Abstract
We describe the design and initial performance of the first 21 tesla Fourier transform ion cyclotron resonance (FT-ICR) mass spectrometer. The 21 tesla magnet is the highest field superconducting magnet ever used for FT-ICR and features high spatial homogeneity, high temporal stability, and negligible liquid helium consumption. The instrument includes a commercial dual linear quadrupole trap front end that features high sensitivity, precise control of trapped ion number, and collisional and electron transfer dissociation. A third linear quadrupole trap offers high ion capacity and ejection efficiency, and rf quadrupole ion injection optics deliver ions to a novel dynamically harmonized ICR cell. Mass resolving power of 150,000 (m/Δm(50%)) is achieved for bovine serum albumin (66 kDa) for a 0.38 s detection period, and greater than 2,000,000 resolving power is achieved for a 12 s detection period. Externally calibrated broadband mass measurement accuracy is typically less than 150 ppb rms, with resolving power greater than 300,000 at m/z 400 for a 0.76 s detection period. Combined analysis of electron transfer and collisional dissociation spectra results in 68% sequence coverage for carbonic anhydrase. The instrument is part of the NSF High-Field FT-ICR User Facility and is available free of charge to qualified users.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Citations
Cites
Introduction to Plasma Physics and Controlled Fusion
Chen, F. F. (1984) · Springer eBooks · doi:10.1007/978-1-4757-5595-4 · Cited by 3,279
Fourier transform ion cyclotron resonance mass spectrometry: A primer
Marshall, A. G., Hendrickson, C. L., & Jackson, G. S. (1998) · Mass Spectrometry Reviews · doi:10.1002/(sici)1098-2787(1998)17:1<1::aid-mas1>3.0.co;2-k · Cited by 1,990
Self-citationA two-dimensional quadrupole ion trap mass spectrometer
Schwartz, J. C., Senko, M. W., & Syka, J. E. P. (2002) · Journal of the American Society for Mass Spectrometry · doi:10.1016/s1044-0305(02)00384-7 · Cited by 796
Micro-electrospray mass spectrometry: Ultra-high-sensitivity analysis of peptides and proteins
Emmett, M. R., & Caprioli, R. M. (1994) · Journal of the American Society for Mass Spectrometry · doi:10.1016/1044-0305(94)85001-1 · Cited by 510
Automated reduction and interpretation of
Horn, D. M., Zubarev, R. A., & McLafferty, F. W. (2000) · Journal of the American Society for Mass Spectrometry · doi:10.1016/s1044-0305(99)00157-9 · Cited by 507
Space charge effects in Fourier transform mass spectrometry. II. Mass calibration
Ledford, E. B., Rempel, D. L., & Gross, M. L. (1984) · Analytical Chemistry · doi:10.1021/ac00278a027 · Cited by 468
Senko, M. W., Hendrickson, C. L., Emmett, M. R., Shi, S. D. H., & Marshall, A. G. (1997) · Journal of the American Society for Mass Spectrometry · doi:10.1016/s1044-0305(97)00126-8 · Cited by 462
Self-citationCaravatti, P., & Allemann, M. (1991) · Organic Mass Spectrometry · doi:10.1002/oms.1210260527 · Cited by 385
Complete Protein Characterization Using Top-Down Mass Spectrometry and Ultraviolet Photodissociation
Shaw, J. B., Li, W., Holden, D. D., Zhang, Y., Griep-Raming, J., Fellers, R. T., Early, B. P., Thomas, P. M., Kelleher, N. L., & Brodbelt, J. S. (2013) · Journal of the American Chemical Society · doi:10.1021/ja4029654 · Cited by 371
Activated Ion Electron Capture Dissociation for Mass Spectral Sequencing of Larger (42 kDa) Proteins
Horn, D. M., Ge, Y., & McLafferty, F. W. (2000) · Analytical Chemistry · doi:10.1021/ac000494i · Cited by 333
High Resolution Mass Spectrometry
Xian, F., Hendrickson, C. L., & Marshall, A. G. (2012) · Analytical Chemistry · doi:10.1021/ac203191t · Cited by 281
Self-citationPredator data station: A fast data acquisition system for advanced FT-ICR MS experiments
Blakney, G. T., Hendrickson, C. L., & Marshall, A. G. (2011) · International Journal of Mass Spectrometry · doi:10.1016/j.ijms.2011.03.009 · Cited by 261
Self-citationProSight Lite: Graphical software to analyze top‐down mass spectrometry data
Fellers, R. T., Greer, J. B., Early, B. P., Yu, X., LeDuc, R. D., Kelleher, N. L., & Thomas, P. M. (2015) · PROTEOMICS · doi:10.1002/pmic.201400313 · Cited by 247
Senko, M. W., Remes, P. M., Canterbury, J. D., Mathur, R., Song, Q., Eliuk, S. M., Mullen, C., Earley, L., Hardman, M., Blethrow, J. D., et al. (2013) · Analytical Chemistry · doi:10.1021/ac403115c · Cited by 243
Rodgers, R. P., & McKenna, A. M. (2011) · Analytical Chemistry · doi:10.1021/ac201080e · Cited by 213
High-Performance Mass Spectrometry: Fourier Transform Ion Cyclotron Resonance at 14.5 Tesla
Schaub, T. M., Hendrickson, C. L., Horning, S., Quinn, J. P., Senko, M. W., & Marshall, A. G. (2008) · Analytical Chemistry · doi:10.1021/ac800386h · Cited by 192
Self-citationAutomated Broadband Phase Correction of Fourier Transform Ion Cyclotron Resonance Mass Spectra
Xian, F., Hendrickson, C. L., Blakney, G. T., Beu, S. C., & Marshall, A. G. (2010) · Analytical Chemistry · doi:10.1021/ac101091w · Cited by 189
Self-citationWilcox, B. E., Hendrickson, C. L., & Marshall, A. G. (2002) · Journal of the American Society for Mass Spectrometry · doi:10.1016/s1044-0305(02)00622-0 · Cited by 165
Self-citationNikolaev, E. N., Boldin, I. A., Jertz, R., & Baykut, G. (2011) · Journal of the American Society for Mass Spectrometry · doi:10.1007/s13361-011-0125-9 · Cited by 164
Dual-Pressure Linear Ion Trap Mass Spectrometer Improving the Analysis of Complex Protein Mixtures
Pekar Second, T., Blethrow, J. D., Schwartz, J. C., Merrihew, G. E., MacCoss, M. J., Swaney, D. L., Russell, J. D., Coon, J. J., & Zabrouskov, V. (2009) · Analytical Chemistry · doi:10.1021/ac901278y · Cited by 161
Advantages of High Magnetic Field for Fourier Transform Ion Cyclotron Resonance Mass Spectrometry
Marshall, A. G., & Guan, S. (1996) · Rapid Communications in Mass Spectrometry · doi:10.1002/(sici)1097-0231(199611)10:14<1819::aid-rcm686>3.0.co;2-z · Cited by 144
Self-citationBoldin, I. A., & Nikolaev, E. N. (2011) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.4838 · Cited by 128
Unit resolution mass spectra of 112 kDa molecules with 3 Da accuracy
Kelleher, N. L., Senko, M. W., Siegel, M. M., & McLafferty, F. W. (1997) · Journal of the American Society for Mass Spectrometry · doi:10.1016/s1044-0305(97)00060-3 · Cited by 122
Cover Picture: Proteomics 7'15
(2015) · PROTEOMICS · doi:10.1002/pmic.201570050 · Cited by 121
Patrie, S. M., Charlebois, J. P., Whipple, D., Kelleher, N. L., Hendrickson, C. L., Quinn, J. P., Marshall, A. G., & Mukhopadhyay, B. (2004) · Journal of the American Society for Mass Spectrometry · doi:10.1016/j.jasms.2004.04.031 · Cited by 114
Self-citationThe first pilot project of the consortium for top‐down proteomics: A status report
Dang, X., Scotcher, J., Wu, S., Chu, R. K., Tolić, N., Ntai, I., Thomas, P. M., Fellers, R. T., Early, B. P., Zheng, Y., et al. (2014) · PROTEOMICS · doi:10.1002/pmic.201300438 · Cited by 100
Macroscopic variations of surface potentials of conductors
Camp, J. B., Darling, T. W., & Brown, R. E. (1991) · Journal of Applied Physics · doi:10.1063/1.347601 · Cited by 100
Space charge effects in Fourier Transform Mass Spectrometry. I. Electrons
Ledford, E. B., Rempel, D. L., & Gross, M. L. (1984) · International Journal of Mass Spectrometry and Ion Processes · doi:10.1016/0168-1176(84)85030-2 · Cited by 76
Serrano, J., Palmeira, C. M., Wallace, K. B., & Kuehl, D. W. (1996) · Rapid Communications in Mass Spectrometry · doi:10.1002/(sici)1097-0231(199611)10:14<1789::aid-rcm752>3.0.co;2-6 · Cited by 71
Self-citationValeja, S. G., Kaiser, N. K., Xian, F., Hendrickson, C. L., Rouse, J. C., & Marshall, A. G. (2011) · Analytical Chemistry · doi:10.1021/ac202429c · Cited by 67
Self-citationFront-End Electron Transfer Dissociation: A New Ionization Source
Earley, L., Anderson, L. C., Bai, D. L., Mullen, C., Syka, J. E. P., English, A. M., Dunyach, J.-J., Stafford, G. C., Shabanowitz, J., Hunt, D. F., et al. (2013) · Analytical Chemistry · doi:10.1021/ac401783f · Cited by 66
Kaiser, N. K., Mckenna, A. M., Savory, J., Hendrickson, C. L., & Marshall, A. G. (2012) · Analytical Chemistry · doi:10.1021/ac302678v · Cited by 58
Self-citationFT-ICR MS optimization for the analysis of intact proteins
Tolmachev, A. V., Robinson, E. W., Wu, S., Paša-Tolić, L., & Smith, R. D. (2009) · International Journal of Mass Spectrometry · doi:10.1016/j.ijms.2008.10.010 · Cited by 48
Controlled Ion Ejection from an External Trap for Extended m/z Range in FT-ICR Mass Spectrometry
Kaiser, N. K., Savory, J. J., & Hendrickson, C. L. (2014) · Journal of the American Society for Mass Spectrometry · doi:10.1007/s13361-014-0871-6 · Cited by 46
Self-citationChen, T., Beu, S. C., Kaiser, N. K., & Hendrickson, C. L. (2014) · Review of Scientific Instruments · doi:10.1063/1.4883179 · Cited by 35
Self-citationZhang, Q., Chen, J., Kuwajima, K., Zhang, H., Xian, F., Young, N. L., & Marshall, A. G. (2013) · Scientific Reports · doi:10.1038/srep01247 · Cited by 31
Self-citationWeisbrod, C. R., Hoopmann, M. R., Senko, M. W., & Bruce, J. E. (2013) · Journal of Proteomics · doi:10.1016/j.jprot.2013.04.009 · Cited by 29
Self-citationBeu, S. C., Hendrickson, C. L., & Marshall, A. G. (2011) · Journal of the American Society for Mass Spectrometry · doi:10.1007/s13361-010-0057-9 · Cited by 15
Self-citation
Research works printed but not linked: 3
- Hendrickson, C.L., Beu, S.C., Blakney, G.T., Kaiser, N.K., McIntosh, D.G., Quinn, J.P., Marshall, A.G.: Optimized cell geometry for Fourier transform ion cyclotron resonance mass spectrometry. Proceedings of the 57th ASMS Conference on Mass Spectrometry and Allied Topics, May 31-June 4, Philadelphia, PA (2009)
- Chen, T., Kaiser, N.K., Weisbrod, C.R., Beu, S.C., Blakney, G.T., Quinn, J.P., McIntosh, D.G., Williams, V., Hendrickson, C.L., Marshall, A.G.: Simulation, construction and experimental characterization of a modified dynamically harmonized FT-ICR cell. Proceedings of the 62nd ASMS Conference on Mass Spectrometry and Allied Topics, June 15-19, Baltimore, MD (2014)
- Fellers RT, 2015, Proteomics, 00, 1
Cited by
High-Resolution Native Mass Spectrometry
Tamara, S., den Boer, M. A., & Heck, A. J. R. (2022) · Chemical Reviews · doi:10.1021/acs.chemrev.1c00212 · Cited by 511
21 Tesla FT-ICR Mass Spectrometer for Ultrahigh-Resolution Analysis of Complex Organic Mixtures
Smith, D. F., Podgorski, D. C., Rodgers, R. P., Blakney, G. T., & Hendrickson, C. L. (2018) · Analytical Chemistry · doi:10.1021/acs.analchem.7b04159 · Cited by 348
Self-citationA new conceptual framework for the transformation of groundwater dissolved organic matter
McDonough, L. K., Andersen, M. S., Behnke, M. I., Rutlidge, H., Oudone, P., Meredith, K., O’Carroll, D. M., Santos, I. R., Marjo, C. E., Spencer, R. G. M., et al. (2022) · Nature Communications · doi:10.1038/s41467-022-29711-9 · Cited by 284
Tolić, N., Liu, Y., Liyu, A., Shen, Y., Tfaily, M. M., Kujawinski, E. B., Longnecker, K., Kuo, L.-J., Robinson, E. W., Paša-Tolić, L., et al. (2017) · Analytical Chemistry · doi:10.1021/acs.analchem.7b03318 · Cited by 261
Phosphoproteomics in the Age of Rapid and Deep Proteome Profiling
Riley, N. M., & Coon, J. J. (2016) · Analytical Chemistry · doi:10.1021/acs.analchem.5b04123 · Cited by 265
Metadata
- Authors
- Hendrickson, C. L., Quinn, J. P., Kaiser, N. K., Smith, D. F., Blakney, G. T., Chen, T., Marshall, A. G., Weisbrod, C. R., & Beu, S. C.
- Affiliations
- Florida State University (US)
- S. C. Beu Consulting, 12449 Los Indios Trail, 78729, Austin, TX, USA
- ORCID
- Venue
- Journal of the American Society for Mass Spectrometry
- Publisher
- American Chemical Society (ACS)
- Published
- 2015-06-20
- Volume
- 26
- Issue
- 9
- Pages
- 1626-1632
- ISSN
- 1044-0305 (ISSN-L)
- OpenAlex
- W781416032
- Cited by
- 278
- References
- 37
- Citations by year
- 2026: 17 · 2025: 25 · 2024: 33 · 2023: 35 · 2022: 23 · 2021: 35 · 2020: 30 · 2019: 29 · 2018: 19 · 2017: 17 · 2016: 9 · 2015: 3
- FWCI
- 7.12
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.springer.com/tdm (tdm)
- Locations
- Journal of the American Society for Mass Spectrometry (publishedVersion)
- PubMed (publishedVersion)
- Funders
- National High Magnetic Field Laboratory
- Topics
- Physical Sciences › Chemistry › Spectroscopy › Mass Spectrometry Techniques and Applications
- Physical Sciences › Chemistry › Spectroscopy › Advanced Proteomics Techniques and Applications
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Molecular Biology › Metabolomics and Mass Spectrometry Studies
- Keywords
- Fourier transform ion cyclotron resonance, ultrahigh-resolution mass spectrometry, electron transfer dissociation, collision-induced dissociation, mass resolving power, mass accuracy, bovine serum albumin, carbonic anhydrase, protein sequencing
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.