21 Tesla Fourier Transform Ion Cyclotron Resonance Mass Spectrometer: A National Resource for Ultrahigh Resolution Mass Analysis
The DOI matches its Crossref record; 38 of the 38 references it cites were found in a registry or an index.
Abstract
We describe the design and initial performance of the first 21 tesla Fourier transform ion cyclotron resonance (FT-ICR) mass spectrometer. The 21 tesla magnet is the highest field superconducting magnet ever used for FT-ICR and features high spatial homogeneity, high temporal stability, and negligible liquid helium consumption. The instrument includes a commercial dual linear quadrupole trap front end that features high sensitivity, precise control of trapped ion number, and collisional and electron transfer dissociation. A third linear quadrupole trap offers high ion capacity and ejection efficiency, and rf quadrupole ion injection optics deliver ions to a novel dynamically harmonized ICR cell. Mass resolving power of 150,000 (m/Δm(50%)) is achieved for bovine serum albumin (66 kDa) for a 0.38 s detection period, and greater than 2,000,000 resolving power is achieved for a 12 s detection period. Externally calibrated broadband mass measurement accuracy is typically less than 150 ppb rms, with resolving power greater than 300,000 at m/z 400 for a 0.76 s detection period. Combined analysis of electron transfer and collisional dissociation spectra results in 68% sequence coverage for carbonic anhydrase. The instrument is part of the NSF High-Field FT-ICR User Facility and is available free of charge to qualified users.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Citations
Cites
Introduction to Plasma Physics and Controlled Fusion
Chen, F. F. (1984) · Springer eBooks · doi:10.1007/978-1-4757-5595-4 · Cited by 3,279
Fourier transform ion cyclotron resonance mass spectrometry: A primer
Marshall, A. G., Hendrickson, C. L., & Jackson, G. S. (1998) · Mass Spectrometry Reviews · doi:10.1002/(sici)1098-2787(1998)17:1<1::aid-mas1>3.0.co;2-k · Cited by 1,990
Self-citationA two-dimensional quadrupole ion trap mass spectrometer
Schwartz, J. C., Senko, M. W., & Syka, J. E. P. (2002) · Journal of the American Society for Mass Spectrometry · doi:10.1016/s1044-0305(02)00384-7 · Cited by 796
Micro-electrospray mass spectrometry: Ultra-high-sensitivity analysis of peptides and proteins
Emmett, M. R., & Caprioli, R. M. (1994) · Journal of the American Society for Mass Spectrometry · doi:10.1016/1044-0305(94)85001-1 · Cited by 510
Automated reduction and interpretation of
Horn, D. M., Zubarev, R. A., & McLafferty, F. W. (2000) · Journal of the American Society for Mass Spectrometry · doi:10.1016/s1044-0305(99)00157-9 · Cited by 507
Space charge effects in Fourier transform mass spectrometry. II. Mass calibration
Ledford, E. B., Rempel, D. L., & Gross, M. L. (1984) · Analytical Chemistry · doi:10.1021/ac00278a027 · Cited by 468
Senko, M. W., Hendrickson, C. L., Emmett, M. R., Shi, S. D. H., & Marshall, A. G. (1997) · Journal of the American Society for Mass Spectrometry · doi:10.1016/s1044-0305(97)00126-8 · Cited by 462
Self-citationCaravatti, P., & Allemann, M. (1991) · Organic Mass Spectrometry · doi:10.1002/oms.1210260527 · Cited by 385
Complete Protein Characterization Using Top-Down Mass Spectrometry and Ultraviolet Photodissociation
Shaw, J. B., Li, W., Holden, D. D., Zhang, Y., Griep-Raming, J., Fellers, R. T., Early, B. P., Thomas, P. M., Kelleher, N. L., & Brodbelt, J. S. (2013) · Journal of the American Chemical Society · doi:10.1021/ja4029654 · Cited by 371
Activated Ion Electron Capture Dissociation for Mass Spectral Sequencing of Larger (42 kDa) Proteins
Horn, D. M., Ge, Y., & McLafferty, F. W. (2000) · Analytical Chemistry · doi:10.1021/ac000494i · Cited by 333
Research works printed but not linked: 3
- Hendrickson, C.L., Beu, S.C., Blakney, G.T., Kaiser, N.K., McIntosh, D.G., Quinn, J.P., Marshall, A.G.: Optimized cell geometry for Fourier transform ion cyclotron resonance mass spectrometry. Proceedings of the 57th ASMS Conference on Mass Spectrometry and Allied Topics, May 31-June 4, Philadelphia, PA (2009)
- Chen, T., Kaiser, N.K., Weisbrod, C.R., Beu, S.C., Blakney, G.T., Quinn, J.P., McIntosh, D.G., Williams, V., Hendrickson, C.L., Marshall, A.G.: Simulation, construction and experimental characterization of a modified dynamically harmonized FT-ICR cell. Proceedings of the 62nd ASMS Conference on Mass Spectrometry and Allied Topics, June 15-19, Baltimore, MD (2014)
- Fellers RT, 2015, Proteomics, 00, 1
Cited by
High-Resolution Native Mass Spectrometry
Tamara, S., den Boer, M. A., & Heck, A. J. R. (2022) · Chemical Reviews · doi:10.1021/acs.chemrev.1c00212 · Cited by 511
21 Tesla FT-ICR Mass Spectrometer for Ultrahigh-Resolution Analysis of Complex Organic Mixtures
Smith, D. F., Podgorski, D. C., Rodgers, R. P., Blakney, G. T., & Hendrickson, C. L. (2018) · Analytical Chemistry · doi:10.1021/acs.analchem.7b04159 · Cited by 348
Self-citationA new conceptual framework for the transformation of groundwater dissolved organic matter
McDonough, L. K., Andersen, M. S., Behnke, M. I., Rutlidge, H., Oudone, P., Meredith, K., O’Carroll, D. M., Santos, I. R., Marjo, C. E., Spencer, R. G. M., et al. (2022) · Nature Communications · doi:10.1038/s41467-022-29711-9 · Cited by 284
Tolić, N., Liu, Y., Liyu, A., Shen, Y., Tfaily, M. M., Kujawinski, E. B., Longnecker, K., Kuo, L.-J., Robinson, E. W., Paša-Tolić, L., et al. (2017) · Analytical Chemistry · doi:10.1021/acs.analchem.7b03318 · Cited by 261
Phosphoproteomics in the Age of Rapid and Deep Proteome Profiling
Riley, N. M., & Coon, J. J. (2016) · Analytical Chemistry · doi:10.1021/acs.analchem.5b04123 · Cited by 265
Mass spectrometry-based proteomics as an emerging tool in clinical laboratories
Birhanu, A. G. (2023) · Clinical Proteomics · doi:10.1186/s12014-023-09424-x · Cited by 220
The Role of Electron Transfer Dissociation in Modern Proteomics
Riley, N. M., & Coon, J. J. (2018) · Analytical Chemistry · doi:10.1021/acs.analchem.7b04810 · Cited by 180
Mobilization of aged and biolabile soil carbon by tropical deforestation
Drake, T. W., Van Oost, K., Barthel, M., Bauters, M., Hoyt, A. M., Podgorski, D. C., Six, J., Boeckx, P., Trumbore, S. E., Cizungu Ntaboba, L., et al. (2019) · Nature Geoscience · doi:10.1038/s41561-019-0384-9 · Cited by 162
Towards Higher Sensitivity of Mass Spectrometry: A Perspective From the Mass Analyzers
Li, C., Chu, S., Tan, S., Yin, X., Jiang, Y., Dai, X., Gong, X., Fang, X., & Tian, D. (2021) · Frontiers in Chemistry · doi:10.3389/fchem.2021.813359 · Cited by 196
“The dual-cell LIT delivers more ions to the ICR cell through multiple filling, which provides high ion capacity and ejection efficiency (Hendrickson et al., 2015). Weisbrod et al. (2017) equipped a multipole storage device (MSD) in a hybrid system of dual-cell LIT and customized FT-ICR.”
BackgroundInfluentialThe Blood Proteoform Atlas: A reference map of proteoforms in human hematopoietic cells
Melani, R. D., Gerbasi, V. R., Anderson, L. C., Sikora, J. W., Toby, T. K., Hutton, J. E., Butcher, D. S., Negrão, F., Seckler, H. S., Srzentić, K., et al. (2022) · Science · doi:10.1126/science.aaz5284 · Cited by 140
Self-citationBowman, A. P., Blakney, G. T., Hendrickson, C. L., Ellis, S. R., Heeren, R. M. A., & Smith, D. F. (2020) · Analytical Chemistry · doi:10.1021/acs.analchem.9b04768 · Cited by 135
Self-citationMcDonough, L. K., O’Carroll, D. M., Meredith, K., Andersen, M. S., Brügger, C., Huang, H., Rutlidge, H., Behnke, M. I., Spencer, R. G. M., Mckenna, A. M., et al. (2019) · Water Research · doi:10.1016/j.watres.2019.115201 · Cited by 125
Extreme isomeric complexity of dissolved organic matter found across aquatic environments
Hawkes, J. A., Patriarca, C., Sjöberg, P. J. R., Tranvik, L. J., & Bergquist, J. (2018) · Limnology and Oceanography Letters · doi:10.1002/lol2.10064 · Cited by 117
Shaw, J. B., Lin, T.-Y., Leach, F. E., Tolmachev, A. V., Tolić, N., Robinson, E. W., Koppenaal, D. W., & Paša-Tolić, L. (2016) · Journal of the American Society for Mass Spectrometry · doi:10.1007/s13361-016-1507-9 · Cited by 116
Zhang, J., Mckenna, A. M., & Zhu, M. (2021) · Environmental Science & Technology · doi:10.1021/acs.est.1c01283 · Cited by 112
Recent Advances in Petroleum Analysis by Mass Spectrometry
Niyonsaba, E., Manheim, J., Yerabolu, R., & Kenttämaa, H. I. (2018) · Analytical Chemistry · doi:10.1021/acs.analchem.8b05258 · Cited by 102
Clinical importance of high-mannose, fucosylated, and complex N-glycans in breast cancer metastasis
Ščupáková, K., Adelaja, O. T., Balluff, B., Ayyappan, V., Tressler, C. M., Jenkinson, N. M., Claes, B. S. R., Bowman, A. P., Cimino‐Mathews, A., White, M. J., et al. (2021) · JCI Insight · doi:10.1172/jci.insight.146945 · Cited by 111
“21 also acquired high mass resolution MALDI-Fourier transform ion cyclotron resonance (FTICR) imaging data of a representative TMA (case 3, see Table 1) using a custom-designed 21T FTICR instrument (48) build around Velos Pro linear ion trap (Thermo Scientific, San Jose, USA) with MALDI imaging source (Spectroglyph LL…”
Chacón-Patiño, M. L., Smith, D. F., Hendrickson, C. L., Marshall, A. G., & Rodgers, R. P. (2020) · Energy & Fuels · doi:10.1021/acs.energyfuels.9b04288 · Cited by 108
Self-citationTextor, S. R., Wickland, K. P., Podgorski, D. C., Johnston, S. E., & Spencer, R. G. M. (2019) · Frontiers in Earth Science · doi:10.3389/feart.2019.00275 · Cited by 109
Behnke, M. I., McClelland, J. W., Tank, S. E., Kellerman, A. M., Holmes, R. M., Haghipour, N., Eglinton, T. I., Raymond, P. A., Suslova, A., Zhulidov, A. V., et al. (2021) · Global Biogeochemical Cycles · doi:10.1029/2020gb006871 · Cited by 100
“Extracts were stored at −20°C until analysis on a 21 T FT-ICR MS at the National High Magnetic Field Laboratory in Tallahassee, Florida (Hendrickson et al., 2015; D. F. Smith, Podgorski, et al., 2018) with negative electrospray ionization.”
BackgroundAnderson, L. C., DeHart, C. J., Kaiser, N. K., Fellers, R. T., Smith, D. F., Greer, J. B., LeDuc, R. D., Blakney, G. T., Thomas, P. M., Kelleher, N. L., et al. (2017) · Journal of Proteome Research · doi:10.1021/acs.jproteome.6b00696 · Cited by 94
Self-citationIdentifying the Molecular Signatures of Agricultural Expansion in Amazonian Headwater Streams
Spencer, R. G. M., Kellerman, A. M., Podgorski, D. C., Macedo, M. N., Jankowski, K. J., Nunes, D., & Neill, C. (2019) · Journal of Geophysical Research Biogeosciences · doi:10.1029/2018jg004910 · Cited by 98
“…(Riskin et al., 2017), leading to a host of shifting biogeochemically pathways for the fate of this material, as there are clear ramifications for physico‐ chemical processes including sorption and photochemical degradation of DOM (Aufdenkampe et al., 2001; Hernes et al., 2013; Lu et al., 2013).”
BackgroundHigh fire-derived nitrogen deposition on central African forests
Bauters, M., Drake, T. W., Verbeeck, H., Bodé, S., Hervé-Fernández, P., Zito, P., Podgorski, D. C., Boyemba, F., Makelele, I., Cizungu Ntaboba, L., et al. (2018) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1714597115 · Cited by 92
Current Challenges and Recent Developments in Mass Spectrometry–Based Metabolomics
Collins, S. L., Koo, I., Peters, J. M., Smith, P. B. W., & Patterson, A. D. (2021) · Annual Review of Analytical Chemistry · doi:10.1146/annurev-anchem-091620-015205 · Cited by 103
Dong, H., Cuthbertson, A. A., Plewa, M. J., Weisbrod, C. R., Mckenna, A. M., & Richardson, S. D. (2023) · Environmental Science & Technology · doi:10.1021/acs.est.3c00771 · Cited by 96
Self-citationTakemori, A., Butcher, D. S., Harman, V. M., Brownridge, P., Shima, K., Higo, D., Ishizaki, J., Hasegawa, H., Suzuki, J., Yamashita, M., et al. (2020) · Journal of Proteome Research · doi:10.1021/acs.jproteome.0c00303 · Cited by 90
Kooijman, P. C., Nagornov, K. O., Kozhinov, A. N., Kilgour, D. P. A., Tsybin, Y. O., Heeren, R. M. A., & Ellis, S. R. (2019) · Scientific Reports · doi:10.1038/s41598-018-36957-1 · Cited by 88
Young, R. B., Pica, N. E., Sharifan, H., Chen, H., Roth, H. K., Blakney, G. T., Borch, T., Higgins, C. P., Kornuc, J. J., McKenna, A. M., et al. (2022) · Environmental Science & Technology · doi:10.1021/acs.est.1c08143 · Cited by 85
Self-citationSurface-induced Dissociation Mass Spectrometry as a Structural Biology Tool
Snyder, D. T., Harvey, S. R., & Wysocki, V. H. (2021) · Chemical Reviews · doi:10.1021/acs.chemrev.1c00309 · Cited by 93
Instrumentation at the Leading Edge of Proteomics
Peters-Clarke, T. M., Coon, J. J., & Riley, N. M. (2024) · Analytical Chemistry · doi:10.1021/acs.analchem.3c04497 · Cited by 96
McDonough, L. K., Rutlidge, H., O’Carroll, D. M., Andersen, M. S., Meredith, K., Behnke, M. I., Spencer, R. G. M., Mckenna, A. M., Marjo, C. E., Oudone, P., et al. (2020) · Geochimica et Cosmochimica Acta · doi:10.1016/j.gca.2020.01.022 · Cited by 79
Johnston, S. E., Striegl, R. G., Bogard, M. J., Dornblaser, M., Butman, D., Kellerman, A. M., Wickland, K. P., Podgorski, D. C., & Spencer, R. G. M. (2020) · Limnology and Oceanography · doi:10.1002/lno.11417 · Cited by 83
“Extracts were analyzed on an FT-ICR MS equipped with a 21T superconducting magnet at the National High Magnetic Field Laboratory (Tallahassee, FL, U.S.A.) (Hendrickson et al. 2015; Smith et al. 2018).”
MethodPlastic formulation is an emerging control of its photochemical fate in the ocean
Walsh, A. N., Reddy, C. M., Niles, S. F., McKenna, A. M., Hansel, C. M., & Ward, C. P. (2021) · Environmental Science & Technology · doi:10.1021/acs.est.1c02272 · Cited by 76
Top-down proteomics: Where we are, where we are going?
Fornelli, L., Toby, T. K., Schachner, L. F., Doubleday, P. F., Srzentić, K., DeHart, C. J., & Kelleher, N. L. (2017) · Journal of Proteomics · doi:10.1016/j.jprot.2017.02.002 · Cited by 77
“Solutions to extend the MW range of proteoforms identified during denaturing top-down experiments based on Fourier-transform mass spectrometry include the use of new generation instruments such as the 21T FT-ICR mass spectrometers,[7,8] or novel data ACCEPTED MANUSCRIPT”
MethodRodgers, R. P., Mapolelo, M. M., Robbins, W. K., Chacón-Patiño, M. L., Putman, J. C., Niles, S. F., Rowland, S. M., & Marshall, A. G. (2019) · Faraday Discussions · doi:10.1039/c9fd00005d · Cited by 67
Self-citationFT‐ICR‐MS‐based metabolomics: A deep dive into plant metabolism
Maia, M., Figueiredo, A., CORDEIRO, C. A., & Silva, M. S. (2021) · Mass Spectrometry Reviews · doi:10.1002/mas.21731 · Cited by 78
Shi, Q., Zhang, Y., Chung, K. H., Zhao, S., & Xu, C. (2021) · Energy & Fuels · doi:10.1021/acs.energyfuels.1c01671 · Cited by 64
Benigni, P., & Fernandez-Lima, F. A. (2016) · Analytical Chemistry · doi:10.1021/acs.analchem.6b01946 · Cited by 68
Natural organic matter composition determines the molecular nature of silver nanomaterial-NOM corona
Baalousha, M., Afshinnia, K., & Guo, L. (2018) · Environmental Science Nano · doi:10.1039/c8en00018b · Cited by 62
Liu, R., Xia, S., & Li, H. (2022) · Mass Spectrometry Reviews · doi:10.1002/mas.21793 · Cited by 66
Papanastasiou, D. K., Kounadis, D., Lekkas, A., Orfanopoulos, I., Mpozatzidis, A., Smyrnakis, A., Panagiotopoulos, E., Kosmopoulou, M., Reinhardt-Szyba, M., Fort, K. L., et al. (2022) · Journal of the American Society for Mass Spectrometry · doi:10.1021/jasms.2c00214 · Cited by 66
Wologo, E., Shakil, S., Zolkos, S., Textor, S. R., Ewing, S. A., Klassen, J. K., Spencer, R. G. M., Podgorski, D. C., Tank, S. E., Baker, M. A., et al. (2020) · Global Biogeochemical Cycles · doi:10.1029/2020gb006719 · Cited by 64
“We selected a subset of samples for analysis of DOM chemical composition via ultrahigh resolution mass spectrometry with a 21 T FT‐ICR MS (Hendrickson et al., 2015; Smith et al., 2018).”
Molecular Signatures of Glacial Dissolved Organic Matter From Svalbard and Greenland
Kellerman, A. M., Vonk, J. E., McColaugh, S., Podgorski, D. C., van Winden, E., Hawkings, J. R., Johnston, S. E., Humayun, M., & Spencer, R. G. M. (2021) · Global Biogeochemical Cycles · doi:10.1029/2020gb006709 · Cited by 57
Advances in high‐resolution mass spectrometry techniques for analysis of high mass‐to‐charge ions
Lai, Y., & Wang, Y. (2022) · Mass Spectrometry Reviews · doi:10.1002/mas.21790 · Cited by 64
He, L., Anderson, L. C., Barnidge, D. R., Murray, D. L., Hendrickson, C. L., & Marshall, A. G. (2017) · Journal of the American Society for Mass Spectrometry · doi:10.1007/s13361-017-1602-6 · Cited by 55
Self-citationBahureksa, W. A., Borch, T., Young, R. B., Weisbrod, C. R., Blakney, G. T., & Mckenna, A. M. (2022) · Analytical Chemistry · doi:10.1021/acs.analchem.2c02377 · Cited by 53
Self-citationSanders, J. D., Mullen, C., Watts, E., Holden, D. D., Syka, J. E. P., Schwartz, J. C., & Brodbelt, J. S. (2019) · Analytical Chemistry · doi:10.1021/acs.analchem.9b04026 · Cited by 57
Stopka, S. A., Samarah, L. Z., Shaw, J., Liyu, A. V., Veličković, D., Agtuca, B. J., Kukolj, C., Koppenaal, D., Stacey, G. S., Paša‐Tolić, L., et al. (2019) · Analytical Chemistry · doi:10.1021/acs.analchem.8b05084 · Cited by 58
The emerging interface of mass spectrometry with materials
Chakraborty, P., & Pradeep, T. (2019) · NPG Asia Materials · doi:10.1038/s41427-019-0149-3 · Cited by 53
Vaughn, D., Kellerman, A. M., Wickland, K. P., Striegl, R. G., Podgorski, D. C., Hawkings, J. R., Nienhuis, J. H., Dornblaser, M., Stets, E. G., & Spencer, R. G. M. (2021) · Biogeochemistry · doi:10.1007/s10533-021-00852-1 · Cited by 58
IsoSpec: Hyperfast Fine Structure Calculator
Łącki, M. K., Startek, M. P., Valkenborg, D., & Gambin, A. (2017) · Analytical Chemistry · doi:10.1021/acs.analchem.6b01459 · Cited by 50
Weisbrod, C. R., Kaiser, N. K., Syka, J. E. P., Early, L., Mullen, C., Dunyach, J.-J., English, A. M., Anderson, L. C., Blakney, G. T., Shabanowitz, J., et al. (2017) · Journal of the American Society for Mass Spectrometry · doi:10.1007/s13361-017-1702-3 · Cited by 49
“Thus, intact protein analysis continues to advance with the development of higher performance mass spectrometers [7] and new/versatile ion activation approaches [8–14].”
Self-citationHuang, X. F., Liu, H., Lü, D., Lin, Y., Liu, J., Liu, Q. S., Nie, Z., & Jiang, G. (2021) · Chemical Society Reviews · doi:10.1039/d0cs00714e · Cited by 51
Land‐use controls on carbon biogeochemistry in lowland streams of the Congo Basin
Drake, T. W., Podgorski, D. C., Dinga, B. J., Chanton, J. P., Six, J., & Spencer, R. G. M. (2020) · Global Change Biology · doi:10.1111/gcb.14889 · Cited by 49
“After filtration, water samples were immediately frozen in the dark and stored until transportation to Florida State University for analysis.”
MethodInfluentialHu, Z., Mckenna, A. M., Wen, K., Zhang, B., Mao, H., Goual, L., Feng, X., & Zhu, M. (2024) · Environmental Science & Technology · doi:10.1021/acs.est.3c08123 · Cited by 44
Molecular-Level Characterization of Asphaltenes Isolated from Distillation Cuts
Mckenna, A. M., Chacón-Patiño, M. L., Weisbrod, C. R., Blakney, G. T., & Rodgers, R. P. (2019) · Energy & Fuels · doi:10.1021/acs.energyfuels.8b04219 · Cited by 44
Self-citationCampuzano, I. D. G., & Giles, K. (2019) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2019.115620 · Cited by 50
He, L., Rockwood, A. L., Agarwal, A. M., Anderson, L. C., Weisbrod, C. R., Hendrickson, C. L., & Marshall, A. G. (2019) · Clinical Chemistry · doi:10.1373/clinchem.2018.295766 · Cited by 43
Self-citationSama, S. G., Farenc, M., Barrère‐Mangote, C., Łobiński, R., Afonso, C., Bouyssière, B., & Giusti, P. (2018) · Energy & Fuels · doi:10.1021/acs.energyfuels.7b03218 · Cited by 43
Rogers, J. A., Galy, V., Kellerman, A. M., Chanton, J. P., Zimov, N., & Spencer, R. G. M. (2021) · Journal of Geophysical Research Biogeosciences · doi:10.1029/2020jg005977 · Cited by 46
Jiang, T., Hoover, M. E., Holt, M. V., Freitas, M. A., Marshall, A. G., & Young, N. L. (2018) · PROTEOMICS · doi:10.1002/pmic.201700442 · Cited by 43
Self-citationFornelli, L., & Toby, T. K. (2022) · Biochimica et Biophysica Acta (BBA) - Proteins and Proteomics · doi:10.1016/j.bbapap.2022.140758 · Cited by 42
Adams, L. M., DeHart, C. J., Drown, B., Anderson, L. C., Bocik, W., Boja, E. S., Hiltke, T., Hendrickson, C. L., Rodriguez, H., Caldwell, M. A., et al. (2022) · Journal of Biological Chemistry · doi:10.1016/j.jbc.2022.102768 · Cited by 37
Self-citationTucker, L. H., Hamm, G. R., Sargeant, R., Goodwin, R. J. A., Mackay, C. L., Campbell, C. J., & Clarke, D. J. (2019) · Analytical Chemistry · doi:10.1021/acs.analchem.9b00661 · Cited by 41
Roth, H. K., Borch, T., Young, R. B., Bahureksa, W. A., Blakney, G. T., Nelson, A. R., Wilkins, M. J., & Mckenna, A. M. (2022) · Analytical Chemistry · doi:10.1021/acs.analchem.1c05018 · Cited by 37
Self-citationComprehensive analysis of tropomyosin isoforms in skeletal muscles by top-down proteomics
Jin, Y., Peng, Y., Lin, Z., Chen, Y.-C., Wei, L., Hacker, T. A., Larsson, L., & Ge, Y. (2016) · Journal of Muscle Research and Cell Motility · doi:10.1007/s10974-016-9443-7 · Cited by 36
“Note that the LTQ/FT mass spectrometer used in this study is 8-year-old and there are now new generation of high-resolution high sensitivity FT-ICR and Orbitrap mass spectrometers available (Eliuk and Makarov 2015; Hendrickson et al. 2015; Kostyukevich et al. 2012; Xian et al. 2012).”
MethodWhisenhant, E. A., Zito, P. A., Podgorski, D. C., Mckenna, A. M., Redman, Z. C., & Tomco, P. L. (2022) · ACS ES&T Water · doi:10.1021/acsestwater.1c00494 · Cited by 36
Chacón-Patiño, M. L., Moulian, R., Barrère‐Mangote, C., Putman, J. C., Weisbrod, C. R., Blakney, G. T., Bouyssière, B., Rodgers, R. P., & Giusti, P. (2020) · Energy & Fuels · doi:10.1021/acs.energyfuels.0c03349 · Cited by 35
Self-citationWang, H., Lü, L., Chen, H., Mckenna, A. M., Lu, J., Jin, S., Zuo, Y., Rosario‐Ortiz, F. L., & Ren, Z. J. (2020) · Environmental Science & Technology · doi:10.1021/acs.est.9b06164 · Cited by 34
Fire Impacts on the Soil Metabolome and Organic Matter Biodegradability
VanderRoest, J. P., Fowler, J. A., Rhoades, C. C., Roth, H. K., Broeckling, C. D., Fegel, T. S., Mckenna, A. M., Bechtold, E. K., Boot, C. M., Wilkins, M. J., et al. (2024) · Environmental Science & Technology · doi:10.1021/acs.est.3c09797 · Cited by 36
Liberatore, H. K., Westerman, D. C., Allen, J. M., Plewa, M. J., Wagner, E. D., Mckenna, A. M., Weisbrod, C. R., McCord, J. P., Liberatore, R. J., Burnett, D. B., et al. (2020) · Environmental Science & Technology · doi:10.1021/acs.est.0c01997 · Cited by 33
Self-citationPutman, J. C., Moulian, R., Smith, D. F., Weisbrod, C. R., Chacón-Patiño, M. L., Corilo, Y., Blakney, G. T., Rumancik, L. E., Barrère‐Mangote, C., Rodgers, R. P., et al. (2020) · Energy & Fuels · doi:10.1021/acs.energyfuels.0c02158 · Cited by 32
Self-citationKurek, M. R., Wickland, K. P., Nichols, N. A., Mckenna, A. M., Anderson, S. M., Dornblaser, M., Koupaei‐Abyazani, N., Poulin, B. A., Bansal, S., Fellman, J. B., et al. (2024) · Global Biogeochemical Cycles · doi:10.1029/2023gb007917 · Cited by 37
“Methanolic extracts were analyzed on a custom‐built hybrid linear ion trap ultra‐high resolution FT‐ICR mass spectrometer equipped with a 21T superconducting solenoid magnet at the National High Magnetic Field Laboratory (Tallahassee, FL; Hendrickson et al., 2015).”
MethodThe isotope distribution: A rose with thorns
Claesen, J., Rockwood, A. L., Gorshkov, M. V., & Valkenborg, D. (2023) · Mass Spectrometry Reviews · doi:10.1002/mas.21820 · Cited by 36
Chacón-Patiño, M. L., Mase, C., Maillard, J. F., Barrère‐Mangote, C., Dayton, D. C., Afonso, C., Giusti, P., & Rodgers, R. P. (2023) · Energy & Fuels · doi:10.1021/acs.energyfuels.3c02599 · Cited by 38
Constraining dissolved organic matter sources and temporal variability in a model sub-Arctic lake
Johnston, S. E., Bogard, M. J., Rogers, J. A., Butman, D., Striegl, R. G., Dornblaser, M., & Spencer, R. G. M. (2019) · Biogeochemistry · doi:10.1007/s10533-019-00619-9 · Cited by 32
Recent technological developments for native mass spectrometry
Webb, I. K. (2022) · Biochimica et Biophysica Acta (BBA) - Proteins and Proteomics · doi:10.1016/j.bbapap.2021.140732 · Cited by 29
IsoSpec2: Ultrafast Fine Structure Calculator
Łącki, M. K., Valkenborg, D., & Startek, M. P. (2020) · Analytical Chemistry · doi:10.1021/acs.analchem.0c00959 · Cited by 29
In-Cell Labeling and Mass Spectrometry for Systems-Level Structural Biology
Chavez, J. D., Wippel, H. H., Tang, X., Keller, A., & Bruce, J. E. (2021) · Chemical Reviews · doi:10.1021/acs.chemrev.1c00223 · Cited by 29
Molecular Characterization of Heavy Petroleum by Mass Spectrometry and Related Techniques
Qian, K. (2021) · Energy & Fuels · doi:10.1021/acs.energyfuels.1c01783 · Cited by 29
Rowland, S. M., Smith, D. F., Blakney, G. T., Corilo, Y., Hendrickson, C. L., & Rodgers, R. P. (2021) · Analytical Chemistry · doi:10.1021/acs.analchem.1c01169 · Cited by 29
Self-citationFourier‐transform ion cyclotron resonance mass spectrometry for characterizing proteoforms
Tucholski, T., & Ge, Y. (2020) · Mass Spectrometry Reviews · doi:10.1002/mas.21653 · Cited by 30
Pih1p-Tah1p Puts a Lid on Hexameric AAA+ ATPases Rvb1/2p
Tian, S., Yu, G., He, H., Zhao, Y., Liu, P., Marshall, A. G., Demeler, B., Stagg, S. M., & Li, H. (2017) · Structure · doi:10.1016/j.str.2017.08.002 · Cited by 29
“The ionized eluate was directed to a custom-built Velso Pro (Thermo Scientific) 21 T FT-ICR mass spectrometer (Hendrickson et al., 2015).”
MethodSelf-citationChacón-Patiño, M. L., Rowland, S. M., & Rodgers, R. P. (2018) · ACS symposium series · doi:10.1021/bk-2018-1282.ch006 · Cited by 28
He, L., Anderson, L. C., Barnidge, D. R., Murray, D. L., Dasari, S., Dispenzieri, A. A., Hendrickson, C. L., & Marshall, A. G. (2019) · Analytical Chemistry · doi:10.1021/acs.analchem.8b03294 · Cited by 31
Self-citationMüller, M. A., Kompauer, M., Strupat, K., Heiles, S., & Spengler, B. (2020) · Journal of the American Society for Mass Spectrometry · doi:10.1021/jasms.0c00368 · Cited by 27
Ijaz, A., Kew, W., China, S., Schum, S., & Mazzoleni, L. R. (2022) · Analytical Chemistry · doi:10.1021/acs.analchem.2c00916 · Cited by 28
Advanced fundamentals in Fourier transform mass spectrometry
Tsybin, Y. O., Nagornov, K. O., & Kozhinov, A. N. (2019) · Elsevier eBooks · doi:10.1016/b978-0-12-814013-0.00005-3 · Cited by 31
Johnston, S. E., Carey, J. C., Kellerman, A. M., Podgorski, D. C., Gewirtzman, J., & Spencer, R. G. M. (2021) · Journal of Geophysical Research Biogeosciences · doi:10.1029/2020jg005988 · Cited by 29
“Solid phase extracts for FT-ICR MS were ionized with negative electrospray ionization and directly infused into a 21 T FT-ICR MS at a flow rate of 700 nL min−1 (Hendrickson et al., 2015; Smith et al., 2018).”
MethodGosset‐Erard, C., Aubriet, F., Leize‐Wagner, E., François, Y., & Chaimbault, P. (2023) · Talanta · doi:10.1016/j.talanta.2023.124324 · Cited by 35
Somogyi, Á., Thissen, R., Orthous‐Daunay, F., & Vuitton, V. (2016) · International Journal of Molecular Sciences · doi:10.3390/ijms17040439 · Cited by 27
“The ultrahigh resolution capability of Orbitrap (up to about 450,000, see Reference [36]) and ICR instruments (up to about 20,000,000 with a 21T magnet [37] and with the recently developed dynamically harmonized cell [38]) allow us:”
BackgroundShaw, J., Gorshkov, M. V., Wu, Q., & Paša‐Tolić, L. (2018) · Analytical Chemistry · doi:10.1021/acs.analchem.7b04606 · Cited by 26
Weisbrod, C. R., Anderson, L. C., Hendrickson, C. L., Schaffer, L. V., Shortreed, M. R., Smith, L. M., Shabanowitz, J., & Hunt, D. F. (2021) · Analytical Chemistry · doi:10.1021/acs.analchem.1c00847 · Cited by 28
Self-citationChemistry and Properties of Carbon Fiber Feedstocks from Bitumen Asphaltenes
Chacón-Patiño, M. L., Neumann, A., Rüger, C. P., Bomben, P. G., Friederici, L., Zimmermann, R., Frank, E., Kreis, P., Buchmeiser, M. R., & Gray, M. R. (2023) · Energy & Fuels · doi:10.1021/acs.energyfuels.2c04274 · Cited by 25
Grgic, A., Nagornov, K. O., Kozhinov, A. N., Michael, J. A., Anthony, I. G. M., Tsybin, Y. O., Heeren, R. M. A., & Ellis, S. R. (2023) · Analytical Chemistry · doi:10.1021/acs.analchem.3c04146 · Cited by 26
Fellman, J. B., Hood, E. W., Behnke, M. I., Welker, J. M., & Spencer, R. G. M. (2020) · Journal of Geophysical Research Biogeosciences · doi:10.1029/2020jg005804 · Cited by 24
“T FT‐ICR MS at the National High Magnetic Field Laboratory (Tallahassee, Florida; Hendrickson et al., 2015; Smith et al., 2018) with direct infusion negative electrospray ionization.”
BackgroundHydrology drives export and composition of carbon in a pristine tropical river
Drake, T. W., Barthel, M., Ekamba, C., Mpambi, D. M., Baumgartner, S., Botefa, C. I., Bauters, M., Kurek, M. R., Spencer, R. G. M., Mckenna, A. M., et al. (2023) · Limnology and Oceanography · doi:10.1002/lno.12436 · Cited by 27
“The molecular composition of acidic species from PPL-extracted DOM was determined by negative-ion micro-electrospray ionization coupled to a 21 Tesla FT-ICR-MS at the National Magnetic Field Laboratory at Florida State University, USA (Smith et al. 2018; Hendrickson et al. 2015).”
MethodHermes, A. L., Logan, M. N., Poulin, B. A., Mckenna, A. M., Dawson, T. E., Borch, T., & Hinckley, E. S. (2023) · Environmental Science & Technology · doi:10.1021/acs.est.3c01347 · Cited by 23
Developments in FTICR-MS and Its Potential for Body Fluid Signatures
Nicolardi, S., Bogdanov, B., Deelder, A. M., Palmblad, M., & van der Burgt, Y. E. M. (2015) · International Journal of Molecular Sciences · doi:10.3390/ijms161126012 · Cited by 21
“Since then, two FTICR-MS systems equipped with 21 tesla superconducting magnets have been installed at the National High Magnetic Field Laboratory (NHMFL) and at PNNL [57,58].”
MethodResultMckenna, A. M., Chen, H., Weisbrod, C. R., & Blakney, G. T. (2021) · Analytical Chemistry · doi:10.1021/acs.analchem.0c05230 · Cited by 20
Self-citation
Metadata
- Authors
- Hendrickson, C. L., Quinn, J. P., Kaiser, N. K., Smith, D. F., Blakney, G. T., Chen, T., Marshall, A. G., Weisbrod, C. R., & Beu, S. C.
- Affiliations
- Florida State University (US)
- S. C. Beu Consulting, 12449 Los Indios Trail, 78729, Austin, TX, USA
- ORCID
- Venue
- Journal of the American Society for Mass Spectrometry
- Publisher
- American Chemical Society (ACS)
- Published
- 2015-06-20
- Volume
- 26
- Issue
- 9
- Pages
- 1626-1632
- ISSN
- 1044-0305 (ISSN-L)
- OpenAlex
- W781416032
- Cited by
- 278
- References
- 37
- Citations by year
- 2026: 17 · 2025: 25 · 2024: 33 · 2023: 35 · 2022: 23 · 2021: 35 · 2020: 30 · 2019: 29 · 2018: 19 · 2017: 17 · 2016: 9 · 2015: 3
- FWCI
- 7.12
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.springer.com/tdm (tdm)
- Locations
- Journal of the American Society for Mass Spectrometry (publishedVersion)
- PubMed (publishedVersion)
- Funders
- National High Magnetic Field Laboratory
- Topics
- Physical Sciences › Chemistry › Spectroscopy › Mass Spectrometry Techniques and Applications
- Physical Sciences › Chemistry › Spectroscopy › Advanced Proteomics Techniques and Applications
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Molecular Biology › Metabolomics and Mass Spectrometry Studies
- Keywords
- Fourier transform ion cyclotron resonance, ultrahigh-resolution mass spectrometry, electron transfer dissociation, collision-induced dissociation, mass resolving power, mass accuracy, bovine serum albumin, carbonic anhydrase, protein sequencing
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.