The DOI matches its Crossref record; 32 of the 32 references it cites were found in a registry or an index.
Diffusion-weighted magnetic resonance imaging for the assessment of fibrosis in chronic hepatitis C
Abstract
Liver biopsy is the gold standard for assessing fibrosis but has several limitations. We evaluated a noninvasive method, so-called diffusion-weighted magnetic resonance imaging (DWMRI), which measures the apparent diffusion coefficient (ADC) of water, for the diagnosis of liver fibrosis in patients with chronic hepatitis C virus (HCV). We analyzed 20 healthy volunteers and 54 patients with chronic HCV (METAVIR: F0, n = 1; F1, n = 30; F2, n = 8; F3, n = 5; and F4, n = 10) prospectively included. Patients with moderate-to-severe fibrosis (F2-F3-F4) had hepatic ADC values lower than those without or with mild fibrosis (F0-F1; mean: 1.10 ± 0.11 versus 1.30 ± 0.12 × 10−3 mm2/s) and healthy volunteers (mean: 1.44 ± 0.02 × 10−3 mm2/s). In discriminating patients staged F3-F4, the areas under the receiving operating characteristic curves (AUCs) were 0.92 (±0.04) for magnetic resonance imaging (MRI), 0.92 (±0.05) for elastography, 0.79 (±0.08) for FibroTest, 0.87 (±0.06) for the aspartate aminotransferase to platelets ratio index (APRI), 0.86 (±0.06) for the Forns index, and 0.87 (±0.06) for hyaluronate. In these patients, the sensitivity, specificity, positive predictive value, and negative predictive value were 87%, 87%, 72%, and 94%, respectively, with an ADC cutoff level of 1.21 × 10−3 mm2/s. In discriminating patients staged F2-F3-F4, the AUC values were 0.79 (±0.07) for MRI, 0.87 (±0.05) for elastography, 0.68 (±0.09) for FibroTest, 0.81 (±0.06) for APRI, 0.72 (±0.08) for the Forns index, and 0.77 (±0.06) for hyaluronate. Conclusion: This preliminary study suggests that DWMRI compares favorably with other noninvasive tests for the presence of significant liver fibrosis. (Hepatology 2007.)
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The meaning and use of the area under a receiver operating characteristic (ROC) curve.
Hanley, J. A., & McNeil, B. J. (1982) · Radiology · doi:10.1148/radiology.143.1.7063747 · Cited by 21,856
Nonparametric Statistical Methods
(1999) · Technometrics · doi:10.1080/00401706.1999.10485954 · Cited by 6,090
Wai, C.-T., Greenson, J. K., Fontana, R. J., Kalbfleisch, J. D., Marrero, J. A., Conjeevaram, H. S., & Lok, A. S.-F. (2003) · Hepatology · doi:10.1053/jhep.2003.50346 · Cited by 4,406
Nonparametric Statistical Methods.
Knott, M., Hollander, M., & Wolfe, D. A. (1974) · Journal of the Royal Statistical Society. Series A (General) · doi:10.2307/2344557 · Cited by 2,662
Castéra, L., Vergniol, J., Foucher, J., Le Bail, B., Chanteloup, E., Haaser, M., Darriet, M., Couzigou, P., & de Lédinghen, V. (2005) · Gastroenterology · doi:10.1053/j.gastro.2004.11.018 · Cited by 2,487
Sampling Variability of Liver Fibrosis in Chronic Hepatitis C
Bedossa, P., Dargère, D., & Paradis, V. (2003) · Hepatology · doi:10.1016/j.hep.2003.09.022 · Cited by 2,376
Ziol, M., Handra-Luca, A., Kettaneh, A., Christidis, C., Mal, F., Kazemi, F., de Lédinghen, V., Marcellin, P., Dhumeaux, D., Trinchet, J.-C., et al. (2005) · Hepatology · doi:10.1002/hep.20506 · Cited by 1,470
Imbert-Bismut, F., Ratziu, V., Pieroni, L., Charlotte, F., Benhamou, Y., & Poynard, T. (2001) · The Lancet · doi:10.1016/s0140-6736(00)04258-6 · Cited by 1,433
Identification of chronic hepatitis C patients without hepatic fibrosis by a simple predictive model
Forns, X. (2002) · Hepatology · doi:10.1016/s0270-9139(02)00107-6 · Cited by 1,125
Practices of Liver Biopsy in France: Results of a Prospective Nationwide Survey
Cadranel, J.-F., Rufat, P., & Degos, F. (2000) · Hepatology · doi:10.1053/jhep.2000.16602 · Cited by 993
Nonparametric Statistical Methods, 2nd, Ed.
Borror, C. M. (2001) · Journal of Quality Technology · doi:10.1080/00224065.2001.11980073 · Cited by 874
Taouli, B., Vilgrain, V., Dumont, E., Daire, J.-L., Fan, B., & Menu, Y. (2003) · Radiology · doi:10.1148/radiol.2261011904 · Cited by 577
Hepascore: An Accurate Validated Predictor of Liver Fibrosis in Chronic Hepatitis C Infection
Adams, L. A., Bulsara, M., Rossi, E., DeBoer, B., Speers, D., George, J., Kench, J., Farrell, G., McCaughan, G. W., & Jeffrey, G. P. (2005) · Clinical Chemistry · doi:10.1373/clinchem.2005.048389 · Cited by 539
Marcellin, P., Ziol, M., Bedossa, P., Douvin, C., Poupon, R., De Lédinghen, V., & Beaugrand, M. (2009) · Liver International · doi:10.1111/j.1478-3231.2008.01802.x · Cited by 535
Self-citationYamada, I., Aung, W., Himeno, Y., Nakagawa, T., & Shibuya, H. (1999) · Radiology · doi:10.1148/radiology.210.3.r99fe17617 · Cited by 519
MR Elastography of the Liver: Preliminary Results
Rouvière, O., Yin, M., Dresner, M. A., Rossman, P. J., Burgart, L. J., Fidler, J. L., & Ehman, R. L. (2006) · Radiology · doi:10.1148/radiol.2402050606 · Cited by 447
Liver fibrosis: non‐invasive assessment with MR elastography
Huwart, L., Peeters, F., Sinkus, R., Annet, L., Salameh, N., ter Beek, L. C., Horsmans, Y., & Van Beers, B. E. (2006) · NMR in Biomedicine · doi:10.1002/nbm.1030 · Cited by 417
Diffusion-weighted single-shot echoplanar MR imaging for liver disease.
Kim, T., Murakami, T., Takahashi, S., Hori, M., Tsuda, K., & Nakamura, H. (1999) · American Journal of Roentgenology · doi:10.2214/ajr.173.2.10430143 · Cited by 349
Patel, K., Gordon, S. C., Jacobson, I., Hézode, C., Oh, E., Smith, K. M., Pawlotsky, J.-M., & McHutchison, J. G. (2004) · Journal of Hepatology · doi:10.1016/j.jhep.2004.08.008 · Cited by 330
Ichikawa, T., Haradome, H., Hachiya, J., Nitatori, T., & Araki, T. (1998) · American Journal of Roentgenology · doi:10.2214/ajr.170.2.9456953 · Cited by 314
Annet, L., Materne, R., Danse, E., Jamart, J., Horsmans, Y., & Van Beers, B. E. (2003) · Radiology · doi:10.1148/radiol.2292021128 · Cited by 295
Abdominal diffusion mapping with use of a whole-body echo-planar system.
Müller, M. F., Prasad, P., Siewert, B., Nissenbaum, M. A., Raptopoulos, V, & Edelman, R. R. (1994) · Radiology · doi:10.1148/radiology.190.2.8284402 · Cited by 245
Guéchot, J., Laudat, A., Loria, A., Serfaty, L., Poupon, R., & Giboudeau, J. (1996) · Clinical Chemistry · doi:10.1093/clinchem/42.4.558 · Cited by 239
Self-citationPerformance of serum marker panels for liver fibrosis in chronic hepatitis C
Parkes, J., Guha, I. N., Roderick, P., & Rosenberg, W. (2006) · Journal of Hepatology · doi:10.1016/j.jhep.2005.10.019 · Cited by 239
Assessment of hepatic perfusion parameters with dynamic MRI
Materne, R., Smith, A. M., Peeters, F., Dehoux, J. P., Keyeux, A., Horsmans, Y., & Van Beers, B. E. (2002) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10045 · Cited by 226
Koinuma, M., Ohashi, I., Hanafusa, K., & Shibuya, H. (2005) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.20344 · Cited by 218
Cirrhosis: Modified Caudate–Right Lobe Ratio
Awaya, H., Mitchell, D. G., Kamishima, T., Holland, G., Ito, K., & Matsumoto, T. (2002) · Radiology · doi:10.1148/radiol.2243011495 · Cited by 196
Liver Fibrosis: Noninvasive Diagnosis with Double Contrast Material–enhanced MR Imaging
Aguirre, D. A., Behling, C. A., Alpert, E., Hassanein, T. I., & Sirlin, C. B. (2006) · Radiology · doi:10.1148/radiol.2392050505 · Cited by 193
Diffusion-weighted Imaging of the Liver: Technical Challenges and Prospects for the Future
Naganawa, S., Kawai, H., Fukatsu, H., Sakurai, Y., Aoki, I., Miura, S., Mimura, T., Kanazawa, H., & Ishigaki, T. (2005) · Magnetic Resonance in Medical Sciences · doi:10.2463/mrms.4.175 · Cited by 147
Taouli, B. A., Martin, A. J., Qayyum, A., Merriman, R. B., Vigneron, D. B., Yeh, B. M., & Coakley, F. V. (2004) · American Journal of Roentgenology · doi:10.2214/ajr.183.3.1830677 · Cited by 134
Diagnostic et quantification de la fibrose hépatique par IRM de diffusion : résultats préliminaires
Aubé, C., Racineux, P. X., Lebigot, J., Oberti, F., Croquet, V., Argaud, C., Calès, P., & Caron, C. (2004) · Journal de Radiologie · doi:10.1016/s0221-0363(04)97582-8 · Cited by 109
Cho, S. G., Kim, M. Y., Kim, H. J., Kim, Y. S., Choi, W. S., Shin, S. H., Hong, K. C., Kim, Y., Lee, J. H., & Suh, C. H. (2001) · Radiology · doi:10.1148/radiol.2213010106 · Cited by 90
Cited by
Non-invasive evaluation of liver fibrosis using transient elastography
Castera, L., Forns, X., & Alberti, A. (2008) · Journal of Hepatology · doi:10.1016/j.jhep.2008.02.008 · Cited by 1,430
Diffusion-weighted MR Imaging of the Liver
Taouli, B., & Koh, D.-M. (2010) · Radiology · doi:10.1148/radiol.09090021 · Cited by 810
Schwenzer, N. F., Springer, F., Schraml, C., Stefan, N., Machann, J., & Schick, F. (2009) · Journal of Hepatology · doi:10.1016/j.jhep.2009.05.023 · Cited by 749
Tsochatzis, E. A., Gurusamy, K. S., Ntaoula, S., Cholongitas, E., Davidson, B. R., & Burroughs, A. K. (2011) · Journal of Hepatology · doi:10.1016/j.jhep.2010.07.033 · Cited by 709
Liver Cirrhosis: Intravoxel Incoherent Motion MR Imaging—Pilot Study
Luciani, A., Vignaud, A., Cavet, M., Tran Van Nhieu, J., Mallat, A., Ruel, L., Laurent, A., Deux, J.-F., Brugieres, P., & Rahmouni, A. (2008) · Radiology · doi:10.1148/radiol.2493080080 · Cited by 612
Metadata
- Authors
- Lewin, M., Poujol-Robert, A., Boëlle, P.-Y., Wendum, D., Lasnier, E., Viallon, M., Guéchot, J., Hoeffel, C., Arrivé, L., Tubiana, J.-M., & Poupon, R.
- Venue
- Hepatology
- Published
- 2007-09
- Volume
- 46
- Issue
- 3
- Pages
- 658-665
- ISSN
- 0270-9139 (ISSN-L)
- OpenAlex
- W2084690382
- Cited by
- 265
- References
- 32
- FWCI
- 10.68
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.