The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
The NMR phased array
Abstract
We describe methods for simultaneously acquiring and subsequently combining data from a multitude of closely positioned NMR receiving coils. The approach is conceptually similar to phased array radar and ultrasound and hence we call our techniques the “NMR phased array.” The NMR phased array offers the signal‐to‐noise ratio (SNR) and resolution of a small surface coil over fields‐of‐view (FOV) normally associated with body imaging with no increase in imaging time. The NMR phased array can be applied to both imaging and spectroscopy for all pulse sequences. The problematic interactions among nearby surface coils is eliminated (a) by overlapping adjacent coils to give zero mutual inductance, hence zero interaction, and (b) by attaching low input impedance preamplifiers to all coils, thus eliminating interference among next nearest and more distant neighbors. We derive an algorithm for combining the data from the phased array elements to yield an image with optimum SNR. Other techniques which are easier to implement at the cost of lower SNR are explored. Phased array imaging is demonstrated with high resolution (512 × 512, 48‐cm FOV, and 32‐cm FOV) spin‐echo images of the thoracic and lumbar spine. Data were acquired from four‐element linear spine arrays, the first made of 12‐cm square coils and the second made of 8‐cm square coils. When compared with images from a single 15 × 30‐cm rectangular coil and identical imaging parameters, the phased array yields a 2X and 3X higher SNR at the depth of the spine ( ∼ 7 cm). © 1990 Academic Press, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The signal-to-noise ratio of the nuclear magnetic resonance experiment
Hoult, D. I., & Richards, R. E. (1976) · Journal of Magnetic Resonance (1969) · doi:10.1016/0022-2364(76)90233-x · Cited by 1,132
Static and Dynamic Electricity
TEMPLE, G. (1940) · Nature · doi:10.1038/146446a0 · Cited by 1,122
Comparison of Interpolating Methods for Image Resampling
Parker, J. A., Kenyon, R. V., & Troxel, D. E. (1983) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.1983.4307610 · Cited by 829
The intrinsic signal-to-noise ratio in NMR imaging
Edelstein, W. A., Glover, G. H., Hardy, C. J., & Redington, R. W. (1986) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910030413 · Cited by 758
Self-citationComparison of linear and circular polarization for magnetic resonance imaging
Glover, G. H., Hayes, C. E., Pelc, N. J., Edelstein, W. A., Mueller, O. M., Hart, H. R., Hardy, C. J., O'Donnell, M., & Barber, W. D. (1985) · Journal of Magnetic Resonance (1969) · doi:10.1016/0022-2364(85)90349-x · Cited by 265
Self-citationIntensity correction in surface-coil MR imaging
Axel, L., Costantini, J., & Listerud, J. (1987) · American Journal of Roentgenology · doi:10.2214/ajr.148.2.418 · Cited by 240
Image restoration from non-uniform magnetic field influence for direct Fourier NMR imaging
Sekihara, K., Kuroda, M., & Kohno, H. (1984) · Physics in Medicine and Biology · doi:10.1088/0031-9155/29/1/002 · Cited by 76
Cited by
SENSE: Sensitivity encoding for fast MRI
Pruessmann, K. P., Weiger, M., Scheidegger, M. B., & Boesiger, P. (1999) · Magnetic Resonance in Medicine · doi:10.1002/(sici)1522-2594(199911)42:5<952::aid-mrm16>3.0.co;2-s · Cited by 6,251
Generalized autocalibrating partially parallel acquisitions (GRAPPA)
Griswold, M. A., Jakob, P. M., Heidemann, R. M., Nittka, M., Jellus, V., Wang, J., Kiefer, B., & Haase, A. (2002) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10171 · Cited by 5,303
Simultaneous acquisition of spatial harmonics (SMASH): Fast imaging with radiofrequency coil arrays
Sodickson, D. K., & Manning, W. J. (1997) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910380414 · Cited by 2,142
MP2RAGE, a self bias-field corrected sequence for improved segmentation and T1-mapping at high field
Marques, J. P., Kober, T., Krueger, G., van der Zwaag, W., Van de Moortele, P.-F., & Gruetter, R. (2010) · NeuroImage · doi:10.1016/j.neuroimage.2009.10.002 · Cited by 1,453
Advances in sensitivity encoding with arbitrary k‐space trajectories
Pruessmann, K. P., Weiger, M., Börnert, P., & Boesiger, P. (2001) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1241 · Cited by 1,211
Dietrich, O., Raya, J. G., Reeder, S. B., Reiser, M. F., & Schoenberg, S. O. (2007) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.20969 · Cited by 992
The neural basis of the blood–oxygen–level–dependent functional magnetic resonance imaging signal
Logothetis, N. K. (2002) · Philosophical Transactions of the Royal Society of London. Series B: Biological Sciences · doi:10.1098/rstb.2002.1114 · Cited by 958
Uğurbil, K., Xu, J., Auerbach, E. J., Moeller, S., Vu, A. T., Duarte-Carvajalino, J. M., Lenglet, C., Wu, X., Schmitter, S., Van de Moortele, P. F., et al. (2013) · NeuroImage · doi:10.1016/j.neuroimage.2013.05.012 · Cited by 812
Quantitative susceptibility mapping (QSM): Decoding MRI data for a tissue magnetic biomarker
Wang, Y., & Liu, T. (2015) · Magnetic Resonance in Medicine · doi:10.1002/mrm.25358 · Cited by 878
SPIRiT: Iterative self‐consistent parallel imaging reconstruction from arbitrary k‐space
Lustig, M., & Pauly, J. M. (2010) · Magnetic Resonance in Medicine · doi:10.1002/mrm.22428 · Cited by 822
Diffusion models in medical imaging: A comprehensive survey
Kazerouni, A., Aghdam, E. K., Heidari, M., Azad, R., Fayyaz, M., Hacihaliloglu, I., & Merhof, D. (2023) · Medical Image Analysis · doi:10.1016/j.media.2023.102846 · Cited by 765
High-field MRI of brain cortical substructure based on signal phase
Duyn, J. H., van Gelderen, P., Li, T.-Q., de Zwart, J. A., Koretsky, A. P., & Fukunaga, M. (2007) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0610821104 · Cited by 641
Deshmane, A., Gulani, V., Griswold, M. A., & Seiberlich, N. (2012) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.23639 · Cited by 606
Otazo, R., Kim, D., Axel, L., & Sodickson, D. K. (2010) · Magnetic Resonance in Medicine · doi:10.1002/mrm.22463 · Cited by 571
Pros and cons of ultra-high-field MRI/MRS for human application
Ladd, M. E., Bachert, P., Meyerspeer, M., Moser, E., Nagel, A. M., Norris, D. G., Schmitter, S., Speck, O., Straub, S., & Zaiss, M. (2018) · Progress in Nuclear Magnetic Resonance Spectroscopy · doi:10.1016/j.pnmrs.2018.06.001 · Cited by 544
Image reconstruction in SNR units: A general method for SNR measurement†
Kellman, P., & McVeigh, E. R. (2005) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20713 · Cited by 535
fastMRI: An Open Dataset and Benchmarks for Accelerated MRI
Žbontar, J., Knöll, F., Sriram, A., Murrell, T., Huang, Z., Muckley, M. J., Defazio, A., Stern, R., Johnson, P., Bruno, M. T., et al. (2018) · arXiv (Cornell University) · doi:10.48550/arxiv.1811.08839 · Cited by 528
Evaluation of slice accelerations using multiband echo planar imaging at 3T
Xu, J., Moeller, S., Auerbach, E. J., Strupp, J., Smith, S. M., Feinberg, D. A., Yacoub, E., & Uğurbil, K. (2013) · NeuroImage · doi:10.1016/j.neuroimage.2013.07.055 · Cited by 514
Signal‐to‐noise measurements in magnitude images from NMR phased arrays
Constantinides, C. D., Atalar, E., & McVeigh, E. R. (1997) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910380524 · Cited by 510
Multicoil Dixon chemical species separation with an iterative least‐squares estimation method
Reeder, S. B., Wen, Z., Yu, H., Pineda, A. R., Gold, G. E., Markl, M., & Pelc, N. J. (2004) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10675 · Cited by 508
Comprehensive cellular‐resolution atlas of the adult human brain
Ding, S., Royall, J. J., Sunkin, S. M., Ng, L., Facer, B. A. C., Lesnar, P., Guillozet‐Bongaarts, A., McMurray, B., Szafer, A., Dolbeare, T. A., et al. (2016) · Journal of Comparative Neurology · doi:10.1002/cne.24080 · Cited by 447
Methodological consensus on clinical proton MRS of the brain: Review and recommendations
Wilson, M., Andronesi, O., Barker, P. B., Bartha, R., Bizzi, A., Bolan, P. J., Brindle, K. M., Choi, I., Cudalbu, C., Dydak, U., et al. (2019) · Magnetic Resonance in Medicine · doi:10.1002/mrm.27742 · Cited by 470
B1 destructive interferences and spatial phase patterns at 7 T with a head transceiver array coil
Van de Moortele, P., Akgun, C., Adriany, G., Moeller, S., Ritter, J., Collins, C. M., Smith, M. B., Vaughan, J. T., & Uğurbil, K. (2005) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20708 · Cited by 468
Deistung, A., Schäfer, A., Schweser, F., Biedermann, U., Turner, R., & Reichenbach, J. R. (2013) · NeuroImage · doi:10.1016/j.neuroimage.2012.09.055 · Cited by 442
Robson, P. M., Grant, A. K., Madhuranthakam, A. J., Lattanzi, R., Sodickson, D. K., & McKenzie, C. A. (2008) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21728 · Cited by 438
Transmit and receive transmission line arrays for 7 Tesla parallel imaging
Adriany, G., Van de Moortele, P., Wiesinger, F., Moeller, S., Strupp, J. P., Andersen, P., Snyder, C., Zhang, X., Chen, W., Pruessmann, K. P., et al. (2005) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20321 · Cited by 421
Score-based diffusion models for accelerated MRI
Chung, H., & Ye, J. C. (2022) · Medical Image Analysis · doi:10.1016/j.media.2022.102479 · Cited by 421
Larson, A. C., White, R. D., Laub, G., McVeigh, E. R., Li, D., & Simonetti, O. P. (2004) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10664 · Cited by 419
Low‐field MRI: An MR physics perspective
Marques, J. P., Simonis, F. F. J., & Webb, A. G. (2019) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.26637 · Cited by 386
32‐channel 3 Tesla receive‐only phased‐array head coil with soccer‐ball element geometry
Wiggins, G. C., Triantafyllou, C., Potthast, A., Reykowski, A., Nittka, M., & Wald, L. L. (2006) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20925 · Cited by 375
Zaitsev, M., Hennig, J., & Speck, O. (2004) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20261 · Cited by 349
Multi-compartment microscopic diffusion imaging
Kaden, E., Kelm, N. D., Carson, R. P., Does, M. D., & Alexander, D. C. (2016) · NeuroImage · doi:10.1016/j.neuroimage.2016.06.002 · Cited by 345
Near, J., Harris, A. D., Juchem, C., Kreis, R., Marjańska, M., Öz, G., Slotboom, J., Wilson, M., & Gasparovic, C. (2021) · NMR in Biomedicine · doi:10.1002/nbm.4257 · Cited by 342
Overview of quantitative susceptibility mapping
Deistung, A., Schweser, F., & Reichenbach, J. R. (2017) · NMR in Biomedicine · doi:10.1002/nbm.3569 · Cited by 338
Model-Based Image Reconstruction for MRI
Fessler, J. (2010) · IEEE Signal Processing Magazine · doi:10.1109/msp.2010.936726 · Cited by 335
Partially parallel imaging with localized sensitivities (PILS)
Griswold, M. A., Jakob, P. M., Nittka, M., Goldfarb, J. W., & Haase, A. (2000) · Magnetic Resonance in Medicine · doi:10.1002/1522-2594(200010)44:4<602::aid-mrm14>3.0.co;2-5 · Cited by 329
Parallel magnetic resonance imaging
Larkman, D. J., & Nunes, R. G. (2007) · Physics in Medicine and Biology · doi:10.1088/0031-9155/52/7/r01 · Cited by 327
Results of the 2020 fastMRI challenge for machine learning MR image reconstruction
Muckley, M. J., Riemenschneider, B., Radmanesh, A., Kim, S., Jeong, G., Ko, J., Jun, Y., Shin, H., Hwang, D., Mostapha, M., et al. (2021) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2021.3075856 · Cited by 313
Analytically exact correction scheme for signal extraction from noisy magnitude MR signals
Koay, C. G., & Basser, P. J. (2006) · Journal of Magnetic Resonance · doi:10.1016/j.jmr.2006.01.016 · Cited by 312
High magnetic field water and metabolite proton T1 and T2 relaxation in rat brain in vivo
de Graaf, R. A., Brown, P. B., McIntyre, S., Nixon, T. W., Behar, K. L., & Rothman, D. L. (2006) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20946 · Cited by 304
A survey on the magnetic resonance image denoising methods
Mohan, J., Krishnaveni, V., & Guo, Y. (2014) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2013.10.007 · Cited by 295
In Vivo Quantitative Susceptibility Mapping (QSM) in Alzheimer's Disease
Acosta-Cabronero, J., Williams, G. B., Cardenas-Blanco, A., Arnold, R. J., Lupson, V., & Nestor, P. J. (2013) · PLoS ONE · doi:10.1371/journal.pone.0081093 · Cited by 287
Theory and application of array coils in MR spectroscopy
Wright, S. M., & Wald, L. L. (1997) · NMR in Biomedicine · doi:10.1002/(sici)1099-1492(199712)10:8<394::aid-nbm494>3.0.co;2-0 · Cited by 286
DREAM—a novel approach for robust, ultrafast, multislice B1 mapping
Nehrke, K., & Börnert, P. (2012) · Magnetic Resonance in Medicine · doi:10.1002/mrm.24158 · Cited by 282
96‐Channel receive‐only head coil for 3 Tesla: Design optimization and evaluation
Wiggins, G. C., Polimeni, J. R., Potthast, A., Schmitt, M., Alagappan, V., & Wald, L. L. (2009) · Magnetic Resonance in Medicine · doi:10.1002/mrm.22028 · Cited by 274
Coil compression for accelerated imaging with Cartesian sampling
Zhang, T., Pauly, J. M., Vasanawala, S. S., & Lustig, M. (2013) · Magnetic Resonance in Medicine · doi:10.1002/mrm.24267 · Cited by 273
Three‐dimensional radial ultrashort echo‐time imaging with T2 adapted sampling
Rahmer, J., Börnert, P., Groen, J., & Bos, C. (2006) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20868 · Cited by 273
Van de Moortele, P.-F., Auerbach, E. J., Olman, C., Yacoub, E., Uğurbil, K., & Moeller, S. (2009) · NeuroImage · doi:10.1016/j.neuroimage.2009.02.009 · Cited by 265
Knoll, F., Murrell, T., Sriram, A., Yakubova, N., Zbontar, J., Rabbat, M., Defazio, A., Muckley, M. J., Sodickson, D. K., Zitnick, C. L., et al. (2020) · Magnetic Resonance in Medicine · doi:10.1002/mrm.28338 · Cited by 263
A 64‐channel 3T array coil for accelerated brain MRI
Keil, B., Blau, J. N., Biber, S., Hoecht, P., Tountcheva, V., Setsompop, K., Triantafyllou, C., & Wald, L. L. (2013) · Magnetic Resonance in Medicine · doi:10.1002/mrm.24427 · Cited by 260
Array compression for MRI with large coil arrays
Buehrer, M., Pruessmann, K. P., Boesiger, P., & Kozerke, S. (2007) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21237 · Cited by 257
Dietrich, O., Raya, J. G., Reeder, S. B., Ingrisch, M., Reiser, M. F., & Schoenberg, S. O. (2008) · Magnetic Resonance Imaging · doi:10.1016/j.mri.2008.02.001 · Cited by 254
WONDERLICK, J., ZIEGLER, D., HOSSEINIVARNAMKHASTI, P., LOCASCIO, J., BAKKOUR, A., VANDERKOUWE, A., TRIANTAFYLLOU, C., CORKIN, S., & DICKERSON, B. (2009) · NeuroImage · doi:10.1016/j.neuroimage.2008.10.037 · Cited by 221
Linear inverse problems in imaging
Ribes, A., & Schmitt, F. (2008) · IEEE Signal Processing Magazine · doi:10.1109/msp.2008.923099 · Cited by 154
An fMRI investigation of posttraumatic flashbacks
Whalley, M. G., Kroes, M. C. W., Huntley, Z., Rugg, M. D., Davis, S. W., & Brewin, C. R. (2013) · Brain and Cognition · doi:10.1016/j.bandc.2012.10.002 · Cited by 115
Scalable multichannel MRI data acquisition system
Bodurka, J., Ledden, P. J., van Gelderen, P., Chu, R., de Zwart, J. A., Morris, D., & Duyn, J. H. (2004) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10693 · Cited by 71
Lee, R. F., Dai, W., & Jones, J. (2012) · Magnetic Resonance in Medicine · doi:10.1002/mrm.23313 · Cited by 32
Rausch, I., Valladares, A., Sundar, L. K. S., Beyer, T., Hacker, M., Meyerspeer, M., & Unger, E. (2021) · EJNMMI Physics · doi:10.1186/s40658-021-00364-9 · Cited by 11
Metadata
- Authors
- Roemer, P. B., Edelstein, W. A., Hayes, C. E., Souza, S. P., & Mueller, O. M.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 1990-11
- Volume
- 16
- Issue
- 2
- Pages
- 192-225
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W2013816305
- Cited by
- 2,322
- References
- 7
- FWCI
- 12.85
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.