Tactile sensory coding in the glabrous skin of the human hand
The DOI matches its Crossref record; 23 of the 23 references it cites were found in a registry or an index.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Peripheral nerve contains both afferent and efferent fibers; additionally, multiple types of sensory fibers are present, and activation of these fibers produce sensations with distinct qualities [21,22].”
From Fascicle specific targeting for selective peripheral nerve stimulation (2019) · cites this paper as [21]
Citations
Cites
Somatosensory, proprioceptive, and sympathetic activity in human peripheral nerves
Vallbo, A. B., Hagbarth, K. E., Torebjork, H. E., & Wallin, B. G. (1979) · Physiological Reviews · doi:10.1152/physrev.1979.59.4.919 · Cited by 1,507
Self-citationJohansson, R. S., & Vallbo, A. B. (1979) · The Journal of Physiology · doi:10.1113/jphysiol.1979.sp012619 · Cited by 1,291
Self-citationTalbot, W. H., Darian-Smith, I., Kornhuber, H. H., & Mountcastle, V. B. (1968) · Journal of Neurophysiology · doi:10.1152/jn.1968.31.2.301 · Cited by 990
McCloskey, D. I. (1978) · Physiological Reviews · doi:10.1152/physrev.1978.58.4.763 · Cited by 819
(1974) · Springer eBooks · doi:10.1007/978-1-4615-8699-9 · Cited by 626
Activity from skin mechanoreceptors recorded percutaneously in awake human subjects
Vallbo, Å. B., & Hagbarth, K.-E. (1968) · Experimental Neurology · doi:10.1016/0014-4886(68)90041-1 · Cited by 530
Self-citationJohansson, R. S., Landstro¨m, U., & Lundstro¨m, R. (1982) · Brain Research · doi:10.1016/0006-8993(82)90899-x · Cited by 434
Self-citationJohansson, R. S. (1978) · The Journal of Physiology · doi:10.1113/jphysiol.1978.sp012411 · Cited by 430
Self-citationStimulus‐response functions of slowly adapting mechanoreceptors in the human glabrous skin area.
Knibestöl, M. (1975) · The Journal of Physiology · doi:10.1113/jphysiol.1975.sp010835 · Cited by 335
Phillips, J. R., & Johnson, K. O. (1981) · Journal of Neurophysiology · doi:10.1152/jn.1981.46.6.1192 · Cited by 330
Research works printed but not linked: 1
- Burgess, 1973, Vol. 2, 29
Cited by
Coding and use of tactile signals from the fingertips in object manipulation tasks
Johansson, R. S., & Flanagan, J. R. (2009) · Nature Reviews Neuroscience · doi:10.1038/nrn2621 · Cited by 2,063
“Second, the variation in axonal conduction velocity between afferents of the same functional typ”
BackgroundSelf-citationJohansson, R. S., & Westling, G. (1984) · Experimental Brain Research · doi:10.1007/bf00237997 · Cited by 1,703
Self-citationLederman, S. J., & Klatzky, R. L. (2009) · Attention, Perception & Psychophysics · doi:10.3758/app.71.7.1439 · Cited by 1,108
“Figure 1 shows the structure of palmar skin, together with the specialized nerve endings of the four mechanoreceptor populations that human neuroscience has shown are distributed within this region (see Johansson & Vallbo, 1983).”
BackgroundFactors influencing the force control during precision grip
Westling, G., & Johansson, R. S. (1984) · Experimental Brain Research · doi:10.1007/bf00238156 · Cited by 1,027
“The glabrous skin of the human hand, and particulary the finger tips, has an extremly high density of mechanoreceptors, which can accurately signal a variety of mechanical events (for ref. see Johansson and Vallbo 1983 ).”
BackgroundSelf-citation(1984) · PubMed · Cited by 908
Self-citationJohansson, R. S., & Westling, G. (1987) · Experimental Brain Research · doi:10.1007/bf00236210 · Cited by 865
“(For classification criteria and general functional properties of the different types of tactile units see the accompanying paper and Johansson and Vallbo 1983 .) The object was gripped between the thumb and one of the three radial fingers such that the receptive field of the afferent recorded was in contact with the…”
BackgroundSelf-citationFirst spikes in ensembles of human tactile afferents code complex spatial fingertip events
Johansson, R. S., & Birznieks, I. (2004) · Nature Neuroscience · doi:10.1038/nn1177 · Cited by 638
“Based on adaptation to sustained skin indentation and properties of the cutaneous receptive fiel”
BackgroundSelf-citationResponses in glabrous skin mechanoreceptors during precision grip in humans
Westling, G., & Johansson, R. S. (1987) · Experimental Brain Research · doi:10.1007/bf00236209 · Cited by 485
“However, due to their receptive field properties and their low and fairly uniform densities in the hand, they seem ineffectual for encoding spatially distributed tactile stimuli (Johansson and Vallbo 1983; Johnson 1983).”
Self-citationDistribution and behaviour of glabrous cutaneous receptors in the human foot sole
Kennedy, P. M., & Inglis, J. T. (2002) · The Journal of Physiology · doi:10.1113/jphysiol.2001.013087 · Cited by 438
Encoding of Direction of Fingertip Forces by Human Tactile Afferents
Birznieks, I., Jenmalm, P., Goodwin, A. W., & Johansson, R. S. (2001) · The Journal of Neuroscience · doi:10.1523/jneurosci.21-20-08222.2001 · Cited by 356
“The afferents were classified as fast adapting type I (FA-I), fast adapting type II (FA-II), slowly adapting type I (SA-I), and slowly adapting type II (SA-II) according to criteria described previously ( Johansson and Vallbo, 1983; Vallbo and Johansson, 1984).”
BackgroundMethodInfluentialSelf-citationSpinal sensorimotor systems and their supraspinal control
Schomburg, E. D. (1990) · Neuroscience Research · doi:10.1016/0168-0102(90)90008-3 · Cited by 355
Nerve injury and repair – a challenge to the plastic brain
Lundborg, G. (2003) · Journal of the Peripheral Nervous System · doi:10.1111/j.1085-9489.2003.03027.x · Cited by 327
“and subcutaneous layers of the skin, responding to pressure, vibration, and stretching (Johansson and Vallbo, 1983; Johansson and Westling, 1984; Vallbo and Johansson, 1984; Edin and Johansson, 1995; Johansson, 2000).”
BackgroundSeitz, R. J., & Roland, P. E. (1992) · European Journal of Neuroscience · doi:10.1111/j.1460-9568.1992.tb00862.x · Cited by 321
Sensory feedback for limb prostheses in amputees
Raspopovic, S., Valle, G., & Petrini, F. M. (2021) · Nature Materials · doi:10.1038/s41563-021-00966-9 · Cited by 308
Finger pad friction and its role in grip and touch
Adams, M. J., Johnson, S. A., Lefèvre, P., Lévesque, V., Hayward, V., André, T., & Thonnard, J.-L. (2013) · Journal of The Royal Society Interface · doi:10.1098/rsif.2012.0467 · Cited by 293
“The dynamic tactile signals from the cutaneous mechanoreceptors reliably encode various aspects of contact events around which most object manipulation tasks are organized [3,4].”
BackgroundHowe, R. D., Peine, W. J., Kantarinis, D. A., & Son, J. S. (1995) · IEEE Engineering in Medicine and Biology Magazine · doi:10.1109/51.391770 · Cited by 296
Sensory‐motor function of human periodontal mechanoreceptors*
TRULSSON, M. (2006) · Journal of Oral Rehabilitation · doi:10.1111/j.1365-2842.2006.01629.x · Cited by 269
Development of Soft-Actuator-Based Wearable Tactile Display
Koo, I. M., Jung, K., Koo, J. C., Nam, J.-D., Lee, Y. K., & Choi, H. R. (2008) · IEEE Transactions on Robotics · doi:10.1109/tro.2008.921561 · Cited by 277
“Although the graphical or visual device has been a typical form of the modern information transferring tool, the role of the tactile display has been extended to various applications such as attaining realities in video games or guaranteeing accuracy in telemanipulation [1]–[4].”
BackgroundRice, F. L., Mance, A., & Munger, B. L. (1986) · Journal of Comparative Neurology · doi:10.1002/cne.902520203 · Cited by 271
The Circuitry of the Human Spinal Cord : Its Role in Motor Control and Movement Disorders
Pierrot-Deseilligny, E., & Burke, D. J. (2009) · Cited by 273
DexPilot: Vision-Based Teleoperation of Dexterous Robotic Hand-Arm System
Handa, A., Van Wyk, K., Yang, W., Liang, J., Chao, Y.-W., Wan, Q., Birchfield, S., Ratliff, N., & Fox, D. (2020) · 2020 IEEE International Conference on Robotics and Automation (ICRA) · doi:10.1109/icra40945.2020.9197124 · Cited by 209
“Still, these other solutions are important to investigating how relaying tactile feedback to human pilots improve teleoperation capability, considering that numerous neurophysiological studies have uncovered the importance of tactile feedback in human sensorimotor control of the human hand [12, 20, 21].”
BackgroundHand function after nerve repair
Lundborg, G., & Rosén, B. (2007) · Acta Physiologica · doi:10.1111/j.1748-1716.2006.01653.x · Cited by 249
“…of the mechanoreceptors in the subepidermal, dermal and subcutaneous layers of the volar glabour skin of the hand have been well defined and described in numerous investigations (Johansson & Vallbo 1983, Johansson & Vallbo 1979, Stark et al. 1998, Vallbo & Hagbarth 1968, Vallbo & Johansson 1984).”
Tactile Display of Vibratory Information in Teleoperation and Virtual Environments
Kontarinis, D. A., & Howe, R. D. (1995) · Presence: Teleoperators and Virtual Environments · doi:10.1162/pres.1995.4.4.387 · Cited by 251
“There are four types of specialized mechanoreceptor nerve endings in the glabrous skin of the human hand which play important roles in manipulation tasks (Johansson & Vallbo, 1983) .”
BackgroundMethodInfluentialSmart Tactile Gloves for Haptic Interaction, Communication, and Rehabilitation
Ozioko, O., & Dahiya, R. (2022) · Advanced Intelligent Systems · doi:10.1002/aisy.202100091 · Cited by 233
Macefield, V., H�ger-Ross, C., & Johansson, R. (1996) · Experimental Brain Research · doi:10.1007/bf00242913 · Cited by 230
“The afferents were classified as FA I, FAII, SA I, and SAII according to criteria previously described (e.g., Johansson and Vallbo 1983; Vallbo and Johansson 1984).”
InfluentialSelf-citationSensing skin acceleration for slip and texture perception
Howe, R. D., & Cutkosky, M. R. (2003) · Proceedings, 1989 International Conference on Robotics and Automation · doi:10.1109/robot.1989.99981 · Cited by 232
Shifting the balance: evidence of an exploratory role for postural sway
Carpenter, M. G., Murnaghan, C. D., & Inglis, J. T. (2010) · Neuroscience · doi:10.1016/j.neuroscience.2010.08.030 · Cited by 194
Tactile displays: Overview and recent advances
Chouvardas, V. G., Miliou, A. N., & Hatalis, M. K. (2008) · Displays · doi:10.1016/j.displa.2007.07.003 · Cited by 211
“These characteristics classify mechanoreceptive units into four categories: rapidly adapting I and II (RAI and RAII) and slowly adapting I and II (SAI and SAII), whose end organs are Meissner corpuscles, Pacinian corpuscles, Merkel cell neurite complexes, and Ruffini endings, respectively [14], – spatial features of p…”
BackgroundTactile roughness perception with a rigid link interposed between skin and surface
Klatzky, R. L., & Lederman, S. J. (1999) · Perception & Psychophysics · doi:10.3758/bf03205532 · Cited by 209
“The FAIIs are characterized by responses to relatively high-frequency vibrations, peaking in response in the region of 250 Hz (Johansson & Vallbo, 1983).”
BackgroundSeitz, R. J., & Roland, P. E. (1992) · Acta Neurologica Scandinavica · doi:10.1111/j.1600-0404.1992.tb08055.x · Cited by 205
The cutaneous contribution to adaptive precision grip
Witney, A. G., Wing, A., Thonnard, J.-L., & Smith, A. M. (2004) · Trends in Neurosciences · doi:10.1016/j.tins.2004.08.006 · Cited by 203
“These physiologically characterized afferents are thought to originate from Merkel cell complexes and Meissner corpuscles [ 6 ,7].”
BackgroundSrinivasan, M. A., & Dandekar, K. (1996) · Journal of Biomechanical Engineering · doi:10.1115/1.2795945 · Cited by 202
Low-Threshold Mechanoreceptive Afferents in the Human Lingual Nerve
Trulsson, M., & Essick, G. K. (1997) · Journal of Neurophysiology · doi:10.1152/jn.1997.77.2.737 · Cited by 186
“This distinction was described previously studied (see Edin et al. 1995; Johansson and Vallbo 1983; for the SA I and SA II units of the hand by Edin (1992), Vallbo et al. 1979). who observed broad, positively skewed distributions and This conclusion is supported by Fig.”
BackgroundResultDimensions of Spatial Acuity in the Touch Sense: Changes over the Life Span
Stevens, J. C., & Patterson, M. Q. (1995) · Somatosensory & Motor Research · doi:10.3109/08990229509063140 · Cited by 175
Fundamental Limits of Performance for Force Reflecting Teleoperation
Daniel, R. W., & McAree, P. R. (1998) · The International Journal of Robotics Research · doi:10.1177/027836499801700801 · Cited by 175
“We contrast this with the more commonly used two-port framework; see, for instance Raju, Verghese, and Sheridan (1989); Niemeyer and Slotine (1991); Anderson and Spong ( 1989,1992); Colgate (1991); Lawrence (1993); and Yokokohji and Yoshikawa (1994), which group the slave and master.”
Rate-hardness: a new performance metric for haptic interfaces
Lawrence, D. A., Pao, L. Y., Dougherty, A. M., Salada, M. A., & Pavlou, Y. (2000) · IEEE Transactions on Robotics and Automation · doi:10.1109/70.864228 · Cited by 170
“These high-frequency forces bring subtle surface qualities into the perceptual range of sensory receptors in the fingers [2], [12], [28].”
BackgroundIn vivo biomechanics of the fingerpad skin under local tangential traction
Wang, Q., & Hayward, V. (2007) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2006.03.004 · Cited by 161
“The response of individual afferents were found to be dependent on the direction of skin stretch (Johansson and Vallbo, 1983) or on the direction of stimulus movement (LaMotte and Srinivasan, 1987a,b).”
BackgroundNaito, E., Nakashima, T., Kito, T., Aramaki, Y., Okada, T., & Sadato, N. (2007) · European Journal of Neuroscience · doi:10.1111/j.1460-9568.2007.05587.x · Cited by 158
“In a control condition for the skin vibration, which may recruit vibro-tactile receptors (Johansson & Vallbo, 1983), we applied identical stimuli to the skin surface over a nearby bone beside the tendon, which does not elicit any illusions (VIBRATION).”
Konstantinova, J., Jiang, A., Althoefer, K., Dasgupta, P., & Nanayakkara, T. (2014) · IEEE Sensors Journal · doi:10.1109/jsen.2014.2325794 · Cited by 166
A COMPREHENSIVE APPROACH TO UNDERSTANDING TEXTURAL PROPERTIES OF SEMI‐ AND SOFT‐SOLID FOODS
FOEGEDING, E. A., DAUBERT, C. R., DRAKE, M. A., ESSICK, G., TRULSSON, M., VINYARD, C. J., & VAN DE VELDE, F. (2011) · Journal of Texture Studies · doi:10.1111/j.1745-4603.2011.00286.x · Cited by 160
Trulsson, M., & Johansson, R. S. (2002) · Behavioural Brain Research · doi:10.1016/s0166-4328(02)00151-1 · Cited by 182
“…afferents that supply the human facial skin, lips and oral mucosa show properties similar to those of tactile afferents of the human hand, i.e. hair follicle afferents and three types of afferents described in the glabrous skin (FA I, SA I and SA II afferents; see Johansson and Vallbo 1983).”
BackgroundSelf-citationKessler, W., Kirchhoff, C., Reeh, P. W., & Handwerker, H. O. (1992) · Experimental Brain Research · doi:10.1007/bf00227842 · Cited by 159
Fingerpad‐Inspired Multimodal Electronic Skin for Material Discrimination and Texture Recognition
Lee, G., Son, J. H., Lee, S., Kim, S. W., Kim, D., Nguyen, N. N., Lee, S. G., & Cho, K. (2021) · Advanced Science · doi:10.1002/advs.202002606 · Cited by 153
Gordon, A. M., & Duff, S. (1999) · Developmental Medicine & Child Neurology · doi:10.1111/j.1469-8749.1999.tb00576.x · Cited by 173
“Overall, the use of the lateral pinch resulted in higher grip forces and small increases in some temporal parameters in control children, most likely due to the decreased density of mechanoreceptors located in the lateral skin (Johansson and Vallbo 1983).”
BackgroundENCODING OF TOOTH LOADS BY HUMAN PERIODONTAL AFFERENTS AND THEIR ROLE IN JAW MOTOR CONTROL
Trulsson, M., & Johansson, R. S. (1996) · Progress in Neurobiology · doi:10.1016/s0301-0082(96)00016-0 · Cited by 152
Self-citationAcquisition and interpretation of 3-D sensor data from touch
Allen, P. K., & Michelman, P. (1990) · IEEE Transactions on Robotics and Automation · doi:10.1109/70.59353 · Cited by 158
Ribot‐Ciscar, E., Vedel, J., & Roll, J. (1989) · Neuroscience Letters · doi:10.1016/0304-3940(89)90342-x · Cited by 148
Tactile acuity, aging, and braille reading in long-term blindness.
Stevens, J. C., Foulke, E., & Patterson, M. Q. (1996) · Journal of Experimental Psychology: Applied · doi:10.1037/1076-898x.2.2.91 · Cited by 147
The nature of human prehension: Three dextrous hands in one
Iberall, T. (2005) · Proceedings - IEEE International Conference on Robotics and Automation/Proceedings · doi:10.1109/robot.1987.1087813 · Cited by 146
Jenmalm, P., Birznieks, I., Goodwin, A. W., & Johansson, R. S. (2003) · European Journal of Neuroscience · doi:10.1046/j.1460-9568.2003.02721.x · Cited by 141
Self-citationSkin‐Integrated Vibrohaptic Interfaces for Virtual and Augmented Reality
Jung, Y. H., Kim, J., & Rogers, J. A. (2020) · Advanced Functional Materials · doi:10.1002/adfm.202008805 · Cited by 147
Representation of braille characters in human nerve fibres
Phillips, J. R., Johansson, R. S., & Johnson, K. O. (1990) · Experimental Brain Research · doi:10.1007/bf02423508 · Cited by 141
“There have been no reported studies of the responses of human afferents to scanned stimuli, and although mechanoreceptor responses to stationary punctate stimuli are well documented (Johansson and Vallbo 1983) these cannot be used as a reliable basis for predicting responses to scanned stimuli like Braille.”
BackgroundSelf-citationAimonetti, J., Hospod, V., Roll, J., & Ribot‐Ciscar, E. (2007) · The Journal of Physiology · doi:10.1113/jphysiol.2006.123075 · Cited by 140
“As suggested by previous authors, ‘the cutaneous mechanoreceptors, and particularly the SA II and FA II units, may provide not only exteroceptive but also proprioceptive information’ (Johansson & Vallbo, 1983).”
ResultEffect of skin hydration on the dynamics of fingertip gripping contact
André, T., Lévesque, V., Hayward, V., Lefèvre, P., & Thonnard, J. (2011) · Journal of The Royal Society Interface · doi:10.1098/rsif.2011.0086 · Cited by 146
A Novel Thick-Film Piezoelectric Slip Sensor for a Prosthetic Hand
Cotton, D. P. J., Chappell, P. H., Cranny, A., White, N. M., & Beeby, S. P. (2007) · IEEE Sensors Journal · doi:10.1109/jsen.2007.894912 · Cited by 135
“Each sensor replicates a type of sensor found in the natural human hand [20].”
BackgroundDynamic Contact of the Human Fingerpad Against a Flat Surface
Pawluk, D. T. V., & Howe, R. D. (1999) · Journal of Biomechanical Engineering · doi:10.1115/1.2800860 · Cited by 135
Encoding of Object Curvature by Tactile Afferents From Human Fingers
Goodwin, A. W., Macefield, V. G., & Bisley, J. W. (1997) · Journal of Neurophysiology · doi:10.1152/jn.1997.78.6.2881 · Cited by 126
The Role of Cutaneous Receptors in the Foot
Inglis, J. T., Kennedy, P. M., Wells, C., & Chua, R. (2002) · Advances in experimental medicine and biology · doi:10.1007/978-1-4615-0713-0_14 · Cited by 150
Spike timing–based coding in neuromimetic tactile system enables dynamic object classification
Chen, L., Karilanova, S., Chaki, S., Wen, C., Wang, L., Winblad, B. G., Zhang, S., Özçelikkale, A., & Zhang, Z. (2024) · Science · doi:10.1126/science.adf3708 · Cited by 130
Digital vibrogram: A new diagnostic tool for sensory testing in compression neuropathy
Lundborg, G., Lie-Stenström, A.-K., Sollerman, C., Strömberg, T., & Pyykkö, I. V. (1986) · The Journal Of Hand Surgery · doi:10.1016/s0363-5023(86)80014-4 · Cited by 127
Sensitivity of the hand to surface pressure
Fransson‐Hall, C., & Kilbom, Å. (1993) · Applied Ergonomics · doi:10.1016/0003-6870(93)90006-u · Cited by 121
Surface acoustic wave tactile display
Nara, T., TAKASAKI, M., Maeda, T., Higuchi, T., Ando, S., & Tachi, S. (2001) · IEEE Computer Graphics and Applications · doi:10.1109/38.963461 · Cited by 119
A tactile sensor for localizing transient events in manipulation
Son, J. S., Monteverde, E. A., & Howe, R. D. (2002) · Proceedings - IEEE International Conference on Robotics and Automation/Proceedings · doi:10.1109/robot.1994.351253 · Cited by 118
The effect of surface wave propagation on neural responses to vibration in primate glabrous skin
Manfredi, L. R., Baker, A. T., Elias, D. O., Dammann, J. F., Zielinski, M. C., Polashock, V. S., & Bensmaia, S. J. (2012) · PLoS ONE · doi:10.1371/journal.pone.0031203 · Cited by 117
Edin, B., Essick, G., Trulsson, M., & Olsson, K. (1995) · The Journal of Neuroscience · doi:10.1523/jneurosci.15-01-00830.1995 · Cited by 117
“Based on RF size, adaptation properties, presence of spontaneous activity, and regularity of evoked response, all units were classified as SAI, SAII, FAI, or FAII using standard criteria recommended by Vallbo and others (Knibestiil and Vallbo, 1970; Johansson and Vallbo, 1983; Vallbo, 1989).”
MethodMethods and Sensors for Slip Detection in Robotics: A Survey
Romeo, R. A., & Zollo, L. (2020) · IEEE Access · doi:10.1109/access.2020.2987849 · Cited by 134
“In particular, FA II units exhibit high sensitivity to acceleration and quick transients [20].”
BackgroundOn the choice of grasp type and location when handing over an object
Cini, F., Ortenzi, V., Corke, P., & Controzzi, M. (2019) · Science Robotics · doi:10.1126/scirobotics.aau9757 · Cited by 120
An Extreme Learning Machine-Based Neuromorphic Tactile Sensing System for Texture Recognition
Rasouli, M., Yi, C., Basu, A., Kukreja, S. L., & Thakor, N. V. (2018) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2018.2805721 · Cited by 123
“SA receptors produce spikes at a frequency proportional to intensity of stimulus, while FA receptors respond to changes of stimulus intensity [49].”
Tactile Sensory Control of Object Manipulation in Humans
Johansson, R. S., & Flanagan, J. R. (2008) · The Senses: A Comprehensive Reference · doi:10.1016/b978-012370880-9.00346-7 · Cited by 109
Self-citationSurface finish and touch—a case study in a new human factors tribology
Barnes, C., Childs, T. H. C., Henson, B. W., & Southee, C. (2004) · Wear · doi:10.1016/j.wear.2004.03.018 · Cited by 120
Age-related changes in cutaneous sensation in the healthy human hand
Bowden, J. L., & McNulty, P. A. (2013) · AGE · doi:10.1007/s11357-012-9429-3 · Cited by 93
“In the glabrous, or hairless, skin of the palmar surface of the hand there are four low-threshold mechanoreceptors that subserve cutaneous sensation (for review, see Johansson and Vallbo 1983).”
BackgroundParadigms for restoration of somatosensory feedback via stimulation of the peripheral nervous system
Pasluosta, C. F., Kiele, P., & Stieglitz, T. (2017) · Clinical Neurophysiology · doi:10.1016/j.clinph.2017.12.027 · Cited by 111
Delhaye, B. P., Jarocka, E., Barrea, A., Thonnard, J., Edin, B. B., & Lefèvre, P. (2021) · eLife · doi:10.7554/elife.64679 · Cited by 110
Marshall, C. D., Amin, H., Kovacs, K. M., & Lydersen, C. (2005) · The Anatomical Record Part A Discoveries in Molecular Cellular and Evolutionary Biology · doi:10.1002/ar.a.20273 · Cited by 105
“They are type I slowly adapting mechanoreceptors (Iggo, 1963, 1966; Munger et al., 1971) that detect compression stimuli (Andres, 1966; Johansson et al., 1982a, 1982b; Johansson and Vallbo, 1983).”
BackgroundMorioka, M., & Griffin, M. J. (2005) · Somatosensory & Motor Research · doi:10.1080/08990220500420400 · Cited by 104
Perception of ultrasonic haptic feedback on the hand: localisation and apparent motion
Wilson, G., Carter, T., Subramanian, S., & Brewster, S. A. (2014) · CHI Conference on Human Factors in Computing Systems · doi:10.1145/2556288.2557033 · Cited by 103
“Pacinian corpuscles (PC), the rapidly adapting mechanoreceptors that are sensitive to vibration and ultrasonic haptic stimulation [22], are most densely populated in the fingertips and less dense in the fingers and palm [16].”
BackgroundInfluential̈fvenberg, J. L., & Johansson, R. S. (1984) · Brain Research · doi:10.1016/0006-8993(84)90403-7 · Cited by 101
Self-citationActive touch perception produced by airborne ultrasonic haptic hologram
Inoue, S., Makino, Y., & Shinoda, H. (2015) · IEEE World Haptics Conference (WHC) · doi:10.1109/whc.2015.7177739 · Cited by 100
“Note that this should be impossible to determine using a vibrotactile approach because the corresponding single receptor (FA II) has a wide ranging receptive field that covers nearly half of the palm [15].”
BackgroundRegional Variation and Changes With Ageing in Vibrotactile Sensitivity in the Human Footsole
Wells, C., Ward, L. M., Chua, R., & Inglis, J. T. (2003) · The Journals of Gerontology Series A: Biological Sciences and Medical Sciences · doi:10.1093/gerona/58.8.b680 · Cited by 97
“Recently, it was determined that all 4 types of receptors and afferents also exist in the human footsole (6), although their distribution and thresholds of activation were different from those described for the hand (5).”
BackgroundLang, S., Klein, T., Magerl, W., & Treede, R. (2006) · Pain · doi:10.1016/j.pain.2006.09.026 · Cited by 107
“Brushing and touch by a blunt v. Frey type probe predominantly activate Ab-fiber low-threshold mechanoreceptors (Johansson and Vallbo, 1983; Leem et al., 1993).”
BackgroundSlowly Adapting Mechanoreceptors in the Borders of the Human Fingernail Encode Fingertip Forces
Birznieks, I., Macefield, V. G., Westling, G., & Johansson, R. S. (2009) · The Journal of Neuroscience · doi:10.1523/jneurosci.0143-09.2009 · Cited by 97
“Afferents were classified according to criteria described previously (Johansson and Vallbo, 1983; Vallbo and Johansson, 1984).”
MethodSelf-citationBobjer, O., Johansson, S.-E., & Piguet, S. (1993) · Applied Ergonomics · doi:10.1016/0003-6870(93)90007-v · Cited by 97
A tactile shape sensing and display system for teleoperated manipulation
Kontarinis, D. A., Son, J. S., Peine, W. J., & Howe, R. D. (2002) · Proceedings - IEEE International Conference on Robotics and Automation/Proceedings · doi:10.1109/robot.1995.525356 · Cited by 108
Improved Sensorimotor Performance via Stochastic Resonance
Méndez‐Balbuena, I., Manjarrez, E., Schulte‐Mönting, J., Huethe, F., Tapia, J. A., Hepp‐Reymond, M., & Kristeva, R. (2012) · Journal of Neuroscience · doi:10.1523/jneurosci.0680-12.2012 · Cited by 108
“However, only the recording of sensory afferents by microneurography could give precise indication on the receptors participating in our task (Vallbo, 1970; Burke et al., 1976; Roll and Vedel, 1982; Johansson and Valbo, 1983; Roll et al., 1989; Johansson and Birznieks, 2004).”
BackgroundWhole Body Vibration Improves Cognition in Healthy Young Adults
Regterschot, G. R. H., van Heuvelen, M. J. G., Zeinstra, E. B., Fuermaier, A. B. M., Tucha, L., Koerts, J., Tucha, O. M., & van der Zee, E. A. (2014) · PLoS ONE · doi:10.1371/journal.pone.0100506 · Cited by 100
“ically to 30–40 Hz vibrations [9–11].”
Digital nerve anaesthesia decreases EMG-EMG coherence in a human precision grip task
Fisher, R. J., Galea, M. P., Brown, P., & Lemon, R. (2002) · Experimental Brain Research · doi:10.1007/s00221-002-1113-x · Cited by 93
“We assume that the main deficits which we have observed result from blockade of the rapid and slowly adapting cutaneous mechanoreceptors densely concentrated in the glabrous skin of the tips of the thumb and index finger ( Johansson and Vallbo 1983; Birznieks et al. 2001).”
BackgroundHuman shape recognition performance for 3D tactile display
Shimojo, M., Shinohara, M., & Fukui, Y. (1999) · IEEE Transactions on Systems Man and Cybernetics - Part A Systems and Humans · doi:10.1109/3468.798067 · Cited by 97
Klatzky, R. L., & Lederman, S. J. (2003) · Wiley eBooks · doi:10.1002/0471264385.wei0406 · Cited by 159
Effect of Muscle Biomechanics on the Quantification of Spasticity
Kamper, D. G., Schmit, B. D., & Rymer, W. Z. (2001) · Annals of Biomedical Engineering · doi:10.1114/1.1424918 · Cited by 90
Naito, E., & Ehrsson, H. H. (2006) · The Journal of Neuroscience · doi:10.1523/jneurosci.4835-05.2006 · Cited by 88
“In contrast, the skin contact between the palm and the object may stimulate slow adapting receptors in the skin (Johansson and Vallbo, 1983), which may provide partial information about the stereognostic properties of the object.”
BackgroundSensorimotor Control of Grasping: Physiology and Pathophysiology
Nowak, D. A., & Hermsdörfer, J. (2009) · Cambridge University Press eBooks · doi:10.1017/cbo9780511581267 · Cited by 97
“objects ( Johansson and Vallbo, 1983; Vallbo and Johansson, 1984) (further details see Fig.”
Golaszewski, S. M., Siedentopf, C., Baldauf, E., Koppelstaetter, F., Eisner, W., Unterrainer, J. M., Guendisch, G. M., Mottaghy, F. M., & Felber, S. R. (2002) · NeuroImage · doi:10.1006/nimg.2002.1195 · Cited by 94
Selectively stimulating skin receptors for tactile display
Asamura, N., Yokoyama, N., & Shinoda, H. (1998) · IEEE Computer Graphics and Applications · doi:10.1109/38.734977 · Cited by 87
“A method of selective stimulation Figure 1 shows a cross-section of human glabrous skin.(8) The tissue includes four kinds of mechanoreceptors, with each kind located at a specific level.”
MethodSCHADY, W. J. L., & TOREBJÖRK, H. E. (1983) · Acta Physiologica Scandinavica · doi:10.1111/j.1748-1716.1983.tb07337.x · Cited by 87
Lederman, S. J., Klatzky, R. L., Hamilton, C., & Ramsay, G. I. (1999) · Cited by 106
Importance of spike timing in touch: an analogy with hearing?
Saal, H. P., Wang, X., & Bensmaia, S. J. (2016) · Current Opinion in Neurobiology · doi:10.1016/j.conb.2016.07.013 · Cited by 79
“Because the conduction velocities of individual tactile nerve fibers vary over a range [17,18], they naturally act as delay lines; tactile features could therefore be extracted even without the need for precisely timed inhibition, a computation similar to that underlying auditory localization in birds [19,20] (Figure…”
BackgroundJohansson, R. S., Lemon, R. N., & Westling, G. (1994) · The Journal of Physiology · doi:10.1113/jphysiol.1994.sp020480 · Cited by 83
Self-citationHuman vs. robotic tactile sensing: Detecting lumps in soft tissue
Gwilliam, J. C., Pezzementi, Z. A., Jantho, E., Okamura, A. M., & Hsiao, S. S. (2010) · IEEE Haptics Symposium · doi:10.1109/haptic.2010.5444685 · Cited by 92
“Some neurophysiology studies have investigated the relationship between a mechanical stimulus to the finger and human perception, but only rigid stimuli were represented [13, 18].”
BackgroundResponses of mechanoreceptive afferent units in the glabrous skin of the human hand to vibration.
Lundström, R. (1986) · Scandinavian Journal of Work Environment & Health · doi:10.5271/sjweh.2121 · Cited by 84
Temporal-Code to Rate-Code Conversion by Neuronal Phase-Locked Loops
Ahissar, E. (1998) · Neural Computation · doi:10.1162/089976698300017683 · Cited by 95
“A perturbation will be canceled at the next cycle if G = −1, will be attenuated if −1 G 0, and will be inverted and attenuated if −2 G −1.”
Influential
Metadata
- Authors
- Johansson, R. S., & Vallbo, Å. B.
- Affiliations
- Umeå University (SE)
- ORCID
- Johansson, Roland S.
- Venue
- Trends in Neurosciences
- Publisher
- Elsevier BV
- Published
- 1983-01
- Volume
- 6
- Pages
- 27-32
- ISSN
- 0166-2236 (ISSN-L)
- OpenAlex
- W1981782232
- Semantic Scholar
- 6178209a5c32589ae458ba840168933806fd668d
- Cited by
- 680
- References
- 23
- Citations by year
- 2026: 18 · 2025: 33 · 2024: 13 · 2023: 28 · 2022: 21 · 2021: 34 · 2020: 29 · 2019: 25 · 2018: 20 · 2017: 24 · 2016: 22 · 2015: 13 · 2014: 25 · 2013: 20 · 2012: 22
- FWCI
- 2.22
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- Locations
- Trends in Neurosciences (publishedVersion)
- Funders
- Vetenskapsrådet
- Topics
- Life Sciences › Neuroscience › Cognitive Neuroscience › Tactile and Sensory Interactions
- Life Sciences › Neuroscience › Cognitive Neuroscience › Motor Control and Adaptation
- Life Sciences › Neuroscience › Sensory Systems › Ion Channels and Receptors
- Keywords
- glabrous skin, human hand, mechanoreceptors, volar skin, tactile perception, motor control
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.