Poly(3,4-ethylene dioxythiophene) (PEDOT) as a micro-neural interface material for electrostimulation
Open accessThe DOI matches its Crossref record; 39 of the 39 references it cites were found in a registry or an index.
Abstract
Chronic microstimulation-based devices are being investigated to treat conditions such as blindness, deafness, pain, paralysis, and epilepsy. Small-area electrodes are desired to achieve high selectivity. However, a major trade-off with electrode miniaturization is an increase in impedance and charge density requirements. Thus, the development of novel materials with lower interfacial impedance and enhanced charge storage capacity is essential for the development of micro-neural interface-based neuroprostheses. In this report, we study the use of conducting polymer poly(3,4-ethylenedioxythiophene) (PEDOT) as a neural interface material for microstimulation of small-area iridium electrodes on silicon-substrate arrays. Characterized by electrochemical impedance spectroscopy, electrodeposition of PEDOT results in lower interfacial impedance at physiologically relevant frequencies, with the 1 kHz impedance magnitude being 23.3 +/- 0.7 kOmega, compared to 113.6 +/- 3.5 kOmega for iridium oxide (IrOx) on 177 mum(2) sites. Further, PEDOT exhibits enhanced charge storage capacity at 75.6 +/- 5.4 mC/cm(2) compared to 28.8 +/- 0.3 mC/cm(2) for IrOx, characterized by cyclic voltammetry (50 mV/s). These improvements at the electrode interface were corroborated by observation of the voltage excursions that result from constant current pulsing. The PEDOT coatings provide both a lower amplitude voltage and a more ohmic representation of the applied current compared to IrOx. During repetitive pulsing, PEDOT-coated electrodes show stable performance and little change in electrical properties, even at relatively high current densities which cause IrOx instability. These findings support the potential of PEDOT coatings as a micro-neural interface material for electrostimulation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Neural Stimulation and Recording Electrodes
Cogan, S. F. (2008) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.10.061807.160518 · Cited by 2,243 · cited 2×
“Poly(3,4-ethylenedioxythiophene) (PEDOT) coatings on neural electrodes have been reported to display charge injection limits similar to IrOx at 2.3–3.6 mC/cm2 (Cui and Zhou, 2007; Nyberg et al., 2007) and much higher than IrOx at approximately 15 mC/cm2 (Cogan, 2008).”
InfluentialElectrical stimulation of excitable tissue: design of efficacious and safe protocols
Merrill, D. R., Bikson, M., & Jefferys, J. G. R. (2005) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2004.10.020 · Cited by 2,078 · cited 2×
“Cathodal-fi rst, charge-balanced, biphasic current pulses are frequently used for effective and safe stimulation of neural tissue (Brummer and Turner, 1975; Lilly et al., 1955; Merrill et al., 2005).”
Conducting polymers in biomedical engineering
Guimard, N. K., Gomez, N., & Schmidt, C. E. (2007) · Progress in Polymer Science · doi:10.1016/j.progpolymsci.2007.05.012 · Cited by 1,599 · cited 1×
“Many studies have suggested the conductive polymer PEDOT as a microelectrode coating for neural stimulation due to its desirable electrical properties (Abidian and Martin, 2008; Cui and Martin, 2003; Guimard et al., 2007), electrochemical stability (Kros et al.”
Conducting‐Polymer Nanotubes for Controlled Drug Release
Abidian, M. R., Kim, D. ‐., & Martin, D. C. (2006) · Advanced Materials · doi:10.1002/adma.200501726 · Cited by 869 · cited 3×
“Many studies have suggested the conductive polymer PEDOT as a microelectrode coating for neural stimulation due to its desirable electrical properties (Abidian and Martin, 2008; Cui and Martin, 2003; Guimard et al., 2007), electrochemical stability (Kros et al., 2005) and ability for biomolecule immobilization (Abidia…”
Schmidt, E. M., Bak, M. J., Hambrecht, F. T., Kufta, C. V., O'Rourke, D. K., & Vallabhanath, P. (1996) · Brain · doi:10.1093/brain/119.2.507 · Cited by 672 · cited 2×
“, 2003), visual (Bak et al., 1990; Bradley et al., 2005; Normann et al., 1999; Schmidt et al., 1996; Weiland et al., 2005), somatosensory (Butovas and Schwarz, 2007; Romo and Salinas, 2001), motor control (Mushahwar et al.”
Cui, X., & Martin, D. C. (2003) · Sensors and Actuators B: Chemical · doi:10.1016/s0925-4005(02)00448-3 · Cited by 573 · cited 6×
“A slight loss in Qcap occurred, but since there was no change in impedance, this is most likely due to rearrangement of the PEDOT and PSS structure after sweeping the voltage during the CV measurement ( Cui and Martin, 2003 ).”
InfluentialA model of safe levels for electrical stimulation
Shannon, R. V. (1992) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.126616 · Cited by 526 · cited 2×
“where Q is charge per phase in µC, A is the electrode surface area in cm2, and k is a constant of 1.7 (Shannon, 1992).”
InfluentialRichardson-Burns, S. M., Hendricks, J. L., Foster, B., Povlich, L. K., Kim, D.-H., & Martin, D. C. (2007) · Biomaterials · doi:10.1016/j.biomaterials.2006.11.026 · Cited by 503
A neural interface for a cortical vision prosthesis
Normann, R. A., Maynard, E. M., Rousche, P. J., & Warren, D. J. (1999) · Vision Research · doi:10.1016/s0042-6989(99)00040-1 · Cited by 409 · cited 2×
“, 2003), visual (Bak et al., 1990; Bradley et al., 2005; Normann et al., 1999; Schmidt et al., 1996; Weiland et al., 2005), somatosensory (Butovas and Schwarz, 2007; Romo and Salinas, 2001), motor control (Mushahwar et al.”
In vitro electrical properties for iridium oxide versus titanium nitride stimulating electrodes
Weiland, J. D., Anderson, D. J., & Humayun, M. S. (2002) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2002.805487 · Cited by 382 · cited 1×
“, 2005) and TiN (Weiland et al., 2002), and currently is considered the best interface material for neural stimulation.”
Cited by
An Integrated Brain-Machine Interface Platform With Thousands of Channels
Musk, E., & Neuralink (2019) · Journal of Medical Internet Research · doi:10.2196/16194 · Cited by 1,206
Soft and elastic hydrogel-based microelectronics for localized low-voltage neuromodulation
Liu, Y., Liu, J., Chen, S., Lei, T., Kim, Y., Niu, S., Wang, H., Wang, X., Foudeh, A. M., Tok, J. B.-H., et al. (2019) · Nature Biomedical Engineering · doi:10.1038/s41551-018-0335-6 · Cited by 811
Highly Conducting and Stretchable Double‐Network Hydrogel for Soft Bioelectronics
Li, G., Huang, K., Deng, J., Guo, M., Cai, M., Zhang, Y., & Guo, C. F. (2022) · Advanced Materials · doi:10.1002/adma.202200261 · Cited by 443
A Materials Roadmap to Functional Neural Interface Design
Wellman, S. M., Eles, J. R., Ludwig, K. A., Seymour, J. P., Michelson, N. J., McFadden, W. E., Vazquez, A. L., & Kozai, T. D. Y. (2018) · Advanced Functional Materials · doi:10.1002/adfm.201701269 · Cited by 389
Morphing electronics enable neuromodulation in growing tissue
Liu, Y., Li, J., Song, S., Kang, J., Tsao, Y., Chen, S., Mottini, V., McConnell, K., Xu, W., Zheng, Y.-Q., et al. (2020) · Nature Biotechnology · doi:10.1038/s41587-020-0495-2 · Cited by 325
In Vitro and In Vivo Evaluation of PEDOT Microelectrodes for Neural Stimulation and Recording
Venkatraman, S., Hendricks, J., King, Z. A., Sereno, A. J., Richardson-Burns, S., Martin, D., & Carmena, J. M. (2011) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2011.2109399 · Cited by 319
“This agrees with the dramatic increase in charge storage capacity of PEDOT when measured using fast CV, reported in [ 22 ].”
BackgroundMethodResultInfluentialSelf-citationNeural Stimulation and Recording with Bidirectional, Soft Carbon Nanotube Fiber Microelectrodes
Vitale, F., Summerson, S. R., Aazhang, B., Kemere, C., & Pasquali, M. (2015) · ACS Nano · doi:10.1021/acsnano.5b01060 · Cited by 311
Ludwig, K. A., Langhals, N. B., Joseph, M. D., Richardson-Burns, S. M., Hendricks, J. L., & Kipke, D. R. (2011) · Journal of Neural Engineering · doi:10.1088/1741-2560/8/1/014001 · Cited by 283
Self-citationPires, F., Ferreira, Q., Rodrigues, C. A. V., Morgado, J., & Ferreira, F. C. (2015) · Biochimica et Biophysica Acta (BBA) - General Subjects · doi:10.1016/j.bbagen.2015.01.020 · Cited by 276
Conducting polymer-hydrogels for medical electrode applications
Green, R. A., Baek, S., Poole-Warren, L. A., & Martens, P. J. (2010) · Science and Technology of Advanced Materials · doi:10.1088/1468-6996/11/1/014107 · Cited by 268
Lewis, P. M., Ackland, H. M., Lowery, A. J., & Rosenfeld, J. V. (2015) · Brain Research · doi:10.1016/j.brainres.2014.11.020 · Cited by 228
Flexible Neural Electrode Array Based-on Porous Graphene for Cortical Microstimulation and Sensing
Lu, Y., Lyu, H., Richardson, A. G., Lucas, T. H., & Kuzum, D. (2016) · Scientific Reports · doi:10.1038/srep33526 · Cited by 213
Graphene in the design and engineering of next‐generation neural interfaces
Kostarelos, K., Vincent, M., Hebert, C., & Garrido, J. A. (2017) · Advanced Materials · doi:10.1002/adma.201700909 · Cited by 206
Substrate dependent stability of conducting polymer coatings on medical electrodes
Green, R. A., Hassarati, R. T., Bouchinet, L., Lee, C. S., Cheong, G. L. M., Yu, J. F., Dodds, C. W., Suaning, G. J., Poole-Warren, L. A., & Lovell, N. H. (2012) · Biomaterials · doi:10.1016/j.biomaterials.2012.05.017 · Cited by 205
High‐Performance Vertical Organic Electrochemical Transistors
Donahue, M. J., Williamson, A., Strakosas, X., Friedlein, J. T., McLeod, R. R., Gleskova, H., & Malliaras, G. G. (2018) · Advanced Materials · doi:10.1002/adma.201705031 · Cited by 179
Implantable neurotechnologies: a review of micro- and nanoelectrodes for neural recording
Patil, A. C., & Thakor, N. V. (2016) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-015-1430-4 · Cited by 175
Stretchable Polymeric Multielectrode Array for Conformal Neural Interfacing
Guo, L., Ma, M., Zhang, N., Langer, R., & Anderson, D. G. (2014) · Advanced Materials · doi:10.1002/adma.201304140 · Cited by 128
Kolarcik, C. L., Catt, K., Rost, E., Albrecht, I. N., Bourbeau, D., Du, Z., Kozai, T. D. Y., Luo, X., Weber, D. J., & Tracy Cui, X. (2015) · Journal of Neural Engineering · doi:10.1088/1741-2560/12/1/016008 · Cited by 126
“They exhibit both fast and high charge delivery capacities as a result of the high ionic conductivity and large electroactive surface area [26] resulting in low impedance and more effective charge transfer [27].”
BackgroundYin, P., Liu, Y., Xiao, L., & Zhang, C. (2021) · Polymers · doi:10.3390/polym13162834 · Cited by 42
Niederhoffer, T., Vanhoestenberghe, A., & Lancashire, H. T. (2023) · Journal of Neural Engineering · doi:10.1088/1741-2552/acb084 · Cited by 38
“At identical deposition charge density, fast sweep rate (1 V s−1) yielded a 2.4 times larger CSC than slow sweep rate (50 mV s−1), with a wide square-shaped voltammogram compared to well-defined peaks on the slow sweep rate voltammogram (Wilks et al 2009).”
BackgroundInfluential
Metadata
- Authors
- Wilks, S.
- Venue
- Frontiers in Neuroengineering
- Publisher
- Frontiers Media SA
- Published
- 2009
- Volume
- 2
- Pages
- 7-7
- ISSN
- 1662-6443 (ISSN-L)
- OpenAlex
- W2053660789
- Cited by
- 188
- References
- 39
- FWCI
- 2.89
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.