Determination of pulse wave velocities with computerized algorithms
The DOI matches its Crossref record; 16 of the 16 references it cites were found in a registry or an index.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Björck, Å., Dahlquist, G. G., & Anderson, N. (1974) · Cited by 1,719
Hamming, R. W., & Stearns, S. D. (1977) · Cited by 1,275
Aortic input impedance in normal man: relationship to pressure wave forms.
Murgo, J. P., Westerhof, N., Giolma, J. P., & Altobelli, S. A. (1980) · Circulation · doi:10.1161/01.cir.62.1.105 · Cited by 1,014
Latham, R. D., Westerhof, N., Sipkema, P., Rubal, B. J., Reuderink, P., & Murgo, J. P. (1985) · Circulation · doi:10.1161/01.cir.72.6.1257 · Cited by 454
O'ROURKE, M. F., Blazek, J. V., Morreels, C. L., & Krovetz, L. J. (1968) · Circulation Research · doi:10.1161/01.res.23.4.567 · Cited by 241
The Pulse Wave Velocity as an Early Indicator of Atherosclerosis in Diabetic Subjects
WOOLAM, G. L., SCHNUR, P. L., VALLBONA, C., & HOFF, H. E. (1962) · Circulation · doi:10.1161/01.cir.25.3.533 · Cited by 171
Dispersion and Attenuation of Small Artificial Pressure Waves in the Canine Aorta
ANLIKER, M., HISTAND, M. B., & OGDEN, E. (1968) · Circulation Research · doi:10.1161/01.res.23.4.539 · Cited by 141
Pulse wave velocity in patients with obesity and hypertension
Toto-Moukouo, J. J., Achimastos, A. D., Asmar, R. G., Hugues, C., & Safar, M. E. (1986) · American Heart Journal · doi:10.1016/0002-8703(86)90691-5 · Cited by 139
Arterial wave reflection in heart failure.
Laskey, W. K., & Kussmaul, W. G. (1987) · Circulation · doi:10.1161/01.cir.75.4.711 · Cited by 138
Wave-velocity in the proximal aorta
Nichols, W. W., & McDonald, D. A. (1972) · Medical & Biological Engineering & Computing · doi:10.1007/bf02474213 · Cited by 87
Cited by
Expert consensus document on arterial stiffness: methodological issues and clinical applications
Laurent, S., Cockcroft, J., Van Bortel, L., Boutouyrie, P., Giannattasio, C., Hayoz, D., Pannier, B., Vlachopoulos, C., Wilkinson, I., Struijker-Boudier, H., et al. (2006) · European Heart Journal · doi:10.1093/eurheartj/ehl254 · Cited by 6,077
“However, distance should be measured precisely because small inaccuracies may influence the absolute value of PWV.(46) The shorter the distance between two recordings sites, the greater the absolute error in determining the transit time.”
BackgroundInfluentialYAMASHINA, A., TOMIYAMA, H., TAKEDA, K., TSUDA, H., ARAI, T., HIROSE, K., KOJI, Y., HORI, S., & YAMAMOTO, Y. (2002) · Hypertension Research · doi:10.1291/hypres.25.359 · Cited by 1,623
Toward ubiquitous blood pressure monitoring via pulse transit time: Theory and practice
Mukkamala, R., Hahn, J.-O., Inan, O. T., Mestha, L. K., Kim, C.-S., Toreyin, H., & Kyal, S. (2015) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2015.2441951 · Cited by 935
“…with respect to time [134]; 3) a fraction of the pulse pressure [49], [135]; and (d) the intersection of the horizontal line through the minimum and the tangent line fitted through points near the maximum first derivative with respect to time (i.e., intersecting tangent method) [43], [45], [134].”
BackgroundInfluentialHow accurate is pulse rate variability as an estimate of heart rate variability?
Schäfer, A., & Vagedes, J. (2013) · International Journal of Cardiology · doi:10.1016/j.ijcard.2012.03.119 · Cited by 661
Pulse transit time measured from the ECG: an unreliable marker of beat-to-beat blood pressure
Payne, R. A., Symeonides, C. N., Webb, D. J., & Maxwell, S. R. J. (2006) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00657.2005 · Cited by 418
“4)* Norepinephrine Baseline 261 (15) 95 (19) 165 (18) 61 (8) 141 (10) 68 (6) 86 (7) Maximum 238 (18) 87 (19) 151 (20) 57 (8) 164 (13) 81 (8) 104 (10) Change 22.”
BackgroundMethods and devices for measuring arterial compliance in humans
Pannier, B. M., Avolio, A. P., Hoeks, A., Mancia, G., & Takazawa, K. (2002) · American Journal of Hypertension · doi:10.1016/s0895-7061(02)02962-x · Cited by 343
Webb, A. J. S., Simoni, M., Mazzucco, S., Kuker, W., Schulz, U., & Rothwell, P. M. (2012) · Stroke · doi:10.1161/strokeaha.112.655837 · Cited by 304
“2) * 44 (13) 42 (14) 156 (18) 156 (23) 9.”
InfluentialPulse wave analysis and pulse wave velocity: a critical review of their strengths and weaknesses
Davies, J. I., & Struthers, A. D. (2003) · Journal of Hypertension · doi:10.1097/00004872-200303000-00004 · Cited by 289
Evaluation of Carotid-Femoral Pulse Wave Velocity: Influence of Timing Algorithm and Heart Rate
Millasseau, S. C., Stewart, A. D., Patel, S. J., Redwood, S. R., & Chowienczyk, P. J. (2005) · Hypertension · doi:10.1161/01.hyp.0000154229.97341.d2 · Cited by 289
Muscular Strength Training Is Associated With Low Arterial Compliance and High Pulse Pressure
Bertovic, D. A., Waddell, T. K., Gatzka, C. D., Cameron, J. D., Dart, A. M., & Kingwell, B. A. (1999) · Hypertension · doi:10.1161/01.hyp.33.6.1385 · Cited by 283
Langrish, J. P., Mills, N. L., Bath, L. E., Warner, P., Webb, D. J., Kelnar, C. J., Critchley, H. O. D., Newby, D. E., & Wallace, W. H. B. (2009) · Hypertension · doi:10.1161/hypertensionaha.108.126516 · Cited by 207
Cuffless Blood Pressure Measurement
Mukkamala, R., Stergiou, G. S., & Avolio, A. P. (2022) · Annual Review of Biomedical Engineering · doi:10.1146/annurev-bioeng-110220-014644 · Cited by 180
Arterial stiffness: clinical relevance, measurement and treatment
Hamilton, P. K., Lockhart, C. J., Quinn, C. E., & Mcveigh, G. E. (2007) · Clinical Science · doi:10.1042/cs20070080 · Cited by 174
Validation of a device to measure arterial pulse wave velocity by a photoplethysmographic method
Loukogeorgakis, S., Dawson, R., Phillips, N., Martyn, C. N., & Greenwald, S. E. (2002) · Physiological Measurement · doi:10.1088/0967-3334/23/3/309 · Cited by 164
Gao, M., Olivier, N. B., & Mukkamala, R. (2016) · Physiological Reports · doi:10.14814/phy2.12768 · Cited by 86
“The minimum, maximum double derivative, intersection of tangent lines, maximum derivative, and peak of the BF, BP, and PPG waveforms and the R-wave of the ECG waveform were automatically detected for each beat to establish multiple versions of each time delay (Chiu et al. 1991; Gao et al. 2014).”
BackgroundA new approach for non-intrusive monitoring of blood pressure on a toilet seat
Kim, J. S., Chee, Y. J., Park, J. W., Choi, J. W., & Park, K. S. (2006) · Physiological Measurement · doi:10.1088/0967-3334/27/2/010 · Cited by 64
The effect of applied sensor contact force on pulse transit time
Teng, X. F., & Zhang, Y. T. (2006) · Physiological Measurement · doi:10.1088/0967-3334/27/8/002 · Cited by 53
Experimental validation of dual PPG local pulse wave velocity probe
Nabeel, P. M., Karthik, S., Joseph, J., & Sivaprakasam, M. (2017) · 2017 IEEE International Symposium on Medical Measurements and Applications (MeMeA) · doi:10.1109/memea.2017.7985911 · Cited by 20
“Characteristic points of blood pulse waveforms can be determined by techniques such as; foot-to-foot (FTF), first derivative maximum (FDM), intersecting tangent, and second derivative maximum (SDM) methods [15].”
Method
Metadata
- Authors
- Chiu, Y. C., Arand, P. W., Shroff, S. G., Feldman, T., & Carroll, J. D.
- Venue
- American Heart Journal
- Publisher
- Elsevier BV
- Published
- 1991-05
- Volume
- 121
- Issue
- 5
- Pages
- 1460-1470
- ISSN
- 0002-8703 (ISSN-L)
- OpenAlex
- W2130966532
- Cited by
- 313
- References
- 16
- FWCI
- 0.34
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.