Quantification of Nerve Fiber Layer Thickness in Normal and Glaucomatous Eyes Using Optical Coherence Tomography: A Pilot Study
The DOI matches its Crossref record; 18 of the 18 references it cites were found in a registry or an index.
Abstract
PURPOSE: Quantitative assessment of nerve fiber layer (NFL) thickness in normal and glaucomatous eyes, and correlation with conventional measurements of the optic nerve structure and function. METHODS: We studied 59 eyes of 33 subjects by conventional ophthalmologic physical examination, Humphrey 24-2 visual fields, stereoscopic optic nerve head photography, and optical coherence tomography. RESULTS: Nerve fiber layer thickness as measured by optical coherence tomography demonstrated a high degree of correlation with functional status of the optic nerve, as measured by visual field examination (P = .0001). Neither cupping of the optic nerve nor neuroretinal rim area were as strongly associated with visual field loss as was NFL thickness (P = .17 and P = .21, respectively). Cupping correlated with NFL thickness only when the cup was small (cup-to-diameter ratio, 0.1 to 0.3) or large (cup-to-diameter ratio, 0.8 to 1.0) (P = .006); there was no correlation between cupping and NFL thickness otherwise. Nerve fiber layer, especially in the inferior quadrant, was significantly thinner in glaucomatous eyes than in normal eyes (P = .04). Finally, we found a decrease in NFL thickness with aging, even when controlling for factors associated with the diagnosis of glaucoma (P = .03). CONCLUSIONS: Nerve fiber layer thickness can be measured using optical coherence tomography. These measurements provide good structural and functional correlation with known parameters.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Huang, D., Swanson, E. A., Lin, C. P., Schuman, J. S., Stinson, W. G., Chang, W., Hee, M. R., Flotte, T., Gregory, K., Puliafito, C. A., et al. (1991) · Science · doi:10.1126/science.1957169 · Cited by 13,788
Self-citationMultivariate Statistical Methods
(2008) · Encyclopedia of Public Health · doi:10.1007/978-1-4020-5614-7_2263 · Cited by 5,580
Optical Coherence Tomography of the Human Retina
Hee, M. R. (1995) · Archives of Ophthalmology · doi:10.1001/archopht.1995.01100030081025 · Cited by 1,634
Quigley, H. A. (1982) · Archives of Ophthalmology · doi:10.1001/archopht.1982.01030030137016 · Cited by 1,177
Micrometer-Scale Resolution Imaging of the Anterior Eye In Vivo With Optical Coherence Tomography
Izatt, J. A. (1994) · Archives of Ophthalmology · doi:10.1001/archopht.1994.01090240090031 · Cited by 927
In vivo retinal imaging by optical coherence tomography
Swanson, E. A., Izatt, J. A., Lin, C. P., Fujimoto, J. G., Schuman, J. S., Hee, M. R., Huang, D., & Puliafito, C. A. (1993) · Optics Letters · doi:10.1364/ol.18.001864 · Cited by 918
Self-citationConfocal scanning laser ophthalmoscope
Webb, R. H., Hughes, G. W., & Delori, F. C. (1987) · Applied Optics · doi:10.1364/ao.26.001492 · Cited by 597
The Effect of Age on the Nerve Fiber Population of the Human Optic Nerve
Balazsi, A. G., Rootman, J., Drance, S. M., Schulzer, M., & Douglas, G. R. (1984) · American Journal of Ophthalmology · doi:10.1016/0002-9394(84)90509-9 · Cited by 502
Weinreb, R. N. (1990) · Archives of Ophthalmology · doi:10.1001/archopht.1990.01070060105058 · Cited by 449
Race-, Age-, Gender-, and Refractive Error—Related Differences in the Normal Optic Disc
Varma, R. (1994) · Archives of Ophthalmology · doi:10.1001/archopht.1994.01090200074026 · Cited by 373
Cited by
Weinreb, R. N., & Khaw, P. T. (2004) · The Lancet · doi:10.1016/s0140-6736(04)16257-0 · Cited by 2,222
Jonas, J. B., Aung, T., Bourne, R. R., Bron, A. M., Ritch, R., & Panda-Jonas, S. (2017) · The Lancet · doi:10.1016/s0140-6736(17)31469-1 · Cited by 1,322
Optical Coherence Tomography: An Emerging Technology for Biomedical Imaging and Optical Biopsy
Fujimoto, J. G., Pitris, C., Boppart, S. A., & Brezinski, M. E. (2000) · Neoplasia · doi:10.1038/sj.neo.7900071 · Cited by 1,138
Optical coherence tomography for ultrahigh resolution in vivo imaging
Fujimoto, J. G. (2003) · Nature Biotechnology · doi:10.1038/nbt892 · Cited by 1,033
Ultrahigh-resolution ophthalmic optical coherence tomography
Drexler, W., Morgner, U., Ghanta, R. K., Kärtner, F. X., Schuman, J. S., & Fujimoto, J. G. (2001) · Nature Medicine · doi:10.1038/86589 · Cited by 962
Self-citationIn vivo human retinal imaging by Fourier domain optical coherence tomography
Wojtkowski, M., Leitgeb, R., Kowalczyk, A., Bajraszewski, T., & Fercher, A. F. (2002) · Journal of Biomedical Optics · doi:10.1117/1.1482379 · Cited by 913
State-of-the-art retinal optical coherence tomography
DREXLER, W., & FUJIMOTO, J. (2008) · Progress in Retinal and Eye Research · doi:10.1016/j.preteyeres.2007.07.005 · Cited by 906
Quantitative Assessment of Macular Edema With Optical Coherence Tomography
Hee, M. R. (1995) · Archives of Ophthalmology · doi:10.1001/archopht.1995.01100080071031 · Cited by 710
A framework for comparing structural and functional measures of glaucomatous damage
Hood, D. C., & Kardon, R. H. (2007) · Progress in Retinal and Eye Research · doi:10.1016/j.preteyeres.2007.08.001 · Cited by 703
Determinants of Normal Retinal Nerve Fiber Layer Thickness Measured by Stratus OCT
Budenz, D. L., Anderson, D. R., Varma, R., Schuman, J., Cantor, L., Savell, J., Greenfield, D. S., Patella, V. M., Quigley, H. A., & Tielsch, J. (2007) · Ophthalmology · doi:10.1016/j.ophtha.2006.08.046 · Cited by 684
Self-citationReproducibility of Nerve Fiber Layer Thickness Measurements Using Optical Coherence Tomography
Schuman, J. S., Pedut-Kloizman, T., Hertzmark, E., Hee, M. R., Wilkins, J. R., Coker, J. G., Puliafito, C. A., Fujimoto, J. G., & Swanson, E. A. (1996) · Ophthalmology · doi:10.1016/s0161-6420(96)30410-7 · Cited by 665
Self-citationRelation of Visual Function to Retinal Nerve Fiber Layer Thickness in Multiple Sclerosis
FISHER, J., JACOBS, D., MARKOWITZ, C., GALETTA, S., VOLPE, N., NANOSCHIAVI, M., BAIER, M., FROHMAN, E., WINSLOW, H., & FROHMAN, T. (2006) · Ophthalmology · doi:10.1016/j.ophtha.2005.10.040 · Cited by 658
Medeiros, F. A., Zangwill, L. M., Bowd, C., Vessani, R. M., Susanna, R., & Weinreb, R. N. (2005) · American Journal of Ophthalmology · doi:10.1016/j.ajo.2004.08.069 · Cited by 649
Three-dimensional Retinal Imaging with High-Speed Ultrahigh-Resolution Optical Coherence Tomography
Wojtkowski, M., Srinivasan, V., Fujimoto, J. G., Ko, T., Schuman, J. S., Kowalczyk, A., & Duker, J. S. (2005) · Ophthalmology · doi:10.1016/j.ophtha.2005.05.023 · Cited by 640
Self-citationTopography of diabetic macular edema with optical coherence tomography
Hee, M. R., Puliafito, C. A., Duker, J. S., Reichel, E., Coker, J. G., Wilkins, J. R., Schuman, J. S., Swanson, E. A., & Fujimoto, J. G. (1998) · Ophthalmology · doi:10.1016/s0161-6420(98)93601-6 · Cited by 633
Self-citationTheory, developments and applications of optical coherence tomography
Tomlins, P. H., & Wang, R. K. (2005) · Journal of Physics D: Applied Physics · doi:10.1088/0022-3727/38/15/002 · Cited by 631
Quantifying axonal loss after optic neuritis with optical coherence tomography
Costello, F., Coupland, S., Hodge, W., Lorello, G. R., Koroluk, J., Pan, Y. I., Freedman, M. S., Zackon, D. H., & Kardon, R. H. (2006) · Annals of Neurology · doi:10.1002/ana.20851 · Cited by 610
Optical coherence tomography: a review of clinical development from bench to bedside
Zysk, A. M., Nguyen, F. T., Oldenburg, A. L., Marks, D. L., & Boppart, S. A. (2007) · Journal of Biomedical Optics · doi:10.1117/1.2793736 · Cited by 547
Paunescu, L. A., Schuman, J. S., Price, L. L., Stark, P. C., Beaton, S., Ishikawa, H., Wollstein, G., & Fujimoto, J. G. (2004) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.03-0514 · Cited by 536
Self-citationFercher, A. F. (1996) · Journal of Biomedical Optics · doi:10.1117/12.231361 · Cited by 534
The Development, Commercialization, and Impact of Optical Coherence Tomography
Fujimoto, J., & Swanson, E. (2016) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.16-19963 · Cited by 472
Optical Coherence Tomography of Age-related Macular Degeneration and Choroidal Neovascularization
Hee, M. R., Baumal, C. R., Puliafito, C. A., Duker, J. S., Reichel, E., Wilkins, J. R., Coker, J. G., Schuman, J. S., Swanson, E. A., & Fujimoto, J. G. (1996) · Ophthalmology · doi:10.1016/s0161-6420(96)30512-5 · Cited by 416
Self-citationOptical coherence tomography based angiography [Invited]
Chen, C.-L., & Wang, R. K. (2017) · Biomedical Optics Express · doi:10.1364/boe.8.001056 · Cited by 415
Ultrahigh-resolution full-field optical coherence tomography
Dubois, A., Grieve, K., Moneron, G., Lecaque, R., Vabre, L., & Boccara, C. (2004) · Applied Optics · doi:10.1364/ao.43.002874 · Cited by 394
Characterization of Epiretinal Membranes Using Optical Coherence Tomography
Wilkins, J. R., Puliafito, C. A., Hee, M. R., Duker, J. S., Reichel, E., Coker, J. G., Schuman, J. S., Swanson, E. A., & Fujimoto, J. G. (1996) · Ophthalmology · doi:10.1016/s0161-6420(96)30377-1 · Cited by 390
Self-citationRetinal thickness decreases with age: an OCT study
Alamouti, B. (2003) · British Journal of Ophthalmology · doi:10.1136/bjo.87.7.899 · Cited by 385
Abnormal retinal thickness in patients with mild cognitive impairment and Alzheimer's disease
Paquet, C., Boissonnot, M., Roger, F., Dighiero, P., Gil, R., & Hugon, J. (2007) · Neuroscience Letters · doi:10.1016/j.neulet.2007.02.090 · Cited by 353
Wang, X., Jiang, C., Ko, T., Kong, X., Yu, X., Min, W., Shi, G., & Sun, X. (2015) · Graefe's Archive for Clinical and Experimental Ophthalmology · doi:10.1007/s00417-015-3095-y · Cited by 350
Optical coherence tomography and microscopy in gastrointestinal tissues
Izatt, J. A., Kulkarni, M. D., Wang, H.-W., Kobayashi, K., & Sivak, M. V. (1996) · IEEE Journal of Selected Topics in Quantum Electronics · doi:10.1109/2944.577331 · Cited by 350
Morphological and functional retinal impairment in Alzheimer's disease patients
Parisi, V., Restuccia, R., Fattapposta, F., Mina, C., Bucci, M. G., & Pierelli, F. (2001) · Clinical Neurophysiology · doi:10.1016/s1388-2457(01)00620-4 · Cited by 344
Zangwill, L. M. (2001) · Archives of Ophthalmology · doi:10.1001/archopht.119.7.985 · Cited by 344
Recent developments in optical coherence tomography for imaging the retina
van Velthoven, M. E. J., Faber, D. J., Verbraak, F. D., van Leeuwen, T. G., & de Smet, M. D. (2007) · Progress in Retinal and Eye Research · doi:10.1016/j.preteyeres.2006.10.002 · Cited by 343
Kanamori, A., Nakamura, M., Escano, M. F. T., Seya, R., Maeda, H., & Negi, A. (2003) · American Journal of Ophthalmology · doi:10.1016/s0002-9394(02)02003-2 · Cited by 336
Optical coherence tomography: a window into the mechanisms of multiple sclerosis
Frohman, E. M., Fujimoto, J. G., Frohman, T. C., Calabresi, P. A., Cutter, G., & Balcer, L. J. (2008) · Nature Clinical Practice Neurology · doi:10.1038/ncpneuro0950 · Cited by 326
Normal Age-Related Decay of Retinal Nerve Fiber Layer Thickness
Parikh, R. S., Parikh, S. R., Sekhar, G. C., Prabakaran, S., Babu, J. G., & Thomas, R. (2007) · Ophthalmology · doi:10.1016/j.ophtha.2007.01.023 · Cited by 319
Srinivasan, V. J., Wojtkowski, M., Witkin, A. J., Duker, J. S., Ko, T. H., Carvalho, M., Schuman, J. S., Kowalczyk, A., & Fujimoto, J. G. (2006) · Ophthalmology · doi:10.1016/j.ophtha.2006.05.046 · Cited by 317
Self-citationBlumenthal, E. Z., Williams, J. M., Weinreb, R. N., Girkin, C. A., Berry, C. C., & Zangwill, L. M. (2000) · Ophthalmology · doi:10.1016/s0161-6420(00)00341-9 · Cited by 316
Optical Coherence Tomography: History, Current Status, and Laboratory Work
Gabriele, M. L., Wollstein, G., Ishikawa, H., Kagemann, L., Xu, J., Folio, L. S., & Schuman, J. S. (2011) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.10-6312 · Cited by 310
Self-citationBowd, C. (2000) · Archives of Ophthalmology · doi:10.1001/archopht.118.1.22 · Cited by 308
Scott, C. J. (2010) · Archives of Ophthalmology · doi:10.1001/archophthalmol.2010.94 · Cited by 307
Polarization sensitive optical coherence tomography in the human eye
Pircher, M., Hitzenberger, C. K., & Schmidt-Erfurth, U. (2011) · Progress in Retinal and Eye Research · doi:10.1016/j.preteyeres.2011.06.003 · Cited by 288
Optical coherence tomography of the retina and optic nerve – a review
Sakata, L. M., DeLeon‐Ortega, J., Sakata, V., & Girkin, C. A. (2009) · Clinical & Experimental Ophthalmology · doi:10.1111/j.1442-9071.2009.02015.x · Cited by 264
BARBONI, P., SAVINI, G., VALENTINO, M., MONTAGNA, P., CORTELLI, P., DENEGRI, A., SADUN, F., BIANCHI, S., LONGANESI, L., & ZANINI, M. (2005) · Ophthalmology · doi:10.1016/j.ophtha.2004.06.034 · Cited by 247
Retinal assessment using optical coherence tomography
Costa, R. A., Skaf, M., Melo, L. A. S., Calucci, D., Cardillo, J. A., Castro, J. C., Huang, D., & Wojtkowski, M. (2006) · Progress in Retinal and Eye Research · doi:10.1016/j.preteyeres.2006.03.001 · Cited by 232
“Cross sectional retinal imaging provides a unique opportunity to quantify the overall thickness of the retina in vivo (Huang et al., 1991; Hee et al., 1995a; Schuman et al., 1995; Puliafito et al., 1996; Zeimer et al., 1996; Podoleanu et al., 1998; Bartsch and Freeman, 1994).”
BackgroundMethodSung, K. R., Wollstein, G., Bilonick, R. A., Townsend, K. A., Ishikawa, H., Kagemann, L., Noecker, R. J., Fujimoto, J. G., & Schuman, J. S. (2009) · Ophthalmology · doi:10.1016/j.ophtha.2009.01.004 · Cited by 228
Self-citationCostello, F., Hodge, W., Pan, Y., Eggenberger, E., Coupland, S., & Kardon, R. (2008) · Multiple Sclerosis Journal · doi:10.1177/1352458508091367 · Cited by 227
Ko, T. H., Fujimoto, J. G., Schuman, J. S., Paunescu, L. A., Kowalevicz, A. M., Hartl, I., Drexler, W., Wollstein, G., Ishikawa, H., & Duker, J. S. (2005) · Ophthalmology · doi:10.1016/j.ophtha.2005.05.027 · Cited by 224
Self-citationCense, B., Chen, T. C., Park, B. H., Pierce, M. C., & de Boer, J. F. (2004) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.03-1160 · Cited by 221
“A limitation in RNFL thickness determination by OCT is the axial resolution of approximately 10 m with conventional OCT systems.(3) The difference between high-resolution optical coherence tomography (HR-OCT) and conventional OCT is that HR-OCT uses a light source with a particularly large optical bandwidth, allowing…”
BackgroundRetinal Nerve Fiber Layer Thickness in Normal Human Eyes
Varma, R., Skaf, M., & Barron, E. (1996) · Ophthalmology · doi:10.1016/s0161-6420(96)30381-3 · Cited by 219
Strouthidis, N. G., Fortune, B., Yang, H., Sigal, I. A., & Burgoyne, C. F. (2011) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.10-5599 · Cited by 210
Hood, D. C., Lin, C. E., Lazow, M. A., Locke, K. G., Zhang, X., & Birch, D. G. (2009) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.08-2936 · Cited by 209
“With a relatively new noninvasive technique, time-domain optical coherence tomography (tdOCT), in vivo measurement of the retinal nerve fiber layer (RNFL) thickness can now be made.(8,9) Using tdOCT technology, Walia et al.”
Hood, D. C., Fortune, B., Arthur, S. N., Xing, D., Salant, J. A., Ritch, R., & Liebmann, J. M. (2008) · Journal of Glaucoma · doi:10.1097/ijg.0b013e3181629a02 · Cited by 207
“A computer algorithm then identifies the anterior and posterior boundaries of the highly reflective RNFL to provide an estimate of its thickness.(2,4) The images in Figure 1 were taken from a clinical report of RNFL thickness provided by a commercially available OCT instrument.”
MethodOptical Coherence Tomography in Alzheimer’s Disease: A Meta-Analysis
Coppola, G., Di Renzo, A., Ziccardi, L., Martelli, F., Fadda, A., Manni, G., Barboni, P., Pierelli, F., Sadun, A. A., & Parisi, V. (2015) · PLOS ONE · doi:10.1371/journal.pone.0134750 · Cited by 205
Medeiros, F. A., Zangwill, L. M., Alencar, L. M., Bowd, C., Sample, P. A., Susanna, R., & Weinreb, R. N. (2009) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.09-3715 · Cited by 204
Knight, O. J., Chang, R. T., Feuer, W. J., & Budenz, D. L. (2009) · Ophthalmology · doi:10.1016/j.ophtha.2008.12.032 · Cited by 199
“An automated segmentation algorithm, based on reflectivity changes between adjacent retinal layers, calculates the retinal nerve fiber layer (RNFL) thickness.(2) OCT has been shown to be a highly reproducible imaging modality and to correlate positively with ex vivo histologic measurements of the retina.”
Diagnostic Tools for Glaucoma Detection and Management
Sharma, P., Sample, P. A., Zangwill, L. M., & Schuman, J. S. (2008) · Survey of Ophthalmology · doi:10.1016/j.survophthal.2008.08.003 · Cited by 198
Self-citationCense, B., Chen, T. C., Park, B. H., Pierce, M. C., & de Boer, J. F. (2002) · Optics Letters · doi:10.1364/ol.27.001610 · Cited by 182
Wang, Y., Bower, B. A., Izatt, J. A., Tan, O., & Huang, D. (2008) · Journal of Biomedical Optics · doi:10.1117/1.2998480 · Cited by 182
Identifying early glaucoma with optical coherence tomography
Nouri-Mahdavi, K., Hoffman, D., Tannenbaum, D. P., Law, S. K., & Caprioli, J. (2004) · American Journal of Ophthalmology · doi:10.1016/j.ajo.2003.09.004 · Cited by 172
The Nature of Macular Damage in Glaucoma as Revealed by Averaging Optical Coherence Tomography Data
Hood, D. C., Raza, A. S., de Moraes, C. G. V., Johnson, C. A., Liebmann, J. M., & Ritch, R. (2012) · Translational Vision Science & Technology · doi:10.1167/tvst.1.1.3 · Cited by 171
The Cellular Origins of the Outer Retinal Bands in Optical Coherence Tomography Images
Jonnal, R. S., Kocaoglu, O. P., Zawadzki, R. J., Lee, S.-H., Werner, J. S., & Miller, D. T. (2014) · Investigative Ophthalmology & Visual Science · doi:10.1167/iovs.14-14907 · Cited by 169
Lalezary, M., Medeiros, F. A., Weinreb, R. N., Bowd, C., Sample, P. A., Tavares, I. M., Tafreshi, A., & Zangwill, L. M. (2006) · American Journal of Ophthalmology · doi:10.1016/j.ajo.2006.05.004 · Cited by 160
Metadata
- Authors
- Schuman, J. S.
- Venue
- Archives of Ophthalmology
- Publisher
- American Medical Association (AMA)
- Published
- 1995-05-01
- Volume
- 113
- Issue
- 5
- Pages
- 586
- ISSN
- 0003-9950 (ISSN-L)
- OpenAlex
- W2076673551
- Cited by
- 879
- References
- 18
- FWCI
- 25.54
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.