Abstract
Methods overview for chronometric geodesy and applications to geopotential and height-related problems.
Overview
CoChat Summary
## TL;DR
The chapter explains chronometric geodesy as the use of atomic clocks to measure gravity potential differences and to support both clock synchronization and geodetic height/geoid determination. It argues that at current clock performance, optical-clock comparisons can reach the centimeter level and are becoming competitive with classical geodetic methods, especially when combined with GNSS and gravimetric models.
## Key findings
- Chronometric geodesy is defined as using clocks to determine the space-time metric; the paper states that with clock comparisons at 10^-16 accuracy, one can determine height differences with 1 m accuracy or geopotential differences with 10 m² s^-2 accuracy.
- In the ITOC project, unified relativistic redshift corrections were derived for PTB and LNE-SYRTE; the paper reports an uncertainty of about 2 × 10^-18 for the GNSS/geoid-based corrections.
- The paper reports that for the ITOC sites, GNSS/levelling versus quasigeoid comparisons gave RMS residuals of 11 mm (INRIM), 5 mm (LNE-SYRTE), 6 mm (NPL), 4 mm (PTB), and 17 mm (LSM).
- In synthetic geoid-reconstruction tests, using 4374 gravimetric data alone gave a bias of about 0.041 m² s^-2 (4.1 mm) and RMS of 0.25 m² s^-2 (2.5 cm), while adding 33 clock-based potential measurements improved these to about -0.002 m² s^-2 (-0.2 mm) bias and 0.07 m² s^-2 (7 mm) RMS.
## Methods
- The chapter is a conceptual and methodological review organized around general relativity, frequency transfer, and geodetic potential determination, with an application section based on the ITOC project and a simulation study on geoid determination.
- For the ITOC part, the paper uses GNSS and levelling campaigns at metrology institutes including INRIM, LNE-SYRTE, NPL, PTB, and LSM, combined with the EGG2015 gravimetric quasigeoid model and EVRF2007 height transformations.
- For the geoid-contribution study, it uses synthetic gravity and clock/potential data, a 10-km grid, and Least-Squares Collocation (LSC) with a logarithmic 3D covariance model to compare reconstructions with and without clock data.
## Limitations
- The paper explicitly notes that the GNSS/geoid approach depends strongly on the quality and coverage of ground gravimetric observables and that its best-case uncertainty estimates assume high-resolution regional gravity field models and sufficient terrestrial data.
- It states that geometric levelling accumulates systematic errors over long distances and that levelling across countries can be affected by different tide gauges and outdated observations; this is presented as a limitation of the method.
- Evident from the text: some numerical results are presented as best-case scenarios or based on synthetic data, so the reported improvements from clocks in geoid recovery may not directly transfer to all real-world settings.
Model-written summary. Check it against the paper before relying on it.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
27 Valid · 10 Not valid · 40 Not checked · 158 Own results and interpretations
The cited sources support only part of this claim — read each source’s verdict below.
In the paper
“If the signal propagates in an optical fibre, the term (d t B / d t A ) has been calculated up to order c -3 in [122] for one-way and two-way time and frequency transfers.”
What the sources say
- Partly supportedcites [122] [122] J. Ger˘ sl, P. Delva, and P. Wolf. Relativistic corrections for time and frequency transfer in optical fibres. Metrologia , 52(4):552, 2015. - sourceExperimental — accuracy not yet measured
The Conclusion says the paper solves fibre-signal propagation through order c^-3 and derives one-way and two-way time- and frequency-transfer formulas. But Appendix A.5 says the one-way frequency-transfer formula (16), which uses the propagation-time derivative, is obtained through order c^-2; Section 4 estimates the c^-3 term rather than including it. The claimed c^-3 coverage therefore overstates the one-way frequency calculation. (LLM, conf=0.86)
plain- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: unclear — It is unclear whether the paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Partly supported
The cited sources support only part of this claim — read each source’s verdict below.
In the paper
“Indeed, coordinate time synchronization can only be theoretically realized in approximation schemes, e.g. postNewtonian approximation as reviewed in [26] for GPS.”
What the sources say
- Partly supportedcites [26] [26] N. Ashby. Relativity in the Global Positioning System. Living Reviews in Relativity , 6:1, 2003. - sourceExperimental — accuracy not yet measured
In “The Realization of Coordinate Time” (page unavailable), Ashby uses an approximate solution of the field equations as the basis for GPS coordinate-time synchronization. The paper does not establish that synchronization can *only* be theoretically realized through approximation schemes, and the cited passages do not identify the scheme as post-Newtonian. (LLM, conf=0.84)
plain- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: unclear — It is unclear whether the paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Partly supported
The cited sources support only part of this claim — read each source’s verdict below.
In the paper
“Within this project, a proof-of-principle experiment of chronometric geodesy was done by comparing two optical clocks separated by a height difference of around 1000 m, using an optical fibre link [61].”
What the sources say
- Partly supportedcites [61] [61] Jacopo Grotti, Silvio Koller, Stefan Vogt, Sebastian H¨ afner, Uwe Sterr, Christian Lisdat, Heiner Denker, Christian Voigt, Ludger Timmen, Antoine Rolland, Fred N. Baynes, Helen S. Margolis, Michel Zampaolo, Pierre Thoumany, Marco Pizzocaro, Benjamin Rauf, Filippo Bregolin, Anna Tampellini, Piero Barbieri, Massimo Zucco, Giovanni A. Costanzo, Cecilia Clivati, Filippo Levi, and Davide Calonico. Geodesy and metrology with a transportable optical clock. arXiv:1705.04089 [physics] , 2017. - sourceExperimental — accuracy not yet measured
The paper reports a chronometric-levelling demonstration between sites about 1000 m apart, connected by an optical fibre link (pp. 1–2), and acknowledges funding from the European ITOC project (Acknowledgements, p. 6). But the remote measurement compared the transportable optical Sr clock with a Cs fountain clock; the comparison between the two optical clocks, Sr and Yb, was performed locally after the Sr clock was moved to INRIM (Fig. 1 caption, p. 2; p. 4). (LLM, conf=0.90)
plain- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: unclear — It is unclear whether the paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Partly supported
The cited sources support only part of this claim — read each source’s verdict below.
In the paper
“SFS can have a relative accuracy down to the range 10 -17 - 10 -18 [75, 76, 77].”
What the sources say
- Partly supportedcites [75] [75] C. Lisdat, G. Grosche, N. Quintin, C. Shi, S. M. F. Raupach, C. Grebing, D. Nicolodi, F. Stefani, A. Al-Masoudi, S. D¨ orscher, S. H¨ afner, J.-L. Robyr, N. Chiodo, S. Bilicki, E. Bookjans, A. Koczwara, S. Koke, A. Kuhl, F. Wiotte, F. Meynadier, E. Camisard, M. Abgrall, M. Lours, T. Legero, H. Schnatz, U. Sterr, H. Denker, C. Chardonnet, Y. Le Coq, G. Santarelli, A. Amy-Klein, R. Le Targat, J. Lodewyck, O. Lopez, and P.-E. Pottie. A clock network for geodesy and fundamental science. Nature Communications , 7:12443, 2016. - sourceExperimental — accuracy not yet measured
The Results (Optical clock performance; page unavailable) give fractional uncertainties of 4 × 10⁻¹⁷ and 2 × 10⁻¹⁷ for the two strontium clocks, supporting the 10⁻¹⁷ part of the claim. The Discussion (page unavailable) mentions a previous clock comparison with 5 × 10⁻¹⁸ uncertainty, but that is a comparison uncertainty, not a stated relative accuracy of an individual secondary frequency standard. (LLM, conf=0.84)
- Partly supportedcites [76] [76] M. Schioppo, R. C. Brown, W. F. McGrew, N. Hinkley, R. J. Fasano, K. Beloy, T. H. Yoon, G. Milani, D. Nicolodi, J. A. Sherman, N. B. - Phillips, C. W. Oates, and A. D. Ludlow. Ultrastable optical clock with two cold-atom ensembles. Nat Photon , 11(1):48-52, 2017. - sourceExperimental — accuracy not yet measured
The optical-clock discussion (page unavailable) reports stability at 6 × 10^-17 with averaging and an instability level of 1 × 10^-18 after a few thousand seconds. These figures support the stated numerical range for stability, but the paper does not establish relative accuracy in that range or identify the clocks as secondary frequency standards. (LLM, conf=0.82)
- Supportedcites [77] [77] N. Huntemann, C. Sanner, B. Lipphardt, Chr. Tamm, and E. Peik. Single-ion atomic clock with 3 × 10 -18 systematic uncertainty. Phys. Rev. Lett. , 116(6):063001, 2016. - source
The opening summary (p. 1) describes a single-ion optical frequency standard with a total systematic relative uncertainty of 3.2 × 10^-18. That demonstrates a frequency standard reaching the 10^-18 range claimed, although the paper calls it an optical rather than a secondary frequency standard. (LLM, conf=0.88)
plain- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: unclear — It is unclear whether the paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Partly supported
The cited sources support only part of this claim — read each source’s verdict below.
In the paper
“Nevertheless, to state an order of magnitude, considering a systematic variation in the sea level of order 2 mm/yr, different definitions of a reference surface for the gravity potential could yield differences in the redshift correction of the AFS of order 2 × 10 -18 in a decade, which is of the same order than the best current SFS accuracies [77, 76].”
What the sources say
- Supportedcites [77] [77] N. Huntemann, C. Sanner, B. Lipphardt, Chr. Tamm, and E. Peik. Single-ion atomic clock with 3 × 10 -18 systematic uncertainty. Phys. Rev. Lett. , 116(6):063001, 2016. - source
Split into 2 atoms — 2 confirmed, 0 partially supported, 0 disputed, 0 misattributed, 0 unverifiable. Expand the claim to see per-atom verdicts.
- Could not verifycites [76] [76] M. Schioppo, R. C. Brown, W. F. McGrew, N. Hinkley, R. J. Fasano, K. Beloy, T. H. Yoon, G. Milani, D. Nicolodi, J. A. Sherman, N. B. - Phillips, C. W. Oates, and A. D. Ludlow. Ultrastable optical clock with two cold-atom ensembles. Nat Photon , 11(1):48-52, 2017. - sourceExperimental — accuracy not yet measured
Split into 2 atoms — 0 confirmed, 0 partially supported, 0 disputed, 0 misattributed, 2 unverifiable. Expand the claim to see per-atom verdicts.
hedgedstates a possible cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: unclear — It is unclear whether the paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Supported
122 more claims · 14 with their cited sources checked
Create a free account to see all 235 claims and to verify the 18 references still open.
- Probably not a substantial claim. 52
- It may state two separate claims as one. 71
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
Rated major: it would touch a result — a value a result rests on, reported and recomputed p-values on opposite sides of the significance level, two passages that conflict with no sign which is right, or a cited work retracted before this paper was published.
In the paper
“for potential differences over larger distances of a few 100 km (i.e. typical distances between different metrology institutes), the statistical correlations of the quasigeoid values virtually vanish, which then leads to a standard deviation for the potential difference of 3.2 cm in terms of height, i.e. √ 2 times the figure given above for the absolute potential”
Reported 3.2 · recomputed 3.11127
Citations
Cites
Journal of Physics: Conference Series
(2013) · Journal of Physics Conference Series · doi:10.1088/issn.1742-6596 · Cited by 15,679
The development and evaluation of the Earth Gravitational Model 2008 (EGM2008)
Pavlis, N. K., Holmes, S. A., Kenyon, S. C., & Factor, J. K. (2012) · Journal of Geophysical Research: Solid Earth · doi:10.1029/2011jb008916 · Cited by 2,641 · cited 2×
“velengths is still quite signicant with values at the level of several decimetres, e.g., 0:94m for n= 90, 0:42m for n= 200, and 0:23m for n= 360. For the ultra-high degree geopotential model EGM2008 [144], which combines satellite and terrestrial data and is complete up to degree and order 2159, the omission error is…”
BackgroundMethod(2009) · Encyclopedia of Time: Science, Philosophy, Theology, & Culture · doi:10.4135/9781412963961.n455 · Cited by 2,421
Altamimi, Z., Rebischung, P., Métivier, L., & Collilieux, X. (2016) · Journal of Geophysical Research: Solid Earth · doi:10.1002/2016jb013098 · Cited by 1,427 · cited 1×
“pendent of the interstation distance. For instance, the station coordinates provided by the International GNSS Service (IGS) or the IERS (e.g. ITRF2008) reach vertical accuracies of about 5{10mm (cf. [159, 160, 161]). The uncertainty of the quasigeoid heights (height anomalies) is discussed in the previous subsection,…”
MethodITRF2008: an improved solution of the international terrestrial reference frame
Altamimi, Z., Collilieux, X., & Métivier, L. (2011) · Journal of Geodesy · doi:10.1007/s00190-011-0444-4 · Cited by 1,181 · cited 1×
“pendent of the interstation distance. For instance, the station coordinates provided by the International GNSS Service (IGS) or the IERS (e.g. ITRF2008) reach vertical accuracies of about 5{10mm (cf. [159, 160, 161]). The uncertainty of the quasigeoid heights (height anomalies) is discussed in the previous subsection,…”
MethodHeiskanen, W. A., & Moritz, H. (1967) · Bulletin géodésique · doi:10.1007/bf02525647 · Cited by 1,144
(2014) · Dictionary Geotechnical Engineering/Wörterbuch GeoTechnik · doi:10.1007/978-3-642-41714-6_10674 · Cited by 1,137
Chou, C. W., Hume, D. B., Rosenband, T., & Wineland, D. J. (2010) · Science · doi:10.1126/science.1192720 · Cited by 828 · cited 1×
“The potentiality of the new generation of atomic clocks has been shown in [64], based on optical transitions, to measure heights with a resolution of around 30 cm.”
BackgroundPound, R. V., & Rebka, G. A. (1960) · Physical Review Letters · doi:10.1103/physrevlett.4.337 · Cited by 804 · cited 1×
“It is only in 1959 that the gravitational redshift is confirmed in a lab experiment by Pound, Rebka and Snider [1, 2, 3, 4].”
BackgroundGeodetic Reference System 1980
Moritz, H. (1992) · Bulletin G�od�sique · doi:10.1007/bf00989270 · Cited by 740 · cited 1×
“850 m 2 s−2, associated with the surface of the underlying GRS80 (Geodetic Reference System 1980; see [172]) level ellipsoid, is used, resulting in C(GNSS/geoid).”
Background
Research works printed but not linked: 12
- [22] C. Møller. Theory of Relativity . Oxford University Press, Oxford, 2 edition edition, 1976. -
- [57] A. Bjerhammar. Discrete approaches to the solution of the boundary value problem in physical geodesy. Bolletino di geodesia e scienze affini , (2):185-241, 1975. -
- [68] B. Hofmann-Wellenhof and H. Moritz. Physical Geodesy . Springer Science & Business Media, 2006. -
- [121] J. L. Synge. Relativity: The General Theory . North-Holland Publishing Company, Amsterdam, y first edition edition edition, 1960. -
- [140] J. Ihde, R. Barzaghi, U. Marti, L. S` anchez, M. Sideris, H. Drewes, C. Foerste, T. Gruber, G. Liebsch, and G. Pail. Report of the ad-hoc group on an international height reference system (ihrs). In Reports 2011-2015 , number 39 in IAG Travaux, pages 549-557. 2015. -
- [141] Milan Burˇ sa, Jan Kouba, Muneendra Kumar, Achim M¨ uller, Karel Radˇ ej, Scott A. True, Viliam Vatrt, and Marie Vojt´ ıˇ skov´ a. Geoidal Geopotential and World Height System. Studia Geophysica et Geodaetica , 43(4):327-337, 1999. -
- [149] J. C. Ries. The scale of the terrestrial reference frame from VLBI and SLR, 2014. IERS Unified Analysis Workshop, Pasadena, CA, 27-28 June 2014. -
- [155] P. Rebischung, H. Duquenne, and F. Duquenne. The new French zeroorder levelling network - first global results and possible consequences for UELN, 2008. EUREF Symposium, Brussels, June 18-21, 2008. -
- [170] M. Greaves, R. Hipkin, C. Calvert, C. Fane, P. Rebischung, F. Duquenne, A. Harmel, A. Coulomb, and H. Duquenne. Connection of British and French levelling networks - Applications to UELN, 2007. EUREF Symposium, London, June 6-9, 2007. -
- [174] H. Denker. Hochaufl¨ osende regionale Schwerefeldbestimmung mit gravimetrischen und topographischen Daten . PhD thesis, Wiss. Arb. d. Fachr. Verm.wesen d. Univ. Hannover, Nr. 156, Hannover, 1988. -
- [175] H. Denker. Evaluation and improvement of the EGG97 quasigeoid model for Europe by GPS and leveling data. In M. Vermeer and - J. ´ Ad´ am, editors, Second Continental Workshop on the Geoid in Europe, Proceed., Rep. Finnish Geod. Inst., Masala , volume 98:4, pages 53-61, 1998. -
- [177] D. A. Smith. There is no such thing as 'The' EGM96 geoid: Subtle points on the use of a global geopotential model. Technical report, IGeS Bulletin No. 8, International Geoid Service, Milan, Italy, 1998. -
Cited by
Intercontinental comparison of optical atomic clocks through very long baseline interferometry
Pizzocaro, M., Sekido, M., Takefuji, K., Ujihara, H., Hachisu, H., Nemitz, N., Tsutsumi, M., Kondo, T., Kawai, E., Ichikawa, R., et al. (2021) · Nature Physics · doi:10.1038/s41567-020-01038-6 · Cited by 64
GENESIS: co-location of geodetic techniques in space
Delva, P., Altamimi, Z., Blazquez, A., Bloßfeld, M., Böhm, J., Bonnefond, P., Boy, J., Bruinsma, S., Bury, G., Chatzinikos, M., et al. (2023) · Earth Planets and Space · doi:10.1186/s40623-022-01752-w · Cited by 72
“This novel technique has reached an accuracy that allows the precise measurement of differences of the gravity potential exploiting the gravitational redshift (Müller et al., 2018; Delva et al., 2019).”
MethodSelf-citationA lab-based test of the gravitational redshift with a miniature clock network
Zheng, X., Dolde, J., Cambria, M. C., Lim, H. M., & Kolkowitz, S. (2023) · Nature Communications · doi:10.1038/s41467-023-40629-8 · Cited by 47
The unit of time: Present and future directions
Bize, S. (2019) · Comptes Rendus. Physique · doi:10.1016/j.crhy.2019.02.002 · Cited by 47
“as sensors to determine gravitational potential differences for the purpose of geodesy 14 and Earth’s science. This method called chronometric geodesy was proposed several decades ago (see for example [180] and references therein). However, it is only now that progress in optical frequency standards and in optical freq…”
MethodImproved interspecies optical clock comparisons through differential spectroscopy
Kim, M. E., McGrew, W. F., Nardelli, N. V., Clements, E., Hassan, Y. S., Zhang, X., Valencia, J. L., Leopardi, H., Hume, D. B., Fortier, T. M., et al. (2022) · Nature Physics · doi:10.1038/s41567-022-01794-7 · Cited by 43
Direct comparisons of European primary and secondary frequency standards via satellite techniques
Riedel, F., Al-Masoudi, A., Benkler, E., Dörscher, S., Gerginov, V, Grebing, C., Häfner, S., Huntemann, N., Lipphardt, B., Lisdat, C., et al. (2020) · Metrologia · doi:10.1088/1681-7575/ab6745 · Cited by 38
“CRefMk is the geopotential number for a specific nearby reference marker based on the geodetic GNSS/geoid approach [30,32], ∆H is the local height difference between the clock and a specific reference marker with ∆H = Hclock −HRefMk, g is the local acceleration due to gravity derived from an FG5-X absolute gravimeter…”
BackgroundSelf-citationExploring potential applications of optical lattice clocks in a plate subduction zone
Tanaka, Y., & Katori, H. (2021) · Journal of Geodesy · doi:10.1007/s00190-021-01548-y · Cited by 31
Using quantum optical sensors for determining the Earth’s gravity field from space
Müller, J., & Wu, H. (2020) · Journal of Geodesy · doi:10.1007/s00190-020-01401-8 · Cited by 32
Optical and Microwave Metrology at the 10−18 Level with an Er/Yb:glass Frequency Comb
Nardelli, N. V., Leopardi, H., Schibli, T. R., & Fortier, T. M. (2023) · Laser & Photonics Review · doi:10.1002/lpor.202200650 · Cited by 23
Shen, Z., Shen, W., Zhang, T., He, L., Cai, Z., Tian, X., & Zhang, P. (2021) · Advances in Space Research · doi:10.1016/j.asr.2021.07.004 · Cited by 15
Relativistic geoid: Gravity potential and relativistic effects
Philipp, D., Hackmann, E., Lämmerzahl, C., & Müller, J. (2020) · Physical review. D/Physical review. D. · doi:10.1103/physrevd.101.064032 · Cited by 16
Universal formalism for data sharing and processing in clock comparison networks
Lodewyck, J., Targat, R. L., Pottie, P.-É., Benkler, E., Koke, S., & Kronjäger, J. (2020) · Physical Review Research · doi:10.1103/physrevresearch.2.043269 · Cited by 13
“to the reduced frequency ratios ρ̃i,j , where Ci is the gravitational potential at the location of clock i, expressed in a common reference frame [25].”
BackgroundDetermination of the time-variable geopotential by means of orbiting clocks
Giuliani, S., Tapley, B. D., & Ries, J. (2024) · Journal of Geodesy · doi:10.1007/s00190-024-01868-9 · Cited by 9
Wu, Y., & Shen, W. (2021) · Advances in Space Research · doi:10.1016/j.asr.2021.05.005 · Cited by 10
On the feasibility of retrieving the temporal gravity field via improved optical clocks
Zheng, S., Zhou, H., Ma, Z., Guo, X., & Luo, Z. (2025) · Journal of Geodesy · doi:10.1007/s00190-024-01930-6 · Cited by 5
“Optical clocks are devices that utilize atomic transition frequencies within the optical range as frequency standards (Gellesch et al. 2020), enabling relativistic geodesy and chronometric geodesy (Delva et al. 2019).”
Geršl, J. (2023) · Astronomy and Astrophysics · doi:10.1051/0004-6361/202345994 · Cited by 2
“…at satellites with applications in fundamental science (Delva et al. 2017, 2018; Safronova et al. 2018; Beloy et al. 2021), geodesy (Müller et al. 2018; Mehlstäubler et al. 2018; Delva et al. 2019), and metrology (Fujieda et al. 2014; Hachisu et al. 2014; Riedel et al. 2020; Pizzocaro et al. 2021).”
BackgroundXiong, C., Liu, D., Wu, L., Bao, L., & Zhang, P. (2022) · Remote Sensing · doi:10.3390/rs14174141 · Cited by 3
Unifying the Nepal height system and China height system based on gravity frequency shift approach
Shanker, K. C., Shen, Z., & Shen, W. (2024) · Geodesy and Geodynamics · doi:10.1016/j.geog.2024.04.005 · Cited by 2
Comparing Frequency Transfer via GNSS and Fiber in a Common-Clock Configuration
Elmaghraby, A., Krawinkel, T., Schön, S., Kniggendorf, A., Kühl, A., Mukherjee, S., Kronjäger, J., & Piester, D. (2024) · Proceedings of the ... annual Precise Time and Time Interval (PTTI) Systems and Applications Meeting/Proceedings of a meeting - Precise Time and Time Interval (PTTI) Systems and Applications Meeting · doi:10.33012/2024.19592 · Cited by 1
Shabanloui, A., Wu, H., & Müller, J. (2023) · International Association of Geodesy symposia · doi:10.1007/1345_2023_220 · Cited by 1
Capture of Thulium Atoms into a Magneto-Optical Trap and Their Detection Using the 530-nm Transition
Provorchenko, D. I., Dvurechenskii, A. A., Bessmertnykh, B. A., Mishin, D., Трегубов, Д. О., Kolachevsky, N., & Golovizin, A. A. (2026) · Journal of Experimental and Theoretical Physics Letters · doi:10.1134/s0021364026601314 · Cited by 1
Elmaghraby, A., Krawinkel, T., Kersten, T., & Schön, S. (2026) · International Association of Geodesy symposia · doi:10.1007/1345_2026_382
Мареев, А. В., & Гиенко, Е. Г. (2025) · Geodesy and Cartography · doi:10.22389/0016-7126-2025-1024-10-12-20
Sanchez, L. A. (2023) · Encyclopedia of earth sciences series/Encyclopedia of earth sciences · doi:10.1007/978-3-319-02370-0_49-1
Towards a Transportable Yb Lattice Clock at SYRTE
Moreno, W., Rahmouni, F., Pointard, B., Pottie, P.-É., Delva, P., Lodewyck, J., Targat, R. L., González, J. R., Lalancette, M.-F., Lion, G., et al. (2022) · Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS) · doi:10.1109/eftf/ifcs54560.2022.9850674
Self-citationCambier, V. (2019) · theses.fr (ABES) · doi:10.70675/b79eb559z5f59z469cz99a6z5bc084c58e1b · Cited by 3
Metadata
- Authors
- Delva, P., Denker, H., & Lion, G.
- Affiliations
- Leibniz University Hannover (DE)
- Sorbonne Paris Cité (FR)
- Venue
- Fundamental Theories of Physics
- Publisher
- Springer International Publishing
- Published
- 2019
- Pages
- 25-85
- ISSN
- 0168-1222 (ISSN-L)
- 2365-6425
- OpenAlex
- W2799159265
- Cited by
- 28
- References
- 206
- Citations by year
- 2026: 3 · 2025: 2 · 2024: 3 · 2023: 7 · 2022: 3 · 2021: 3 · 2020: 5 · 2019: 2
- FWCI
- 18.88
- Type
- book chapter
- Language
- en
- Open access
- green
- arxiv.org
- Licence
- www.springer.com/tdm (tdm)
- Locations
- Fundamental theories of physics (publishedVersion)
- arXiv (Cornell University) (submittedVersion)
- HAL (submittedVersion)
- arXiv (Cornell University)
- Topics
- Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Advanced Frequency and Time Standards
- Physical Sciences › Physics and Astronomy › Astronomy and Astrophysics › Relativity and Gravitational Theory
- Physical Sciences › Earth and Planetary Sciences › Geophysics › Geophysics and Gravity Measurements
- Keywords
- atomic clock comparison, gravitational redshift, general relativity, geoid, physical geodesy, optical fiber links
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
The claim verdicts this report counts are experimental: their accuracy is not yet measured.
A language model drew the claims from the paper on 2026-10-10, under version 3 of the claim definition (model deepseek-v4.1-flash, prompt extract-v3).
A second model labelled each claim on 2026-10-10 (model jev-1.13-20260917, definition revision gold-guideline-v0.2).
Cited sources are checked with a language model’s help (gpt-6-sol).
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.