The DOI matches its Crossref record; 48 of the 48 references it cites were found in a registry or an index.
Literature Review on Needs of Upper Limb Prosthesis Users
Open accessAbstract
The loss of one hand can significantly affect the level of autonomy and the capability of performing daily living, working and social activities. The current prosthetic solutions contribute in a poor way to overcome these problems due to limitations in the interfaces adopted for controlling the prosthesis and to the lack of force or tactile feedback, thus limiting hand grasp capabilities. This paper presents a literature review on needs analysis of upper limb prosthesis users, and points out the main critical aspects of the current prosthetic solutions, in terms of users satisfaction and activities of daily living they would like to perform with the prosthetic device. The ultimate goal is to provide design inputs in the prosthetic field and, contemporary, increase user satisfaction rates and reduce device abandonment. A list of requirements for upper limb prostheses is proposed, grounded on the performed analysis on user needs. It wants to (i) provide guidelines for improving the level of acceptability and usefulness of the prosthesis, by accounting for hand functional and technical aspects; (ii) propose a control architecture of PNS-based prosthetic systems able to satisfy the analyzed user wishes; (iii) provide hints for improving the quality of the methods (e.g., questionnaires) adopted for understanding the user satisfaction with their prostheses.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Estimating the Prevalence of Limb Loss in the United States: 2005 to 2050
Ziegler-Graham, K., MacKenzie, E. J., Ephraim, P. L., Travison, T. G., & Brookmeyer, R. (2008) · Archives of Physical Medicine and Rehabilitation · doi:10.1016/j.apmr.2007.11.005 · Cited by 2,816
Upper limb prosthesis use and abandonment: A survey of the last 25 years
Biddiss, E. A., & Chau, T. T. (2007) · Prosthetics & Orthotics International · doi:10.1080/03093640600994581 · Cited by 1,111
Restoring natural sensory feedback in real-time bidirectional hand prostheses
Raspopovic, S., Capogrosso, M., Petrini, F. M., Bonizzato, M., Rigosa, J., Di Pino, G., Carpaneto, J., Controzzi, M., Boretius, T., Fernandez, E., et al. (2014) · Science Translational Medicine · doi:10.1126/scitranslmed.3006820 · Cited by 1,001
Self-citationNavarro, X., Krueger, T. B., Lago, N., Micera, S., Stieglitz, T., & Dario, P. (2005) · Journal of the Peripheral Nervous System · doi:10.1111/j.1085-9489.2005.10303.x · Cited by 845
A neural interface provides long-term stable natural touch perception
Tan, D. W., Schiefer, M. A., Keith, M. W., Anderson, J. R., Tyler, J., & Tyler, D. J. (2014) · Science Translational Medicine · doi:10.1126/scitranslmed.3008669 · Cited by 751
Mechanical design and performance specifications of anthropomorphic prosthetic hands: A review
Belter, J. T., Segil, J. L., Dollar, A. M., & Weir, R. F. (2013) · The Journal of Rehabilitation Research and Development · doi:10.1682/jrrd.2011.10.0188 · Cited by 716
Direct neural sensory feedback and control of a prosthetic arm
Dhillon, G. S., & Horch, K. W. (2005) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2005.856072 · Cited by 573
Consumer design priorities for upper limb prosthetics
Biddiss, E., Beaton, D., & Chau, T. (2007) · Disability and Rehabilitation: Assistive Technology · doi:10.1080/17483100701714733 · Cited by 519
Epidemiologic Overview of Individuals with Upper-Limb Loss and Their Reported Research Priorities
Atkins, D. J., Heard, D. C. Y., & Donovan, W. H. (1996) · JPO Journal of Prosthetics and Orthotics · doi:10.1097/00008526-199600810-00003 · Cited by 508
Control of upper limb prostheses: terminology and proportional myoelectric control-a review
Fougner, A., Stavdahl, Ø., Kyberd, P. J., Losier, Y. G., & Parker, P. A. (2012) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2012.2196711 · Cited by 495
Ortiz-Catalan, M., Håkansson, B., & Brånemark, R. (2014) · Science Translational Medicine · doi:10.1126/scitranslmed.3008933 · Cited by 484
Myoelectric forearm prostheses: State of the art from a user-centered perspective
Peerdeman, B., Boere, D., Witteveen, H., Huis in `tVeld, R., Hermens, H., Stramigioli, S., Rietman, H., Veltink, P., & Misra, S. (2011) · The Journal of Rehabilitation Research and Development · doi:10.1682/jrrd.2010.08.0161 · Cited by 469
Sensory feedback in upper limb prosthetics
Antfolk, C., D’Alonzo, M., Rosén, B., Lundborg, G., Sebelius, F., & Cipriani, C. (2013) · Expert Review of Medical Devices · doi:10.1586/erd.12.68 · Cited by 466
Double nerve intraneural interface implant on a human amputee for robotic hand control
Rossini, P. M., Micera, S., Benvenuto, A., Carpaneto, J., Cavallo, G., Citi, L., Cipriani, C., Denaro, L., Denaro, V., Di Pino, G., et al. (2010) · Clinical Neurophysiology · doi:10.1016/j.clinph.2010.01.001 · Cited by 396
Self-citationDhillon, G. S., Lawrence, S. M., Hutchinson, D. T., & Horch, K. W. (2004) · The Journal of Hand Surgery · doi:10.1016/j.jhsa.2004.02.006 · Cited by 354 · cited 4×
“…2013), ultrasound imaging (Gonzales and Castellini, 2013), force myography (FMG; Wininger et al., 2008)] or else in an invasive way [by means of Implantable Myoelectric Sensors (IMES; Pasquina et al., 2015), neural interfaces (Dhillon et al., 2004)] from the Peripheral or Central Nervous System.”
BackgroundMethodInfluentialProsthetic usage in major upper extremity amputations
Wright, T. W., Hagen, A. D., & Wood, M. B. (1995) · The Journal of Hand Surgery · doi:10.1016/s0363-5023(05)80278-3 · Cited by 266
Results of an internet survey of myoelectric prosthetic hand users
Pylatiuk, C., Schulz, S., & Döderlein, L. (2007) · Prosthetics & Orthotics International · doi:10.1080/03093640601061265 · Cited by 257
Castellini, C., Artemiadis, P., Wininger, M., Ajoudani, A., Alimusaj, M., Bicchi, A., Caputo, B., Craelius, W., Dosen, S., Englehart, K., et al. (2014) · Frontiers in Neurorobotics · doi:10.3389/fnbot.2014.00022 · Cited by 221
Pasquina, P. F., Evangelista, M., Carvalho, A. J., Lockhart, J., Griffin, S., Nanos, G., McKay, P., Hansen, M., Ipsen, D., Vandersea, J., et al. (2015) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2014.07.016 · Cited by 205
Bionic prosthetic hands: A review of present technology and future aspirations
Clement, R. G. E., Bugler, K. E., & Oliver, C. W. (2011) · The Surgeon · doi:10.1016/j.surge.2011.06.001 · Cited by 189
Schultz, A. E., & Kuiken, T. A. (2011) · PM&R · doi:10.1016/j.pmrj.2010.06.016 · Cited by 186 · cited 2×
“The control system drives the prosthesis actuators starting from the amputee intentions of movement decoded by means of the muscular or neural interfacing system (Schultz and Kuiken, 2011).”
BackgroundMethodAtzori, M., & Müller, H. (2015) · Frontiers in Systems Neuroscience · doi:10.3389/fnsys.2015.00162 · Cited by 183
Surveying the interest of individuals with upper limb loss in novel prosthetic control techniques
Engdahl, S. M., Christie, B. P., Kelly, B., Davis, A., Chestek, C. A., & Gates, D. H. (2015) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-015-0044-2 · Cited by 179
Applications of sensory feedback in motorized upper extremity prosthesis: a review
Schofield, J. S., Evans, K. R., Carey, J. P., & Hebert, J. S. (2014) · Expert Review of Medical Devices · doi:10.1586/17434440.2014.929496 · Cited by 178
Improved Myoelectric Prosthesis Control Using Targeted Reinnervation Surgery: A Case Series
Miller, L. A., Stubblefield, K. A., Lipschutz, R. D., Lock, B. A., & Kuiken, T. (2008) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2007.911817 · Cited by 177
Myoelectric Prostheses: state of the art
Scott, R. N., & Parker, P. A. (1988) · Journal of Medical Engineering & Technology · doi:10.3109/03091908809030173 · Cited by 171
Force Myography to Control Robotic Upper Extremity Prostheses: A Feasibility Study
Cho, E., Chen, R. J., Merhi, L.-K., Xiao, Z. G., Pousett, B. M., & Menon, C. (2016) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2016.00018 · Cited by 166
A Survey on Activities of Daily Living and Occupations of Upper Extremity Amputees
Jang, C. H., Yang, H. S., Yang, H. E., Lee, S. Y., Kwon, J. W., Yun, B. D., Choi, J. Y., Kim, S. N., & Jeong, H. W. (2011) · Annals of Rehabilitation Medicine · doi:10.5535/arm.2011.35.6.907 · Cited by 165
Improved Myoelectric Prosthesis Control Accomplished Using Multiple Nerve Transfers
Hijjawi, J. B., Kuiken, T., Lipschutz, R. D., Miller, L. A., Stubblefield, K. A., & Dumanian, G. A. (2006) · Plastic & Reconstructive Surgery · doi:10.1097/01.prs.0000242487.62487.fb · Cited by 163
Polasek, K. H., Hoyen, H. A., Keith, M. W., Kirsch, R. F., & Tyler, D. J. (2009) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2009.2032603 · Cited by 142
Pressure signature of forearm as predictor of grip force
Wininger, M., Kim, N., & Craelius, W. (2008) · The Journal of Rehabilitation Research and Development · doi:10.1682/jrrd.2007.11.0187 · Cited by 142
Østlie, K., Lesjø, I. M., Franklin, R. J., Garfelt, B., Skjeldal, O. H., & Magnus, P. M. (2012) · Disability and Rehabilitation Assistive Technology · doi:10.3109/17483107.2011.653296 · Cited by 135
Consumer concerns and the functional value of prostheses to upper limb amputees
Kejlaa, G. H. (1993) · Prosthetics and Orthotics International · doi:10.3109/03093649309164376 · Cited by 134
Li, N., Yang, D., Jiang, L., Liu, H., & Cai, H. (2012) · Journal of Bionic Engineering · doi:10.1016/s1672-6529(11)60095-4 · Cited by 119
Lindner, H. Y. N., Nätterlund, B., & Hermansson, L. (2010) · Prosthetics and Orthotics International · doi:10.3109/03093641003776976 · Cited by 115
Survey of upper limb prosthesis users in Sweden, the United Kingdom and Canada
Kyberd, P., & Hill, W. (2011) · Prosthetics and Orthotics International · doi:10.1177/0309364611409099 · Cited by 113
Prosthetic cost projections for servicemembers with major limb loss from Vietnam and OIF/OEF
Blough, D. K., Hubbard, S., McFarland, L. V., Smith, D. G., Gambel, J. M., & Reiber, G. E. (2010) · The Journal of Rehabilitation Research and Development · doi:10.1682/jrrd.2009.04.0037 · Cited by 110
Impact of Michelangelo prosthetic hand: Findings from a crossover longitudinal study
Luchetti, M., Cutti, A. G., Verni, G., Sacchetti, R., & Rossi, N. C. F. (2015) · The Journal of Rehabilitation Research and Development · doi:10.1682/jrrd.2014.11.0283 · Cited by 105
Self-citationGonzález, D., & Castellini, C. (2013) · Frontiers in Neurorobotics · doi:10.3389/fnbot.2013.00017 · Cited by 103
Survey of Upper-Extremity Prosthesis Users in Sweden and the United Kingdom
Kyberd, P., Wartenberg, C., Sandsjö, L., Jönsson, S., Gow, D., Frid, J., Almström, C., & Sperling, L. (2007) · JPO Journal of Prosthetics and Orthotics · doi:10.1097/jpo.0b013e3180459df6 · Cited by 100
A field evaluation of arm prostheses for unilateral amputees
van Lunteren, A., van Lunteren-Gerritsen, G. H. M., STASSEN, H. G., & Zuithoff, M. J. (1983) · Prosthetics and Orthotics International · doi:10.3109/03093648309166586 · Cited by 83
Fraser, C. M. (1998) · Prosthetics and Orthotics International · doi:10.3109/03093649809164486 · Cited by 63
Electrically powered prostheses for the adult with an upper limb amputation
Heger, H., Millstein, S. G., & Hunter, G. (1985) · Journal of Bone and Joint Surgery - British Volume · doi:10.1302/0301-620x.67b2.3980541 · Cited by 59
Human Activity Recognition - Using Sensor Data of Smartphones and Smartwatches
Sefen, B., Baumbach, S., Dengel, A. R., & Abdennadher, S. (2016) · International Conference on Agents and Artificial Intelligence (ICAART) · doi:10.5220/0005816004880493 · Cited by 49
Design, control, and sensory feedback of externally powered hand prostheses: a literature review
Cloutier, A., & Yang, J. (2013) · Critical Reviews in Biomedical Engineering · doi:10.1615/critrevbiomedeng.2013007887 · Cited by 36
Myoelectric control of upper limb prosthesis: current status, challenges and recent advances
NING, J., & Farina, D. (2014) · Frontiers in Neuroengineering · doi:10.3389/conf.fneng.2014.11.00004 · Cited by 30
Bouffard, J., Vincent, C., Boulianne, É., Lajoie, S., & Mercier, C. (2011) · JPO Journal of Prosthetics and Orthotics · doi:10.1097/jpo.0b013e318240d171 · Cited by 25
A Survey of Users of Upper Limb Prostheses
Fraser, C. (1993) · British Journal of Occupational Therapy · doi:10.1177/030802269305600503 · Cited by 19
Research works printed but not linked: 6
- Davalli, 2009, Le protesi di Arto
- Dohnalek, 2013, Human activity recognition on raw sensors data via sparse approximation, 700
- Frontera, 2014, Fondamenti di Medicina Fisica e Riabilitativa
- Fumero, 2001, Organi artificiali, 341
- Heckathorne, 1994, Expert analysis of the TIRR National Upper limb Amputee Database
- Weaver, 1988, Comparison of myoelectric and conventional prostheses for adolescent amputees, Br. J. Occup. Ther., 42, 87, 10.5014/ajot.42.2.87 · doi:10.5014/ajot.42.2.87
Cited by
A soft neuroprosthetic hand providing simultaneous myoelectric control and tactile feedback
Gu, G., Zhang, N., Xu, H., Lin, S., Yu, Y., Chai, G., Ge, L., Yang, H., Shao, Q., Sheng, X., et al. (2021) · Nature Biomedical Engineering · doi:10.1038/s41551-021-00767-0 · Cited by 431
George, J. A., Kluger, D. T., Davis, T. S., Wendelken, S. M., Okorokova, E. V., He, Q., Duncan, C. C., Hutchinson, D. T., Thumser, Z. C., Beckler, D. T., et al. (2019) · Science Robotics · doi:10.1126/scirobotics.aax2352 · Cited by 388
Parajuli, N., Sreenivasan, N., Bifulco, P., Cesarelli, M., Savino, S., Niola, V., Esposito, D., Hamilton, T. J., Naik, G. R., Gunawardana, U., et al. (2019) · Sensors · doi:10.3390/s19204596 · Cited by 332
Toward higher-performance bionic limbs for wider clinical use
Farina, D., Vujaklija, I., Brånemark, R., Bull, A. M. J., Dietl, H., Graimann, B., Hargrove, L. J., Hoffmann, K.-P., Huang, H., Ingvarsson, T., et al. (2021) · Nature Biomedical Engineering · doi:10.1038/s41551-021-00732-x · Cited by 263
A Review of Non-Invasive Sensory Feedback Methods for Transradial Prosthetic Hands
Stephens-Fripp, B., Alici, G., & Mutlu, R. (2018) · IEEE Access · doi:10.1109/access.2018.2791583 · Cited by 210
Metadata
- Authors
- Cordella, F., Ciancio, A. L., Sacchetti, R., Davalli, A., Cutti, A. G., Guglielmelli, E., & Zollo, L.
- Venue
- Frontiers in Neuroscience
- Publisher
- Frontiers Media SA
- Published
- 2016-05-12
- Volume
- 10
- Pages
- 209-209
- ISSN
- 1662-453X (ISSN-L)
- OpenAlex
- W2376290865
- Cited by
- 752
- References
- 48
- FWCI
- 23.41
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.