The DOI matches its Crossref record; 27 of the 27 references it cites were found in a registry or an index.
MR fingerprinting using fast imaging with steady state precession (FISP) with spiral readout: MR Fingerprinting with FISP
Open accessAbstract
PURPOSE: This study explores the possibility of using gradient echo-based sequences other than balanced steady-state free precession (bSSFP) in the magnetic resonance fingerprinting (MRF) framework to quantify the relaxation parameters . METHODS: An MRF method based on a fast imaging with steady-state precession (FISP) sequence structure is presented. A dictionary containing possible signal evolutions with physiological range of T1 and T2 was created using the extended phase graph formalism according to the acquisition parameters. The proposed method was evaluated in a phantom and a human brain. T1 , T2 , and proton density were quantified directly from the undersampled data by the pattern recognition algorithm. RESULTS: T1 and T2 values from the phantom demonstrate that the results of MRF FISP are in good agreement with the traditional gold-standard methods. T1 and T2 values in brain are within the range of previously reported values. CONCLUSION: MRF-FISP enables a fast and accurate quantification of the relaxation parameters. It is immune to the banding artifact of bSSFP due to B0 inhomogeneities, which could improve the ability to use MRF for applications beyond brain imaging.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Magnetic resonance fingerprinting
Ma, D., Gulani, V., Seiberlich, N., Liu, K., Sunshine, J. L., Duerk, J. L., & Griswold, M. A. (2013) · Nature · doi:10.1038/nature11971 · Cited by 1,577 · cited 6×
“Magnetic resonance fingerprinting (MRF) (13) is a novel concept in quantitative imaging that aims to overcome many of these limitations.”
BackgroundMethodResultInfluentialModified Look‐Locker inversion recovery (MOLLI) for high‐resolution T1 mapping of the heart
Messroghli, D. R., Radjenovic, A., Kozerke, S., Higgins, D. M., Sivananthan, M. U., & Ridgway, J. P. (2004) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20110 · Cited by 1,349
Nonuniform fast fourier transforms using min-max interpolation
Fessler, J. A., & Sutton, B. P. (2003) · IEEE Transactions on Signal Processing · doi:10.1109/tsp.2002.807005 · Cited by 1,337
Time Saving in Measurement of NMR and EPR Relaxation Times
Look, D. C., & Locker, D. R. (1970) · Review of Scientific Instruments · doi:10.1063/1.1684482 · Cited by 819
Rapid combined T1 and T2 mapping using gradient recalled acquisition in the steady state
Deoni, S. C. L., Rutt, B. K., & Peters, T. M. (2003) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10407 · Cited by 744
Rapid magnetic resonance quantification on the brain: Optimization for clinical usage
Warntjes, J. B. M., Leinhard, O. D., West, J., & Lundberg, P. (2008) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21635 · Cited by 500
Robson, P. M., Grant, A. K., Madhuranthakam, A. J., Lattanzi, R., Sodickson, D. K., & McKenzie, C. A. (2008) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21728 · Cited by 438
Extended phase graphs: Dephasing, RF pulses, and echoes ‐ pure and simple
Weigel, M. (2015) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.24619 · Cited by 426
Multiecho imaging sequences with low refocusing flip angles
Hennig, J. (1988) · Journal of Magnetic Resonance (1969) · doi:10.1016/0022-2364(88)90128-x · Cited by 403
Simple Correction Method fork-Space Trajectory Deviations in MRI
Duyn, J. H., Yang, Y., Frank, J. A., & van der Veen, J. W. (1998) · Journal of Magnetic Resonance · doi:10.1006/jmre.1998.1396 · Cited by 359
Cheng, H. M., & Wright, G. A. (2006) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20791 · Cited by 351
Compressed sensing reconstruction for magnetic resonance parameter mapping
Doneva, M., Börnert, P., Eggers, H., Stehning, C., Sénégas, J., & Mertins, A. (2010) · Magnetic Resonance in Medicine · doi:10.1002/mrm.22483 · Cited by 326
Hennig, J., Weigel, M., & Scheffler, K. (2003) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10391 · Cited by 244
Inversion recovery TrueFISP: Quantification of T1, T2, and spin density
Schmitt, P., Griswold, M. A., Jakob, P. M., Kotas, M., Gulani, V., Flentje, M., & Haase, A. (2004) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20058 · Cited by 242
Self-citationHennig, J. (1991) · Concepts in Magnetic Resonance · doi:10.1002/cmr.1820030302 · Cited by 241
Practical medical applications of quantitative MR relaxometry
Margaret Cheng, H., Stikov, N., Ghugre, N. R., & Wright, G. A. (2012) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.23718 · Cited by 238
Novel method for rapid, simultaneous T1, T*2, and proton density quantification
Warntjes, J. B. M., Dahlqvist, O., & Lundberg, P. (2007) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21165 · Cited by 219
Transverse relaxometry with stimulated echo compensation
Lebel, R. M., & Wilman, A. H. (2010) · Magnetic Resonance in Medicine · doi:10.1002/mrm.22487 · Cited by 187
Ehses, P., Seiberlich, N., Ma, D., Breuer, F., Jakob, P. M., Griswold, M. A., & Gulani, V. (2012) · Magnetic Resonance in Medicine · doi:10.1002/mrm.24225 · Cited by 103
Self-citationDeshpande, V. S., Chung, Y., Zhang, Q., Shea, S. M., & Li, D. (2002) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10337 · Cited by 101
Fast 3D imaging using variable‐density spiral trajectories with applications to limb perfusion
Lee, J. H., Hargreaves, B. A., Hu, B. S., & Nishimura, D. G. (2003) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10644 · Cited by 100
Zhu, D. C., & Penn, R. D. (2005) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20602 · Cited by 82
MT effects and T1 quantification in single‐slice spoiled gradient echo imaging
Ou, X., & Gochberg, D. F. (2008) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21550 · Cited by 62
Triple‐echo steady‐state T 2 relaxometry of the human brain at high to ultra‐high fields
Heule, R., Bär, P., Mirkes, C., Scheffler, K., Trattnig, S., & Bieri, O. (2014) · NMR in Biomedicine · doi:10.1002/nbm.3152 · Cited by 28
Nonbalanced SSFP‐based quantitative magnetization transfer imaging
Gloor, M., Scheffler, K., & Bieri, O. (2010) · Magnetic Resonance in Medicine · doi:10.1002/mrm.22331 · Cited by 24
Wansapura (1999) · doi:10.1002/(sici)1522-2586(199904)9:4
Grieve (2000) · doi:10.1002/(sici)1522-2594(200005)43:5
Cited by
Magnetic resonance fingerprinting
Ma, D., Gulani, V., Seiberlich, N., Liu, K., Sunshine, J. L., Duerk, J. L., & Griswold, M. A. (2013) · Nature · doi:10.1038/nature11971 · Cited by 1,577
MR fingerprinting Deep RecOnstruction NEtwork (DRONE)
Cohen, O., Zhu, B., & Rosen, M. S. (2018) · Magnetic Resonance in Medicine · doi:10.1002/mrm.27198 · Cited by 306
What are normal relaxation times of tissues at 3 T?
Bojorquez, J. Z., Bricq, S., Acquitter, C., Brunotte, F., Walker, P. M., & Lalande, A. (2017) · Magnetic Resonance Imaging · doi:10.1016/j.mri.2016.08.021 · Cited by 286
Fast 3D magnetic resonance fingerprinting for a whole‐brain coverage
Ma, D., Jiang, Y., Chen, Y., McGivney, D., Mehta, B., Gulani, V., & Griswold, M. (2018) · Magnetic Resonance in Medicine · doi:10.1002/mrm.26886 · Cited by 158
Self-citationRieger, B., Akçakaya, M., Pariente, J. C., Llufriu, S., Martinez-Heras, E., Weingärtner, S., & Schad, L. R. (2018) · Scientific Reports · doi:10.1038/s41598-018-24920-z · Cited by 39
Metadata
- Authors
- Jiang, Y., Ma, D., Seiberlich, N., Gulani, V., & Griswold, M. A.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 2014-12-09
- Volume
- 74
- Issue
- 6
- Pages
- 1621-1631
- ISSN
- 0740-3194 (ISSN-L)
- OpenAlex
- W1510815927
- Cited by
- 422
- References
- 27
- FWCI
- 14.19
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.