Microextraction Techniques with Deep Eutectic Solvents
Open accessThe DOI matches its Crossref record; 132 of the 136 references it cites were found in a registry or an index; 21 of the 99 sources its claims cite were checked for support.
Abstract
In this review, the ever-increasing use of deep eutectic solvents (DES) in microextraction techniques will be discussed, focusing on the reasons needed to replace conventional extraction techniques with greener approaches that follow the principles of green analytical chemistry. The properties of DES will be discussed, pinpointing their exceptional performance and analytical parameters, justifying their current extensive scientific interest. Finally, a variety of applications for commonly used microextraction techniques will be reported.
Overview
CoChat Summary
TL;DR
This review discusses the increasing use of deep eutectic solvents (DES) in microextraction techniques as greener alternatives in analytical sample preparation. It summarizes DES synthesis/properties and surveys applications across solid-phase and liquid-phase microextraction, reporting high recoveries and low detection limits.
Key findings
- DES are presented as greener alternatives to ionic liquids and organic solvents because of easier and cheaper production, lower reported toxicity, and tunable properties, though the review notes DES are not yet commercially available and the number of available HBAs/HBDs remains limited.
- In solid-phase microextraction applications, reported recoveries include 102.6 ± 4.1% for ginseng compounds using sucrose/L-proline/glycerol at 1:4:9, and 95.38% for sulfamerazine with DES-graphene versus 26.98% with graphene alone.
- In liquid-phase microextraction, reported LODs include 0.008 ng g−1 for Pb and 0.0002 ng g−1 for Cd in edible oils; DLLME examples report LODs such as 0.39–3.1 ng/mL for pesticides and 0.02–0.05 μg/mL for sulfonamides, with many recoveries around 90–105%.
- The review states that most DES applications concern liquid-phase microextraction rather than solid-phase microextraction, because DES are liquid and simpler to use as extraction phases than as supporting solid adsorbents.
Methods
- Narrative review; no primary experimental design. It synthesizes literature on DES synthesis, properties, and their use in analytical microextraction.
- Covers solid-phase extraction, solid-phase microextraction, stir bar sorptive extraction, and liquid-phase microextraction variants including hollow-fiber LPME, single-drop microextraction, and dispersive liquid–liquid microextraction.
- Main analysis is qualitative synthesis of reported analytical parameters—recoveries, LODs/LOQs, linear ranges—across environmental, food, biological, pharmaceutical, and traditional Chinese medicine samples.
Limitations
- The paper states that DES toxicity needs further investigation, the number of HBAs and HBDs is quite limited, and DES are not commercially available yet, limiting routine use in industrial or certified laboratories.
- Evident from the text: as a review, it relies on cited studies and does not provide new experimental validation or standardized comparisons; reported performance values come from heterogeneous methods, matrices, and detection systems, so direct comparison is limited.
Model-written summary. Check it against the paper before relying on it.
Integrity signals
Registry
Cites
Statistics
Figures
Verification
Claims the paper makes
19 Valid · 2 Not valid · 70 Not checked · 4 Own results and interpretations
The cited sources support only part of this claim — read each source’s verdict below.
In the paper
“Nevertheless, analytes and interferents could coelute from the SPE sorbent because of the limited selectivity of conventional solid sorbents, such as silica-based, carbon-based, and clay-based resins [41,42].”
§ Microextraction Techniques with Deep Eutectic Solvents > 3. Microextraction Techniques Using DES > 3.1. Solid Phase Microextraction
What the sources say
- Partly supportedcites [41] 2020, Hydrophobic deep eutectic solvents in microextraction techniques—A review, Microchem. J. sourceExperimental — accuracy not yet measured
Section 3.6 (Solid phase extraction; page not provided) says analytes and interferences could coelute because conventional solid sorbents have limited selectivity. It does not identify silica-based, carbon-based, and clay-based resins as the sorbents responsible, so the specific examples are not supported by this source. (LLM, conf=0.86)
- Not checked — no full text of the sourcecites [42] Keçili, R., Büyüktiryaki, S., Dolak, I., and Hussain, C.M. (2020). The use of magnetic nanoparticles in sample preparation devices and tools. Handbook of Nanomaterials in Analytical Chemistry, Elsevier. source
hedgedstates a possible cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Partly supported
The cited sources support only part of this claim — read each source’s verdict below.
In the paper
“Both intra-day and inter-day yielded recoveries of the five analytes between 80–98% [55].”
§ Microextraction Techniques with Deep Eutectic Solvents > 3. Microextraction Techniques Using DES > 3.1. Solid Phase Microextraction
What the sources say
- Partly supportedcites [55] Ma, W., and Row, K.H. (2020). Solid-Phase Extraction of Catechins from Green Tea with Deep Eutectic Solvent Immobilized Magnetic Molybdenum Disulfide Molecularly Imprinted Polymer. Molecules, 25. sourceExperimental — accuracy not yet measured
Section 2.4, Validation and Applications (page unavailable), reports testing five catechins in fortified samples on the same and different days. It gives intra-day and inter-day relative standard deviations, but the available passage does not give 80–98% recoveries for those tests. Its separate recovery figure concerns reuse of the adsorbent, not intra-day or inter-day recovery. (LLM, conf=0.82)
plain- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: unclear — It is unclear whether the paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Partly supported
Every source the paper cites for this claim was checked and supports it.
In the paper
“Out of the four DESs, the one that was the most compatible for this work was ChCl:Resorcinol (1:2 molar ratio).”
§ Microextraction Techniques with Deep Eutectic Solvents > 3. Microextraction Techniques Using DES > 3.1. Solid Phase Microextraction
What the sources say
- Supportedcites [71] Zarei, 2017, Deep eutectic solvent based magnetic nanofluid in the development of stir bar sorptive dispersive microextraction: An efficient hyphenated sample preparation for ultra-trace nitroaromatic explosives extraction in wastewater, J. Sep. Sci. source
Section 2.4 states that the authors prepared four DESs, each with ChCl and a hydrogen-bond donor at a 1:2 molar ratio. Section 3.2 identifies resorcinol–ChCl as the DES used under the optimized conditions for extracting nitroaromatic compounds from water samples. (LLM, conf=0.88)
plain- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Supported
Every source the paper cites for this claim was checked and supports it.
In the paper
“The adsorption capacity of gallic acid on HMICS with DES was 10.13 mg/g, 2.36 times higher than that of NICS (non-imprinted chitosan) without DES [63].”
§ Microextraction Techniques with Deep Eutectic Solvents > 3. Microextraction Techniques Using DES > 3.1. Solid Phase Microextraction
What the sources say
- Supportedcites [63] Li, G., and Rwo, K.H. (2019). Hydrophilic molecularly imprinted chitosan based on deep eutectic solvents for the enrichment of gallic acid in red ginseng tea. Polymers (Basel), 11. source
Section 3.1 (Adsorption Properties) reports a gallic-acid adsorption capacity of 10.13 mg·g−1 for HMICS with DES, approximately 2.36 times the 4.30 mg·g−1 capacity of NICS without DES. Section 2.3.2 identifies NICS as non-imprinted chitosan. (LLM, conf=0.95)
plainstates a cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Supported
The cited sources support only part of this claim — read each source’s verdict below.
In the paper
“Patent Blue V analysis in syrup and water samples by UV-VIS [82]”
§ Microextraction Techniques with Deep Eutectic Solvents > 3. Microextraction Techniques Using DES > 3.2. Liquid Phase Microextraction
What the sources say
- Partly supportedcites [82] Kanberoglu, 2019, Developing a new and simple ultrasound-assisted emulsification liquid phase microextraction method built upon deep eutectic solvents for Patent Blue V in syrup and water samples, Microchem. J. sourceExperimental — accuracy not yet measured
Section 2.4 says ChCl–phenol solvents at both 1:3 and 1:4 were prepared and tested. Section 3.2 says 1:4 was selected and used thereafter; section 3.8 reports UV–Vis analysis of syrup and water samples. The copy does not support saying that 1:3 was applied to those samples. (LLM, conf=0.90)
plain- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: unclear — It is unclear whether the paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Partly supported
35 more claims · 3 with their cited sources checked
Create a free account to see all 95 claims and every source verdict.
- Probably not a substantial claim. 10
- It may state two separate claims as one. 45
- The quote only partly states this claim. 4
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“Moreover, some DESs are cost-effective, have low toxicity, and are biodegradable, making them attractive alternatives to traditional organic solvents in microextraction [18,19,20].”
From A Novel DLLME Method Involving a Solidifying Hydrophobic Deep Eutectic Solvent Using Hydrophilic Deep Eutectic Solvent as the Dispersant for the Determination of Polychlorinated Biphenyls in Water Samples (2024) · cites this paper as [19]
Experimental — accuracy not yet measuredThe cited source says what the claim attributes to it.
In the citing paper
“There are four main types of deep eutectic solvents: type I, where a metal chloride is combined with a quaternary salt, type II, where a hydrated metal chloride is merged with a quaternary salt, type III, where an HBD is put together with an HBA quaternary salt, and type IV, where an organic HBD compound reacts with a metal chloride [2,33].”
From Applications of Deep Eutectic Solvents in Sample Preparation and Extraction of Organic Molecules (2022) · cites this paper as [2]
In the citing paper
“The use of DESs in SFOD improves extraction efficiency and selectivity while also reducing environmental and health concerns associated with hazardous organic solvents [30].”
From Eco-Friendly Deep Eutectic Solvent-Based Extraction Technologies: A Comprehensive Review of Principles, Applications, and Comparative Insights (2026) · cites this paper as [30]
In the citing paper
“The properties that need to be considered when using DES and/or NADES are density, acidity, conductivity, viscosity, volatility, the melting and freezing point, and surface tension. Additionally, the toxicity, cost, thermal stability, and biodegradability should not be passed over [2,37].”
From Applications of Deep Eutectic Solvents in Sample Preparation and Extraction of Organic Molecules (2022) · cites this paper as [2]
Citations
Cites
Deep Eutectic Solvents (DESs) and Their Applications
Smith, E. L., Abbott, A. P., & Ryder, K. S. (2014) · Chemical Reviews · doi:10.1021/cr300162p · Cited by 7,378
Abbott, A. P., Capper, G., Davies, D. L., Rasheed, R. K., & Tambyrajah, V. (2003) · Chemical Communications · doi:10.1039/b210714g · Cited by 5,738 · cited 1×
“The first two types are used to synthesize hydrophilic DESs, whilst the other two for hydrophobic DESs [20,34].”
MethodSolid phase microextraction with thermal desorption using fused silica optical fibers
Arthur, C. L., & Pawliszyn, J. (1990) · Analytical Chemistry · doi:10.1021/ac00218a019 · Cited by 4,997 · cited 1×
“Solid phase microextraction (SPME) is a sample preparation technique developed by Pawliszyn in 1990, where a fiber, with a small diameter, coated with a sorbent, is placed in aqueous solutions, so as to extract the analytes [64].”
MethodAbbott, A. P., Boothby, D., Capper, G., Davies, D. L., & Rasheed, R. K. (2004) · Journal of the American Chemical Society · doi:10.1021/ja048266j · Cited by 4,340 · cited 1×
“Typically, ambient temperature molten salts have been formed by mixing quaternary ammonium salts, a hydrogen bond acceptor (HBA) with metal salts [32,33].”
BackgroundIonic Liquids--Solvents of the Future?
Rogers, R. D., & Seddon, K. R. (2003) · Science · doi:10.1126/science.1090313 · Cited by 4,130
Determination of organic compounds in water using dispersive liquid–liquid microextraction
Rezaee, M., Assadi, Y., Milani Hosseini, M.-R., Aghaee, E., Ahmadi, F., & Berijani, S. (2006) · Journal of Chromatography A · doi:10.1016/j.chroma.2006.03.007 · Cited by 3,402
Baltussen, E., Sandra, P., David, F., & Cramers, C. (1999) · Journal of Microcolumn Separations · doi:10.1002/(sici)1520-667x(1999)11:10<737::aid-mcs7>3.0.co;2-4 · Cited by 1,502 · cited 1×
“The former is more suitable for stirring sample volumes from 10–50 mL, and the latter is suited for volumes up to 250 mL [69].”
BackgroundSolvent Microextraction into a Single Drop
Jeannot, M. A., & Cantwell, F. F. (1996) · Analytical Chemistry · doi:10.1021/ac960042z · Cited by 1,282 · cited 1×
“In addition, a comparison of the introduced technique with SPME showed that they were comparable in terms of precision, sensitivity, and extraction time, although SPME was considered less complicated [93].”
MethodPedersen-Bjergaard, S., & Rasmussen, K. E. (1999) · Analytical Chemistry · doi:10.1021/ac990055n · Cited by 1,245 · cited 1×
“Hollow fiber LPME (HF-LPME) was firstly introduced by Pedersen-Bjergaard and Rasmussen as a liquid–liquid–liquid microextraction technique, prior to capillary electrophoresis for the preconcentration of methamphetamine in biological samples [85].”
MethodArmenta, S., Garrigues, S., & de la Guardia, M. (2008) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2008.05.003 · Cited by 1,213
Abbott, A. P., Capper, G., Davies, D. L., Munro, H. L., Rasheed, R. K., & Tambyrajah, V. (2001) · Chemical Communications · doi:10.1039/b106357j · Cited by 1,100 · cited 1×
“The charge delocalization occurring through hydrogen bonding between, for instance a halide ion and the hydrogen-donor moiety, is responsible for the decrease in the melting point of the mixture, in relation to the melting points of the individual components [19,20].”
BackgroundFlorindo, C., Oliveira, F. S., Rebelo, L. P. N., Fernandes, A. M., & Marrucho, I. M. (2014) · ACS Sustainable Chemistry & Engineering · doi:10.1021/sc500439w · Cited by 977 · cited 1×
“conducted an extensive investigation for three different DESs and their binary mixtures with polyethylene glycol (PEG 400) as co-solvent, through MD simulations analysis, while showing that PEG 400 can make a strong hydrogen bond with DESs [39].”
MethodEvolution of dispersive liquid–liquid microextraction method
Rezaee, M., Yamini, Y., & Faraji, M. (2010) · Journal of Chromatography A · doi:10.1016/j.chroma.2009.11.088 · Cited by 971
Use of ionic liquids as ‘green’ solvents for extractions
Zhao, H., Xia, S., & Ma, P. (2005) · Journal of Chemical Technology & Biotechnology · doi:10.1002/jctb.1333 · Cited by 873
Design of Sustainable Chemical ProductsThe Example of Ionic Liquids
Ranke, J., Stolte, S., Störmann, R., Arning, J., & Jastorff, B. (2007) · Chemical Reviews · doi:10.1021/cr050942s · Cited by 794
Sarafraz-Yazdi, A., & Amiri, A. (2010) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2009.10.003 · Cited by 779 · cited 1×
“In addition to the tendency of reducing the use of solvents and the produced waste, in recent years, there have been new applications for specific techniques that include green solvents, such as ionic liquids and deep eutectic solvents, in order to substitute toxic organic reagents and minimize the cost [75,76].”
BackgroundExtraction techniques with deep eutectic solvents
Cunha, S. C., & Fernandes, J. O. (2018) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2018.05.001 · Cited by 760
Toxicity and biodegradability of imidazolium ionic liquids
Romero, A., Santos, A., Tojo, J., & Rodríguez, A. (2008) · Journal of Hazardous Materials · doi:10.1016/j.jhazmat.2007.10.079 · Cited by 713 · cited 1×
“Nevertheless, the problems with their biodegradability, toxicity, stability, and the expensive synthesis make them less than perfect solvents [17].”
BackgroundHe, Y., & Lee, H. K. (1997) · Analytical Chemistry · doi:10.1021/ac970242q · Cited by 681 · cited 13×
“Other approaches to this technique are thin-film SPME (TF-SPME), in-tube SPME, hollow fiber SPME (HF-SPME), and in-needle SPME [43].”
BackgroundInfluentialWierucka, M., & Biziuk, M. (2014) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2014.04.007 · Cited by 594 · cited 1×
“In MSPE, magnetic nanoparticles are utilized, such as magnetite (Fe3O4) and maghemite (γ-Fe2O3), and afterwards, they are embedded in a suitable coating of inorganic substances, mainly in graphene [44].”
MethodHydrophobic deep eutectic solvents in microextraction techniques–A review
Makoś, P., Słupek, E., & Gębicki, J. (2020) · Microchemical Journal · doi:10.1016/j.microc.2019.104384 · Cited by 469 · cited 2×
“Nevertheless, analytes and interferents could coelute from the SPE sorbent because of the limited selectivity of conventional solid sorbents, such as silica-based, carbon-based, and clay-based resins [41,42].”
BackgroundLord, H., & Pawliszyn, J. (2000) · Journal of Chromatography A · doi:10.1016/s0021-9673(00)00836-0 · Cited by 468 · cited 1×
“Moreover, microextraction techniques, for example solid phase microextraction (SPME) and liquid phase microextraction (LPME), which will be discussed below, are considered to be green extraction techniques, owing to the use of very small quantities of solvents of the extraction phase in relation to the volume of the s…”
MethodIonic liquids and deep eutectic mixtures: Sustainable solvents for extraction processes
Pena‐Pereira, F., & Namieśnik, J. (2014) · ChemSusChem · doi:10.1002/cssc.201301192 · Cited by 432 · cited 1×
“In this regard, remarkable advances towards the replacement of volatile organic solvents have been achieved by a group of organic salts with melting points below 100 ◦C, generally referred to as ionic liquids (ILs) [16].”
BackgroundThe role of green extraction techniques in Green Analytical Chemistry
Armenta, S., Garrigues, S., & de la Guardia, M. (2015) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2014.12.011 · Cited by 329 · cited 1×
“Greener approaches to extraction techniques include more inexpensive, quicker, and environmentally safe practices in environmental, clinical, and food analysis [5].”
MethodA green deep eutectic solvent-based aqueous two-phase system for protein extracting
Xu, K., Wang, Y., Huang, Y., Li, N., & Wen, Q. (2015) · Analytica Chimica Acta · doi:10.1016/j.aca.2015.01.026 · Cited by 302
Farajzadeh, M. A., & Mogaddam, M. R. A. (2012) · Analytica Chimica Acta · doi:10.1016/j.aca.2012.03.031 · Cited by 292
Green extraction techniques in green analytical chemistry
Armenta, S., Garrigues, S., Esteve-Turrillas, F. A., & de la Guardia, M. (2019) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2019.03.016 · Cited by 280 · cited 1×
“Anastas in 1998, the main concern of which was to create environmentally friendly analytical techniques, especially extraction techniques [4].”
BackgroundDeep eutectic solvents are not only effective extractants
Shishov, A., Pochivalov, A., Nugbienyo, L., Andruch, V., & Bulatov, A. (2020) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2020.115956 · Cited by 278
Beyond dispersive liquid–liquid microextraction
Leong, M.-I., Fuh, M.-R., & Huang, S.-D. (2014) · Journal of Chromatography A · doi:10.1016/j.chroma.2014.02.021 · Cited by 241
Liquid Droplet. A Renewable Gas Sampling Interface
Liu, S., & Dasgupta, P. K. (1995) · Analytical Chemistry · doi:10.1021/ac00109a023 · Cited by 235
Fifty years of solid-phase extraction in water analysis – historical development and overview
Liška, I. (2000) · Journal of Chromatography A · doi:10.1016/s0021-9673(99)01144-9 · Cited by 221 · cited 1×
“SPE was firstly introduced in the 1950s [40], and it uses appropriate sorbents so as to isolate the target compounds from the sample.”
MethodTailoring and recycling of deep eutectic solvents as sustainable and efficient extraction media
Jeong, K. M., Lee, M. S., Nam, M. W., Zhao, J., Jin, Y., Lee, D.-K., Kwon, S. W., Jeong, J. H., & Lee, J. (2015) · Journal of Chromatography A · doi:10.1016/j.chroma.2015.10.083 · Cited by 219 · cited 1×
“7%) for every recurring recycle, indicating that the DES can be recycled and reused at least three times, so as to achieve a high level of extraction yields [47].”
BackgroundIonic liquid-based aqueous two-phase systems and their applications in green separation processes
Li, Z., Pei, Y., Wang, H., Fan, J., & Wang, J. (2010) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2010.07.014 · Cited by 206
Developments in hollow fiber based liquid-phase microextraction: principles and applications
Ghambarian, M., Yamini, Y., & Esrafili, A. (2012) · Microchimica Acta · doi:10.1007/s00604-012-0773-x · Cited by 195 · cited 1×
“[86] HF-LPME normally uses hydrophobic organic solvents as extraction solvents, however, DES-based methods can be used as an additional novelty within the concept of GAC.”
MethodTang, S., Qi, T., Ansah, P. D., Nalouzebi Fouemina, J. C., Shen, W., Basheer, C., & Lee, H. K. (2018) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2018.09.016 · Cited by 195 · cited 9×
“Moreover, there are recent studies of different analytes extracted by HS-SDME.”
MethodInfluentialUtilization of deep eutectic solvents in dispersive liquid-liquid micro-extraction
Li, G., & Row, K. H. (2019) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2019.115651 · Cited by 186
Karimi, M., Dadfarnia, S., Shabani, A. M. H., Tamaddon, F., & Azadi, D. (2015) · Talanta · doi:10.1016/j.talanta.2015.07.021 · Cited by 182 · cited 1×
“Additionally, the method was applied to edible oils, such as olive oil, sunflower oil, sesame oil, and soybean oil, with good recoveries (95–104%) from spiked samples [77].”
MethodYilmaz, E., & Soylak, M. (2016) · Talanta · doi:10.1016/j.talanta.2016.08.001 · Cited by 177 · cited 2×
“The main combination chosen as an extraction solvent is ChCl-phenol at molar ratios of 1:3 and 1:4, applied to different samples for the determination of several analytes such as: cobalt Co (II) in a pharmaceutical supplement and tea samples by a microsample injection system, coupled with flame atomic absorption spect…”
MethodArain, M. B., Yilmaz, E., & Soylak, M. (2016) · Journal of Molecular Liquids · doi:10.1016/j.molliq.2016.10.005 · Cited by 168 · cited 2×
“The main combination chosen as an extraction solvent is ChCl-phenol at molar ratios of 1:3 and 1:4, applied to different samples for the determination of several analytes such as: cobalt Co (II) in a pharmaceutical supplement and tea samples by a microsample injection system, coupled with flame atomic absorption spect…”
MethodChemistry: It's not easy being green
Sanderson, K. (2011) · Nature · doi:10.1038/469018a · Cited by 168
Faraji, M. (2019) · Journal of Chromatography A · doi:10.1016/j.chroma.2019.01.022 · Cited by 167
Aydin, F., Yilmaz, E., & Soylak, M. (2017) · Microchemical Journal · doi:10.1016/j.microc.2017.02.014 · Cited by 165 · cited 1×
“The main combination chosen as an extraction solvent is ChCl-phenol at molar ratios of 1:3 and 1:4, applied to different samples for the determination of several analytes such as: cobalt Co (II) in a pharmaceutical supplement and tea samples by a microsample injection system, coupled with flame atomic absorption spect…”
MethodGreener Media in Chemical Synthesis and Processing
Avalos, M., Babiano, R., Cintas, P., Jiménez, J. L., & Palacios, J. C. (2006) · Angewandte Chemie International Edition · doi:10.1002/anie.200504285 · Cited by 158
Mirzajani, R., Kardani, F., & Ramezani, Z. (2020) · Food Chemistry · doi:10.1016/j.foodchem.2020.126179 · Cited by 153 · cited 1×
“The DES consisted of ChCl-Gly (2:1), which was then used for the preparation of the MOF-DES/MIPs SPME fibers [68].”
MethodDeep eutectic solvent-based dispersive liquid-liquid microextraction
Farajzadeh, M. A., Afshar Mogaddam, M. R., & Aghanassab, M. (2016) · Analytical Methods · doi:10.1039/c5ay03189c · Cited by 141
Benedé, J. L., Chisvert, A., Giokas, D. L., & Salvador, A. (2014) · Journal of Chromatography A · doi:10.1016/j.chroma.2014.08.024 · Cited by 133 · cited 1×
“To extract the analytes from the sample, the same methodology with SBSE was carried out [70].”
MethodWang, R., Li, W., & Chen, Z. (2018) · Analytica Chimica Acta · doi:10.1016/j.aca.2018.02.024 · Cited by 132
Li, K., Jin, Y., Jung, D., Park, K., Kim, H., & Lee, J. (2020) · Journal of Chromatography A · doi:10.1016/j.chroma.2019.460730 · Cited by 131
Zounr, R. A., Tuzen, M., Deligonul, N., & Khuhawar, M. Y. (2018) · Food Chemistry · doi:10.1016/j.foodchem.2018.01.167 · Cited by 127 · cited 5×
“Abbreviations AA-DLLME: Air Assisted Dispersive Liquid Liquid Microextraction AA-LLME: Air Assisted Liquid Liquid Microextraction CA: Chlorogenic Acid ChCl: Choline Chloride Cit-Suc: Citric acid-sucrose DecA: Decanoic Acid DES: Deep Eutectic Solvent DI-SPME: Direct Immersion Solid Phase Microextraction DI-SDME: Direct…”
MethodInfluentialYousefi, S. M., Shemirani, F., & Ghorbanian, S. A. (2017) · Talanta · doi:10.1016/j.talanta.2017.03.020 · Cited by 125 · cited 1×
“27 ng/L, and the enhancement factors were between 270–340, which are better than other techniques cited in the study [58].”
MethodGe, D., Zhang, Y., Dai, Y., & Yang, S. (2018) · Journal of Separation Science · doi:10.1002/jssc.201701282 · Cited by 121
Wang, H., Hu, L., Liu, X., Yin, S., Lu, R., Zhang, S., Zhou, W., & Gao, H. (2017) · Journal of Chromatography A · doi:10.1016/j.chroma.2017.07.073 · Cited by 118
Khataei, M. M., Yamini, Y., Nazaripour, A., & Karimi, M. (2018) · Talanta · doi:10.1016/j.talanta.2017.09.068 · Cited by 113 · cited 1×
“5%, which indicates the applicability of the method to biological samples that require complicated sample preparation [88].”
BackgroundYao, X.-H., Zhang, D., Duan, M.-H., Cui, Q., Xu, W., Luo, M., Li, C., Zu, Y., & Fu, Y. (2015) · Separation and Purification Technology · doi:10.1016/j.seppur.2015.03.037 · Cited by 112
Zarei, A. R., Nedaei, M., & Ghorbanian, S. A. (2018) · Journal of Chromatography A · doi:10.1016/j.chroma.2018.04.023 · Cited by 111 · cited 1×
“The proposed technique was coupled with HPLC-UV and the limit of detection was comparable with other existing methods, with the main advantage being the use of a low amount of an environmentally friendly extraction solvent [98].”
MethodAltunay, N., Elik, A., & Gürkan, R. (2019) · Microchemical Journal · doi:10.1016/j.microc.2019.03.003 · Cited by 111
Wang, M., Wang, J., Zhang, Y., Xia, Q., Bi, W., Yang, X., & Chen, D. D. Y. (2016) · Journal of Chromatography A · doi:10.1016/j.chroma.2016.03.061 · Cited by 108
Shishov, A., Terno, P., Moskvin, L., & Bulatov, A. (2020) · Talanta · doi:10.1016/j.talanta.2019.120209 · Cited by 107
Tang, B., Bi, W., Zhang, H., & Row, K. H. (2014) · Chromatographia · doi:10.1007/s10337-013-2607-3 · Cited by 105 · cited 1×
“The volume of extraction solvent was very small (2 μL), however the LODs were sufficiently good and the applicability to volatile compounds was proven [95].”
BackgroundSafavi, A., Ahmadi, R., & Ramezani, A. M. (2018) · Microchemical Journal · doi:10.1016/j.microc.2018.07.036 · Cited by 101
Li, T., Song, Y., Li, J., Zhang, M., Shi, Y., & Fan, J. (2020) · Food Chemistry · doi:10.1016/j.foodchem.2019.125752 · Cited by 96
Kanberoglu, G. S., Yilmaz, E., & Soylak, M. (2019) · Journal of Molecular Liquids · doi:10.1016/j.molliq.2019.01.130 · Cited by 91
Chen, J., Wang, Y., Wei, X., Xu, P., Xu, W., Ni, R., & Meng, J. (2018) · Talanta · doi:10.1016/j.talanta.2018.06.016 · Cited by 91
Ji, Y., Meng, Z., Zhao, J., Zhao, H., & Zhao, L. (2020) · Journal of Chromatography A · doi:10.1016/j.chroma.2019.460520 · Cited by 89
A New Proton Conductive Liquid with No Ions: Pseudo‐Protic Ionic Liquids
Doi, H., Song, X., Minofar, B., et al. (2013) · Chemistry - A European Journal · doi:10.1002/chem.201302228 · Cited by 88 · cited 1×
“There is also an intensive study explaining the effect of hydrogen bonding proton transfer mechanism on the physical and chemical properties [36].”
BackgroundLi, L., Liu, Y., Wang, Z., Yang, L., & Liu, H. (2021) · Journal of Separation Science · doi:10.1002/jssc.202000523 · Cited by 88
Recent Advances in Applications of Ionic Liquids in Miniaturized Microextraction Techniques
Kissoudi, M., & Samanidou, V. (2018) · Molecules · doi:10.3390/molecules23061437 · Cited by 86 · cited 1×
“These showed a stronger ecofriendly profile, with easier and cheaper production, while having similar properties [18].”
BackgroundSelf-citationNemati, M., Farajzadeh, M. A., Mohebbi, A., Khodadadeian, F., & Afshar Mogaddam, M. R. (2020) · Journal of Separation Science · doi:10.1002/jssc.201901000 · Cited by 85 · cited 1×
“Lastly, their mean relative recoveries were 92–95%, 94%, 93–95%, 92–98%, and 94–99% for each compound, respectively [72].”
BackgroundChen, J., Liu, M., Wang, Q., Du, H., & Zhang, L. (2016) · Molecules · doi:10.3390/molecules21101383 · Cited by 85 · cited 1×
“Various interactions (such as anion exchange, weak non-covalent interactions, π-π and/or hydrogen bonding) take place, amongst an HBD and an HBA in various combinations and molar ratios that contribute to some of the physicochemical properties discussed below [35].”
BackgroundAbolghasemi, M. M., Piryaei, M., & Imani, R. M. (2020) · Microchemical Journal · doi:10.1016/j.microc.2020.105041 · Cited by 84 · cited 1×
“0 μg/L) and more extensive linear ranges were obtained and compared to methods that utilized more sensitive detection systems like MS [99].”
MethodYousefi, S. M., Shemirani, F., & Ghorbanian, S. A. (2018) · Journal of Separation Science · doi:10.1002/jssc.201700807 · Cited by 79
Recent advances and applications of graphene-based extraction materials in food safety
Hou, X., Tang, S., & Wang, J. (2019) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2019.07.014 · Cited by 77 · cited 15×
“Other approaches to this technique are thin-film SPME (TF-SPME), in-tube SPME, hollow fiber SPME (HF-SPME), and in-needle SPME [43].”
MethodInfluentialTriaux, Z., Petitjean, H., Marchioni, E., Boltoeva, M., & Marcic, C. (2020) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-019-02317-9 · Cited by 77 · cited 1×
“Therefore, DES-HS-SDME is a simple, cheap, green, and efficient technique for the extraction of terpenes [96].”
MethodClark, J. H. (2009) · Nature Chemistry · doi:10.1038/nchem.146 · Cited by 75
Ma, W., & Row, K. H. (2021) · Microchemical Journal · doi:10.1016/j.microc.2020.105642 · Cited by 75
Lamei, N., Ezoddin, M., Ardestani, M. S., & Abdi, K. (2017) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-017-0547-8 · Cited by 73
Jouyban, A., Farajzadeh, M. A., Nemati, M., Alizadeh Nabil, A. A., & Afshar Mogaddam, M. R. (2020) · Microchemical Journal · doi:10.1016/j.microc.2020.104631 · Cited by 73
Thongsaw, A., Udnan, Y., Ross, G. M., & Chaiyasith, W. C. (2019) · Talanta · doi:10.1016/j.talanta.2019.01.018 · Cited by 73 · cited 5×
“Abbreviations AA-DLLME: Air Assisted Dispersive Liquid Liquid Microextraction AA-LLME: Air Assisted Liquid Liquid Microextraction CA: Chlorogenic Acid ChCl: Choline Chloride Cit-Suc: Citric acid-sucrose DecA: Decanoic Acid DES: Deep Eutectic Solvent DI-SPME: Direct Immersion Solid Phase Microextraction DI-SDME: Direct…”
MethodInfluentialZhang, K., Li, S., Liu, C., Wang, Q., Wang, Y., & Fan, J. (2019) · Journal of Separation Science · doi:10.1002/jssc.201800921 · Cited by 69
Ahmadi, R., Kazemi, G., Ramezani, A. M., & Safavi, A. (2019) · Microchemical Journal · doi:10.1016/j.microc.2018.11.005 · Cited by 68
Yuvali, D., Seyhaneyildizi, M., Soylak, M., Narin, İ., & Yilmaz, E. (2021) · Spectrochimica Acta Part A: Molecular and Biomolecular Spectroscopy · doi:10.1016/j.saa.2020.118842 · Cited by 67
Khezeli, T., & Daneshfar, A. (2015) · RSC Advances · doi:10.1039/c5ra08058d · Cited by 66 · cited 1×
“DSPE is based on the dispersion of a solid sorbent in liquid samples for the extraction, isolation, and cleaning of various target compounds from complex matrices [46].”
BackgroundMajidi, S. M., & Hadjmohammadi, M. R. (2019) · Journal of Separation Science · doi:10.1002/jssc.201900234 · Cited by 65
ALOthman, Z. A., Habila, M. A., Yilmaz, E., Alabdullkarem, E. A., & Soylak, M. (2020) · Measurement · doi:10.1016/j.measurement.2019.107394 · Cited by 65
Liu, L., Tang, W., Tang, B., Han, D., Row, K. H., & Zhu, T. (2017) · Journal of Separation Science · doi:10.1002/jssc.201601436 · Cited by 64
The use of magnetic nanoparticles in sample preparation devices and tools
Keçili, R., Büyüktiryaki, S., Dolak, İ., & Hussain, C. M. (2020) · Handbook of Nanomaterials in Analytical Chemistry · doi:10.1016/b978-0-12-816699-4.00005-0 · Cited by 64
Li, X., & Row, K. H. (2017) · Journal of Chromatography B · doi:10.1016/j.jchromb.2017.10.012 · Cited by 63
Doğan, B., Elik, A., & Altunay, N. (2020) · Microchemical Journal · doi:10.1016/j.microc.2020.104645 · Cited by 62
El-Deen, A. K., & Shimizu, K. (2020) · Journal of Chromatography A · doi:10.1016/j.chroma.2020.461498 · Cited by 62
Li, G., Wang, X., & Row, K. H. (2017) · Molecules · doi:10.3390/molecules22071061 · Cited by 61 · cited 1×
“The optimal DES for this study was ChCl-Urea (1:2) [51].”
MethodSantana-Mayor, Á., Socas-Rodríguez, B., Rodríguez-Ramos, R., & Rodríguez-Delgado, M. Á. (2020) · Food Chemistry · doi:10.1016/j.foodchem.2019.125798 · Cited by 60
Li, T., Song, Y., Xu, J., & Fan, J. (2019) · Talanta · doi:10.1016/j.talanta.2018.11.085 · Cited by 59
Majidi, S. M., & Hadjmohammadi, M. R. (2020) · Journal of Chromatography A · doi:10.1016/j.chroma.2020.461030 · Cited by 59
Zarei, A. R., Nedaei, M., & Ghorbanian, S. A. (2017) · Journal of Separation Science · doi:10.1002/jssc.201700915 · Cited by 56 · cited 1×
“It is also mentioned that the developed method is both user and environmentally friendly, according to the principles of the green analytical chemistry [71].”
MethodFu, N., Lv, R., Guo, Z., Guo, Y., You, X., Tang, B., Han, D., Yan, H., & Row, K. H. (2017) · Journal of Chromatography A · doi:10.1016/j.chroma.2017.02.036 · Cited by 55 · cited 1×
“The recoveries of the four analytes were 100% on the first cycle of usage of the DES, and they maintained a percentage between 60–117% throughout the five cycles studied in this work [48].”
MethodMa, W., Dai, Y., & Row, K. H. (2018) · ELECTROPHORESIS · doi:10.1002/elps.201800034 · Cited by 55
Abdi, K., Ezoddin, M., & Pirooznia, N. (2020) · Microchemical Journal · doi:10.1016/j.microc.2020.104999 · Cited by 55
Li, G., Wang, W., Wang, Q., & Zhu, T. (2015) · Journal of Chromatographic Science · doi:10.1093/chromsci/bmv138 · Cited by 54
Li, X., Wang, M., Zhao, J., Guo, H., Gao, X., Xiong, Z., & Zhao, L. (2019) · Journal of Pharmaceutical and Biomedical Analysis · doi:10.1016/j.jpba.2019.01.018 · Cited by 52 · cited 4×
“Ge et al. synthesized hydrophobic DESs based on DL-menthol, which were used for the first time in a microextraction technique (AA-DLLME) to determine six benzophenone-type (BP-type) UV filters in water samples (swimming pool water, river water, and wastewater samples) with HPLC-DAD.”
MethodInfluentialAryafard, M., Abbasi, M., Řeha, D., Harifi‐Mood, A. R., & Minofar, B. (2019) · Journal of Molecular Liquids · doi:10.1016/j.molliq.2019.03.149 · Cited by 52 · cited 2×
“reactions through preferential solvation (PS) [38].”
BackgroundMoghadam, A. G., Rajabi, M., & Asghari, A. (2017) · Journal of Chromatography B · doi:10.1016/j.jchromb.2017.09.042 · Cited by 51
Rajabi, M., Ghassab, N., Hemmati, M., & Asghari, A. (2019) · Journal of Chromatography B · doi:10.1016/j.jchromb.2018.11.008 · Cited by 49 · cited 1×
“8 ng mL−1, because of the method’s ability to clean-up and preconcentrate the target analytes [89].”
MethodWang, X., Li, G., & Row, K. H. (2017) · Bulletin of the Korean Chemical Society · doi:10.1002/bkcs.11074 · Cited by 47 · cited 1×
“The DESs used in this work were ChCl with FA, acetic acid, propionic acid, urea, Gly, ethylene glycol, and 1,4-butanodiol at the molar ratios of 1:2 [50].”
MethodKanberoglu, G. S., Yilmaz, E., & Soylak, M. (2019) · Microchemical Journal · doi:10.1016/j.microc.2018.11.053 · Cited by 47 · cited 4×
“Although the method is based on a simple detection instrument (UV-VIS), LODs were low, in the range of 0.5–2 µg/L.”
MethodInfluentialMehravar, A., Feizbakhsh, A., Sarafi, A. H. M., Konoz, E., & Faraji, H. (2020) · Journal of Chromatography A · doi:10.1016/j.chroma.2020.461618 · Cited by 46
Recent trends in microextraction techniques used in determination of arsenic species
Werner, J., Grześkowiak, T., Zgoła‐Grześkowiak, A., & Stanisz, E. (2018) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2018.05.006 · Cited by 46
Torbati, M., Farajzadeh, M. A., Afshar Mogaddam, M. R., & Torbati, M. (2019) · Microchemical Journal · doi:10.1016/j.microc.2019.04.044 · Cited by 44
Zarei, A. R., Nedaei, M., & Ghorbanian, S. A. (2017) · Journal of Molecular Liquids · doi:10.1016/j.molliq.2017.09.039 · Cited by 42 · cited 1×
“8 ng/L, respectively, and the relative recovery rates were 90–105%, 90–110%, 95–110%, 90–110%, and 95–107%, respectively, for each compound in the different water samples [60].”
BackgroundLi, G., & Row, K. H. (2018) · Journal of Separation Science · doi:10.1002/jssc.201800222 · Cited by 42
Pipette-tip SPE based on Graphene/ZnCr LDH for Pb(II) analysis in hair samples followed by GFAAS
Mirzaee, M. T., Seidi, S., & Alizadeh, R. (2020) · Analytical Biochemistry · doi:10.1016/j.ab.2020.113949 · Cited by 40
Xue, J., Wang, R., Chen, X., Hu, S., & Bai, X. (2019) · Journal of Separation Science · doi:10.1002/jssc.201900184 · Cited by 38 · cited 1×
“8 ng/mL, while the higher extraction efficiency and absence of salt were considered as advantages in comparison with 2p-HF-LPME [90].”
ResultWerner, J. (2020) · Journal of Separation Science · doi:10.1002/jssc.201901184 · Cited by 38
Sereshti, H., Jamshidi, F., Nouri, N., & Nodeh, H. R. (2020) · Journal of the Science of Food and Agriculture · doi:10.1002/jsfa.10279 · Cited by 38 · cited 1×
“Typically, ambient temperature molten salts have been formed by mixing quaternary ammonium salts, a hydrogen bond acceptor (HBA) with metal salts [32,33].”
BackgroundAlavi, L., Seidi, S., Jabbari, A., & Baheri, T. (2017) · New Journal of Chemistry · doi:10.1039/c7nj00922d · Cited by 37
Design of Sustainable Chemical Products — The Example of Ionic Liquids
Ranke, J., Stolte, S., Stoermann, R., et al. (2007) · ChemInform · doi:10.1002/chin.200736255 · Cited by 36
Al-Khshemawee, H., Du, X., Agarwal, M., Yang, J. O., & Ren, Y. L. (2018) · Molecules · doi:10.3390/molecules23112951 · Cited by 36 · cited 1×
“When the equilibrium between the fiber and the analytes is completed, the SPME fiber is inserted into a GC for thermal desorption or into a desorption solvent to a LC [65].”
MethodAnthemidis, A. N., & Mitani, C. (2013) · Current Analytical Chemistry · doi:10.2174/1573411011309020011 · Cited by 31 · cited 1×
“In addition to the tendency of reducing the use of solvents and the produced waste, in recent years, there have been new applications for specific techniques that include green solvents, such as ionic liquids and deep eutectic solvents, in order to substitute toxic organic reagents and minimize the cost [75,76].”
BackgroundZhang, S.-M., Zhang, X.-X., Chen, X., Hu, S., & Bai, X.-H. (2020) · Microchemical Journal · doi:10.1016/j.microc.2020.104696 · Cited by 30
Ma, W., & Row, K. H. (2020) · Molecules · doi:10.3390/molecules25020280 · Cited by 30 · cited 1×
“Both intra-day and inter-day yielded recoveries of the five analytes between 80–98% [55].”
BackgroundAryafard, M., Karimi, A., Harifi-Mood, A. R., & Minofar, B. (2020) · Journal of Chemical & Engineering Data · doi:10.1021/acs.jced.0c00381 · Cited by 29 · cited 1×
“Other properties taken into account before selecting the optimal DES are biodegradability, toxicity, and thermal stability [37].”
BackgroundRecent advances in solid-phase extraction techniques with nanomaterials
Wen, Y. (2019) · Elsevier eBooks · doi:10.1016/b978-0-12-816699-4.00004-9 · Cited by 28 · cited 1×
“[1,2] Furthermore, it eliminates typical problems like possible interferences and low sensitivity.”
BackgroundModern solutions in magnetic analytical extractions of metals: A review
Kabeer, M., Hakami, Y. A. A., Asif, M., Alrefaei, T., & Sajid, M. (2020) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2020.115987 · Cited by 27
The Role of Sample Preparation
Moldoveanu, S. C., & David, V. (2014) · Elsevier eBooks · doi:10.1016/b978-0-444-54319-6.00002-5 · Cited by 25
Li, G., & Rwo, K. H. (2019) · Polymers · doi:10.3390/polym11091434 · Cited by 24 · cited 1×
“36 times higher than that of NICS (non-imprinted chitosan) without DES [63].”
BackgroundSun, L., Deng, Q., & Zhu, T. (2019) · Journal of Separation Science · doi:10.1002/jssc.201900317 · Cited by 23
Low Toxic Ionic Liquids, Liquid Catanionics, and Ionic Liquid Microemulsions
Kunz, W., Maurer, E., Klein, R., Touraud, D., Rengstl, D., Harrar, A., Dengler, S., & Zech, O. (2011) · Journal of Dispersion Science and Technology · doi:10.1080/01932691.2011.616109 · Cited by 21
Recent advances in application of liquid-based micro-extraction: A review
He, Y. (2014) · Chemical Papers · doi:10.2478/s11696-014-0562-6 · Cited by 18 · cited 13×
“Other approaches to this technique are thin-film SPME (TF-SPME), in-tube SPME, hollow fiber SPME (HF-SPME), and in-needle SPME [43].”
BackgroundInfluentialMoldoveanu, S. C., & David, V. (2002) · Journal of chromatography library · doi:10.1016/s0301-4770(02)80002-1 · Cited by 17
Liao, Q. G., Da Wen, Z., Lin Guang, L., & Ci Dan, Z. X. (2020) · SEPARATION SCIENCE PLUS · doi:10.1002/sscp.201900064 · Cited by 14
4 Liquid-phase Microextraction Techniques
Fernández, E., & Vidal, L. (2014) · doi:10.2478/9783110410181.4 · Cited by 10
Cited by
Deep Eutectic Solvents (DESs) and Their Application in Biosensor Development
Svigelj, R., Dossi, N., Grazioli, C., & Toniolo, R. (2021) · Sensors · doi:10.3390/s21134263 · Cited by 137
“To date, DESs have found many applications in analytical chemistry, such as in the extraction of analytes from complex liquid and solid matrices [15], as modification media for nanomaterials [16,17], for elution in dispersive solid-phase extractions, and as a mobilephase modifier in chromatography [18,19].”
Applications of (natural) deep eutectic solvents in liquid phase microextraction: A review
Mansour, F. R., Bedair, A., Hamed, M., Magdy, G., Ali, I., & Locatelli, M. (2024) · Microchemical Journal · doi:10.1016/j.microc.2024.110178 · Cited by 112
Menthol-Based (Deep) Eutectic Solvents: A Review on Properties and Application in Extraction
Cherniakova, M., Varchenko, V., & Belikov, K. (2024) · The Chemical Record · doi:10.1002/tcr.202300267 · Cited by 83
Yıldırım, S., Cocovi-Solberg, D. J., Uslu, B., Solich, P., & Horstkotte, B. (2022) · Talanta · doi:10.1016/j.talanta.2022.123476 · Cited by 81
Design Strategy and Application of Deep Eutectic Solvents for Green Synthesis of Nanomaterials
Nam, N. N., Do, H. D. K., Trinh, K. T. L., & Lee, N. Y. (2023) · Nanomaterials · doi:10.3390/nano13071164 · Cited by 85
Metadata
- Authors
- Plastiras, O.-E., Andreasidou, E., & Samanidou, V.
- Affiliations
- Aristotle University of Thessaloniki (GR)
- Corresponding author
- Samanidou, Victoria
- Venue
- Molecules
- Publisher
- MDPI AG
- Published
- 2020-12-19
- Volume
- 25
- Issue
- 24
- Pages
- 6026
- ISSN
- 1420-3049 (ISSN-L)
- PMC
- PMC7767243
- OpenAlex
- W3113460930
- Semantic Scholar
- ffc083919e5191c751adc7ff22189b2b9a954f78
- Cited by
- 84
- References
- 136
- Citations by year
- 2026: 14 · 2025: 8 · 2024: 12 · 2023: 22 · 2022: 14 · 2021: 14
- FWCI
- 1.66
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Licence
- Locations
- Molecules (publishedVersion, cc-by)
- PubMed Central (publishedVersion, cc-by)
- PubMed (publishedVersion)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
- Topics
- Physical Sciences › Chemistry › Analytical Chemistry › Analytical chemistry methods development
- Physical Sciences › Chemistry › Physical and Theoretical Chemistry › Ionic liquids properties and applications
- Physical Sciences › Chemistry › Electrochemistry › Electrochemical Analysis and Applications
- Keywords
- deep eutectic solvents, microextraction, green analytical chemistry, solvent replacement, extraction properties, analytical parameters
- MeSH terms
- Humans, Solvents, Green Chemistry Technology, Liquid Phase Microextraction
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
The claim verdicts this report counts are experimental: their accuracy is not yet measured.
A language model drew the claims from the paper on 2026-09-29, under version 3 of the claim definition (model deepseek-v4.1-flash, prompt extract-v3).
A second model labelled each claim on 2026-09-29 (model jev-1.13-20260917, definition revision gold-guideline-v0.2).
Cited sources are checked with a language model’s help (gpt-6-sol).
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.
