The DOI matches its Crossref record; 65 of the 65 references it cites were found in a registry or an index.
Practical implications of some recent studies in electrospray ionization fundamentals
Abstract
I. Introduction 363 II. The Mechanics of ESI‐MS 363 III. Analyte Characteristics and Selectivity 365 A. Charging the Analyte 366 1. Ionization Through Charge Separation 366 2. Adduct Formation 366 3. Ionization Through Gas‐Phase Reactions 366 4. Ionization Through Electrochemical Oxidation or Reduction 368 B. Analyte Surface Activity and Its Effect on ESI Response 368 1. Surface Activity and the Fissioning Process 369 2. Predicting ESI Response from Other Parameters 369 C. The Role of Analyte p K a and Solvent pH 370 D. Improving ESI Response Through Derivatization 371 IV. The Working Curve and Dynamic Range 373 A. Detection Limits With ESI 373 1. Background Interferences 373 2. Random Noise 374 3. Ion Transmission and Sensitivity 374 B. Sources of Signal Saturation at High Concentrations 375 1. Limited Amount of Excess Charge 375 2. Limited Space on Droplet Surfaces 375 3. Suppression and Competition at High Concentrations 376 C. Improving the Detection Limit and Linear Dynamic Range 376 1. Extending to Higher Concentrations 376 2. Extending to Lower Concentrations 376 V. Instrumental Parameters and Stability 377 A. Current–Voltage Curves 377 B. Effect of Instrumental Parameters on the Current–Voltage Curve 378 C. Self‐Stabilizing Operation 379 D. Non‐Conductive vs. Conductive Spray Capillaries 379 VI. Solution Characteristics 380 A. The Ideal ESI Solvent 380 B. Solvent Choice for Analysis in the Positive Ion Mode 381 C. Solvent Choice for Analysis in the Negative Ion Mode 381 D. Compatibility Between ESI and Liquid Separation Techniques 382 VII. Summary 382 VIII. Acknowledgment 383 References 383 In accomplishing successful electrospray ionization analyses, it is imperative to have an understanding of the effects of variables such as analyte structure, instrumental parameters, and solution composition. Here, we review some fundamental studies of the ESI process that are relevant to these issues. We discuss how analyte chargeability and surface activity are related to ESI response, and how accessible parameters such as nonpolar surface area and reversed phase HPLC retention time can be used to predict relative ESI response. Also presented is a description of how derivitizing agents can be used to maximize or enable ESI response by improving the chargeability or hydrophobicity of ESI analytes. Limiting factors in the ESI calibration curve are discussed. At high concentrations, these factors include droplet surface area and excess charge concentration, whereas at low concentrations ion transmission becomes an issue, and chemical interference can also be limiting. Stable and reproducible non‐pneumatic ESI operation depends on the ability to balance a number of parameters, including applied voltage and solution surface tension, flow rate, and conductivity. We discuss how changing these parameters can shift the mode of ESI operation from stable to unstable, and how current–voltage curves can be used to characterize the mode of ESI operation. Finally, the characteristics of the ideal ESI solvent, including surface tension and conductivity requirements, are discussed. Analysis in the positive ion mode can be accomplished with acidified methanol/water solutions, but negative ion mode analysis necessitates special constituents that suppress corona discharge and facilitate the production of stable negative ions. © 2002 Wiley Periodicals, Inc., Mass Spec Rev 20: 362–387, 2001; Published online in Wiley InterScience (www.interscience.wiley.com). DOI 10.1002/mas.10008
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Electrospray Ionization for Mass Spectrometry of Large Biomolecules
Fenn, J. B., Mann, M., Meng, C. K., Wong, S. F., & Whitehouse, C. M. (1989) · Science · doi:10.1126/science.2675315 · Cited by 7,634
Analytical Properties of the Nanoelectrospray Ion Source
Wilm, M., & Mann, M. (1996) · Analytical Chemistry · doi:10.1021/ac9509519 · Cited by 1,868
Dole, M., Mack, L. L., Hines, R. L., Mobley, R. C., Ferguson, L. D., & Alice, M. B. (1968) · The Journal of Chemical Physics · doi:10.1063/1.1670391 · Cited by 1,613
On the evaporation of small ions from charged droplets
Iribarne, J. V., & Thomson, B. A. (1976) · The Journal of Chemical Physics · doi:10.1063/1.432536 · Cited by 1,281
Bonfiglio, R., King, R. C., Olah, T. V., & Merkle, K. (1999) · Rapid Communications in Mass Spectrometry · doi:10.1002/(sici)1097-0231(19990630)13:12<1175::aid-rcm639>3.0.co;2-0 · Cited by 939
The current emitted by highly conducting Taylor cones
De La Mora, J. F., & Loscertales, I. G. (1994) · Journal of Fluid Mechanics · doi:10.1017/s0022112094003472 · Cited by 884
Bruins, A. P., Covey, T. R., & Henion, J. D. (1987) · Analytical Chemistry · doi:10.1021/ac00149a003 · Cited by 879
From ions in solution to ions in the gas phase - the mechanism of electrospray mass spectrometry
Kebarle, P., & Tang, L. (1993) · Analytical Chemistry · doi:10.1021/ac00070a001 · Cited by 781
Charge and fission of droplets in electrostatic sprays
Gomez, A., & Tang, K. (1994) · Physics of Fluids · doi:10.1063/1.868037 · Cited by 654
Electrostatic spraying of liquids in cone-jet mode
Cloupeau, M., & Prunet-Foch, B. (1989) · Journal of Electrostatics · doi:10.1016/0304-3886(89)90081-8 · Cited by 616
Cited by
McDonnell, L. A., & Heeren, R. M. A. (2007) · Mass Spectrometry Reviews · doi:10.1002/mas.20124 · Cited by 1,082
Electrospray: From ions in solution to ions in the gas phase, what we know now
Kebarle, P., & Verkerk, U. H. (2009) · Mass Spectrometry Reviews · doi:10.1002/mas.20247 · Cited by 905
An overview of matrix effects in liquid chromatography–mass spectrometry
Trufelli, H., Palma, P., Famiglini, G., & Cappiello, A. (2011) · Mass Spectrometry Reviews · doi:10.1002/mas.20298 · Cited by 811
Unraveling the Mechanism of Electrospray Ionization
Konermann, L., Ahadi, E., Rodriguez, A. D., & Vahidi, S. (2013) · Analytical Chemistry · doi:10.1021/ac302789c · Cited by 735
Banerjee, S., & Mazumdar, S. (2012) · International Journal of Analytical Chemistry · doi:10.1155/2012/282574 · Cited by 662
Chemical derivatization and mass spectral libraries in metabolic profiling by GC/MS and LC/MS/MS
Halket, J. M., Waterman, D., Przyborowska, A. M., Patel, R. K. P., Fraser, P. D., & Bramley, P. M. (2005) · Journal of Experimental Botany · doi:10.1093/jxb/eri069 · Cited by 662
Mass spectrometry in metabolome analysis
Villas‐Bôas, S. G., Mas, S., Åkesson, M., Smedsgaard, J., & Nielsen, J. (2005) · Mass Spectrometry Reviews · doi:10.1002/mas.20032 · Cited by 616
Organic Reactions in Microdroplets: Reaction Acceleration Revealed by Mass Spectrometry
Yan, X., Bain, R. M., & Cooks, R. G. (2016) · Angewandte Chemie International Edition · doi:10.1002/anie.201602270 · Cited by 583
Advances in structure elucidation of small molecules using mass spectrometry
Kind, T., & Fiehn, O. (2010) · Bioanalytical Reviews · doi:10.1007/s12566-010-0015-9 · Cited by 480
Mass Spectrometry: Recent Advances in Direct Open Air Surface Sampling/Ionization
Monge, M. E., Harris, G. A., Dwivedi, P., & Fernández, F. M. (2013) · Chemical Reviews · doi:10.1021/cr300309q · Cited by 476
Mallet, C. R., Lu, Z., & Mazzeo, J. R. (2004) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.1276 · Cited by 441
Matrix Effects and Application of Matrix Effect Factor
Zhou, W., Yang, S., & Wang, P. G. (2017) · Bioanalysis · doi:10.4155/bio-2017-0214 · Cited by 430
Targeted Metabolomics for Biomarker Discovery
Griffiths, W. J., Koal, T., Wang, Y., Kohl, M., Enot, D. P., & Deigner, H. (2010) · Angewandte Chemie International Edition · doi:10.1002/anie.200905579 · Cited by 415
Challenges and emergent solutions for LC‐MS/MS based untargeted metabolomics in diseases
Cui, L., Lu, H., & Lee, Y. H. (2018) · Mass Spectrometry Reviews · doi:10.1002/mas.21562 · Cited by 415
Effect of eluent on the ionization process in liquid chromatography–mass spectrometry
Kostiainen, R., & Kauppila, T. J. (2009) · Journal of Chromatography A · doi:10.1016/j.chroma.2008.08.095 · Cited by 402
Guo, K., & Li, L. (2009) · Analytical Chemistry · doi:10.1021/ac900166a · Cited by 396
Best practices and benchmarks for intact protein analysis for top-down mass spectrometry
Donnelly, D. P., Rawlins, C. M., DeHart, C. J., Fornelli, L., Schachner, L. F., Lin, Z., Lippens, J. L., Aluri, K. C., Sarin, R., Chen, B., et al. (2019) · Nature Methods · doi:10.1038/s41592-019-0457-0 · Cited by 377
Probing protein structure by amino acid‐specific covalent labeling and mass spectrometry
Mendoza, V. L., & Vachet, R. W. (2009) · Mass Spectrometry Reviews · doi:10.1002/mas.20203 · Cited by 364
Microbial metabolomics: past, present and future methodologies
Mashego, M. R., Rumbold, K., De Mey, M., Vandamme, E., Soetaert, W., & Heijnen, J. J. (2007) · Biotechnology Letters · doi:10.1007/s10529-006-9218-0 · Cited by 360
Kuehnbaum, N. L., & Britz-McKibbin, P. (2013) · Chemical Reviews · doi:10.1021/cr300484s · Cited by 354
Tutorial review on validation of liquid chromatography–mass spectrometry methods: Part II
Kruve, A., Rebane, R., Kipper, K., Oldekop, M.-L., Evard, H., Herodes, K., Ravio, P., & Leito, I. (2015) · Analytica Chimica Acta · doi:10.1016/j.aca.2015.02.016 · Cited by 338
Internal energy and fragmentation of ions produced in electrospray sources
Gabelica, V., & Pauw, E. D. (2005) · Mass Spectrometry Reviews · doi:10.1002/mas.20027 · Cited by 338
Proteomics of Integral Membrane ProteinsTheory and Application
Speers, A. E., & Wu, C. C. (2007) · Chemical Reviews · doi:10.1021/cr068286z · Cited by 325
Lin, P., Rincon, A. G., Kalberer, M., & Yu, J. Z. (2012) · Environmental Science & Technology · doi:10.1021/es300285d · Cited by 330
Vitamin D in plants: a review of occurrence, analysis, and biosynthesis
Jäpelt, R. B., & Jakobsen, J. (2013) · Frontiers in Plant Science · doi:10.3389/fpls.2013.00136 · Cited by 327
Electrospray Ionization Efficiency Scale of Organic Compounds
Oss, M., Kruve, A., Herodes, K., & Leito, I. (2010) · Analytical Chemistry · doi:10.1021/ac902856t · Cited by 309
Wang, M., Wang, C., & Han, X. (2017) · Mass Spectrometry Reviews · doi:10.1002/mas.21492 · Cited by 301
Tutorial review on validation of liquid chromatography–mass spectrometry methods: Part I
Kruve, A., Rebane, R., Kipper, K., Oldekop, M.-L., Evard, H., Herodes, K., Ravio, P., & Leito, I. (2015) · Analytica Chimica Acta · doi:10.1016/j.aca.2015.02.017 · Cited by 300
Van Berkel, G. J., Pasilis, S. P., & Ovchinnikova, O. (2008) · Journal of Mass Spectrometry · doi:10.1002/jms.1440 · Cited by 299
Prediction of high-responding peptides for targeted protein assays by mass spectrometry
Fusaro, V. A., Mani, D. R., Mesirov, J. P., & Carr, S. A. (2009) · Nature Biotechnology · doi:10.1038/nbt.1524 · Cited by 293
Nguyen, H. P., & Schug, K. A. (2008) · Journal of Separation Science · doi:10.1002/jssc.200700630 · Cited by 275
Beyond the paradigm: Combining mass spectrometry and nuclear magnetic resonance for metabolomics
Marshall, D. D., & Powers, R. (2017) · Progress in Nuclear Magnetic Resonance Spectroscopy · doi:10.1016/j.pnmrs.2017.01.001 · Cited by 270
Piraud, M., Vianey‐Saban, C., Petritis, K., Elfakir, C., Steghens, J., Morla, A., & Bouchu, D. (2003) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.1054 · Cited by 266
Ionization and transmission efficiency in an electrospray ionization—mass spectrometry interface
Page, J. S., Kelly, R. T., Tang, K., & Smith, R. D. (2007) · Journal of the American Society for Mass Spectrometry · doi:10.1016/j.jasms.2007.05.018 · Cited by 265
Tang, K., Page, J. S., & Smith, R. D. (2004) · Journal of the American Society for Mass Spectrometry · doi:10.1016/j.jasms.2004.04.034 · Cited by 262
The Composition of Ehrlich's Salvarsan: Resolution of a Century‐Old Debate
Lloyd, N. C., Morgan, H. W., Nicholson, B. K., & Ronimus, R. S. (2005) · Angewandte Chemie International Edition · doi:10.1002/anie.200461471 · Cited by 256
González, O., Blanco, M. E., Iriarte, G., Bartolomé, L., Maguregui, M. I., & Alonso, R. M. (2014) · Journal of Chromatography A · doi:10.1016/j.chroma.2014.03.077 · Cited by 253
On the Scalability and Requirements of Whole Protein Mass Spectrometry
Compton, P. D., Zamdborg, L., Thomas, P. M., & Kelleher, N. L. (2011) · Analytical Chemistry · doi:10.1021/ac2010795 · Cited by 243
The Revolution and Evolution of Shotgun Proteomics for Large-Scale Proteome Analysis
Yates, J. R. (2013) · Journal of the American Chemical Society · doi:10.1021/ja3094313 · Cited by 131
Muneeruddin, K., Nazzaro, M., & Kaltashov, I. A. (2015) · Analytical Chemistry · doi:10.1021/acs.analchem.5b02982 · Cited by 98
Mullin, L., Katz, D. R., Riddell, N., Plumb, R., Burgess, J. A., Yeung, L. W. Y., & Jogsten, I. E. (2019) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2019.05.015 · Cited by 91
Höcker, O., Montealegre, C., & Neusüß, C. (2018) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-018-1179-3 · Cited by 55
Evaluation of a sheathless nanospray interface based on a porous tip sprayer for CE‐ESI‐MS coupling
Bonvin, G., Veuthey, J., Rudaz, S., & Schappler, J. (2012) · ELECTROPHORESIS · doi:10.1002/elps.201100461 · Cited by 48
Santa, T., Al‐Dirbashi, O. Y., Yoshikado, T., Fukushima, T., & Imai, K. (2009) · Biomedical Chromatography · doi:10.1002/bmc.1124 · Cited by 17
Canzani, D., Rusnac, D.-V., Zheng, N., & Bush, M. F. (2019) · Analytical Chemistry · doi:10.1021/acs.analchem.9b02331 · Cited by 11
Metadata
- Authors
- Cech, N. B., & Enke, C. G.
- Venue
- Mass Spectrometry Reviews
- Publisher
- Wiley
- Published
- 2001-01
- Volume
- 20
- Issue
- 6
- Pages
- 362-387
- ISSN
- 0277-7037 (ISSN-L)
- 1098-2787
- OpenAlex
- W1978216187
- Cited by
- 1,435
- References
- 65
- FWCI
- 11.02
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.