The DOI matches its Crossref record; 65 of the 65 references it cites were found in a registry or an index.
Practical implications of some recent studies in electrospray ionization fundamentals
Abstract
I. Introduction 363 II. The Mechanics of ESI‐MS 363 III. Analyte Characteristics and Selectivity 365 A. Charging the Analyte 366 1. Ionization Through Charge Separation 366 2. Adduct Formation 366 3. Ionization Through Gas‐Phase Reactions 366 4. Ionization Through Electrochemical Oxidation or Reduction 368 B. Analyte Surface Activity and Its Effect on ESI Response 368 1. Surface Activity and the Fissioning Process 369 2. Predicting ESI Response from Other Parameters 369 C. The Role of Analyte p K a and Solvent pH 370 D. Improving ESI Response Through Derivatization 371 IV. The Working Curve and Dynamic Range 373 A. Detection Limits With ESI 373 1. Background Interferences 373 2. Random Noise 374 3. Ion Transmission and Sensitivity 374 B. Sources of Signal Saturation at High Concentrations 375 1. Limited Amount of Excess Charge 375 2. Limited Space on Droplet Surfaces 375 3. Suppression and Competition at High Concentrations 376 C. Improving the Detection Limit and Linear Dynamic Range 376 1. Extending to Higher Concentrations 376 2. Extending to Lower Concentrations 376 V. Instrumental Parameters and Stability 377 A. Current–Voltage Curves 377 B. Effect of Instrumental Parameters on the Current–Voltage Curve 378 C. Self‐Stabilizing Operation 379 D. Non‐Conductive vs. Conductive Spray Capillaries 379 VI. Solution Characteristics 380 A. The Ideal ESI Solvent 380 B. Solvent Choice for Analysis in the Positive Ion Mode 381 C. Solvent Choice for Analysis in the Negative Ion Mode 381 D. Compatibility Between ESI and Liquid Separation Techniques 382 VII. Summary 382 VIII. Acknowledgment 383 References 383 In accomplishing successful electrospray ionization analyses, it is imperative to have an understanding of the effects of variables such as analyte structure, instrumental parameters, and solution composition. Here, we review some fundamental studies of the ESI process that are relevant to these issues. We discuss how analyte chargeability and surface activity are related to ESI response, and how accessible parameters such as nonpolar surface area and reversed phase HPLC retention time can be used to predict relative ESI response. Also presented is a description of how derivitizing agents can be used to maximize or enable ESI response by improving the chargeability or hydrophobicity of ESI analytes. Limiting factors in the ESI calibration curve are discussed. At high concentrations, these factors include droplet surface area and excess charge concentration, whereas at low concentrations ion transmission becomes an issue, and chemical interference can also be limiting. Stable and reproducible non‐pneumatic ESI operation depends on the ability to balance a number of parameters, including applied voltage and solution surface tension, flow rate, and conductivity. We discuss how changing these parameters can shift the mode of ESI operation from stable to unstable, and how current–voltage curves can be used to characterize the mode of ESI operation. Finally, the characteristics of the ideal ESI solvent, including surface tension and conductivity requirements, are discussed. Analysis in the positive ion mode can be accomplished with acidified methanol/water solutions, but negative ion mode analysis necessitates special constituents that suppress corona discharge and facilitate the production of stable negative ions. © 2002 Wiley Periodicals, Inc., Mass Spec Rev 20: 362–387, 2001; Published online in Wiley InterScience (www.interscience.wiley.com). DOI 10.1002/mas.10008
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Electrospray Ionization for Mass Spectrometry of Large Biomolecules
Fenn, J. B., Mann, M., Meng, C. K., Wong, S. F., & Whitehouse, C. M. (1989) · Science · doi:10.1126/science.2675315 · Cited by 7,634
Analytical Properties of the Nanoelectrospray Ion Source
Wilm, M., & Mann, M. (1996) · Analytical Chemistry · doi:10.1021/ac9509519 · Cited by 1,868
Dole, M., Mack, L. L., Hines, R. L., Mobley, R. C., Ferguson, L. D., & Alice, M. B. (1968) · The Journal of Chemical Physics · doi:10.1063/1.1670391 · Cited by 1,613
On the evaporation of small ions from charged droplets
Iribarne, J. V., & Thomson, B. A. (1976) · The Journal of Chemical Physics · doi:10.1063/1.432536 · Cited by 1,281
Bonfiglio, R., King, R. C., Olah, T. V., & Merkle, K. (1999) · Rapid Communications in Mass Spectrometry · doi:10.1002/(sici)1097-0231(19990630)13:12<1175::aid-rcm639>3.0.co;2-0 · Cited by 939
The current emitted by highly conducting Taylor cones
De La Mora, J. F., & Loscertales, I. G. (1994) · Journal of Fluid Mechanics · doi:10.1017/s0022112094003472 · Cited by 884
Bruins, A. P., Covey, T. R., & Henion, J. D. (1987) · Analytical Chemistry · doi:10.1021/ac00149a003 · Cited by 879
From ions in solution to ions in the gas phase - the mechanism of electrospray mass spectrometry
Kebarle, P., & Tang, L. (1993) · Analytical Chemistry · doi:10.1021/ac00070a001 · Cited by 781
Charge and fission of droplets in electrostatic sprays
Gomez, A., & Tang, K. (1994) · Physics of Fluids · doi:10.1063/1.868037 · Cited by 654
Electrostatic spraying of liquids in cone-jet mode
Cloupeau, M., & Prunet-Foch, B. (1989) · Journal of Electrostatics · doi:10.1016/0304-3886(89)90081-8 · Cited by 616
[21] Electrospray ionization mass spectrometry
Fred Banks, J., & Whitehouse, C. M. (1996) · Methods in Enzymology · doi:10.1016/s0076-6879(96)70023-x · Cited by 522
Ion formation from charged droplets: Roles of geometry, energy, and time
Fenn, J. B. (1993) · Journal of the American Society for Mass Spectrometry · doi:10.1016/1044-0305(93)85014-o · Cited by 518
Micro-electrospray mass spectrometry: Ultra-high-sensitivity analysis of peptides and proteins
Emmett, M. R., & Caprioli, R. M. (1994) · Journal of the American Society for Mass Spectrometry · doi:10.1016/1044-0305(94)85001-1 · Cited by 510
Tang, L., & Kebarle, P. (1993) · Analytical Chemistry · doi:10.1021/ac00072a020 · Cited by 506
Enke, C. G. (1997) · Analytical Chemistry · doi:10.1021/ac970095w · Cited by 419
Self-citationAnalysis of Oligonucleotides by HPLC−Electrospray Ionization Mass Spectrometry
Apffel, A., Chakel, J. A., Fischer, S., Lichtenwalter, K., & Hancock, W. S. (1997) · Analytical Chemistry · doi:10.1021/ac960916h · Cited by 398
On the mechanisms by which the charged droplets produced by electrospray lead to gas phase ions
Kebarle, P., & Peschke, M. (2000) · Analytica Chimica Acta · doi:10.1016/s0003-2670(99)00598-x · Cited by 352
Apffel, A., Fischer, S., Goldberg, G., Goodley, P. C., & Kuhlmann, F. E. (1995) · Journal of Chromatography A · doi:10.1016/0021-9673(95)00175-m · Cited by 344
Relating Electrospray Ionization Response to Nonpolar Character of Small Peptides
Cech, N. B., & Enke, C. G. (2000) · Analytical Chemistry · doi:10.1021/ac9914869 · Cited by 342
Self-citationNano-electrospray ionization mass spectrometry: addressing analytical problems beyond routine
Karas, M., Bahr, U., & Dülcks, T. (2000) · Fresenius' Journal of Analytical Chemistry · doi:10.1007/s002160051561 · Cited by 275
Electrified droplet fission and the Rayleigh limit
Taflin, D. C., Ward, T. L., & Davis, E. J. (1989) · Langmuir · doi:10.1021/la00086a016 · Cited by 266
Tang, L., & Kebarle, P. (1991) · Analytical Chemistry · doi:10.1021/ac00023a009 · Cited by 260
Van Berkel, G. J., Zhou, F., & Aronson, J. T. (1997) · International Journal of Mass Spectrometry and Ion Processes · doi:10.1016/s0168-1176(96)04476-x · Cited by 201
Design and Implementation of a New Electrodynamic Ion Funnel
Kim, T., Tolmachev, A. V., Harkewicz, R., Prior, D. C., Anderson, G., Udseth, H. R., Smith, R. D., Bailey, T. H., Rakov, S., & Futrell, J. H. (2000) · Analytical Chemistry · doi:10.1021/ac991412x · Cited by 201
Characterization of an Electrospray Ion Source as a Controlled-Current Electrolytic Cell
Van Berkel, G. J., & Zhou, F. (1995) · Analytical Chemistry · doi:10.1021/ac00113a028 · Cited by 197
Electrospray‐ionization mass spectrometry of intact intrinsic membrane proteins
Whitelegge, J. P., Gundersen, C. B., & Faull, K. F. (1998) · Protein Science · doi:10.1002/pro.5560070619 · Cited by 196
Amad, M. H., Cech, N. B., Jackson, G. S., & Enke, C. G. (2000) · Journal of Mass Spectrometry · doi:10.1002/1096-9888(200007)35:7<784::aid-jms17>3.0.co;2-q · Cited by 191
Self-citationAndrew Karplus, P. (1997) · Protein Science · doi:10.1002/pro.5560060618 · Cited by 184
Quirke, J. M. E., Adams, C. L., & Van Berkel, G. J. (1994) · Analytical Chemistry · doi:10.1021/ac00080a016 · Cited by 176
Pulsation phenomena during electrospray ionization
Juraschek, R., & Röllgen, F. W. (1998) · International Journal of Mass Spectrometry · doi:10.1016/s1387-3806(98)14025-3 · Cited by 174
Kuhlmann, F. E., Apffel, A., Fischer, S. M., Goldberg, G., & Goodley, P. C. (1995) · Journal of the American Society for Mass Spectrometry · doi:10.1016/1044-0305(95)00571-4 · Cited by 174
Van Berkel, G. J., Quirke, J. M. E., Tigani, R. A., Dilley, A. S., & Covey, T. R. (1998) · Analytical Chemistry · doi:10.1021/ac971348o · Cited by 170
Zhu, J., & Cole, R. B. (2000) · Journal of the American Society for Mass Spectrometry · doi:10.1016/s1044-0305(00)00164-1 · Cited by 168
Belov, M. E., Gorshkov, M. V., Udseth, H. R., Anderson, G. A., & Smith, R. D. (2000) · Analytical Chemistry · doi:10.1021/ac991360b · Cited by 164
Biomedical and biochemical applications of liquid chromatography-mass spectrometry
Gelpí, E. (1995) · Journal of Chromatography A · doi:10.1016/0021-9673(94)01287-o · Cited by 159
FROM IONS IN SOLUTION TO IONS IN THE GAS PHASE
Kebarle, P., & Tang, L. (1993) · Analytical Chemistry · doi:10.1021/ac00070a715 · Cited by 158
Bahr, U., Pfenninger, A., Karas, M., & Stahl, B. (1997) · Analytical Chemistry · doi:10.1021/ac970624w · Cited by 157
Ion/Ion Proton Transfer Reactions for Protein Mixture Analysis
Stephenson, J. L., & McLuckey, S. A. (1996) · Analytical Chemistry · doi:10.1021/ac9605657 · Cited by 145
Protonation in electrospray mass spectrometry: Wrong-way-round or right-way-round?
Zhou, S., & Cook, K. D. (2000) · Journal of the American Society for Mass Spectrometry · doi:10.1016/s1044-0305(00)00174-4 · Cited by 140
Predicting Electrospray Response from Chromatographic Retention Time
Cech, N. B., Krone, J. R., & Enke, C. G. (2000) · Analytical Chemistry · doi:10.1021/ac0006019 · Cited by 139
Self-citationNegative ion formation in electrospray mass spectrometry
Straub, R. F., & Voyksner, R. D. (1993) · Journal of the American Society for Mass Spectrometry · doi:10.1016/1044-0305(93)85019-t · Cited by 137
Atmospheric pressure ion evaporation-mass spectrometry
Iribarne, J. V., Dziedzic, P. J., & Thomson, B. A. (1983) · International Journal of Mass Spectrometry and Ion Physics · doi:10.1016/0020-7381(83)87009-0 · Cited by 136
Lu, W., Poon, G. K., Carmichael, P. L., & Cole, R. B. (1996) · Analytical Chemistry · doi:10.1021/ac950786x · Cited by 133
Zhou, S., & Cook, K. D. (2001) · Journal of the American Society for Mass Spectrometry · doi:10.1016/s1044-0305(00)00213-0 · Cited by 125
Cole, R. B., & Harrata, A. K. (1993) · Journal of the American Society for Mass Spectrometry · doi:10.1016/1044-0305(93)85016-q · Cited by 118
Multiply charged negative ions by electrospray ionization of polypeptides and proteins
Loo, J. A., Loo, R. R. O., Light, K. J., Edmonds, C. G., & Smith, R. D. (1992) · Analytical Chemistry · doi:10.1021/ac00025a015 · Cited by 112
Steen, R. J. C. A., Hogenboom, A. C., Leonards, P. E. G., Peerboom, R. A. L., Cofino, W. P., & Brinkman, U. A. T. (1999) · Journal of Chromatography A · doi:10.1016/s0021-9673(99)00772-4 · Cited by 105
High-flow ion spray liquid chromatography/mass spectrometry
Gérard Hopfgartner, D., Wachs, T., Bean, K. A., & Henion, J. D. (1993) · Analytical Chemistry · doi:10.1021/ac00052a021 · Cited by 98
Theory of DNA electrophoresis: A look at some current challenges
Slater, G. W., Desruisseaux, C., Hubert, S. J., Mercier, J.-F., Labrie, J., Boileau, J., Tessier, F., & Pépin, M. P. (2000) · Electrophoresis · doi:10.1002/1522-2683(200012)21:18<4029::aid-elps4029>3.0.co;2-s · Cited by 95
Physical/chemical separations in the break-up of highly charged droplets from electrosprays
Tang, K., & Smith, R. D. (2001) · Journal of the American Society for Mass Spectrometry · doi:10.1016/s1044-0305(01)00222-7 · Cited by 94
Cech, N. B., & Enke, C. G. (2001) · Analytical Chemistry · doi:10.1021/ac001267j · Cited by 94
Self-citationInvestigation of the Gas-Phase Structure of Electrosprayed Proteins Using Ion-Molecule Reactions
Loo, R. R. O., & Smith, R. D. (1994) · Journal of the American Society for Mass Spectrometry · doi:10.1016/1044-0305(94)85011-9 · Cited by 93
Shen, X., & Perreault, H. (1998) · Journal of Chromatography A · doi:10.1016/s0021-9673(98)00238-6 · Cited by 93
Yoshino, K., Takao, T., Murata, H., & Shimonishi, Y. (1995) · Analytical Chemistry · doi:10.1021/ac00117a034 · Cited by 87
Berkel, G. J. V., & Asano, K. G. (1994) · Analytical Chemistry · doi:10.1021/ac00085a027 · Cited by 84
Applications of mass spectrometry to food proteins and peptides
Alomirah, H., Alli, I., & Konishi, Y. (2000) · Journal of Chromatography A · doi:10.1016/s0021-9673(00)00745-7 · Cited by 80
Geromanos, S. J., Freckleton, G., & Tempst, P. (2000) · Analytical Chemistry · doi:10.1021/ac991071n · Cited by 79
Characterization of protein glycosylation by mass spectrometry
Burlingame, A. L. (1996) · Current Opinion in Biotechnology · doi:10.1016/s0958-1669(96)80088-7 · Cited by 65
Huber, C. G., & Krajete, A. (2000) · Journal of Chromatography A · doi:10.1016/s0021-9673(99)00953-x · Cited by 61
Yeung, B., Porter, T. J., & Vath, J. E. (1997) · Analytical Chemistry · doi:10.1021/ac9611172 · Cited by 49
Ackloo, S. Z., Smith, R. W. P., Terlouw, J. K., & McCarry, B. E. (2000) · The Analyst · doi:10.1039/a908419c · Cited by 40
The b1 ion derived from methionine is a stable species
Tu, Y., & Harrison, A. G. (1998) · Rapid Communications in Mass Spectrometry · doi:10.1002/(sici)1097-0231(19980715)12:13<864::aid-rcm244>3.0.co;2-g · Cited by 26
Thielecke, F., & Noack, R. (1997) · Journal of Mass Spectrometry · doi:10.1002/(sici)1096-9888(199703)32:3<305::aid-jms482>3.0.co;2-r · Cited by 20
Electrospray ionization detection of inherently nonresponsive epoxides by peptide binding
Cech, N. B., Krone, J. R., & Enke, C. G. (2001) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.337 · Cited by 15
Self-citationHaley, T. M., Angier, S. J., Borthwick, A. D., Montgomery, D. S., Purvis, I. J., Smart, D. H., Bessant, C. M., Wely, C. V., & Hart, G. J. (1998) · Journal of Mass Spectrometry · doi:10.1002/(sici)1096-9888(199812)33:12<1199::aid-jms736>3.0.co;2-w · Cited by 8
Cited by
McDonnell, L. A., & Heeren, R. M. A. (2007) · Mass Spectrometry Reviews · doi:10.1002/mas.20124 · Cited by 1,082
Electrospray: From ions in solution to ions in the gas phase, what we know now
Kebarle, P., & Verkerk, U. H. (2009) · Mass Spectrometry Reviews · doi:10.1002/mas.20247 · Cited by 905
Organic Reactions in Microdroplets: Reaction Acceleration Revealed by Mass Spectrometry
Yan, X., Bain, R. M., & Cooks, R. G. (2016) · Angewandte Chemie International Edition · doi:10.1002/anie.201602270 · Cited by 583
Mallet, C. R., Lu, Z., & Mazzeo, J. R. (2004) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.1276 · Cited by 441
Best practices and benchmarks for intact protein analysis for top-down mass spectrometry
Donnelly, D. P., Rawlins, C. M., DeHart, C. J., Fornelli, L., Schachner, L. F., Lin, Z., Lippens, J. L., Aluri, K. C., Sarin, R., Chen, B., et al. (2019) · Nature Methods · doi:10.1038/s41592-019-0457-0 · Cited by 377
Metadata
- Authors
- Cech, N. B., & Enke, C. G.
- Venue
- Mass Spectrometry Reviews
- Publisher
- Wiley
- Published
- 2001-01
- Volume
- 20
- Issue
- 6
- Pages
- 362-387
- ISSN
- 0277-7037 (ISSN-L)
- 1098-2787
- OpenAlex
- W1978216187
- Cited by
- 1,435
- References
- 65
- FWCI
- 11.02
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.