Abstract

The United States Environmental Protection Agency (US EPA) recently finalized the enforceable maximum contaminant levels for some per- and polyfluoroalkyl substances (PFAS) in drinking water which intends to substantially decrease their level in it. Conventional processes in full-scale drinking water treatment plants (DWTPs) are usually inefficient in PFAS removal from source water (i.e., groundwater and surface water). There is an increasing interest in investigating/evaluating advanced treatment technologies for PFAS removal from PFAS-contaminated water to help generate a number of potential solutions to this water engineering design challenge/problem. While numerous excellent research studies have been carried out and reported in the literature on the efficiency of several treatment processes in removing PFAS from PFAS-contaminated water, mostly at lab- and pilot-scales, full-scale DWTP investigations still need further attention. This study reviews the US EPA’s PFAS water quality guidelines/regulations, remediation technologies for PFAS in water, and PFAS removal studies on full-scale DWTPs. Then, it discusses some configurations of DWTP for PFAS removal from source water (i.e., groundwater and surface water) as well as suggesting future directions. Further research on the effect of environmental factors (e.g., organic matter) on PFAS removal, the effective elimination of short-chain PFAS from real PFAS-contaminated source water using cost-effective and industrially applicable remediation technologies, the efficiency/performance of full-scale treatment trains including innovative advanced technologies in long-term for PFAS removal from source water to produce drinking water and the associated costs, as well as cost reduction/minimization via process optimization is still of interest.

Overview

CoChat Summary

TL;DR

This mini-review compiles US EPA PFAS drinking water regulations, remediation technology classes, and reported PFAS removal performance in full-scale drinking water treatment plants (DWTPs), then proposes simplified DWTP configurations for treating groundwater and surface water. It concludes that GAC adsorption, anion exchange, and high-pressure membranes (NF/RO) are the most viable options, while conventional processes are largely ineffective.

Key findings

  • The US EPA finalized enforceable maximum contaminant levels (April 2024) of 4 ng/L for PFOA and PFOS, and 10 ng/L each for PFHxS, PFNA, and HFPO-DA (GenX); maximum contaminant level goals are 0 ng/L for PFOA and PFOS and 10 ng/L for the others, plus a hazard index of 1 for mixtures of two or more of PFNA, PFHxS, HFPO-DA, and PFBS.
  • Conventional processes (coagulation/flocculation, sedimentation, filtration, oxidation, disinfection) are "mostly ineffective" for PFAS; conventional DWTPs can produce finished water with similar or even higher PFAS concentrations than source water.
  • GAC and anion exchange preferentially remove longer-chain PFAS and perfluorosulfonic acids over perfluorocarboxylic acids, whereas RO removed all studied PFAS including the smallest, PFBA (Appleman et al.). Belkouteb et al. reported average PFAS removal of 92–100% for "young" GAC filters versus 7.0–100% for "old" GAC filters, with lower flow rates increasing removal.
  • Boone et al. reported total concentrations of 17 PFAS across 25 US DWTPs ranging from <1 ng/L to 1102 ng/L, with median totals of 21.4 ng/L (source) and 19.5 ng/L (treated). Other cited full-scale results include 89 ± 22% PFOA and 86 ± 7% PFOS removal (Flores et al.), 98% PFAS removal by NF pilot with 1.4 ng/L total PFAS in permeate (McCleaf et al.), and >90% removal of 35 PFAS by polystyrene-divinylbenzene resins (Liu and Sun).

Methods

  • Design: narrative literature review (mini-review); the paper states no new data were created or analyzed.
  • Scope: US EPA PFAS guidelines/regulations, classification of PFAS remediation technologies (separation/concentration vs. destruction), recent full-scale DWTP removal studies, and proposed DWTP configurations for groundwater and surface water.
  • Analysis: qualitative synthesis of cited studies, presented in Tables 1 and 2 and Figures 1–3; no meta-analysis or primary data collection.

Limitations

  • Stated by the paper: full-scale DWTP investigations still need further attention; further research is needed on environmental factors (e.g., organic matter), elimination of short-chain PFAS and precursors, treatment of PFAS-laden membrane concentrates, long-term full-scale performance, and cost estimation/optimization; proposed configurations require regulatory compliance evaluation and techno-economic study before implementation.
  • Evident from the text: as a mini-review it relies entirely on previously published studies and reports no independent verification; several cited performance figures come from lab- or pilot-scale work (e.g., Soriano et al., McCleaf et al.) rather than full-scale plants; the provided text also contains truncated/garbled table content, limiting reproducibility of some reported values.

Model-written summary. Check it against the paper before relying on it.

Integrity signals

Registry

Crossref · 10.3390/su17020451

Cites

64 of 64 references verified0 citation errors · 0 not checkable

Statistics

Nothing to recompute.

Figures

Figure 1 Some techniques to remediate PFAS in water samples (according to information in Vo et al. [4] and Wanninayake [24]). Figure 1. Some techniques to remediate PFAS in water samples (according to information in Vo et al. [4] and Wanninayake [24]).
Figure 1 Some techniques to remediate PFAS in water samples (according to information in Vo et al. [4] and Wanninayake [24]). Figure 1. Some techniques to remediate PFAS in water samples (according to information in Vo et al. [4] and Wanninayake [24]).CC-BY · From the PDF
Figure 2 The simplified configurations of drinking water treatment plant for PFAS removal from groundwater. Notes: (i) For more information on the processes, see/read the text. (ii) Figure ( A ) is based on reference [6] with a modification (i.e., including ion exchange). (iii) Figure ( B ) is based on reference [53] with a modification (i.e., selecting the technology for treating membrane concentrate based on the concept of references [59,61]). (iv) PFAS regulatory compliance evaluation related to Figure 2. The simplified configurations of drinking water treatment plant for PFAS removal from groundwater. Notes: (i) For more information on the processes, see/read the text. (ii) Figure ( A ) is based on reference [6] with a modification (i.e., including ion exchange). (iii) Figure ( B ) is based on reference [53] with a modification (i.e., selecting the technology for treating membrane concentrate based on the concept of references [59,61]). (iv) PFAS regulatory compliance evaluation related to each configuration and possible modifications are essential before implementation. More techno-economic studies and innovative configurations are still needed.
Figure 2 The simplified configurations of drinking water treatment plant for PFAS removal from groundwater. Notes: (i) For more information on the processes, see/read the text. (ii) Figure ( A ) is based on reference [6] with a modification (i.e., including ion exchange). (iii) Figure ( B ) is based on reference [53] with a modification (i.e., selecting the technology for treating membrane concentrate based on the concept of references [59,61]). (iv) PFAS regulatory compliance evaluation related to Figure 2. The simplified configurations of drinking water treatment plant for PFAS removal from groundwater. Notes: (i) For more information on the processes, see/read the text. (ii) Figure ( A ) is based on reference [6] with a modification (i.e., including ion exchange). (iii) Figure ( B ) is based on reference [53] with a modification (i.e., selecting the technology for treating membrane concentrate based on the concept of references [59,61]). (iv) PFAS regulatory compliance evaluation related to each configuration and possible modifications are essential before implementation. More techno-economic studies and innovative configurations are still needed.CC-BY · From the PDF
Figure 3 The simplified configurations of drinking water treatment plant for PFAS removal from surface water. Note: (i) For more information on the processes, see/read the text. (ii) Figure ( A ) is based on information in reference [3]. (iii) Figure ( B ) is based on reference [49] with modifications (e.g., selecting the technology for treating membrane concentrate based on the concept of references [59,61]). (iv) PFAS regulatory compliance evaluation related to each configuration and possible modifications are essential before implementation. More techno-economic studies and innovative Figure 3. The simplified configurations of drinking water treatment plant for PFAS removal from surface water. Note: (i) For more information on the processes, see/read the text. (ii) Figure ( A ) is based on information in reference [3]. (iii) Figure ( B ) is based on reference [49] with modifications (e.g., selecting the technology for treating membrane concentrate based on the concept of references [59,61]). (iv) PFAS regulatory compliance evaluation related to each configuration and possible modifications are essential before implementation. More techno-economic studies and innovative configurations are still needed.
Figure 3 The simplified configurations of drinking water treatment plant for PFAS removal from surface water. Note: (i) For more information on the processes, see/read the text. (ii) Figure ( A ) is based on information in reference [3]. (iii) Figure ( B ) is based on reference [49] with modifications (e.g., selecting the technology for treating membrane concentrate based on the concept of references [59,61]). (iv) PFAS regulatory compliance evaluation related to each configuration and possible modifications are essential before implementation. More techno-economic studies and innovative Figure 3. The simplified configurations of drinking water treatment plant for PFAS removal from surface water. Note: (i) For more information on the processes, see/read the text. (ii) Figure ( A ) is based on information in reference [3]. (iii) Figure ( B ) is based on reference [49] with modifications (e.g., selecting the technology for treating membrane concentrate based on the concept of references [59,61]). (iv) PFAS regulatory compliance evaluation related to each configuration and possible modifications are essential before implementation. More techno-economic studies and innovative configurations are still needed.CC-BY · From the PDF

Verification

Claims the paper makes

31 Valid · 6 Not valid · 24 Not checked · 2 Own results and interpretations

36 more claims · 20 with their cited sources checked

Create a free account to see all 63 claims and to verify the 2 references still open.

See all claims — free account
  • It may state two separate claims as one. 15
  • Probably not a substantial claim. 9

Create a free account to see these claims.

Citations

Cites

Cited by

See all 27

Metadata

Authors
Jafarinejad, S.
Affiliations
Tuskegee University (US)
Corresponding author
Jafarinejad, Shahryar
Venue
Sustainability
Publisher
MDPI AG
Published
2025-01-09
Volume
17
Issue
2
Pages
451
ISSN
2071-1050 (ISSN-L)
OpenAlex
W4406230486
Cited by
27
References
62
Citations by year
2026: 16 · 2025: 11
FWCI
2.10
Type
journal article
Language
en
Open access
Locations
  • Sustainability (publishedVersion, cc-by)
  • RePEc: Research Papers in Economics (submittedVersion)
Funders
UNCF
Topics
  • Physical Sciences › Environmental Science › Environmental Chemistry › Per- and polyfluoroalkyl substances research
  • Physical Sciences › Environmental Science › Health, Toxicology and Mutagenesis › Water Treatment and Disinfection
  • Physical Sciences › Environmental Science › Environmental Engineering › Environmental remediation with nanomaterials
Keywords
per- and polyfluoroalkyl substances, PFAS removal, drinking water treatment plant, advanced treatment technologies, groundwater contamination, surface water contamination, short-chain PFAS, treatment cost reduction, process optimization

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

The claim verdicts this report counts are experimental: their accuracy is not yet measured.

A language model drew the claims from the paper on 2026-10-11, under version 3 of the claim definition (model deepseek-v4.1-flash, prompt extract-v3).

A second model labelled each claim on 2026-10-11 (model jev-1.13-20260917, definition revision gold-guideline-v0.2).

Cited sources are checked with a language model’s help (gpt-6-sol).

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.