citing works
Gold, A. E., Macleod, K. M., & Frier, B. M. (1994) · Diabetes Care · doi:10.2337/diacare.17.7.697 · Cited by 810 · see citing works
Haak, T., Hanaire, H., Ajjan, R., Hermanns, N., Riveline, J.-P., & Rayman, G. (2017) · Diabetes Therapy · doi:10.1007/s13300-016-0223-6 · Cited by 623 · see citing works
Heinemann, L., Freckmann, G., Ehrmann, D., Faber-Heinemann, G., Guerra, S., Waldenmaier, D., & Hermanns, N. (2018) · The Lancet · doi:10.1016/s0140-6736(18)30297-6 · Cited by 522 · see citing works
Development of a brief diabetes distress screening instrument
Fisher, L., Glasgow, R. E., Mullan, J. T., Skaff, M. M., & Polonsky, W. H. (2008) · The Annals of Family Medicine · doi:10.1370/afm.842 · Cited by 474 · cited 6× · see citing works
“We observed significant improvements in both componentsof theDDSscore(DDS2 instrument) in those who started on FSL.”
MethodInfluentialCharleer, S., De Block, C., Van Huffel, L., Broos, B., Fieuws, S., Nobels, F., Mathieu, C., & Gillard, P. (2020) · Diabetes Care · doi:10.2337/dc19-1610 · Cited by 261 · see citing works
Evans, M., Welsh, Z., Ells, S., & Seibold, A. (2020) · Diabetes Therapy · doi:10.1007/s13300-019-00720-0 · Cited by 185 · see citing works
Tyndall, V., Stimson, R. H., Zammitt, N. N., Ritchie, S. A., McKnight, J. A., Dover, A. R., & Gibb, F. W. (2019) · Diabetologia · doi:10.1007/s00125-019-4894-1 · Cited by 165 · see citing works
Virk, S. A., Donaghue, K. C., Cho, Y. H., Benitez-Aguirre, P., Hing, S., Pryke, A., Chan, A., & Craig, M. E. (2016) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jc.2015-3604 · Cited by 109 · see citing works
Campbell, F., Murphy, N., Stewart, C., Biester, T., & Kordonouri, O. (2018) · Pediatric Diabetes · doi:10.1111/pedi.12735 · Cited by 102 · see citing works
Penno, G., Solini, A., Zoppini, G., Orsi, E., Fondelli, C., Zerbini, G., Morano, S., Cavalot, F. L., Lamacchia, O., Trevisan, R., et al. (2013) · Cardiovascular Diabetology · doi:10.1186/1475-2840-12-98 · Cited by 68 · see citing works
Both High and Low HbA1c Predict Incident Heart Failure in Type 2 Diabetes Mellitus
Parry, H., Deshmukh, H., Levin, D., Zuydam, N. V., Elder, D. H. J., Morris, A. D., Struthers, A. D., Palmer, C. N. A., Doney, A. S. F., & Lang, C. C. (2015) · Circulation Heart Failure · doi:10.1161/circheartfailure.113.000920 · Cited by 62 · see citing works
Self-citationAlawadi, F., Rashid, F., Bashier, A. M., et al. (2019) · Diabetes Research and Clinical Practice · doi:10.1016/j.diabres.2019.03.015 · Cited by 38 · see citing works
Bilir, S. P., Hellmund, R., Wehler, E., Li, H., Munakata, J., & Lamotte, M. (2018) · touchREVIEWS in Endocrinology · doi:10.17925/ee.2018.14.2.73 · Cited by 34 · see citing works
Diagnostic Confusion? Repeat HbA1c for the Diagnosis of Diabetes
McDonald, T. J., & Warren, R. E. (2014) · Diabetes Care · doi:10.2337/dc14-0055 · Cited by 23 · see citing works
Fokkert, M. J., Damman, A., van Dijk, P. R., Edens, M. A., Abbes, S., Braakman, J. H., Slingerland, R. J., Dikkeschei, L. D., Dille, J., & Bilo, H. J. G. (2019) · International Journal of Endocrinology · doi:10.1155/2019/4649303 · Cited by 22 · see citing works
Moreno-Fernández, J., Pazos-Couselo, M., González‐Rodríguez, M., Rozas, P., Delgado‐Rodríguez, M., Aguirre, M., & López, J. M. G. (2018) · Endocrinología Diabetes y Nutrición · doi:10.1016/j.endinu.2018.04.003 · Cited by 21 · see citing works
Heinemann, L., Deiss, D., Hermanns, N., Graham, C., Kaltheuner, M., Liebl, A., & Price, D. A. (2015) · Journal of Diabetes Science and Technology · doi:10.1177/1932296815575999 · Cited by 19 · see citing works
Flagged first, then by citations
Cited by
Sorted by citations
6. Glycemic Targets: <i>Standards of Medical Care in Diabetes—2022</i>
American Diabetes Association Professional Practice Committee (2022) · Diabetes Care · doi:10.2337/dc22-s006 · Cited by 1,403 · see citing works
6. Glycemic Targets: <i>Standards of Care in Diabetes—2023</i>
ElSayed, N. A., Aleppo, G., Aroda, V. R., Bannuru, R. R., Brown, F. M., Bruemmer, D., Collins, B. S., Hilliard, M. E., Isaacs, D., Johnson, E. L., et al. (2023) · Diabetes Care · doi:10.2337/dc23-s006 · Cited by 684 · see citing works
6. Glycemic Goals and Hypoglycemia: Standards of Care in Diabetes—2025
American Diabetes Association Professional Practice Committee, ElSayed, N. A., McCoy, R. G., Aleppo, G., Balapattabi, K., Beverly, E. A., Briggs Early, K., Bruemmer, D., Echouffo-Tcheugui, J. B., Ekhlaspour, L., et al. (2025) · Diabetes Care · doi:10.2337/dc25-s006 · Cited by 440 · see citing works
7. Diabetes Technology: Standards of Care in Diabetes—2025
American Diabetes Association Professional Practice Committee, ElSayed, N. A., McCoy, R. G., Aleppo, G., Balapattabi, K., Beverly, E. A., Briggs Early, K., Bruemmer, D., Echouffo-Tcheugui, J. B., Ekhlaspour, L., et al. (2025) · Diabetes Care · doi:10.2337/dc25-s007 · Cited by 348 · see citing works
7. Diabetes Technology: <i>Standards of Care in Diabetes</i> — <i>2023</i>
ElSayed, N. A., Aleppo, G., Aroda, V. R., Bannuru, R. R., Brown, F. M., Bruemmer, D., Collins, B. S., Hilliard, M. E., Isaacs, D., Johnson, E. L., et al. (2023) · Diabetes Care · doi:10.2337/dc23-s007 · Cited by 301 · see citing works
7. Diabetes Technology: <i>Standards of Care in Diabetes—2024</i>
American Diabetes Association Professional Practice Committee, ElSayed, N. A., Aleppo, G., Bannuru, R. R., Bruemmer, D., Collins, B. S., Ekhlaspour, L., Hilliard, M. E., Johnson, E. L., Khunti, K., et al. (2024) · Diabetes Care · doi:10.2337/dc24-s007 · Cited by 281 · see citing works
7. Diabetes Technology: <i>Standards of Medical Care in Diabetes—2022</i>
American Diabetes Association Professional Practice Committee (2022) · Diabetes Care · doi:10.2337/dc22-s007 · Cited by 358 · see citing works
Choudhary, P., Kolassa, R., Keuthage, W., Kroeger, J., Thivolet, C., Evans, M., Ré, R., de Portu, S., Vorrink, L., Shin, J., et al. (2022) · The Lancet Diabetes & Endocrinology · doi:10.1016/s2213-8587(22)00212-1 · Cited by 204 · see citing works
Intermittently scanned continuous glucose monitoring for type 1 diabetes
Leelarathna, L., Evans, M. L., Neupane, S., Rayman, G., Lumley, S., Cranston, I., Narendran, P., Barnard-Kelly, K., Sutton, C. J., Elliott, R. A., et al. (2022) · New England Journal of Medicine · doi:10.1056/nejmoa2205650 · Cited by 174 · see citing works
Self-citation6. Glycemic Goals, Hypoglycemia, and Hyperglycemic Crises: Standards of Care in Diabetes-2026.
American Diabetes Association Professional Practice Committee for Diabetes*, Bajaj, M., McCoy, R. G., Balapattabi, K., Bannuru, R. R., Bellini, N. J., Bennett, A. K., Beverly, E. A., Briggs Early, K., ChallaSivaKanaka, S., et al. (2026) · Diabetes Care · doi:10.2337/dc26-s006 · Cited by 172 · see citing works
Speight, J., Choudhary, P., Wilmot, E. G., Hendrieckx, C., Forde, H., Cheung, W. Y., Crabtree, T., Millar, B., Traviss‐Turner, G., Hill, A., et al. (2023) · Diabetic Medicine · doi:10.1111/dme.14944 · Cited by 92 · see citing works
Self-citationRiveline, J.-P., Roussel, R., Vicaut, E., de Pouvourville, G., Detournay, B., Emery, C., Levrat-Guillen, F., & Guerci, B. (2022) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2022.0085 · Cited by 64 · see citing works
Nathanson, D., Svensson, A.-M., Miftaraj, M., Franzén, S., Bolinder, J., & Eeg-Olofsson, K. (2021) · Diabetologia · doi:10.1007/s00125-021-05437-z · Cited by 61 · see citing works
Amiel, S. A., Potts, L., Goldsmith, K., Jacob, P., Smith, E. L., Gonder-Frederick, L., Heller, S., Toschi, E., Brooks, A., Kariyawasam, D., et al. (2022) · Nature Communications · doi:10.1038/s41467-022-29488-x · Cited by 61 · see citing works
Pemberton, J. S., Wilmot, E. G., Barnard‐Kelly, K., Leelarathna, L., Oliver, N., Randell, T., Taplin, C. E., Choudhary, P., & Adolfsson, P. (2023) · Diabetes, Obesity and Metabolism · doi:10.1111/dom.14962 · Cited by 44 · see citing works
Self-citationPrabhu Navis, J., Leelarathna, L., Mubita, W., Urwin, A., Rutter, M. K., Schofield, J., & Thabit, H. (2021) · Acta Diabetologica · doi:10.1007/s00592-020-01614-5 · Cited by 39 · see citing works
Nørgaard, S. K., Mathiesen, E. R., Nørgaard, K., & Ringholm, L. (2021) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2021.0109 · Cited by 38 · see citing works
Klonoff, D. C., Gabbay, M., Moon, S. J., & Wilmot, E. G. (2025) · Journal of Diabetes Science and Technology · doi:10.1177/19322968241250357 · Cited by 36 · see citing works
Self-citationLameijer, A., Lommerde, N., Dunn, T. C., Fokkert, M. J., Edens, M. A., Kao, K., Xu, Y., Gans, R. O. B., Bilo, H. J. G., & van Dijk, P. R. (2021) · Diabetes Research and Clinical Practice · doi:10.1016/j.diabres.2021.108897 · Cited by 27 · see citing works
Beyond A1C: exploring continuous glucose monitoring metrics in managing diabetes
Friedman, J. G., Coyne, K., Aleppo, G., & Szmuilowicz, E. D. (2023) · Endocrine Connections · doi:10.1530/ec-23-0085 · Cited by 22 · see citing works
Rebound Hypoglycemia and Hyperglycemia in Type 1 Diabetes
Hansen, K. W., & Bibby, B. M. (2024) · Journal of Diabetes Science and Technology · doi:10.1177/19322968231168379 · Cited by 17 · see citing works
Harris, S., Cimino, S., Nguyen, Y., Szafranski, K., & Poon, Y. (2025) · Diabetes Therapy · doi:10.1007/s13300-024-01677-5 · Cited by 12 · see citing works
Ssemmondo, E., Shah, N., Newham, M., Rigby, A., Buckland, R., Deshmukh, H., & Sathyapalan, T. (2025) · Diabetes, Obesity and Metabolism · doi:10.1111/dom.16116 · Cited by 6 · see citing works
Self-citation
- Authors
- Deshmukh, H., Wilmot, E. G., Gregory, R., Barnes, D., Narendran, P., Saunders, S., Furlong, N., Kamaruddin, S., Banatwalla, R., Herring, R., Kilvert, A., Patmore, J., Walton, C., Ryder, R. E. J., & Sathyapalan, T.
- Affiliations
- University of Hull (GB)
- University Hospitals of Derby and Burton NHS Foundation Trust (GB)
- Leicester General Hospital (GB)
- Tunbridge Wells Hospital (GB)
- Queen Elizabeth Hospital Birmingham (GB)
- Warrington and Halton Teaching Hospitals NHS Foundation Trust (GB)
- Mersey and West Lancashire Teaching Hospitals NHS Trust (GB)
- Darlington Memorial Hospital (GB)
- St Peter's Hospital (GB)
- Royal Surrey County Hospital (GB)
- Northampton General Hospital (GB)
- Birmingham City Hospital (GB)
- Corresponding author
- Sathyapalan, Thozhukat
- ORCID
- Venue
- Diabetes Care
- Publisher
- American Diabetes Association
- Published
- 2020-07-15
- Volume
- 43
- Issue
- 9
- Pages
- 2153-2160
- ISSN
- 0149-5992 (ISSN-L)
- 1935-5548
- PMC
- PMC7440900
- OpenAlex
- W3043197730
- Cited by
- 175
- References
- 20
- Citations by year
- 2026: 10 · 2025: 19 · 2024: 33 · 2023: 35 · 2022: 51 · 2021: 22 · 2020: 5
- FWCI
- 21.31
- Type
- journal article
- Language
- en
- Open access
- bronze
- doi.org
- Locations
- Diabetes Care (publishedVersion)
- PubMed Central (publishedVersion)
- PubMed (publishedVersion)
- Repository@Nottingham (University of Nottingham) (publishedVersion)
- Repository@Hull (Worktribe) (University of Hull) (acceptedVersion, other-oa)
- Repository@Hull (Worktribe) (University of Hull) (submittedVersion, cc-by)
- Repository@Nottingham (University of Nottingham) (submittedVersion, cc-by)
- University of Birmingham Research Portal (University of Birmingham) (submittedVersion, other-oa)
- Funders
- Abbott Laboratories
- Topics
- Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Management and Research
- Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Management and Education
- Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Treatment and Management
- Keywords
- flash glucose monitoring, FreeStyle Libre, type 1 diabetes, glycemic control, HbA1c reduction, hypoglycemia, hypoglycemia unawareness, diabetes distress, hospitalization, resource utilization (health care), real-world evidence, National Health Service, patient-reported outcomes, diabetes self-management
- MeSH terms
- Psychological Distress, Glycemic Control, Adult, Blood Glucose, Diabetes Mellitus, Female, United Kingdom, Health Resources, Glycated Hemoglobin, Hospitalization, Humans, Hyperglycemia, Hypoglycemia, Hypoglycemic Agents, Male, Middle Aged, Patient Acceptance of Health Care, State Medicine, Stress, Psychological, Blood Glucose Self-Monitoring, Diabetic Ketoacidosis, Clinical Audit, Young Adult
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review