Coupling between neuronal activity and microcirculation: Implications for functional brain imaging
Open accessThe DOI matches its Crossref record; 24 of the 24 references it cites were found in a registry or an index.
Abstract
In the neocortex, neurons with similar response properties are often clustered together in column-like structures, giving rise to what has become known as functional architecture-the mapping of various stimulus feature dimensions onto the cortical sheet. At least partially, we owe this finding to the availability of several functional brain imaging techniques, both post-mortem and in-vivo, which have become available over the last two generations, revolutionizing neuroscience by yielding information about the spatial organization of active neurons in the brain. Here, we focus on how our understanding of such functional architecture is linked to the development of those functional imaging methodologies, especially to those that image neuronal activity indirectly, through metabolic or haemodynamic signals, rather than directly through measurement of electrical activity. Some of those approaches allow exploring functional architecture at higher spatial resolution than others. In particular, optical imaging of intrinsic signals reaches the striking detail of approximately 50 mum, and, together with other methodologies, it has allowed characterizing the metabolic and haemodynamic responses induced by sensory-evoked neuronal activity. Here, we review those findings about the spatio-temporal characteristics of neurovascular coupling and discuss their implications for functional brain imaging, including position emission tomography, and non-invasive neuroimaging techniques, such as funtional magnetic resonance imaging, applicable also to the human brain.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Brain magnetic resonance imaging with contrast dependent on blood oxygenation.
Ogawa, S., Lee, T. M., Kay, A. R., & Tank, D. W. (1990) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.87.24.9868 · Cited by 6,483 · cited 2×
“Currently available techniques are PET (Fox and Raichle, 1984, 1986; Mintun et al., 1989), optical imaging of intrinsic signals (Grinvald et al., 1986; Frostig et al. 1990), and functional magnetic resonance imaging (fMRI) (Ogawa et al., 1990, 1992; Bandettini et al., 1992; Kwong et al., 1992).”
BackgroundMethodJöbsis, F. F. (1977) · Science · doi:10.1126/science.929199 · Cited by 3,899
Ogawa, S., Tank, D. W., Menon, R., Ellermann, J. M., Kim, S. G., Merkle, H., & Ugurbil, K. (1992) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.89.13.5951 · Cited by 3,681
Pellerin, L., & Magistretti, P. J. (1994) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.91.22.10625 · Cited by 2,927 · cited 4×
“, Hu and Wilson, 1997), the controversy regarding these issues is not yet resolved (Chih and Roberts Jr, 2003; Pellerin and Magistretti, 1994; for a review, see Schurr, 2006).”
BackgroundInfluentialFox, P. T., & Raichle, M. E. (1986) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.83.4.1140 · Cited by 2,056 · cited 11×
“This latter shortcoming can be partially overcome if the PET version (Reivich et al., 1979) of the 2DG method is used.”
MethodResultInfluentialTime course EPI of human brain function during task activation
Bandettini, P. A., Wong, E. C., Hinks, R. S., Tikofsky, R. S., & Hyde, J. S. (1992) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910250220 · Cited by 1,935 · cited 2×
“1990), and functional magnetic resonance imaging (fMRI) (Ogawa et al., 1990, 1992; Bandettini et al., 1992; Kwong et al., 1992).”
MethodFunctional mapping of the human visual cortex by magnetic resonance imaging
Belliveau, J. W., Kennedy, D. N., McKinstry, R. C., Buchbinder, B. R., Weisskoff, R. M., Cohen, M. S., Vevea, J. M., Brady, T. J., & Rosen, B. R. (1991) · Science · doi:10.1126/science.1948051 · Cited by 1,883
Nonoxidative Glucose Consumption During Focal Physiologic Neural Activity
Fox, P. T., Raichle, M. E., Mintun, M. A., & Dence, C. (1988) · Science · doi:10.1126/science.3260686 · Cited by 1,796 · cited 2×
“…1997) with the results of their PET scans (Fox et al., 1986, 1988) when their data indicated a substantial mismatch between a large, activity-dependent regional increase in glucose consumption and only a small increase in regionally utilized oxygen (30–50% versus 5%: Fox et al., 1986, 1988).”
BackgroundResultDynamics of blood flow and oxygenation changes during brain activation: the Balloon model
Buxton, R. B., Wong, E. C., & Frank, L. R. (1998) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910390602 · Cited by 1,665
Logothetis, N. K., & Wandell, B. A. (2004) · Annual Review of Physiology · doi:10.1146/annurev.physiol.66.082602.092845 · Cited by 1,568
Cited by
Ferrari, M., & Quaresima, V. (2012) · NeuroImage · doi:10.1016/j.neuroimage.2012.03.049 · Cited by 2,274
“The precise neuronal origin of the hemodynamic responses measured by fNIRS, fMRI and other techniques is still relatively unknown, despite its importance (for review: Figley and Stroman, 2011; Vanzetta and Grinvald, 2008).”
Hamilton, N. B. (2010) · Frontiers in Neuroenergetics · doi:10.3389/fnene.2010.00005 · Cited by 513
Daulatzai, M. A. (2017) · Journal of Neuroscience Research · doi:10.1002/jnr.23777 · Cited by 429
Ma, Y., Shaik, M. A., Kim, S. H., Kozberg, M. G., Thibodeaux, D. N., Zhao, H. T., Yu, H., & Hillman, E. M. C. (2016) · Philosophical Transactions of the Royal Society B: Biological Sciences · doi:10.1098/rstb.2015.0360 · Cited by 335
Anesthesia and the Quantitative Evaluation of Neurovascular Coupling
Masamoto, K., & Kanno, I. (2012) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1038/jcbfm.2012.50 · Cited by 273
Kaiser, V., Bauernfeind, G., Kreilinger, A., Kaufmann, T., Kübler, A., Neuper, C., & Müller-Putz, G. R. (2014) · NeuroImage · doi:10.1016/j.neuroimage.2013.04.097 · Cited by 192
Vanni, M. P., & Murphy, T. H. (2014) · The Journal of Neuroscience · doi:10.1523/jneurosci.1818-14.2014 · Cited by 170
Spatiotemporal precision and hemodynamic mechanism of optical point spreads in alert primates
Sirotin, Y. B., Hillman, E. M. C., Bordier, C., & Das, A. (2009) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0905509106 · Cited by 121
“Discrepancies between rodent and earlier monkey results had been attributed to species differences (35, 36).”
Metadata
- Authors
- Vanzetta, I., & Grinvald, A.
- Venue
- HFSP Journal
- Publisher
- Informa UK Limited
- Published
- 2008-04
- Volume
- 2
- Issue
- 2
- Pages
- 79-98
- ISSN
- 1955-205X (ISSN-L)
- 1955-2068
- OpenAlex
- W2019230113
- Cited by
- 84
- References
- 24
- FWCI
- 4.06
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.