The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Human plasma fibrinogen adsorption and platelet adhesion to polystyrene
Abstract
The purpose of this study was to further investigate the role of fibrinogen adsorbed from plasma in mediating platelet adhesion to polymeric biomaterials. Polystyrene was used as a model hydrophobic polymer; i.e., we expected that the role of fibrinogen in platelet adhesion to polystyrene would be representative of other hydrophobic polymers. Platelet adhesion was compared to both the amount and conformation of adsorbed fibrinogen. The strategy was to compare platelet adhesion to surfaces preadsorbed with normal, afibrinogenemic, and fibrinogen-replenished afibrinogenemic plasmas. Platelet adhesion was determined by the lactate dehydrogenase (LDH) method, which was found to be closely correlated with adhesion of 111In-labeled platelets. Fibrinogen adsorption from afibrinogenemic plasma to polystyrene (Immulon I(R)) was low and <10 ng/cm2. Platelet adhesion was absent on surfaces preadsorbed with afibrinogenemic plasma when the residual fibrinogen was low enough (<60 microg/mL). Platelet adhesion was restored on polystyrene preadsorbed with fibrinogen-replenished afibrinogenemic plasma. Addition of even small, subnormal concentrations of fibrinogen to afibrinogenemic plasma greatly increased platelet adhesion. In addition, surface-bound fibrinogen's ability to mediate platelet adhesion was different, depending on the plasma concentration from which fibrinogen was adsorbed. These differences correlated with changes in the binding of a monoclonal antibody that binds to the Aalpha chain RGDS (572-575), suggesting alteration in the conformation or orientation of the adsorbed fibrinogen. Platelet adhesion to polystyrene preadsorbed with blood plasma thus appears to be a strongly bivariate function of adsorbed fibrinogen, responsive to both low amounts and altered states of the adsorbed molecule.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Secretory products of macrophages.
Nathan, C. F. (1987) · Journal of Clinical Investigation · doi:10.1172/jci112815 · Cited by 2,615
Zhao, Q., Topham, N., Anderson, J. M., Hiltner, A., Lodoen, G., & Payet, C. R. (1991) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820250205 · Cited by 318
Self-citationBELLOWS, C. G., AUBIN, J. E., & HEERSCHE, J. N. M. (1987) · Endocrinology · doi:10.1210/endo-121-6-1985 · Cited by 306
Interleukin-13 induces human monocyte/macrophage fusion and macrophage mannose receptor expression
DeFife, K. M., Jenney, C. R., McNally, A. K., Colton, E., & Anderson, J. M. (1997) · The Journal of Immunology · doi:10.4049/jimmunol.158.7.3385 · Cited by 228
Self-citationHolland, J. W., Hui, C., Cullis, P. R., & Madden, T. D. (1996) · Biochemistry · doi:10.1021/bi952000v · Cited by 223
Cell culture methods for testing Biocompatibility
Pizzoferrato, A., Ciapetti, G., Stea, S., Cenni, E., Arciola, C. R., Granchi, D., & Lucia (1994) · Clinical Materials · doi:10.1016/0267-6605(94)90081-7 · Cited by 207
Kao, W. J., Zhao, Q. H., Hiltner, A., & Anderson, J. M. (1994) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820280110 · Cited by 85
Self-citation
Cited by
Hydrogels for tissue engineering: scaffold design variables and applications
Drury, J. L., & Mooney, D. J. (2003) · Biomaterials · doi:10.1016/s0142-9612(03)00340-5 · Cited by 5,136
A Survey of Structure−Property Relationships of Surfaces that Resist the Adsorption of Protein
Ostuni, E., Chapman, R. G., Holmlin, R. E., Takayama, S., & Whitesides, G. M. (2001) · Langmuir · doi:10.1021/la010384m · Cited by 1,799
Conducting polymers in biomedical engineering
Guimard, N. K., Gomez, N., & Schmidt, C. E. (2007) · Progress in Polymer Science · doi:10.1016/j.progpolymsci.2007.05.012 · Cited by 1,599
Biological Responses to Materials
Anderson, J. M. (2001) · Annual Review of Materials Research · doi:10.1146/annurev.matsci.31.1.81 · Cited by 1,465
Gorbet, M. B., & Sefton, M. V. (2004) · Biomaterials · doi:10.1016/j.biomaterials.2004.01.023 · Cited by 1,347
Macrophages, Foreign Body Giant Cells and Their Response to Implantable Biomaterials
Sheikh, Z., Brooks, P., Barzilay, O., Fine, N., & Glogauer, M. (2015) · Materials · doi:10.3390/ma8095269 · Cited by 701
Wong, T. Y., Preston, L. A., & Schiller, N. L. (2000) · Annual Review of Microbiology · doi:10.1146/annurev.micro.54.1.289 · Cited by 669
Biosensors for real-time in vivo measurements
Wilson, G. S., & Gifford, R. (2005) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2004.12.003 · Cited by 660
Nanomaterials for Neural Interfaces
Kotov, N. A., Winter, J. O., Clements, I. P., Jan, E., Timko, B. P., Campidelli, S., Pathak, S., Mazzatenta, A., Lieber, C. M., Prato, M., et al. (2009) · Advanced Materials · doi:10.1002/adma.200801984 · Cited by 504
Fedorovich, N. E., Alblas, J., de Wijn, J. R., Hennink, W. E., Verbout, A. J., & Dhert, W. J. A. (2007) · Tissue Engineering · doi:10.1089/ten.2006.0175 · Cited by 467
Molecular basis of biomaterial-mediated foreign body reactions
Hu, W.-J., Eaton, J. W., Ugarova, T. P., & Tang, L. (2001) · Blood · doi:10.1182/blood.v98.4.1231 · Cited by 431
Proteins, platelets, and blood coagulation at biomaterial interfaces
Xu, L.-C., Bauer, J. W., & Siedlecki, C. A. (2014) · Colloids and Surfaces B: Biointerfaces · doi:10.1016/j.colsurfb.2014.09.040 · Cited by 391
Anderson, J. M. (2000) · Current Opinion in Hematology · doi:10.1097/00062752-200001000-00008 · Cited by 386
Gomez, N., & Schmidt, C. E. (2007) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.31047 · Cited by 306
Kim, D. ‐., Richardson‐Burns, S. M., Hendricks, J. L., Sequera, C., & Martin, D. C. (2007) · Advanced Functional Materials · doi:10.1002/adfm.200500594 · Cited by 299
Biocompatibility of implants: lymphocyte/macrophage interactions
Anderson, J. M., & McNally, A. K. (2011) · Seminars in Immunopathology · doi:10.1007/s00281-011-0244-1 · Cited by 226
Self-citationRUHE, Q. P., HEDBERG, E. L., PADRON, N. T., SPAUWEN, P. H. M., JANSEN, J. A., & MIKOS, A. G. (2003) · The Journal of Bone and Joint Surgery-American Volume · doi:10.2106/00004623-200300003-00013 · Cited by 186
Ward, W. K., Slobodzian, E. P., Tiekotter, K. L., & Wood, M. D. (2002) · Biomaterials · doi:10.1016/s0142-9612(02)00160-6 · Cited by 176
Hydrogels for Musculoskeletal Tissue Engineering
Varghese, S., & Elisseeff, J. H. (2006) · Advances in Polymer Science · doi:10.1007/12_072 · Cited by 173
Excess iron inhibits osteoblast metabolism
Yamasaki, K., & Hagiwara, H. (2009) · Toxicology Letters · doi:10.1016/j.toxlet.2009.08.023 · Cited by 168
Cui, X., & Martin, D. C. (2003) · Sensors and Actuators A: Physical · doi:10.1016/s0924-4247(02)00427-2 · Cited by 160
McNally, A. K., Jones, J. A., MacEwan, S. R., Colton, E., & Anderson, J. M. (2008) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.31658 · Cited by 139
Quantitative in vivo cytokine analysis at synthetic biomaterial implant sites
Rodriguez, A., Meyerson, H., & Anderson, J. M. (2009) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.31939 · Cited by 111
Elastic Anisotropy of Human Cortical Bone Secondary Osteons Measured by Nanoindentation
Franzoso, G., & Zysset, P. K. (2009) · Journal of Biomechanical Engineering · doi:10.1115/1.3005162 · Cited by 89
Ultrasonic-activated micellar drug delivery for cancer treatment
Husseini, G. A., & Pitt, W. G. (2009) · Journal of Pharmaceutical Sciences · doi:10.1002/jps.21444 · Cited by 83
Self-citationTemporal progression of the host response to implanted poly(ethylene glycol)‐based hydrogels
Lynn, A. D., Blakney, A. K., Kyriakides, T. R., & Bryant, S. J. (2011) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.33015 · Cited by 77
The role of osteopontin in foreign body giant cell formation
Tsai, A. T., Rice, J., Scatena, M., Liaw, L., Ratner, B. D., & Giachelli, C. M. (2005) · Biomaterials · doi:10.1016/j.biomaterials.2005.03.003 · Cited by 71
Macrophage behavior on surface-modified polyurethanes
Jones, J. A., Dadsetan, M., Collier, T. O., Ebert, M., Stokes, K. S., Ward, R. S., Hiltner, P. A., & Anderson, J. M. (2004) · Journal of Biomaterials Science, Polymer Edition · doi:10.1163/156856204323046843 · Cited by 70
α subunit partners to β1 and β2 integrins during IL‐4‐induced foreign body giant cell formation
McNally, A. K., MacEwan, S. R., & Anderson, J. M. (2007) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.31161 · Cited by 57
Local strain and damage mapping in single trabeculae during three-point bending tests
Jungmann, R., Szabo, M. E., Schitter, G., Yue-Sing Tang, R., Vashishth, D., Hansma, P. K., & Thurner, P. J. (2011) · Journal of the Mechanical Behavior of Biomedical Materials · doi:10.1016/j.jmbbm.2010.12.009 · Cited by 57
Wu, Y., Zhou, Z., & Meyerhoff, M. E. (2007) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.31105 · Cited by 48
The Role of Macrophages in the Foreign Body Response to Implanted Biomaterials
Yu, T., Tutwiler, V. J., & Spiller, K. (2015) · Biomaterials in Regenerative Medicine and the Immune System · doi:10.1007/978-3-319-18045-8_2 · Cited by 39
Ebert, M., Ward, B., Anderson, J., McVenes, R., & Stokes, K. (2005) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.30396 · Cited by 26
Metadata
- Authors
- Tsai, W.-B., Grunkemeier, J. M., & Horbett, T. A.
- Venue
- Journal of Biomedical Materials Research
- Publisher
- Wiley
- Published
- 1999-02
- Volume
- 44
- Issue
- 2
- Pages
- 130-139
- ISSN
- 0021-9304 (ISSN-L)
- 1097-4636
- OpenAlex
- W1990312664
- Cited by
- 329
- References
- 7
- FWCI
- 7.72
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.