Electroencephalography (EEG)‐Based Brain–Computer Interfaces
The DOI matches its Crossref record; 34 of the 34 references it cites were found in a registry or an index.
Abstract
Brain–computer interfaces (BCIs) are systems that can translate the brain activity patterns of a user into messages or commands for an interactive application. The brain activity that is processed by the BCI systems is usually measured using electroencephalography (EEG). In this article, we aim at providing an accessible and up‐to‐date overview of EEG‐based BCI, with a main focus on its engineering aspects. We notably introduce some basic neuroscience background, and explain how to design an EEG‐based BCI, in particular reviewing which signal processing, machine learning, and software and hardware tools to use. We present BCI applications, highlight some limitations of current systems, and suggest some perspectives for the field.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Brain–computer interfaces for communication and control
Wolpaw, J. R., Birbaumer, N., McFarland, D. J., Pfurtscheller, G., & Vaughan, T. M. (2002) · Clinical Neurophysiology · doi:10.1016/s1388-2457(02)00057-3 · Cited by 7,927 · cited 2×
“A BCI is a system that translates the brain activity patterns of a user into messages or commands for an interactive application, this activity being measured and processed by the system [5, 6].”
BackgroundEvent-related EEG/MEG synchronization and desynchronization: basic principles
Pfurtscheller, G., & Lopes da Silva, F. H. (1999) · Clinical Neurophysiology · doi:10.1016/s1388-2457(99)00141-8 · Cited by 7,328 · cited 3×
“ERD and ERS have been suggested to reflect cortical activation and deactivation, respectively [36].”
BackgroundMethodInfluentialFeigin, V. L., Forouzanfar, M. H., Krishnamurthi, R., Mensah, G. A., Connor, M., Bennett, D. A., Moran, A. E., Sacco, R. L., Anderson, L., Truelsen, T., et al. (2014) · The Lancet · doi:10.1016/s0140-6736(13)61953-4 · Cited by 3,899
Farwell, L. A., & Donchin, E. (1988) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(88)90149-6 · Cited by 3,228
Solving Multiclass Learning Problems via Error-Correcting Output Codes
Dietterich, T. G., & Bakiri, G. (1995) · Journal of Artificial Intelligence Research · doi:10.1613/jair.105 · Cited by 2,739
Reach and grasp by people with tetraplegia using a neurally controlled robotic arm
Hochberg, L. R., Bacher, D., Jarosiewicz, B., Masse, N. Y., Simeral, J. D., Vogel, J., Haddadin, S., Liu, J., Cash, S. S., van der Smagt, P., et al. (2012) · Nature · doi:10.1038/nature11076 · Cited by 2,719 · cited 1×
“Using multielectrode arrays placed invasively in the primary motor cortex, it is possible to decode the direction of movement from the activity of a neural population [108] and send commands to a robotic limb or an exoskeleton to reach and grasp a target [109].”
BackgroundA review of classification algorithms for EEG-based brain–computer interfaces
Lotte, F., Congedo, M., Lécuyer, A., Lamarche, F., & Arnaldi, B. (2007) · Journal of Neural Engineering · doi:10.1088/1741-2560/4/2/r01 · Cited by 2,665
Self-citationOptimal spatial filtering of single trial EEG during imagined hand movement
Ramoser, H., Muller-Gerking, J., & Pfurtscheller, G. (2000) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/86.895946 · Cited by 2,457
Optimizing Spatial filters for Robust EEG Single-Trial Analysis
Blankertz, B., Tomioka, R., Lemm, S., Kawanabe, M., & Muller, K.-R. (2008) · IEEE Signal Processing Magazine · doi:10.1109/msp.2008.4408441 · Cited by 2,080 · cited 4×
“For EEG signal classification, spatial filtering is one of the most efficient and popular approaches [68].”
BackgroundMethodInfluentialMotor imagery and direct brain-computer communication
Pfurtscheller, G., & Neuper, C. (2001) · Proceedings of the IEEE · doi:10.1109/5.939829 · Cited by 1,990
A spelling device for the paralysed
Birbaumer, N., Ghanayim, N., Hinterberger, T., Iversen, I., Kotchoubey, B., Kübler, A., Perelmouter, J., Taub, E., & Flor, H. (1999) · Nature · doi:10.1038/18581 · Cited by 1,577 · cited 2×
“Since the design of the first real-time BCI in the 90’s [7, 8, 9, 10], the BCI field has grown tremendously, involving hundreds of laboratories and companies around the world, and becoming a more mature field of research and technology [11, 6].”
BackgroundFilter Bank Common Spatial Pattern Algorithm on BCI Competition IV Datasets 2a and 2b
Ang, K. K., Chin, Z. Y., Wang, C., Guan, C., & Zhang, H. (2012) · Frontiers in Neuroscience · doi:10.3389/fnins.2012.00039 · Cited by 1,264 · cited 1×
“As such, many CSP variants have been designed to make it more robust to noise and non-stationarities [74, 75], or to enable it to optimise both spatial and spectral filters at the same time [76, 77].”
BackgroundDuncan, C. C., Barry, R. J., Connolly, J. F., Fischer, C., Michie, P. T., Näätänen, R., Polich, J., Reinvang, I., & Van Petten, C. (2009) · Clinical Neurophysiology · doi:10.1016/j.clinph.2009.07.045 · Cited by 1,191
Brain–computer interfaces in neurological rehabilitation
Daly, J. J., & Wolpaw, J. R. (2008) · The Lancet Neurology · doi:10.1016/s1474-4422(08)70223-0 · Cited by 1,149 · cited 2×
“…indeed evolved to become more robust, more accessible and promising for a wide range of applications including communication and control for motor impaired users [9, 12], gaming targeted toward the general public [13, 14], real-time mental state monitoring [15] or stroke rehabilitation [16, 17].”
BackgroundSteady-state visually evoked potentials: Focus on essential paradigms and future perspectives
Vialatte, F.-B., Maurice, M., Dauwels, J., & Cichocki, A. (2010) · Progress in Neurobiology · doi:10.1016/j.pneurobio.2009.11.005 · Cited by 1,066 · cited 2×
“Various kinds of SSEP are used for BCI, such as Steady State Visual Evoked Potentials (SSVEP) [46, 47], somatosensory SSEP [48] or auditory SSEP [49].”
BackgroundMethodBashashati, A., Fatourechi, M., Ward, R. K., & Birch, G. E. (2007) · Journal of Neural Engineering · doi:10.1088/1741-2560/4/2/r03 · Cited by 907
Renard, Y., Lotte, F., Gibert, G., Congedo, M., Maby, E., Delannoy, V., Bertrand, O., & Lécuyer, A. (2010) · Presence: Teleoperators and Virtual Environments · doi:10.1162/pres.19.1.35 · Cited by 830 · cited 1×
“The two most widely used are BCI2000 [160] ( http://bci2000.org ) and OpenViBE [161] ( http://openvibe.inria.fr ).”
Self-citationA comparison of classification techniques for the P300 Speller
Krusienski, D. J., Sellers, E. W., Cabestaing, F., Bayoudh, S., McFarland, D. J., Vaughan, T. M., & Wolpaw, J. R. (2006) · Journal of Neural Engineering · doi:10.1088/1741-2560/3/4/007 · Cited by 762
How many people are able to control a P300-based brain-computer interface (BCI)?
Guger, C., Daban, S., Sellers, E., Holzner, C., Krausz, G., Carabalona, R., Gramatica, F., & Edlinger, G. (2009) · Neuroscience Letters · doi:10.1016/j.neulet.2009.06.045 · Cited by 652
Townsend, G., LaPallo, B. K., Boulay, C. B., Krusienski, D. J., Frye, G. E., Hauser, C. K., Schwartz, N. E., Vaughan, T. M., Wolpaw, J. R., & Sellers, E. W. (2010) · Clinical Neurophysiology · doi:10.1016/j.clinph.2010.01.030 · Cited by 570
Pfurtscheller, G., Müller, G. R., Pfurtscheller, J., Gerner, H. J., & Rupp, R. (2003) · Neuroscience Letters · doi:10.1016/s0304-3940(03)00947-9 · Cited by 548
xDAWN Algorithm to Enhance Evoked Potentials: Application to Brain–Computer Interface
Rivet, B., Souloumiac, A., Attina, V., & Gibert, G. (2009) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2009.2012869 · Cited by 537 · cited 3×
“One of them is the xDAWN spatial filter [80].”
BackgroundHow many people are able to operate an EEG-based brain-computer interface (BCI)?
Guger, C., Edlinger, G., Harkam, W., Niedermayer, I., & Pfurtscheller, G. (2003) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2003.814481 · Cited by 526
A Hybrid BCI System Combining P300 and SSVEP and Its Application to Wheelchair Control
Li, Y., Pan, J., Wang, F., & Yu, Z. (2013) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2013.2270283 · Cited by 421 · cited 3×
“Multiple such signals can be combined together, e.g., to control a wheelchair based on both P300 and SSVEP [50], or combined with other control signals not originating from the brain, such as eye trackers or joysticks [53, 54].”
BackgroundMethodEstimating workload using EEG spectral power and ERPs in the n-back task
Brouwer, A.-M., Hogervorst, M. A., van Erp, J. B. F., Heffelaar, T., Zimmerman, P. H., & Oostenveld, R. (2012) · Journal of Neural Engineering · doi:10.1088/1741-2560/9/4/045008 · Cited by 407 · cited 1×
“Indeed, a number of interesting mental states can be estimated, more-or-less reliably, in EEG signals, such as mental workload (i.e., pressure on the user cognitive resources, e.g., working memory) [145, 146], attention [142, 147] and, though less accurately, emotions [148], among others [149].”
BackgroundA brain-computer interface for long-term independent home use
Sellers, E. W., Vaughan, T. M., & Wolpaw, J. R. (2010) · Amyotrophic Lateral Sclerosis · doi:10.3109/17482961003777470 · Cited by 400 · cited 1×
“Several clinical studies have indeed demonstrated the usability of the spellers [104, 99], for patients who are able to maintain a sustained attention [105], and regular home use has been reported [106].”
BackgroundBrain-Computer Interfaces: Beyond Medical Applications
van Erp, J., Lotte, F., & Tangermann, M. (2012) · Computer · doi:10.1109/mc.2012.107 · Cited by 362
Self-citationThe Berlin Brain–Computer Interface: Non-Medical Uses of BCI Technology
Blankertz, B., Tangermann, M., Vidaurre, C., Fazli, S., Sannelli, C., Haufe, S., Maeder, C., Ramsey, L., Sturm, I., Curio, G., et al. (2010) · Frontiers in Neuroscience · doi:10.3389/fnins.2010.00198 · Cited by 357
Lotte, F. (2015) · Proceedings of the IEEE · doi:10.1109/jproc.2015.2404941 · Cited by 327 · cited 2×
“EEG-based BCI also generally require relatively long calibration time [24] and may also require long to very long human training time [22, 33].”
BackgroundSelf-citationLotte, F., Larrue, F., & Mühl, C. (2013) · Frontiers in Human Neuroscience · doi:10.3389/fnhum.2013.00568 · Cited by 307
Self-citationMotor imagery classification by means of source analysis for brain–computer interface applications
Qin, L., Ding, L., & He, B. (2004) · Journal of Neural Engineering · doi:10.1088/1741-2560/1/3/002 · Cited by 239
Schultz, A. E., & Kuiken, T. A. (2011) · PM&R · doi:10.1016/j.pmrj.2010.06.016 · Cited by 186 · cited 1×
“A neuroprosthesis is a prosthesis attached to the (central or peripheral) nervous system [107].”
BackgroundHow Many People Could Use an SSVEP BCI?
Guger, C., Allison, B. Z., Großwindhager, B., Prückl, R., Hintermüller, C., Kapeller, C., Bruckner, M., Krausz, G., & Edlinger, G. (2012) · Frontiers in Neuroscience · doi:10.3389/fnins.2012.00169 · Cited by 176 · cited 2×
“SSEP are defined by an increase of the EEG power at the frequency of the stimulus (e.g., the flickering frequency of the picture or the modulation frequency of the sound) or at its harmonics or sub-harmonics [46, 47, 27].”
BackgroundAttention and P300-based BCI performance in people with amyotrophic lateral sclerosis
Riccio, A., Simione, L., Schettini, F., Pizzimenti, A., Inghilleri, M., Belardinelli, M. O., Mattia, D., & Cincotti, F. (2013) · Frontiers in Human Neuroscience · doi:10.3389/fnhum.2013.00732 · Cited by 162
Research works printed but not linked: 130
- 10.1007/BF01797193 · DOI · Paper page
- Henry P., Mise en musique du corticalart de Roger Lafosse, Philips Prospective 21e sicle
- 10.1146/annurev.bb.02.060173.001105 · DOI · Paper page
- Wolpaw J. R., 2012, BCI: Principles and Practice
- 10.1016/0013-4694(91)90040-B · DOI · Paper page
- 10.1006/jmca.1993.1030 · DOI · Paper page
- 10.1007/978-3-642-02091-9 · DOI · Paper page
- Millàn J. R., 2010, Combining Brain–Computer Interfaces and Assistive Technologies: State‐of‐the‐Art and Challenges, Front. Neuropros., 4, 161
- 10.1109/MC.2008.410 · DOI · Paper page
- 10.1109/TCIAIG.2013.2264736 · DOI · Paper page
- 10.1088/1741-2560/8/2/025005 · DOI · Paper page
- 10.5626/JCSE.2013.7.2.139 · DOI · Paper page
- 10.1109/TNSRE.2006.875583 · DOI
- 10.1109/TNSRE.2006.875585 · DOI · Paper page
- Neuper C., 2010, Brain–Computer Interfaces, 65
- 10.1088/1741-2560/11/3/035005 · DOI · Paper page
- Allison B. Z., 2010, Brain–Computer Interfaces, 35, 10.1007/978-1-84996-272-8_3 · DOI · Paper page
- S.Brandl J.Höhne K.‐R.Müller andWSamek. Bringing BCI into Everyday Life: Motor Imagery in a Pseudo Realistic Environment inProc. of the International IEEE/EMBS Neural Engineering Conference (NER);2015. · DOI
- 10.1016/j.clinph.2006.10.019 · DOI · Paper page
- F.Lotte J.Fujisawa H.Touyama R.Ito M.Hirose andA.Lécuyer. Towards Ambulatory Brain–Computer Interfaces: A Pilot Study with P300 Signals in5th Advances in Computer Entertainment Technology Conference (ACE)2009 pp336–339. · DOI
- 10.1109/TNSRE.2003.814431 · DOI · Paper page
- F.LotteandC.Jeunet. Towards Improved BCI Based on Human Learning Principles in3rd International Brain–Computer Interfaces Winter Conference 2015. · DOI · Paper page
- Niedermeyer E., 2005, Electroencephalography: Basic Principles, Clinical Applications, and Related Fields
- Jasper H. H., 1958, The Ten–Twenty Electrode System of the International Federation, Electroencephalogr. Clin. Neurophysiol., 10, 371
- 10.1016/j.clinph.2012.11.010 · DOI
- 10.1109/TNN.2002.1000132 · DOI · Paper page
- 10.1109/TNSRE.2007.891389 · DOI
- 10.1038/2031155a0 · DOI · Paper page
- 10.1016/j.clinph.2007.04.019 · DOI · Paper page
- 10.3389/fnins.2014.00208 · DOI · Paper page
- 10.1016/S1388-2457(00)00457-0 · DOI · Paper page
- 10.1109/TNSRE.2005.863842 · DOI · Paper page
- Gouy‐Pailler C., 2007, Topographical Dynamics of Brain Connections for the Design of Asynchronous Brain–Computer Interfaces, Conf. Proc. IEEE Eng. Med. Biol. Soc., 2007, 2520
- 10.1109/TNSRE.2009.2039594 · DOI · Paper page
- Martinez P., 2007, Fully Online Multicommand Brain–Computer Interface with Visual Neurofeedback Using SSVEP Paradigm, Comput. Intell. Neurosci., 1, 94561
- 10.1109/TCIAIG.2012.2230003 · DOI
- 10.1109/TCIAIG.2013.2242072 · DOI
- Pfurtscheller G., 2010, The Hybrid BCI, Front. Neurosci., 4, 3
- 10.1109/JPROC.2015.2411333 · DOI · Paper page
- 10.1016/j.clinph.2006.09.003 · DOI · Paper page
- 10.1109/79.962275 · DOI · Paper page
- 10.1088/0031-9155/51/8/002 · DOI · Paper page
- 10.1016/S0013-4694(97)00022-2 · DOI · Paper page
- Nunez P. L., 2005, Electric Fields of the Brain: The Neurophysics of EEG
- 10.1109/TNSRE.2008.926694 · DOI · Paper page
- N.Brodu F.Lotte andA.Lécuyer. Comparative Study of Band‐Power Extraction Techniques for Motor Imagery Classification. In2011 IEEE Symposium on Computational Intelligence Cognitive Algorithms Mind and Brain (CCMB) IEEE 2011 pp1–6. · DOI
- 10.1007/s10548-010-0135-0 · DOI
- 10.1109/TBME.2011.2131142 · DOI · Paper page
- 10.1162/153244303322753616 · DOI · Paper page
- 10.1109/TBME.2008.921154 · DOI · Paper page
- 10.1016/j.neuroimage.2013.10.067 · DOI · Paper page
- M.Grosse‐Wentrup. Understanding Brain Connectivity Patterns During Motor Imagery for Brain–Computer Interfacing. InAdvances in Neural Information Processing Systems (NIPS) 21 2009.
- 10.1109/TBME.2010.2082539 · DOI · Paper page
- 10.1109/RBME.2013.2290621 · DOI · Paper page
- 10.1109/TBME.2005.851521 · DOI · Paper page
- U.Hoffmann J.Vesin andT.Ebrahimi. Spatial Filters for the Classification of Event‐Related Potentials. InEuropean Symposium on Artificial Neural Networks (ESANN 2006) 2006.
- 10.4018/jdwm.2007070101 · DOI · Paper page
- 10.1016/j.patcog.2012.03.004 · DOI · Paper page
- 10.1214/aos/1028144844 · DOI · Paper page
- 10.1162/15324430152733133 · DOI
- 10.1006/jmps.1999.1279 · DOI · Paper page
- 10.1016/j.neuroimage.2009.07.045 · DOI · Paper page
- 10.1523/JNEUROSCI.6107-09.2010 · DOI · Paper page
- 10.1371/journal.pone.0061976 · DOI
- 10.1088/1741-2560/10/3/031001 · DOI · Paper page
- 10.1088/1741-2560/10/3/031001 · DOI · Paper page
- 10.3389/fneng.2012.00014 · DOI · Paper page
- 10.1109/86.662615 · DOI · Paper page
- 10.1371/journal.pone.0049688 · DOI
- M.Perrin E.Maby O.Bertrand andJ.Mattout. A Virtuous BCI Loop: Adaptive Decision‐Making Improves P300‐Spelling in Two Ways. InProc. of the 6th International Brain–Computer Interface Conference 2014.
- E.Thomas E.Daucé D.Devlaminck L.Mahé A.Carpentier R.Munos M.Perrin E.Maby J.Mattout T.Papadopoulo andM.Clerc. CoAdapt P300 Speller: Optimized Ashing Sequences and Online Learning. InProc. of the 6th International Brain–Computer Interface Conference 2014.
- 10.1088/1741-2560/12/1/016013 · DOI
- 10.1080/10447318.2011.535754 · DOI
- B.Blankertz G.Dornhege M.Krauledat M.Schröder J.Williamson R.Murray‐Smith andK. R.Müller. The Berlin Brain–Computer Interface Presents the Novel Mental Typewriter Hex‐o‐Spell inInternational Brain–Computer Interface Workshop;2006.
- 10.1088/1741-2560/7/5/056013 · DOI · Paper page
- 10.1111/j.1469-8986.2008.00783.x · DOI · Paper page
- 10.1007/978-3-642-21852-1_54 · DOI
- 10.1126/science.3749885 · DOI · Paper page
- del R Millàn J., 2009, Asynchronous Non‐Invasive Brain‐Actuated Control of an Intelligent Wheelchair, Conf. Proc. IEEE Eng. Med. Biol. Soc., 2009, 3361
- 10.1109/TSMCB.2011.2181833 · DOI · Paper page
- Tavella M., 2010, Towards Natural Non‐Invasive Hand Neuroprostheses for Daily Living, Conf. Proc. IEEE Eng. Med. Biol. Soc., 2010, 126
- Duvinage M., 2012, Human Walk Modeled by PCPG to Control a Lower Limb Neuroprosthesis by High‐Level Commands, J. Syst. Cybern. Inform., 10, 70
- 10.1177/155005941104200410 · DOI · Paper page
- 10.1001/archneur.61.12.1844 · DOI · Paper page
- 10.1186/1743-0003-7-60 · DOI · Paper page
- 10.1002/ana.23879 · DOI · Paper page
- Mattia D., 2013, Towards Practical Brain–Computer Interfaces, 131
- 10.3389/fneng.2014.00030 · DOI · Paper page
- 10.1016/j.apmr.2014.08.024 · DOI
- 10.1016/j.clinph.2012.04.030 · DOI · Paper page
- 10.1142/S0129065712500372 · DOI
- 10.3109/02699052.2012.698362 · DOI · Paper page
- 10.1016/j.rehab.2013.07.962 · doi:10.1016/j.rehab.2013.07.962
- 10.1016/j.entcom.2009.09.007 · DOI · Paper page
- 10.1109/TCIAIG.2013.2263555 · DOI · Paper page
- Lotte F., 2013, Towards Practical Brain‐Computer Interfaces, 197
- 10.1109/TNSRE.2003.814438 · DOI · Paper page
- 10.1155/ASP.2005.3156 · DOI · Paper page
- 10.1109/TCIAIG.2012.2237517 · DOI
- 10.1155/2012/124728 · DOI
- 10.1109/TNSRE.2007.906956 · DOI · Paper page
- 10.1109/TBME.2007.903709 · DOI · Paper page
- 10.1162/pres.19.1.71 · DOI
- 10.1162/pres.19.1.25 · DOI
- 10.1162/pres.19.1.54 · DOI
- 10.1109/TCIAIG.2013.2252348 · DOI
- 10.1109/TCIAIG.2013.2253778 · DOI
- 10.1088/1741-2560/11/5/056011 · DOI
- L.GeorgeandA.Lécuyer. An Overview of Research on Passive Brain–Computer Interfaces for Implicit Human–Computer Interaction inInternational Conference on Applied Bionics and Biomechanics 2010 Italy.
- Mühl C., 2014, EEG‐Based Workload Estimation Across Affective Contexts, Front. Neurosci., 8, 114
- B.Hamadicharef H. H.Zhang C. T.Guan C. C.Wang K. S.Phua K. P.Tee andK.K. Ang. Learning EEG‐Based Spectral‐Spatial Patterns for Attention Level Measurement. InProceedings of the 2009 IEEE International Symposium on Circuits and Systems (ISCAS2009) 2009 pp1465–1468. · DOI
- 10.1080/2326263X.2014.912881 · DOI · Paper page
- J.Frey C.Mühl F.Lotte andM.Hachet. Review of the Use of Electroencephalography as an Evaluation Method for Human–Computer Interaction. InProc. of the PhyCS 2014.
- 10.1109/MCG.2013.80 · DOI
- Frey J., 2015, Estimating Visual Comfort in Stereoscopic Displays Using Electroencephalography: A Proof‐of‐Concept, Proc. Interact
- D.Wobrock J.Frey D.Graeff J.‐B.de la Rivière J.Castet andF.Lotte. Continuous Mental Effort Evaluation During 3D Object Manipulation Tasks Based on Brain and Physiological Signals. InProc. Interact 2015. · DOI
- Niedermeyer E., 2005, Niedermeyer's Electroencephalography: Basic Principles, Clinical Applications, and Related Fields
- 10.1371/journal.pone.0000637 · DOI · Paper page
- 10.3389/fnins.2011.00053 · DOI · Paper page
- 10.3389/fnins.2012.00060 · DOI · Paper page
- Duvinage M., 2012, A p300‐Based Quantitative Comparison between the Emotiv Epoc Headset and a Medical EEG Device, Biomedical Engineering Online, 765
- 10.1109/MSPEC.2009.4734313 · doi:10.1109/mspec.2009.4734313
- Brunner C., 2013, Towards Practical Brain–Computer Interfaces, 303
- 10.1109/TBME.2004.827072 · DOI · Paper page
- 10.3389/fninf.2011.00030 · DOI · Paper page
- F.Lotte. Brain–Computer Interfaces for 3D Games: Hype or Hope? InFoundations of Digital Games 2011 doi: 10.1145/2159365.2159427. · DOI
- 10.1088/1741-2560/8/2/025002 · DOI · Paper page
- 10.3389/fnhum.2012.00114 · DOI
- 10.1007/978-3-319-07437-5_45 · DOI
- 10.1007/s12152-011-9132-6 · DOI · Paper page
Cited by
A review of classification algorithms for EEG-based brain–computer interfaces: A 10 year update
Lotte, F., Bougrain, L., Cichocki, A., Clerc, M., Congedo, M., Rakotomamonjy, A., & Yger, F. (2018) · Journal of Neural Engineering · doi:10.1088/1741-2552/aab2f2 · Cited by 2,239
Self-citationDeep learning-based electroencephalography analysis: a systematic review
Roy, Y., Banville, H., Albuquerque, I., Gramfort, A., Falk, T. H., & Faubert, J. (2019) · Journal of Neural Engineering · doi:10.1088/1741-2552/ab260c · Cited by 1,532
“State-of-the-art techniques, such as Riemannian geometry-based classifiers and adaptive classifiers [116], can handle these problems with varying levels of success.”
BackgroundMethodInfluentialBrain computer interface: control signals review
Ramadan, R. A., & Vasilakos, A. V. (2017) · Neurocomputing · doi:10.1016/j.neucom.2016.10.024 · Cited by 551
Rashid, M., Sulaiman, N., P. P. Abdul Majeed, A., Musa, R. M., Ab. Nasir, A. F., Bari, B. S., & Khatun, S. (2020) · Frontiers in Neurorobotics · doi:10.3389/fnbot.2020.00025 · Cited by 506
Riemannian Approaches in Brain-Computer Interfaces: A Review
Yger, F., Berar, M., & Lotte, F. (2017) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2016.2627016 · Cited by 420
Self-citation
Metadata
- Authors
- Lotte, F., Bougrain, L., & Clerc, M.
- Venue
- Wiley Encyclopedia of Electrical and Electronics Engineering
- Publisher
- Wiley
- Published
- 2015-09-15
- Pages
- 1-20
- OpenAlex
- W1936852542
- Cited by
- 98
- References
- 34
- Type
- reference entry
- Language
- en
- Open access
- closed
- Licence
- doi.wiley.com/10.1002/tdm_license_1.1 (tdm)
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.