Atherosclerosis Inflammation Imaging with 18F-FDG PET: Carotid, Iliac, and Femoral Uptake Reproducibility, Quantification Methods, and Recommendations
Open accessThe DOI matches its Crossref record; 31 of the 31 references it cites were found in a registry or an index.
Abstract
UNLABELLED: Atherosclerosis imaging with 18F-FDG PET is useful for tracking inflammation within plaque and monitoring the response to drug therapy. Short-term reproducibility of this technique in peripheral artery disease has not been assessed, and the optimal method of 18F-FDG quantification is still debated. We imaged 20 patients with vascular disease using 18F-FDG PET twice, 14 d apart, and used these data to assess reproducibility measures and compare 2 methods of 18F-FDG uptake measurement. We also reviewed the literature on quantification methods to determine the optimal measures of arterial 18F-FDG uptake for future studies. METHODS: Twenty patients with vascular disease underwent PET/CT of the iliac, femoral, and carotid arteries 90 min after 18F-FDG administration. In 19 patients, repeat testing was performed at 2 wk. Coregistration and attenuation correction were performed with CT. Vessel 18F-FDG uptake was measured as both the mean and maximum blood-normalized standardized uptake value (SUV), known as the target-to-background ratio (TBR). We assessed interscan, interobserver, and intraobserver agreement. RESULTS: Nineteen patients completed both imaging sessions. The carotid and peripheral arteries all have excellent short-term reproducibility of the 18F-FDG signal, with intraclass correlation coefficients all greater than 0.8 for all measures of reproducibility. Both mean and maximum TBR measurements for quantifying 18F-FDG uptake are equally reproducible. 18F-FDG uptake was significantly higher in the carotid arteries than in both iliac and femoral vessels (P < 0.001 for both). CONCLUSION: We found that both mean and maximum TBR in the carotid, iliac, and femoral arteries were highly reproducible. We suggest the mean TBR be used for tracking systemic arterial therapies, whereas the maximum TBR is optimal for detecting and monitoring local, plaque-based therapy.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
Forming inferences about some intraclass correlation coefficients.
McGraw, K. O., & Wong, S. P. (1996) · Psychological Methods · doi:10.1037/1082-989x.1.1.30 · Cited by 6,903 · cited 1×
“ICCs (13) with 95% confidence intervals were calculated to test the interscan variability (1-way random effects model with absolute agreement), and also to assess interobserver (2-way mixed effects model with absolute agreement) and intraobserver agreement (1-way random effects model with absolute agreement), after th…”
MethodGrundy, S. M., Cleeman, J. I., Merz, C. N. B., Brewer, H. B., Clark, L. T., Hunninghake, D. B., Pasternak, R. C., Smith, S. C., & Stone, N. J. (2004) · Circulation · doi:10.1161/01.cir.0000133317.49796.0e · Cited by 6,902
Naghavi, M., Libby, P., Falk, E., Casscells, S. W., Litovsky, S., Rumberger, J., Badimon, J. J., Stefanadis, C., Moreno, P., Pasterkamp, G., et al. (2003) · Circulation · doi:10.1161/01.cir.0000087481.55887.c9 · Cited by 2,668
Self-citationGreenland, P. (2004) · JAMA · doi:10.1001/jama.291.2.210 · Cited by 1,829
Applying the right statistics: analyses of measurement studies
Bland, J. M., & Altman, D. G. (2003) · Ultrasound in Obstetrics & Gynecology · doi:10.1002/uog.122 · Cited by 1,311
Rudd, J. H. F., Warburton, E. A., Fryer, T. D., Jones, H. A., Clark, J. C., Antoun, N., Johnström, P., Davenport, A. P., Kirkpatrick, P. J., Arch, B. N., et al. (2002) · Circulation · doi:10.1161/01.cir.0000020548.60110.76 · Cited by 1,226
Self-citationTawakol, A., Migrino, R. Q., Bashian, G. G., Bedri, S., Vermylen, D., Cury, R. C., Yates, D., LaMuraglia, G. M., Furie, K., Houser, S., et al. (2006) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2006.05.076 · Cited by 915
Kooi, M. E., Cappendijk, V. C., Cleutjens, K. B. J. M., Kessels, A. G. H., Kitslaar, P. J. E. H. M., Borgers, M., Frederik, P. M., Daemen, M. J. A. P., & van Engelshoven, J. M. A. (2003) · Circulation · doi:10.1161/01.cir.0000068315.98705.cc · Cited by 798
Analytic 3D image reconstruction using all detected events
Kinahan, P. E., & Rogers, J. G. (1989) · IEEE Transactions on Nuclear Science · doi:10.1109/23.34585 · Cited by 767
Cited by
Inflammation in Atherosclerosis
Libby, P., Ridker, P. M., & Hansson, G. K. (2009) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2009.09.009 · Cited by 2,228
Writing Committee Members, Greenland, P., Alpert, J. S., Beller, G. A., Benjamin, E. J., Budoff, M. J., Fayad, Z. A., Foster, E., Hlatky, M. A., Hodgson, J. M., et al. (2010) · Circulation · doi:10.1161/cir.0b013e3182051b4c · Cited by 1,873
Self-citation2010 ACCF/AHA Guideline for Assessment of Cardiovascular Risk in Asymptomatic Adults
Greenland, P., Alpert, J. S., Beller, G. A., Benjamin, E. J., Budoff, M. J., Fayad, Z. A., Foster, E., Hlatky, M. A., Hodgson, J. M., Kushner, F. G., et al. (2010) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2010.09.001 · Cited by 1,324
Self-citationInflammation in Atherosclerosis: Transition From Theory to Practice
Libby, P., Okamoto, Y., Rocha, V. Z., & Folco, E. (2010) · Circulation Journal · doi:10.1253/circj.cj-09-0706 · Cited by 799
Fayad, Z. A., Mani, V., Woodward, M., Kallend, D., Abt, M., Burgess, T., Fuster, V., Ballantyne, C. M., Stein, E. A., Tardif, J.-C., et al. (2011) · The Lancet · doi:10.1016/s0140-6736(11)61383-4 · Cited by 538
Self-citationWriting group, Slart, R. H. J. A., Reviewer group, Cardiovascular, M. O. E., Inflammation, M. O. E. I. &., Members of Committees, S. C., Members of Council, P. I. G., Members of, A. S. N. C., & EANM Committee Coordinator (2018) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-018-3973-8 · Cited by 503
Coronary Arterial 18F-Sodium Fluoride Uptake
Dweck, M. R., Chow, M. W. L., Joshi, N. V., Williams, M. C., Jones, C., Fletcher, A. M., Richardson, H., White, A., McKillop, G., van Beek, E. J. R., et al. (2012) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2011.12.037 · Cited by 488
Self-citationPhotoacoustic imaging and characterization of the microvasculature
Hu, S., & Wang, L. V. (2010) · Journal of Biomedical Optics · doi:10.1117/1.3281673 · Cited by 427
Contemporary carotid imaging: from degree of stenosis to plaque vulnerability
Brinjikji, W., Huston, J., Rabinstein, A. A., Kim, G.-M., Lerman, A., & Lanzino, G. (2016) · Journal of Neurosurgery · doi:10.3171/2015.1.jns142452 · Cited by 401
Raunig, D. L., McShane, L. M., Pennello, G., Gatsonis, C., Carson, P. L., Voyvodic, J. T., Wahl, R. L., Kurland, B. F., Schwarz, A. J., Gönen, M., et al. (2015) · Statistical Methods in Medical Research · doi:10.1177/0962280214537344 · Cited by 394
PET imaging of inflammation in atherosclerosis
Tarkin, J. M., Joshi, F. R., & Rudd, J. H. F. (2014) · Nature Reviews Cardiology · doi:10.1038/nrcardio.2014.80 · Cited by 386
Self-citationRominger, A., Saam, T., Wolpers, S., Cyran, C. C., Schmidt, M., Foerster, S., Nikolaou, K., Reiser, M. F., Bartenstein, P., & Hacker, M. (2009) · Journal of Nuclear Medicine · doi:10.2967/jnumed.109.065151 · Cited by 362
Dweck, M. R., Jones, C., Joshi, N. V., Fletcher, A. M., Richardson, H., White, A., Marsden, M., Pessotto, R., Clark, J. C., Wallace, W. A., et al. (2012) · Circulation · doi:10.1161/circulationaha.111.051052 · Cited by 337
Self-citationFigueroa, A. L., Abdelbaky, A., Truong, Q. A., Corsini, E., MacNabb, M. H., Lavender, Z. R., Lawler, M. A., Grinspoon, S. K., Brady, T. J., Nasir, K., et al. (2013) · JACC: Cardiovascular Imaging · doi:10.1016/j.jcmg.2013.08.006 · Cited by 336
Feasibility of FDG Imaging of the Coronary Arteries
Rogers, I. S., Nasir, K., Figueroa, A. L., Cury, R. C., Hoffmann, U., Vermylen, D. A., Brady, T. J., & Tawakol, A. (2010) · JACC: Cardiovascular Imaging · doi:10.1016/j.jcmg.2010.01.004 · Cited by 305
Gaemperli, O., Shalhoub, J., Owen, D. R. J., Lamare, F., Johansson, S., Fouladi, N., Davies, A. H., Rimoldi, O. E., & Camici, P. G. (2012) · European Heart Journal · doi:10.1093/eurheartj/ehr367 · Cited by 267
on behalf of the Cardiovascular Committee of the European Association of Nuclear Medicine (EANM), Bucerius, J., Hyafil, F., Verberne, H. J., Slart, R. H. J. A., Lindner, O., Sciagra, R., Agostini, D., Übleis, C., Gimelli, A., et al. (2016) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-015-3259-3 · Cited by 257
Imaging Atherosclerotic Plaque Inflammation by Fluorodeoxyglucose With Positron Emission Tomography
Rudd, J. H. F., Narula, J., Strauss, H. W., Virmani, R., Machac, J., Klimas, M., Tahara, N., Fuster, V., Warburton, E. A., Fayad, Z. A., et al. (2010) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2009.12.061 · Cited by 236
Self-citationMultimodality Cardiovascular Molecular Imaging, Part I
Sinusas, A. J., Bengel, F., Nahrendorf, M., Epstein, F. H., Wu, J. C., Villanueva, F. S., Fayad, Z. A., & Gropler, R. J. (2008) · Circulation: Cardiovascular Imaging · doi:10.1161/circimaging.108.824359 · Cited by 175
Self-citationLobatto, M. E., Fayad, Z. A., Silvera, S., Vucic, E., Calcagno, C., Mani, V., Dickson, S. D., Nicolay, K., Banciu, M., Schiffelers, R. M., et al. (2010) · Molecular Pharmaceutics · doi:10.1021/mp100309y · Cited by 170
“These scans provide quantifiable information about the level of inflammation present in the abdominal aorta (20).”
BackgroundSelf-citationRominger, A., Saam, T., Vogl, E., Übleis, C., la Fougère, C., Förster, S., Haug, A., Cumming, P., Reiser, M. F., Nikolaou, K., et al. (2010) · Journal of Nuclear Medicine · doi:10.2967/jnumed.109.070672 · Cited by 159
“uptake in the LAD in all 70 of our patients, with excellent intra- and interreader reproducibility for the TBR values, comparable to those obtained earlier for 18F-FDG uptake measurements in peripheral vessels (20).”
ResultPugliese, F., Gaemperli, O., Kinderlerer, A. R., Lamare, F., Shalhoub, J., Davies, A. H., Rimoldi, O. E., Mason, J. C., & Camici, P. G. (2010) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2010.02.063 · Cited by 158
Metadata
- Authors
- Rudd, J. H. F., Myers, K. S., Bansilal, S., Machac, J., Pinto, C. A., Tong, C., Rafique, A., Hargeaves, R., Farkouh, M., Fuster, V., & Fayad, Z. A.
- Venue
- Journal of Nuclear Medicine
- Publisher
- Society of Nuclear Medicine
- Published
- 2008-05-15
- Volume
- 49
- Issue
- 6
- Pages
- 871-878
- ISSN
- 0161-5505 (ISSN-L)
- 2159-662X
- OpenAlex
- W2061876167
- Cited by
- 444
- References
- 31
- FWCI
- 36.73
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.