The DOI matches its Crossref record; 23 of the 23 references it cites were found in a registry or an index.
Triboelectric Nanogenerators for Therapeutic Electrical Stimulation
Open accessAbstract
Current solutions developed for the purpose of in and on body (IOB) electrical stimulation (ES) lack autonomous qualities necessary for comfortable, practical, and self‐dependent use. Consequently, recent focus has been placed on developing self‐powered IOB therapeutic devices capable of generating therapeutic ES for human use. With the recent invention of the triboelectric nanogenerator (TENG), harnessing passive human biomechanical energy to develop self‐powered systems has allowed for the introduction of novel therapeutic ES solutions. TENGs are especially effective at providing ES for IOB therapeutic systems given their bioconformability, low cost, simple manufacturability, and self‐powering capabilities. Due to the key role of naturally induced electrical signals in many physiological functions, TENG‐induced ES holds promise to provide a novel paradigm in therapeutic interventions. The aim here is to detail research on IOB TENG devices applied for ES‐based therapy in the fields of regenerative medicine, neurology, rehabilitation, and pharmaceutical engineering. Furthermore, considering TENG‐produced ES can be measured for sensing applications, this technology is paving the way to provide a fully autonomous personalized healthcare system, capable of IOB energy generation, sensing, and therapeutic intervention. Considering these grounds, it seems highly relevant to review TENG‐ES research and applications, as they could constitute the foundation and future of personalized healthcare.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Wearable biosensors for healthcare monitoring
Kim, J., Campbell, A. S., de Ávila, B. E.-F., & Wang, J. (2019) · Nature Biotechnology · doi:10.1038/s41587-019-0045-y · Cited by 3,373
Osteoporosis: now and the future
Rachner, T. D., Khosla, S., & Hofbauer, L. C. (2011) · The Lancet · doi:10.1016/s0140-6736(10)62349-5 · Cited by 2,696
Wearable Electronics and Smart Textiles: A Critical Review
Stoppa, M., & Chiolerio, A. (2014) · Sensors · doi:10.3390/s140711957 · Cited by 2,107
The rise of plastic bioelectronics
Someya, T., Bao, Z., & Malliaras, G. G. (2016) · Nature · doi:10.1038/nature21004 · Cited by 1,884
Li, S., Wang, Y., Xue, J., Zhao, N., & Zhu, T. (2020) · International Journal of Environmental Research and Public Health · doi:10.3390/ijerph17062032 · Cited by 1,835
Wang, Z. L. (2014) · Faraday Discuss. · doi:10.1039/c4fd00159a · Cited by 1,749
Monitoring of Vital Signs with Flexible and Wearable Medical Devices
Khan, Y., Ostfeld, A. E., Lochner, C. M., Pierre, A., & Arias, A. C. (2016) · Advanced Materials · doi:10.1002/adma.201504366 · Cited by 1,408
Non-invasive wearable electrochemical sensors: a review
Bandodkar, A. J., & Wang, J. (2014) · Trends in Biotechnology · doi:10.1016/j.tibtech.2014.04.005 · Cited by 1,247
Choi, S., Han, S. I., Jung, D., Hwang, H. J., Lim, C., Bae, S., Park, O. K., Tschabrunn, C. M., Lee, M., Bae, S. Y., et al. (2018) · Nature Nanotechnology · doi:10.1038/s41565-018-0226-8 · Cited by 984
Navarro, X., Krueger, T. B., Lago, N., Micera, S., Stieglitz, T., & Dario, P. (2005) · Journal of the Peripheral Nervous System · doi:10.1111/j.1085-9489.2005.10303.x · Cited by 845
Menke, N. B., Ward, K. R., Witten, T. M., Bonchev, D. G., & Diegelmann, R. F. (2007) · Clinics in Dermatology · doi:10.1016/j.clindermatol.2006.12.005 · Cited by 792
Hwang, G., Park, H., Lee, J., Oh, S., Park, K., Byun, M., Park, H., Ahn, G., Jeong, C. K., No, K., et al. (2014) · Advanced Materials · doi:10.1002/adma.201400562 · Cited by 672
Biodegradable triboelectric nanogenerator as a life-time designed implantable power source
Zheng, Q., Zou, Y., Zhang, Y., Liu, Z., Shi, B., Wang, X., Jin, Y., Ouyang, H., Li, Z., & Wang, Z. L. (2016) · Science Advances · doi:10.1126/sciadv.1501478 · Cited by 617
Xie, Y., Wang, S., Niu, S., Lin, L., Jing, Q., Yang, J., Wu, Z., & Wang, Z. L. (2014) · Advanced Materials · doi:10.1002/adma.201402428 · Cited by 554
Modelling bone tissue fracture and healing: a review
Doblaré, M., Garcı́a, J. M., & Gómez, M. J. (2004) · Engineering Fracture Mechanics · doi:10.1016/j.engfracmech.2003.08.003 · Cited by 504
Fully Bioabsorbable Natural‐Materials‐Based Triboelectric Nanogenerators
Jiang, W., Li, H., Liu, Z., Li, Z., Tian, J., Shi, B., Zou, Y., Ouyang, H., Zhao, C., Zhao, L., et al. (2018) · Advanced Materials · doi:10.1002/adma.201801895 · Cited by 449
Han, L., Yan, L., Wang, M., Wang, K., Fang, L., Zhou, J., Fang, J., Ren, F., & Lu, X. (2018) · Chemistry of Materials · doi:10.1021/acs.chemmater.8b01446 · Cited by 438
Effective Wound Healing Enabled by Discrete Alternative Electric Fields from Wearable Nanogenerators
Long, Y., Wei, H., Li, J., Yao, G., Yu, B., Ni, D., Gibson, A. L., Lan, X., Jiang, Y., Cai, W., et al. (2018) · ACS Nano · doi:10.1021/acsnano.8b07038 · Cited by 397
The vagus nerve in appetite regulation, mood, and intestinal inflammation
Browning, K. N., Verheijden, S., & Boeckxstaens, G. E. (2017) · Gastroenterology · doi:10.1053/j.gastro.2016.10.046 · Cited by 361
A flexible and wearable glucose sensor based on functional polymers with Soft-MEMS techniques
Kudo, H., Sawada, T., Kazawa, E., Yoshida, H., Iwasaki, Y., & Mitsubayashi, K. (2006) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2006.05.006 · Cited by 255
A mm-Sized Wireless Implantable Device for Electrical Stimulation of Peripheral Nerves
Charthad, J., Chang, T. C., Liu, Z., Sawaby, A., Weber, M. J., Baker, S., Gore, F., Felt, S. A., & Arbabian, A. (2018) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2018.2799623 · Cited by 230
Maffiuletti, N. A., Roig, M., Karatzanos, E., & Nanas, S. (2013) · BMC Medicine · doi:10.1186/1741-7015-11-137 · Cited by 199
Wang, J., Thow, X. Y., Wang, H., Lee, S., Voges, K., Thakor, N. V., Yen, S., & Lee, C. (2018) · Advanced Healthcare Materials · doi:10.1002/adhm.201700987 · Cited by 43
Cited by
Electronic Textiles for Wearable Point-of-Care Systems
Chen, G., Xiao, X., Zhao, X., Tat, T., Bick, M., & Chen, J. (2022) · Chemical Reviews · doi:10.1021/acs.chemrev.1c00502 · Cited by 688
Self-citationSelf‐Powered Respiration Monitoring Enabled By a Triboelectric Nanogenerator
Su, Y., Chen, G., Chen, C., Gong, Q., Xie, G., Yao, M., Tai, H., Jiang, Y., & Chen, J. (2021) · Advanced Materials · doi:10.1002/adma.202101262 · Cited by 481
Self-citationLeveraging triboelectric nanogenerators for bioengineering
Zhang, S., Bick, M., Xiao, X., Chen, G., Nashalian, A., & Chen, J. (2021) · Matter · doi:10.1016/j.matt.2021.01.006 · Cited by 288
Self-citationWearable Biosensors for Non-Invasive Sweat Diagnostics
Xu, J., Fang, Y., & Chen, J. (2021) · Biosensors · doi:10.3390/bios11080245 · Cited by 208
Self-citationWang, T., Ouyang, H., Luo, Y., Xue, J., Wang, E., Zhang, L., Zhou, Z., Liu, Z., Li, X., Tan, S., et al. (2024) · Science Advances · doi:10.1126/sciadv.adi6799 · Cited by 161
Metadata
- Authors
- Conta, G., Libanori, A., Tat, T., Chen, G., & Chen, J.
- Venue
- Advanced Materials
- Publisher
- Wiley
- Published
- 2021-05-20
- Volume
- 33
- Issue
- 26
- Pages
- e2007502-e2007502
- ISSN
- 0935-9648 (ISSN-L)
- 1521-4095
- OpenAlex
- W3161343970
- Cited by
- 205
- References
- 23
- FWCI
- 10.92
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.