Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 412

The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.

Fluorescence Imaging In Vivo at Wavelengths beyond 1500 nm

Open access
Diao, Shuo, Blackburn, Jeffrey L., Hong, Guosong, Antaris, Alexander L., Chang, Junlei, Wu, Justin Z., Zhang, Bo, Cheng, Kai, Kuo, Calvin J., Dai, Hongjie·2015·Angewandte Chemie International Edition

Abstract

Compared to imaging in the visible and near‐infrared regions below 900 nm, imaging in the second near‐infrared window (NIR‐II, 1000–1700 nm) is a promising method for deep‐tissue high‐resolution optical imaging in vivo mainly owing to the reduced scattering of photons traversing through biological tissues. Herein, semiconducting single‐walled carbon nanotubes with large diameters were used for in vivo fluorescence imaging in the long‐wavelength NIR region (1500–1700 nm, NIR‐IIb). With this imaging agent, 3–4 μm wide capillary blood vessels at a depth of about 3 mm could be resolved. Meanwhile, the blood‐flow speeds in multiple individual vessels could be mapped simultaneously. Furthermore, NIR‐IIb tumor imaging of a live mouse was explored. NIR‐IIb imaging can be generalized to a wide range of fluorophores emitting at up to 1700 nm for high‐performance in vivo optical imaging.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/anie.201507473

Cites

5 of 5 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 5 references

Research works printed but not linked: 21

  1. 10.1016/j.cbpa.2003.08.007 · DOI · Paper page
  2. 10.1016/j.cbpa.2009.09.029 · DOI · Paper page
  3. 10.1007/s12274-012-0218-1 · doi:10.1007/s12274-012-0218-1
  4. 10.1007/s12274-012-0235-0 · doi:10.1007/s12274-012-0235-0
  5. 10.1021/ja307966u · DOI · Paper page
  6. 10.1038/nphoton.2014.166 · DOI · Paper page
  7. 10.1038/nm.2995 · DOI · Paper page
  8. 10.1038/ncomms3199 · DOI · Paper page
  9. 10.1021/nl2031663 · DOI · Paper page
  10. 10.1021/ja303737a · DOI · Paper page
  11. 10.1161/CIRCIMAGING.113.000305 · DOI
  12. 10.1016/0009-2614(95)00825-O · DOI · Paper page
  13. 10.1126/science.1078727 · DOI · Paper page
  14. 10.1126/science.1072631 · DOI · Paper page
  15. 10.1088/0022-3727/38/15/004 · DOI · Paper page
  16. 10.1021/nn305336x · DOI · Paper page
  17. 10.1007/s12274-011-0152-7 · DOI
  18. 10.1158/0008-5472.CAN-06-3944 · DOI
  19. 10.1109/TBME.2002.1028423 · DOI · Paper page
  20. 10.1038/nphoton.2007.146 · DOI · Paper page
  21. 10.1073/pnas.0707654105 · DOI · Paper page

Cited by

See all 412

Metadata

Authors
Diao, S., Blackburn, J. L., Hong, G., Antaris, A. L., Chang, J., Wu, J. Z., Zhang, B., Cheng, K., Kuo, C. J., & Dai, H.
Venue
Angewandte Chemie International Edition
Publisher
Wiley
Published
2015-10-13
Volume
54
Issue
49
Pages
14758-14762
ISSN
  • 1433-7851 (ISSN-L)
  • 1521-3773
OpenAlex
W2163040806
Cited by
412
References
5
FWCI
19.21
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Fluorescence Imaging In Vivo at Wavelengths beyond 1500 nm. https://app.cochat.ai/papers/10.1002/anie.201507473
The paper
Diao, S., Blackburn, J. L., Hong, G., Antaris, A. L., Chang, J., Wu, J. Z., Zhang, B., Cheng, K., Kuo, C. J., & Dai, H. (2015). Fluorescence Imaging In Vivo at Wavelengths beyond 1500 nm. Angewandte Chemie International Edition. https://doi.org/10.1002/anie.201507473

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.