The DOI matches its Crossref record; 182 of the 182 references it cites were found in a registry or an index.
Recent Advances in Enzymatic and Non-Enzymatic Electrochemical Glucose Sensing
Open accessAbstract
The detection of glucose is crucial in the management of diabetes and other medical conditions but also crucial in a wide range of industries such as food and beverages. The development of glucose sensors in the past century has allowed diabetic patients to effectively manage their disease and has saved lives. First-generation glucose sensors have considerable limitations in sensitivity and selectivity which has spurred the development of more advanced approaches for both the medical and industrial sectors. The wide range of application areas has resulted in a range of materials and fabrication techniques to produce novel glucose sensors that have higher sensitivity and selectivity, lower cost, and are simpler to use. A major focus has been on the development of enzymatic electrochemical sensors, typically using glucose oxidase. However, non-enzymatic approaches using direct electrochemistry of glucose on noble metals are now a viable approach in glucose biosensor design. This review discusses the mechanisms of electrochemical glucose sensing with a focus on the different generations of enzymatic-based sensors, their recent advances, and provides an overview of the next generation of non-enzymatic sensors. Advancements in manufacturing techniques and materials are key in propelling the field of glucose sensing, however, significant limitations remain which are highlighted in this review and requires addressing to obtain a more stable, sensitive, selective, cost efficient, and real-time glucose sensor.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
ELECTRODE SYSTEMS FOR CONTINUOUS MONITORING IN CARDIOVASCULAR SURGERY
Clark, L. C., & Lyons, C. (1962) · Annals of the New York Academy of Sciences · doi:10.1111/j.1749-6632.1962.tb13623.x · Cited by 3,945
Mechanisms of fatty acid-induced inhibition of glucose uptake.
Boden, G., Chen, X., Ruiz, J., White, J. V., & Rossetti, L. (1994) · Journal of Clinical Investigation · doi:10.1172/jci117252 · Cited by 3,705
Electrochemical Glucose Biosensors
Wang, J. (2008) · Chemical Reviews · doi:10.1021/cr068123a · Cited by 3,498
Electrochemical Glucose Sensors and Their Applications in Diabetes Management
Heller, A., & Feldman, B. (2008) · Chemical Reviews · doi:10.1021/cr068069y · Cited by 1,707
UPDIKE, S. J., & HICKS, G. P. (1967) · Nature · doi:10.1038/214986a0 · Cited by 1,336
Direct Electrochemistry of Glucose Oxidase and Biosensing for Glucose Based on Graphene
Shan, C., Yang, H., Song, J., Han, D., Ivaska, A., & Niu, L. (2009) · Analytical Chemistry · doi:10.1021/ac802193c · Cited by 1,315
Bankar, S. B., Bule, M. V., Singhal, R. S., & Ananthanarayan, L. (2009) · Biotechnology Advances · doi:10.1016/j.biotechadv.2009.04.003 · Cited by 1,253
Additive manufacturing of tissues and organs
Melchels, F. P. W., Domingos, M. A. N., Klein, T. J., Malda, J., Bartolo, P. J., & Hutmacher, D. W. (2012) · Progress in Polymer Science · doi:10.1016/j.progpolymsci.2011.11.007 · Cited by 1,213
Self-citationElectrochemical non-enzymatic glucose sensors
Park, S., Boo, H., & Chung, T. D. (2006) · Analytica Chimica Acta · doi:10.1016/j.aca.2005.05.080 · Cited by 1,159
Electrochemical Non-enzymatic Glucose Sensors: A Perspective and an Evaluation
Toghill, K. E., & Compton, R. G. (2010) · International Journal of Electrochemical Science · doi:10.1016/s1452-3981(23)15359-4 · Cited by 926
The oxidation of organic compounds at a nickel anode in alkaline solution
Fleischmann, M., Kořínek, K., & Pletcher, D. (1971) · Journal of Electroanalytical Chemistry · doi:10.1016/s0022-0728(71)80040-2 · Cited by 888
Electrochemical glucose sensors in diabetes management: an updated review (2010–2020)
Teymourian, H., Barfidokht, A., & Wang, J. (2020) · Chemical Society Reviews · doi:10.1039/d0cs00304b · Cited by 881
Applications of dip-pen nanolithography
Salaita, K., Wang, Y., & Mirkin, C. A. (2007) · Nature Nanotechnology · doi:10.1038/nnano.2007.39 · Cited by 845
Recent advances in electrochemical glucose biosensors: a review
Chen, C., Xie, Q., Yang, D., Xiao, H., Fu, Y., Tan, Y., & Yao, S. (2013) · RSC Advances · doi:10.1039/c2ra22351a · Cited by 807
Recent advances in electrochemical non-enzymatic glucose sensors – A review
Hwang, D.-W., Lee, S., Seo, M., & Chung, T. D. (2018) · Analytica Chimica Acta · doi:10.1016/j.aca.2018.05.051 · Cited by 788
Glucose Sensing for Diabetes Monitoring: Recent Developments
Bruen, D., Delaney, C., Florea, L., & Diamond, D. (2017) · Sensors · doi:10.3390/s17081866 · Cited by 777
A Comprehensive Review of Glucose Biosensors Based on Nanostructured Metal-Oxides
Rahman, M. M., Ahammad, A. J. S., Jin, J.-H., Ahn, S. J., & Lee, J.-J. (2010) · Sensors · doi:10.3390/s100504855 · Cited by 762
Glucose Biosensors: 40 Years of Advances and Challenges
Wang, J. (2001) · Electroanalysis · doi:10.1002/1521-4109(200108)13:12<983::aid-elan983>3.0.co;2-# · Cited by 752
Wongkaew, N., Simsek, M., Griesche, C., & Baeumner, A. J. (2019) · Chemical Reviews · doi:10.1021/acs.chemrev.8b00172 · Cited by 657
Electrical connection of enzyme redox centers to electrodes
Heller, A. (1992) · The Journal of Physical Chemistry · doi:10.1021/j100188a007 · Cited by 603
Molecularly Imprinted Polymers in Electrochemical and Optical Sensors
Ahmad, O. S., Bedwell, T. S., Esen, C., Garcia-Cruz, A., & Piletsky, S. A. (2019) · Trends in Biotechnology · doi:10.1016/j.tibtech.2018.08.009 · Cited by 602
Nonenzymatic Glucose Detection Using Mesoporous Platinum
Park, S., Chung, T. D., & Kim, H. C. (2003) · Analytical Chemistry · doi:10.1021/ac0263465 · Cited by 594
An enzyme electrode for the amperometric determination of glucose
Guilbault, G. G., & Lubrano, G. J. (1973) · Analytica Chimica Acta · doi:10.1016/s0003-2670(01)82476-4 · Cited by 571
Malitesta, C., Palmisano, F., Torsi, L., & Zambonin, P. G. (1990) · Analytical Chemistry · doi:10.1021/ac00223a016 · Cited by 570
A Critical Review of Glucose Biosensors Based on Carbon Nanomaterials: Carbon Nanotubes and Graphene
Zhu, Z., Garcia-Gancedo, L., Flewitt, A. J., Xie, H., Moussy, F., & Milne, W. I. (2012) · Sensors · doi:10.3390/s120505996 · Cited by 549
Functional Properties and Genomics of Glucose Transporters
Zhao, F.-Q., & Keating, A. (2007) · Current Genomics · doi:10.2174/138920207780368187 · Cited by 549
Screen-printed electrodes for biosensing: a review (2008–2013)
Taleat, Z., Khoshroo, A., & Mazloum-Ardakani, M. (2014) · Microchimica Acta · doi:10.1007/s00604-014-1181-1 · Cited by 542
Review of Glucose Oxidases and Glucose Dehydrogenases: A Bird's Eye View of Glucose Sensing Enzymes
Ferri, S., Kojima, K., & Sode, K. (2011) · Journal of Diabetes Science and Technology · doi:10.1177/193229681100500507 · Cited by 471
Skin-like biosensor system via electrochemical channels for noninvasive blood glucose monitoring
Chen, Y., Lu, S., Zhang, S., Li, Y., Qu, Z., Chen, Y., Lu, B., Wang, X., & Feng, X. (2017) · Science Advances · doi:10.1126/sciadv.1701629 · Cited by 467
Prussian Blue-Based First-Generation Biosensor. A Sensitive Amperometric Electrode for Glucose
Karyakin, A. A., Gitelmacher, O. V., & Karyakina, E. E. (1995) · Analytical Chemistry · doi:10.1021/ac00110a016 · Cited by 456
Kinetics and mechanism of glucose electrooxidation on different electrode-catalysts
Vassilyev, Y. B., Khazova, O. A., & Nikolaeva, N. N. (1985) · Journal of Electroanalytical Chemistry and Interfacial Electrochemistry · doi:10.1016/0022-0728(85)85084-1 · Cited by 422
Chemisorption on metal surfaces
Norsko, J. K. (1990) · Reports on Progress in Physics · doi:10.1088/0034-4885/53/10/001 · Cited by 399
Developments in 4D-printing: a review on current smart materials, technologies, and applications
Zhang, Z., Demir, K. G., & Gu, G. X. (2019) · International Journal of Smart and Nano Materials · doi:10.1080/19475411.2019.1591541 · Cited by 392
Li, C., Iqbal, M., Lin, J., Luo, X., Jiang, B., Malgras, V., Wu, K. C.-W., Kim, J., & Yamauchi, Y. (2018) · Accounts of Chemical Research · doi:10.1021/acs.accounts.8b00119 · Cited by 378
Duda, T., & Raghavan, L. V. (2016) · IFAC-PapersOnLine · doi:10.1016/j.ifacol.2016.11.111 · Cited by 374
Willner, I., Heleg-Shabtai, V., Blonder, R., Katz, E., Tao, G., Bückmann, A. F., & Heller, A. (1996) · Journal of the American Chemical Society · doi:10.1021/ja9608611 · Cited by 370
Inkjet printing biomaterials for tissue engineering: bioprinting
Saunders, R. E., & Derby, B. (2014) · International Materials Reviews · doi:10.1179/1743280414y.0000000040 · Cited by 365
Mouthguard biosensor with telemetry system for monitoring of saliva glucose: A novel cavitas sensor
Arakawa, T., Kuroki, Y., Nitta, H., Chouhan, P., Toma, K., Sawada, S.-I., Takeuchi, S., Sekita, T., Akiyoshi, K., Minakuchi, S., et al. (2016) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2015.12.014 · Cited by 356
Degani, Y., & Heller, A. (1989) · Journal of the American Chemical Society · doi:10.1021/ja00188a091 · Cited by 354
Electrochemical characterization of carbohydrate oxidation at copper electrodes
Marioli, J. M., & Kuwana, T. (1992) · Electrochimica Acta · doi:10.1016/0013-4686(92)85055-p · Cited by 351
Schuhmann, W., Ohara, T. J., Schmidt, H. L., & Heller, A. (1991) · Journal of the American Chemical Society · doi:10.1021/ja00004a048 · Cited by 348
Zhang, Y., Li, N., Xiang, Y., Wang, D., Zhang, P., Wang, Y., Lu, S., Xu, R., & Zhao, J. (2020) · Carbon · doi:10.1016/j.carbon.2019.10.006 · Cited by 345
Xiao, F., Zhao, F., Mei, D., Mo, Z., & Zeng, B. (2009) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2009.04.045 · Cited by 344
Sasso, S. V., Pierce, R. J., Walla, R., & Yacynych, A. M. (1990) · Analytical Chemistry · doi:10.1021/ac00210a004 · Cited by 343
Mechanism of glucose electrochemical oxidation on gold surface
Pasta, M., La Mantia, F., & Cui, Y. (2010) · Electrochimica Acta · doi:10.1016/j.electacta.2010.04.069 · Cited by 331
Cell-based biosensors: Recent trends, challenges and future perspectives
Gupta, N., Renugopalakrishnan, V., Liepmann, D., Paulmurugan, R., & Malhotra, B. D. (2019) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2019.111435 · Cited by 318
Tang, H., Yan, F., Lin, P., Xu, J., & Chan, H. L. W. (2011) · Advanced Functional Materials · doi:10.1002/adfm.201002117 · Cited by 310
Recent Development in Optical Fiber Biosensors
Bosch, M. E., Sánchez, A. J. R., Rojas, F. S., & Ojeda, C. B. (2007) · Sensors · doi:10.3390/s7060797 · Cited by 287
Omer, A. E., Shaker, G., Safavi-Naeini, S., Kokabi, H., Alquié, G., Deshours, F., & Shubair, R. M. (2020) · Scientific Reports · doi:10.1038/s41598-020-72114-3 · Cited by 283
Teymourian, H., Moonla, C., Tehrani, F., Vargas, E., Aghavali, R., Barfidokht, A., Tangkuaram, T., Mercier, P. P., Dassau, E., & Wang, J. (2020) · Analytical Chemistry · doi:10.1021/acs.analchem.9b05109 · Cited by 278
Ventura, E. E., Davis, J. N., & Goran, M. I. (2011) · Obesity · doi:10.1038/oby.2010.255 · Cited by 278
Niu, X., Li, X., Pan, J., He, Y., Qiu, F., & Yan, Y. (2016) · RSC Advances · doi:10.1039/c6ra12506a · Cited by 275
Holland, J. T., Lau, C., Brozik, S. M., Atanassov, P. B., & Banta, S. A. (2011) · Journal of the American Chemical Society · doi:10.1021/ja2071237 · Cited by 266
Gold nanowire array electrode for non-enzymatic voltammetric and amperometric glucose detection
Cherevko, S., & Chung, C.-H. (2009) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2009.07.023 · Cited by 251
Kinetics and mechanism of glucose electrooxidation on different electrode-catalysts
Vassilyev, Y. B., Khazova, O. A., & Nikolaeva, N. N. (1985) · Journal of Electroanalytical Chemistry and Interfacial Electrochemistry · doi:10.1016/0022-0728(85)85085-3 · Cited by 239
Can continuous glucose monitoring be used for the treatment of diabetes?
Reach, G., & Wilson, G. S. (1992) · Analytical Chemistry · doi:10.1021/ac00030a001 · Cited by 235
Facilitated Hexose Transporters: New Perspectives on Form and Function
Manolescu, A. R., Witkowska, K., Kinnaird, A., Cessford, T., & Cheeseman, C. (2007) · Physiology · doi:10.1152/physiol.00011.2007 · Cited by 235
An amperometric glucose biosensor prototype fabricated by thermal inkjet printing
Setti, L., Fraleoni-Morgera, A., Ballarin, B., Filippini, A., Frascaro, D., & Piana, C. (2005) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2004.09.022 · Cited by 231
Nickel oxide hollow microsphere for non-enzyme glucose detection
Ci, S., Huang, T., Wen, Z., Cui, S., Mao, S., Steeber, D. A., & Chen, J. (2014) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2013.11.006 · Cited by 224
Conducting polymer based electrochemical biosensors
Aydemir, N., Malmström, J., & Travas-Sejdic, J. (2016) · Physical Chemistry Chemical Physics · doi:10.1039/c5cp06830d · Cited by 224
Premonolayer oxidation and its role in electrocatalysis
Burke, L. D. (1994) · Electrochimica Acta · doi:10.1016/0013-4686(94)85173-5 · Cited by 223
Two-dimensional enzyme electrode sensor for glucose
Gough, D. A., Lucisano, J. Y., & Tse, P. H. S. (1985) · Analytical Chemistry · doi:10.1021/ac00289a042 · Cited by 223
Enzyme based amperometric biosensors
Bollella, P., & Gorton, L. (2018) · Current Opinion in Electrochemistry · doi:10.1016/j.coelec.2018.06.003 · Cited by 223
Aoun, S. B., Dursun, Z., Koga, T., Bang, G. S., Sotomura, T., & Taniguchi, I. (2004) · Journal of Electroanalytical Chemistry · doi:10.1016/j.jelechem.2003.12.022 · Cited by 211
Zayats, M., Katz, E., Baron, R., & Willner, I. (2005) · Journal of the American Chemical Society · doi:10.1021/ja052841h · Cited by 210
Baek, S. H., Roh, J., Park, C. Y., Kim, M. W., Shi, R., Kailasa, S. K., & Park, T. J. (2020) · Materials Science and Engineering: C · doi:10.1016/j.msec.2019.110273 · Cited by 207
Mohamed, M. G., Atayde, E. C., Matsagar, B. M., Na, J., Yamauchi, Y., Wu, K. C.-W., & Kuo, S.-W. (2020) · Journal of the Taiwan Institute of Chemical Engineers · doi:10.1016/j.jtice.2020.06.013 · Cited by 205
Use of polymer films in amperometric biosensors
Emr, S. A., & Yacynych, A. M. (1995) · Electroanalysis · doi:10.1002/elan.1140071002 · Cited by 202
Zhang, X., Xu, Y., & Ye, B. (2018) · Journal of Alloys and Compounds · doi:10.1016/j.jallcom.2018.07.175 · Cited by 202
Wearable-band type visible-near infrared optical biosensor for non-invasive blood glucose monitoring
Rachim, V. P., & Chung, W.-Y. (2019) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2019.01.121 · Cited by 200
Electrooxidation of alcohols and sugars catalysed on a nickel oxide modified glassy carbon electrode
Berchmans, S., Gomathi, H., & Rao, G. P. (1995) · Journal of Electroanalytical Chemistry · doi:10.1016/0022-0728(95)04099-a · Cited by 196
Electrochemical Biosensors for Medical and Food Applications
Ahmed, M. U., Hossain, M. M., & Tamiya, E. (2008) · Electroanalysis · doi:10.1002/elan.200704121 · Cited by 195
Elimination of the Acetaminophen Interference in an Implantable Glucose Sensor
Zhang, Y., Hu, Y., Wilson, G. S., Moatti-Sirat, D., Poitout, V., & Reach, G. (1994) · Analytical Chemistry · doi:10.1021/ac00079a038 · Cited by 184
Fu, S., Fan, G., Yang, L., & Li, F. (2015) · Electrochimica Acta · doi:10.1016/j.electacta.2014.11.115 · Cited by 181
Highly Selective Membrane-Free, Mediator-Free Glucose Biosensor
Wang, J., Liu, J., Chen, L., & Lu, F. (1994) · Analytical Chemistry · doi:10.1021/ac00093a011 · Cited by 174
Chi, Q., & Dong, S. (1995) · Analytica Chimica Acta · doi:10.1016/0003-2670(95)00152-p · Cited by 172
Metal nanostructures for non-enzymatic glucose sensing
Tee, S. Y., Teng, C. P., & Ye, E. (2017) · Materials Science and Engineering: C · doi:10.1016/j.msec.2016.04.009 · Cited by 172
Wang, F., Chen, X., Chen, L., Yang, J., & Wang, Q. (2018) · Materials Science and Engineering C · doi:10.1016/j.msec.2018.11.004 · Cited by 171
Choi, T., Kim, S. H., Lee, C. W., Kim, H., Choi, S.-K., Kim, S.-H., Kim, E., Park, J., & Kim, H. (2015) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2014.07.059 · Cited by 166
Xiao, F., Li, Y., Gao, H., Ge, S., & Duan, H. (2012) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2012.08.062 · Cited by 158
Electrocatalytic oxidation of glucose on Ni and NiCu alloy modified glassy carbon electrode
Jafarian, M., Forouzandeh, F., Danaee, I., Gobal, F., & Mahjani, M. G. (2009) · Journal of Solid State Electrochemistry · doi:10.1007/s10008-008-0632-1 · Cited by 158
Nantaphol, S., Watanabe, T., Nomura, N., Siangproh, W., Chailapakul, O., & Einaga, Y. (2017) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2017.06.034 · Cited by 158
Xu, M., Song, Y., Ye, Y.-H., Gong, C., Shen, Y., Wang, L., Wang, L., Wang, L., & Wang, L. (2017) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2017.07.147 · Cited by 155
Vafapour, Z. (2019) · IEEE Transactions on NanoBioscience · doi:10.1109/tnb.2019.2929802 · Cited by 150
Ju, J., Hsieh, C.-M., Tian, Y., Kang, J., Chia, R. N., Chang, H., Bai, Y., Xu, C., Wang, X., & Liu, Q. (2020) · ACS Sensors · doi:10.1021/acssensors.0c00444 · Cited by 150
4D Printing: Future Insight in Additive Manufacturing
Zafar, M. Q., & Zhao, H. (2019) · Metals and Materials International · doi:10.1007/s12540-019-00441-w · Cited by 146
Deshmukh, M. A., Kang, B.-C., & Ha, T. (2020) · Journal of Materials Chemistry C · doi:10.1039/c9tc06836h · Cited by 145
Zhang, H., Meng, Z., Wang, Q., & Zheng, J. (2011) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2011.04.057 · Cited by 137
A review of optical methods for continuous glucose monitoring
Jernelv, I. L., Mileńko, K., Fuglerud, S. S., Hjelme, D. R., Ellingsen, R., & Aksnes, A. (2018) · Applied Spectroscopy Reviews · doi:10.1080/05704928.2018.1486324 · Cited by 137
Zayats, M., Willner, B., & Willner, I. (2008) · Electroanalysis · doi:10.1002/elan.200704128 · Cited by 136
Chang, G., Shu, H., Huang, Q., Oyama, M., Ji, K., Liu, X., & He, Y. (2015) · Electrochimica Acta · doi:10.1016/j.electacta.2015.01.085 · Cited by 135
Mădăraş, M. B., & Buck, R. P. (1996) · Analytical Chemistry · doi:10.1021/ac960239r · Cited by 134
A microwave frequency sensor for non-invasive blood-glucose measurement
Jean, B. R., Green, E. C., & McClung, M. J. (2008) · IEEE Sensors Applications Symposium (SAS) · doi:10.1109/sas.2008.4472932 · Cited by 133
Liu, X., Yang, W., Chen, L., & Jia, J. (2017) · Electrochimica Acta · doi:10.1016/j.electacta.2017.03.150 · Cited by 130
Csöregi, E., Schmidtke, D. W., & Heller, A. (1995) · Analytical Chemistry · doi:10.1021/ac00103a015 · Cited by 129
Oxygen-Rich Oxidase Enzyme Electrodes for Operation in Oxygen-Free Solutions
Wang, J., & Lü, F. (1998) · Journal of the American Chemical Society · doi:10.1021/ja972759p · Cited by 127
Biosensors—Recent Advances and Future Challenges in Electrode Materials
Otero, F., & Magner, E. (2020) · Sensors · doi:10.3390/s20123561 · Cited by 121
Optical Biosensors for Therapeutic Drug Monitoring
Garzón, V., Pinacho, D. G., Bustos, R., Garzón, G., & Bustamante-Lopez, S. C. (2019) · Biosensors · doi:10.3390/bios9040132 · Cited by 119
Integrated medical feedback systems for drug delivery
Heller, A. (2005) · AIChE Journal · doi:10.1002/aic.10489 · Cited by 117
Niu, X., Li, Y., Tang, J., Hu, Y., Zhao, H., & Lan, M. (2013) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2013.07.032 · Cited by 116
Zhao, Y., Li, X., Schechter, J., & Yang, Y. A. (2016) · RSC Advances · doi:10.1039/c5ra24249e · Cited by 112
Diouf, A., Bouchikhi, B., & Bari, N. E. (2019) · Materials Science and Engineering C · doi:10.1016/j.msec.2019.01.001 · Cited by 112
Al-Sagur, H., Komathi, S., Khan, M. A., Gürek, A., & Hassan, A. M. (2016) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2016.10.038 · Cited by 111
Electrochemically roughened nanoporous platinum electrodes for non-enzymatic glucose sensors
Weremfo, A., Fong, S. T. C., Khan, A. L., Hibbert, D. B., & Zhao, C. (2017) · Electrochimica Acta · doi:10.1016/j.electacta.2017.02.018 · Cited by 111
Newman, J. D., White, S. F., Tothill, I. E., & Turner, A. P. F. (1995) · Analytical Chemistry · doi:10.1021/ac00120a027 · Cited by 109
Alkaline glucose oxidation on nanostructured gold electrodes
Pasta, M., Ruffο, R., Falletta, E., Mari, C. M., & Pina, C. D. (2010) · Gold bulletin · doi:10.1007/bf03214967 · Cited by 107
Cinti, S., Cusenza, R., Moscone, D., & Arduini, F. (2018) · Talanta · doi:10.1016/j.talanta.2018.05.015 · Cited by 105
Kano, K., Torimura, M., Esaka, Y., Goto, M., & Ueda, T. (1994) · Journal of Electroanalytical Chemistry · doi:10.1016/0022-0728(93)03252-k · Cited by 104
Yamauchi, Y., Suzuki, N., Radhakrishnan, L., & Wang, L. (2009) · The Chemical Record · doi:10.1002/tcr.200900022 · Cited by 104
Juska, V. B., & Pemble, M. E. (2018) · Electrochimica Acta · doi:10.1016/j.electacta.2018.12.068 · Cited by 101
Vukojević, V., Đurđić, S., Ognjanović, M. R., Fábian, M., Samphao, A., Kalcher, K., & Stanković, D. M. (2018) · Journal of Electroanalytical Chemistry · doi:10.1016/j.jelechem.2018.07.013 · Cited by 100
Orzari, L. O., de Freitas, R. C., Andreotti, I. A. D. A., Gatti, A., & Janegitz, B. C. (2019) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2019.05.015 · Cited by 99
Gao, X., Du, X., Liu, D., Gao, H., Wang, P., & Yang, J. (2020) · Scientific Reports · doi:10.1038/s41598-020-58403-x · Cited by 98
Nonenzymatic continuous glucose monitoring in human whole blood using electrified nanoporous Pt
Park, S., Park, S., Jeong, R.-A., Boo, H., Park, J., Kim, H. C., & Chung, T. D. (2011) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2011.10.033 · Cited by 97
Zhao, Y., Fan, L., Hong, B., Ren, J., Zhang, M., Que, Q., & Ji, J. (2016) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2016.03.115 · Cited by 90
The Global Burden of Diabetes: An Overview
Herman, W. H. (2016) · Springer eBooks · doi:10.1007/978-3-319-41559-8_1 · Cited by 90
Han, L., Zhang, S., Han, L., Yang, D., Hou, C., & Liu, A. (2014) · Electrochimica Acta · doi:10.1016/j.electacta.2014.06.095 · Cited by 87
Rafighi, P., Tavahodi, M., & Haghighi, B. (2016) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2016.03.147 · Cited by 87
Li, J., Liu, Y., Tang, X. X., Xu, L., Min, L., Xue, Y., Hu, X., & Yang, Z. (2020) · Microchimica Acta · doi:10.1007/s00604-019-4047-8 · Cited by 87
Zhang, C.-M., Zhang, R., Gao, X., Cheng, C., Hou, L., Li, X., & Chen, W. (2018) · ACS Omega · doi:10.1021/acsomega.7b01549 · Cited by 85
Sanzò, G., Taurino, I., Antiochia, R., Gorton, L. G. O., Favero, G., Mazzei, F., Micheli, G. D., & Carrara, S. (2016) · Bioelectrochemistry · doi:10.1016/j.bioelechem.2016.02.012 · Cited by 79
Long-term implantable glucose biosensors
Bobrowski, T., & Schuhmann, W. W. (2018) · Current Opinion in Electrochemistry · doi:10.1016/j.coelec.2018.05.004 · Cited by 78
The electrochemical oxidation of glucose on platinum—I. The oxidation in 1 M H2SO4
Skou, E. M. (1977) · Electrochimica Acta · doi:10.1016/0013-4686(77)85079-2 · Cited by 77
Tasca, F., Zafar, M. N., Harreither, W., Nöll, G., Ludwig, R., & Gorton, L. G. O. (2010) · The Analyst · doi:10.1039/c0an00311e · Cited by 74
Mehmeti, E., Stanković, D. M., Chaiyo, S., Zavašnik, J., Žagar, K., & Kalcher, K. (2017) · Microchimica Acta · doi:10.1007/s00604-017-2115-5 · Cited by 74
Boussema, F., Gross, A. J., Hmida, F., et al. (2018) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2018.02.060 · Cited by 73
Shrestha, B. K., Ahmad, R., Shrestha, S., Park, C. H., & Kim, C. S. (2017) · Scientific Reports · doi:10.1038/s41598-017-16541-9 · Cited by 68
Comparison of oxygen-rich and mediator-based glucose-oxidase carbon-paste electrodes
Wang, J., Mo, J.-W., Li, S., & Porter, J. (2001) · Analytica Chimica Acta · doi:10.1016/s0003-2670(01)01116-3 · Cited by 67
Suzuki, N., Lee, J., Loew, N., Inose-Takahashi, Y., Okuda‐Shimazaki, J., Kojima, K., Mori, K., Tsugawa, W., & Sode, K. (2020) · International Journal of Molecular Sciences · doi:10.3390/ijms21031137 · Cited by 67
Stolarczyk, K., Rogalski, J., & Bilewicz, R. (2020) · Bioelectrochemistry · doi:10.1016/j.bioelechem.2020.107574 · Cited by 67
Hossain, M. F., & Slaughter, G. E. (2020) · Journal of Electroanalytical Chemistry · doi:10.1016/j.jelechem.2020.113990 · Cited by 64
Gao, X., Feng, W., Zhu, Z., Wu, Z., Shi, L., Kan, S., Qiu, X., Guo, A., Chen, W., & Yin, K. (2021) · Advanced Materials Interfaces · doi:10.1002/admi.202002133 · Cited by 63
Synthesis of hollow Pt–Ni–graphene nanostructures for nonenzymatic glucose detection
Hu, Y., He, F., Ben, A., & Chen, C. (2014) · Journal of Electroanalytical Chemistry · doi:10.1016/j.jelechem.2014.05.012 · Cited by 61
Chen, X., Tian, X., Zhao, L., Huang, Z., & Oyama, M. (2013) · Microchimica Acta · doi:10.1007/s00604-013-1142-0 · Cited by 61
Ratiometric electrochemical glucose sensor based on electroactive Schiff base polymers
Wang, L., Xu, M., Xie, Y. B., Qian, C., Ma, W., Wang, L., & Song, Y. (2019) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2019.01.061 · Cited by 61
Wearable non-invasive monitors of diabetes and hypoxia through continuous analysis of sweat
Karpova, E. V., Karyakina, E. E., & Karyakin, A. A. (2020) · Talanta · doi:10.1016/j.talanta.2020.120922 · Cited by 61
Alhans, R., Singh, A., Singhal, C., Narang, J., Wadhwa, S., & Mathur, A. (2018) · Materials Science and Engineering C · doi:10.1016/j.msec.2018.04.072 · Cited by 59
Scandurra, A., Ruffino, F., Sanzaro, S., & Grimaldi, M. G. (2019) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2019.127113 · Cited by 57
Bornhoeft, L. R., Biswas, A., & McShane, M. J. (2017) · Biosensors · doi:10.3390/bios7010008 · Cited by 56
A highly permselective electrochemical glucose sensor using red blood cell membrane
Kim, I., Kwon, D., Lee, D., Lee, J. H., Lee, J. H., Lee, G., & Yoon, D. S. (2017) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2017.12.002 · Cited by 56
3D and 4D Printing in Biomedical Applications
(2018) · Wiley eBooks · doi:10.1002/9783527813704 · Cited by 54
Kim, S. H., Choi, J. B., Nguyen, Q. N., Lee, J. M., Park, S., Chung, T. D., & Byun, J. Y. (2012) · Physical Chemistry Chemical Physics · doi:10.1039/c2cp43097e · Cited by 53
Disposable non-enzymatic blood glucose sensing strip based on nanoporous platinum particles
Lee, S., Lee, J., Park, S., Boo, H., Kim, H. C., & Chung, T. D. (2017) · Applied Materials Today · doi:10.1016/j.apmt.2017.11.009 · Cited by 53
Ma, X., Tang, K., Yang, M., Shi, W., & Zhao, W. (2020) · Journal of Materials Science · doi:10.1007/s10853-020-05236-8 · Cited by 53
Burke, L. D., & Ryan, T. G. (1992) · Electrochimica Acta · doi:10.1016/0013-4686(92)87008-n · Cited by 52
Xu, Q. H., Yin, L., Hou, C., Liu, X., & Hu, X. (2012) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2012.07.071 · Cited by 50
Glucose sensor with improved haemocompatibilty
Yang, Y., Zhang, S. F., Kingston, M. A., Jones, G., Wright, G., & Spencer, S. A. (2000) · Biosensors and Bioelectronics · doi:10.1016/s0956-5663(00)00082-8 · Cited by 49
Non-enzymatic glucose sensing based on hierarchical platinum micro-/nanostructures
Unmüssig, T., Weltin, A., Urban, S., Daubinger, P., Urban, G. A., & Kieninger, J. (2018) · Journal of Electroanalytical Chemistry · doi:10.1016/j.jelechem.2018.03.061 · Cited by 49
Mei, Q., Fu, R., Ding, Y., Li, L., Wang, A., Duan, D., & Ye, D. (2019) · Journal of Electroanalytical Chemistry · doi:10.1016/j.jelechem.2019.04.035 · Cited by 49
Nguyen, T. N. H., Jin, X., Nolan, J. K., Xu, J., Le, K. V. H., Lam, S., Wang, Y., Alam, M. A., & Lee, H. (2020) · ACS Biomaterials Science & Engineering · doi:10.1021/acsbiomaterials.0c00647 · Cited by 48
Li, J., Koinkar, P., Fuchiwaki, Y., & Yasuzawa, M. (2016) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2016.06.037 · Cited by 47
Mao, Q., Jing, W., Zhou, F., Liu, S., Gao, W., Wei, Z., & Jiang, Z. (2020) · Materials Science in Semiconductor Processing · doi:10.1016/j.mssp.2020.105391 · Cited by 47
PQQ-GDH – Structure, function and application in bioelectrochemistry
Lisdat, F. (2020) · Bioelectrochemistry · doi:10.1016/j.bioelechem.2020.107496 · Cited by 45
Enzyme-Free Amperometric Detection of Glucose on Platinum-Replaced Porous Copper Frameworks
Hu, Y., Niu, X., Zhao, H., Tang, J., & Lan, M. (2015) · Electrochimica Acta · doi:10.1016/j.electacta.2015.03.036 · Cited by 44
Guascito, M. R., Chirizzi, D., Malitesta, C., Siciliano, M., Siciliano, T., & Tepore, A. (2012) · Electrochemistry Communications · doi:10.1016/j.elecom.2012.05.024 · Cited by 42
Dervisevic, M., Çevik, E., & Şenel, M. (2014) · Enzyme and Microbial Technology · doi:10.1016/j.enzmictec.2014.09.007 · Cited by 42
Krishnan, S. K., García, M., Prokhorov, E., Estévez, M., Pérez, R., Esparza, R., & Meyyappan, M. (2017) · Journal of Materials Chemistry B · doi:10.1039/c7tb01346a · Cited by 41
Casella, I. G., Stradis, A. D., & Desimoni, E. (1996) · The Analyst · doi:10.1039/an9962100249 · Cited by 40
Eryiğit, M., Çepni, E., Urhan, B. K., Doğan, H. Ö., & Özer, T. Ö. (2020) · Synthetic Metals · doi:10.1016/j.synthmet.2020.116488 · Cited by 40
A portable micro glucose sensor based on copper-based nanocomposite structure
Huang, C., Fan, G., Zhao, J., Qiu, M., Sun, P., Fu, Y., Han, D., & Cui, G. (2019) · New Journal of Chemistry · doi:10.1039/c9nj00888h · Cited by 38
Verma, N. (2018) · Applied Surface Science · doi:10.1016/j.apsusc.2018.08.175 · Cited by 37
Kausar, A., Reza, A. W., Latef, T. B. A., Ullah, M., & Karim, M. E. (2015) · Sensors · doi:10.3390/s150408787 · Cited by 36
Jeerapan, I., Sempionatto, J. R., You, J., & Wang, J. (2018) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2018.09.063 · Cited by 36
Wa, Q., Xiong, W., Zhao, R., He, Z., Chen, Y., & Wang, X. (2019) · ACS Applied Nano Materials · doi:10.1021/acsanm.9b00824 · Cited by 36
Functional Layer-By-Layer Design of Xerogel-Based First-Generation Amperometric Glucose Biosensors
Poulos, N. G., Hall, J. R., & Leopold, M. C. (2015) · Langmuir · doi:10.1021/la504358t · Cited by 34
Şenel, M., Nergiz, C., Dervisevic, M., & Çevik, E. (2013) · Electroanalysis · doi:10.1002/elan.201200535 · Cited by 33
Hao, L., Li, S., Wang, J., Tan, Y., Bai, L., & Liu, A. (2020) · Journal of Electroanalytical Chemistry · doi:10.1016/j.jelechem.2020.114602 · Cited by 32
Chen, A., Wang, J., Wang, Y., Jia, Y., Gu, J. F., Xie, X., & Pan, D. (2014) · Electrochimica Acta · doi:10.1016/j.electacta.2014.10.081 · Cited by 30
Marquitan, M., Bobrowski, T., Ernst, A., Wilde, P., Clausmeyer, J., Ruff, A., & Schuhmann, W. W. (2018) · Journal of The Electrochemical Society · doi:10.1149/2.0021812jes · Cited by 29
Rational design of CoNi alloy and atomic Co/Ni composite as an efficient electrocatalyst
Huo, J., Li, L., Shen, Z., Gao, H. J., & Liu, H. (2020) · Surface Innovations · doi:10.1680/jsuin.20.00028 · Cited by 29
Kafi, A. K. M., Alim, S., Jose, R., & Yusoff, M. M. (2019) · Journal of Electroanalytical Chemistry · doi:10.1016/j.jelechem.2019.113550 · Cited by 27
Kitikul, J., Satienperakul, S., Preechaworapun, A., Pookmanee, P., & Tangkuaram, T. (2016) · Electroanalysis · doi:10.1002/elan.201600263 · Cited by 25
Wang, J., & Wu, H. (1995) · Journal of Electroanalytical Chemistry · doi:10.1016/0022-0728(95)04128-b · Cited by 24
A bio-inspired highly selective enzymatic glucose sensor using a red blood cell membrane
Kim, I., Kim, C., Lee, D., Lee, S. W., Lee, G., & Yoon, D. S. (2020) · The Analyst · doi:10.1039/c9an02421b · Cited by 24
Pandey, P. C., Panday, D., & Pandey, G. (2014) · RSC Advances · doi:10.1039/c4ra07624a · Cited by 23
Cohen, R., Cohen, Y., Mukha, D., & Yehezkeli, O. (2020) · Electrochimica Acta · doi:10.1016/j.electacta.2020.137477 · Cited by 23
Electron transfer from FAD-dependent glucose dehydrogenase to single-sheet graphene electrodes
Filipiak, M. S., Vetter, D., Thodkar, K., Gutiérrez‐Sanz, Ó., Jönsson‐Niedziółka, M., & Tarasov, A. (2019) · Electrochimica Acta · doi:10.1016/j.electacta.2019.134998 · Cited by 22
Lee, J., Hyun, K., & Kwon, Y. (2020) · Journal of Industrial and Engineering Chemistry · doi:10.1016/j.jiec.2020.10.015 · Cited by 22
Nonenzymatic Electrochemical Sensor for Glucose Based on Nanoporous Platinum-Gold Alloy
Wang, J., Zhao, D., & Xu, C. (2016) · Journal of Nanoscience and Nanotechnology · doi:10.1166/jnn.2016.11377 · Cited by 16
Yang, Z., Miao, Y., Xu, L., Song, G., & Zhou, S. (2015) · Colloid Journal · doi:10.1134/s1061933x15030217 · Cited by 12
Iwasa, H., Hiratsuka, A., Tanaka, T., Tsuji, K., Kishimoto, T., Watanabe, Y., Hoshino, Y., & Muguruma, H. (2020) · IEEE Sensors Journal · doi:10.1109/jsen.2020.3001606 · Cited by 8
Guo, T., Zhang, Y., Ouyang, Y., Yu, G., Liao, Y., & Zhang, Z. (2016) · International Journal of Electrochemical Science · doi:10.20964/2016.08.57 · Cited by 7
Cited by
Theyagarajan, K., & Kim, Y.-J. (2024) · Biosensors · doi:10.3390/bios14100492 · Cited by 31
Metadata
- Authors
- Hassan, M. H., Vyas, C., Grieve, B., & Bartolo, P.
- Venue
- Sensors
- Publisher
- MDPI AG
- Published
- 2021-07-08
- Volume
- 21
- Issue
- 14
- Pages
- 4672
- ISSN
- 1424-8220 (ISSN-L)
- OpenAlex
- W3178439329
- Cited by
- 364
- References
- 182
- FWCI
- 15.48
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.