Long-term biocompatibility of a corrodible peripheral iron stent in the porcine descending aorta
The DOI matches its Crossref record; 20 of the 20 references it cites were found in a registry or an index.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Intravascular Stents to Prevent Occlusion and Re-Stenosis after Transluminal Angioplasty
Sigwart, U., Puel, J., Mirkovitch, V., Joffre, F., & Kappenberger, L. (1987) · New England Journal of Medicine · doi:10.1056/nejm198703193161201 · Cited by 1,892
Donath, K., & Breuner, G. (1982) · Journal of Oral Pathology & Medicine · doi:10.1111/j.1600-0714.1982.tb00172.x · Cited by 1,636
van der Giessen, W. J., Lincoff, A. M., Schwartz, R. S., van Beusekom, H. M. M., Serruys, P. W., Holmes, D. R., Ellis, S. G., & Topol, E. J. (1996) · Circulation · doi:10.1161/01.cir.94.7.1690 · Cited by 852
Biocorrosion of magnesium alloys: a new principle in cardiovascular implant technology?
Heublein, B., Rohde, R., Kaese, V, Niemeyer, M., Hartung, W., & Haverich, A. (2003) · Heart · doi:10.1136/heart.89.6.651 · Cited by 806
Initial and 6-Month Results of Biodegradable Poly- l -Lactic Acid Coronary Stents in Humans
Tamai, H., Igaki, K., Kyo, E., Kosuga, K., Kawashima, A., Matsui, S., Komori, H., Tsuji, T., Motohara, S., & Uehata, H. (2000) · Circulation · doi:10.1161/01.cir.102.4.399 · Cited by 806
Ryan, M. P., Williams, D. E., Chater, R. J., Hutton, B. M., & McPhail, D. S. (2002) · Nature · doi:10.1038/415770a · Cited by 760
Donath, K. (1982) · Medical Entomology and Zoology · Cited by 643
Morphological Predictors of Restenosis After Coronary Stenting in Humans
Farb, A., Weber, D. K., Kolodgie, F. D., Burke, A. P., & Virmani, R. (2002) · Circulation · doi:10.1161/01.cir.0000019071.72887.bd · Cited by 593
Peuster, M., Wohlsein, P., Brügmann, M., Ehlerding, M., Seidler, K., Fink, C., Brauer, H., Fischer, A., & Hausdorf, G. (2001) · Heart · doi:10.1136/heart.86.5.563 · Cited by 569
Self-citationNickel and molybdenum contact allergies in patients with coronary in-stent restenosis
Köster, R., Vieluf, D., Kiehn, M., Sommerauer, M., Kähler, J., Baldus, S., Meinertz, T., & Hamm, C. W. (2000) · The Lancet · doi:10.1016/s0140-6736(00)03262-1 · Cited by 530
Cited by
Zheng, Y. F., Gu, X. N., & Witte, F. (2014) · Materials Science and Engineering: R: Reports · doi:10.1016/j.mser.2014.01.001 · Cited by 2,436
Wang, X., Xu, S., Zhou, S., Xu, W., Leary, M., Choong, P., Qian, M., Brandt, M., & Xie, Y. M. (2016) · Biomaterials · doi:10.1016/j.biomaterials.2016.01.012 · Cited by 2,121
Development of new metallic alloys for biomedical applications
Niinomi, M., Nakai, M., & Hieda, J. (2012) · Acta Biomaterialia · doi:10.1016/j.actbio.2012.06.037 · Cited by 1,623
In vitro corrosion and biocompatibility of binary magnesium alloys
Gu, X., Zheng, Y., Cheng, Y., Zhong, S., & Xi, T. (2009) · Biomaterials · doi:10.1016/j.biomaterials.2008.10.021 · Cited by 1,343
Recent advances on the development of magnesium alloys for biodegradable implants
Chen, Y., Xu, Z., Smith, C., & Sankar, J. (2014) · Acta Biomaterialia · doi:10.1016/j.actbio.2014.07.005 · Cited by 1,236
MgZnCa glasses without clinically observable hydrogen evolution for biodegradable implants
Zberg, B., Uggowitzer, P. J., & Löffler, J. F. (2009) · Nature Materials · doi:10.1038/nmat2542 · Cited by 899
Coronary stents: A materials perspective
Mani, G., Feldman, M. D., Patel, D., & Agrawal, C. M. (2007) · Biomaterials · doi:10.1016/j.biomaterials.2006.11.042 · Cited by 866
Review of magnesium-based biomaterials and their applications
Sezer, N., Evis, Z., Kayhan, S. M., Tahmasebifar, A., & Koç, M. (2018) · Journal of Magnesium and Alloys · doi:10.1016/j.jma.2018.02.003 · Cited by 704
Developments in metallic biodegradable stents☆
Hermawan, H., Dubé, D., & Mantovani, D. (2010) · Acta Biomaterialia · doi:10.1016/j.actbio.2009.10.006 · Cited by 604
Biodegradable Metals for Cardiovascular Stent Application: Interests and New Opportunities
Moravej, M., & Mantovani, D. (2011) · International Journal of Molecular Sciences · doi:10.3390/ijms12074250 · Cited by 600
Venezuela, J., & Dargusch, M. S. (2019) · Acta Biomaterialia · doi:10.1016/j.actbio.2019.01.035 · Cited by 588
Zinc-based alloys for degradable vascular stent applications
Mostaed, E., Sikora-Jasinska, M., Drelich, J. W., & Vedani, M. (2018) · Acta Biomaterialia · doi:10.1016/j.actbio.2018.03.005 · Cited by 565
Antibacterial metals and alloys for potential biomedical implants
Zhang, E., Zhao, X., Hu, J., Wang, R., Fu, S., & Qin, G. (2021) · Bioactive Materials · doi:10.1016/j.bioactmat.2021.01.030 · Cited by 552
Biodegradable Metals for Cardiovascular Stents: from Clinical Concerns to Recent Zn‐Alloys
Bowen, P. K., Shearier, E. R., Zhao, S., Guillory, R. J., Zhao, F., Goldman, J., & Drelich, J. W. (2016) · Advanced Healthcare Materials · doi:10.1002/adhm.201501019 · Cited by 544
A review of drug delivery systems based on nanotechnology and green chemistry: green nanomedicine
Jahangirian, H., Ghasemian lemraski, E., Webster, T. J., Rafiee-Moghaddam, R., & Abdollahi, Y. (2017) · International Journal of Nanomedicine · doi:10.2147/ijn.s127683 · Cited by 496
Dissolvable Metals for Transient Electronics
Yin, L., Cheng, H., Mao, S., Haasch, R., Liu, Y., Xie, X., Hwang, S., Jain, H., Kang, S., Su, Y., et al. (2014) · Advanced Functional Materials · doi:10.1002/adfm.201301847 · Cited by 487
Mostaed, E., Sikora-Jasinska, M., Mostaed, A., Loffredo, S., Demir, A. G., Previtali, B., Mantovani, D., Beanland, R., & Vedani, M. (2016) · Journal of the Mechanical Behavior of Biomedical Materials · doi:10.1016/j.jmbbm.2016.03.018 · Cited by 475
Progress of biodegradable metals
Li, H., Zheng, Y., & Qin, L. (2014) · Progress in Natural Science: Materials International · doi:10.1016/j.pnsc.2014.08.014 · Cited by 432
Current status and outlook on the clinical translation of biodegradable metals
Han, H.-S., Loffredo, S., Jun, I., Edwards, J., Kim, Y.-C., Seok, H.-K., Witte, F., Mantovani, D., & Glyn-Jones, S. (2019) · Materials Today · doi:10.1016/j.mattod.2018.05.018 · Cited by 423
Biodegradable materials for bone defect repair
Wei, S., Ma, J.-X., Xu, L., Gu, X.-S., & Ma, X.-L. (2020) · Military Medical Research · doi:10.1186/s40779-020-00280-6 · Cited by 406
Resorbable biomaterials as bone graft substitutes
Bohner, M. (2010) · Materials Today · doi:10.1016/s1369-7021(10)70014-6 · Cited by 405
Yang, H., Wang, C., Liu, C., Chen, H., Wu, Y., Han, J., Jia, Z., Lin, W., Zhang, D., Li, W., et al. (2017) · Biomaterials · doi:10.1016/j.biomaterials.2017.08.022 · Cited by 399
Kabir, H., Munir, K., Wen, C., & Li, Y. (2021) · Bioactive Materials · doi:10.1016/j.bioactmat.2020.09.013 · Cited by 397
Liu, B., & Zheng, Y. F. (2011) · Acta Biomaterialia · doi:10.1016/j.actbio.2010.11.001 · Cited by 396
Fe–Mn alloys for metallic biodegradable stents: Degradation and cell viability studies☆
Hermawan, H., Purnama, A., Dube, D., Couet, J., & Mantovani, D. (2010) · Acta Biomaterialia · doi:10.1016/j.actbio.2009.11.025 · Cited by 372
Potential biodegradable Zn-Cu binary alloys developed for cardiovascular implant applications
Tang, Z., Niu, J., Huang, H., Zhang, H., Pei, J., Ou, J., & Yuan, G. (2017) · Journal of the Mechanical Behavior of Biomedical Materials · doi:10.1016/j.jmbbm.2017.05.013 · Cited by 361
Materials, Designs, and Operational Characteristics for Fully Biodegradable Primary Batteries
Yin, L., Huang, X., Xu, H., Zhang, Y., Lam, J., Cheng, J., & Rogers, J. A. (2014) · Advanced Materials · doi:10.1002/adma.201306304 · Cited by 336
Current status and perspectives of zinc-based absorbable alloys for biomedical applications
Hernández-Escobar, D., Champagne, S., Yilmazer, H., Dikici, B., Boehlert, C. J., & Hermawan, H. (2019) · Acta Biomaterialia · doi:10.1016/j.actbio.2019.07.034 · Cited by 309
Additively manufactured biodegradable porous iron
Li, Y., Jahr, H., Lietaert, K., Pavanram, P., Yilmaz, A., Fockaert, L. I., Leeflang, M. A., Pouran, B., Gonzalez-Garcia, Y., Weinans, H., et al. (2018) · Acta Biomaterialia · doi:10.1016/j.actbio.2018.07.011 · Cited by 299
Micro-alloying with Mn in Zn–Mg alloy for future biodegradable metals application
Liu, X., Sun, J., Zhou, F., Yang, Y., Chang, R., Qiu, K., Pu, Z., Li, L., & Zheng, Y. (2016) · Materials & Design · doi:10.1016/j.matdes.2015.12.128 · Cited by 292
Iron–manganese: new class of metallic degradable biomaterials prepared by powder metallurgy
Hermawan, H., Alamdari, H., Mantovani, D., & Dubé, D. (2008) · Powder Metallurgy · doi:10.1179/174329008x284868 · Cited by 287
Three-dimensional printing of metals for biomedical applications
Ni, J., Ling, H., Zhang, S., Wang, Z., Peng, Z., Benyshek, C., Zan, R., Miri, A. K., Li, Z., Zhang, X., et al. (2019) · Materials Today Bio · doi:10.1016/j.mtbio.2019.100024 · Cited by 279
Endothelial Cellular Responses to Biodegradable Metal Zinc
Ma, J., Zhao, N., & Zhu, D. (2015) · ACS Biomaterials Science & Engineering · doi:10.1021/acsbiomaterials.5b00319 · Cited by 275
Novel high-strength, low-alloys Zn-Mg (< 0.1 wt% Mg) and their arterial biodegradation
Jin, H., Zhao, S., Guillory, R., Bowen, P. K., Yin, Z., Griebel, A., Schaffer, J., Earley, E. J., Goldman, J., & Drelich, J. W. (2018) · Materials Science and Engineering: C · doi:10.1016/j.msec.2017.11.021 · Cited by 271
Novel processing of iron–manganese alloy-based biomaterials by inkjet 3-D printing
Chou, D.-T., Wells, D., Hong, D., Lee, B., Kuhn, H., & Kumta, P. N. (2013) · Acta Biomaterialia · doi:10.1016/j.actbio.2013.04.016 · Cited by 259
Magnetic Helical Micromachines
Peyer, K. E., Tottori, S., Qiu, F., Zhang, L., & Nelson, B. J. (2013) · Chemistry – A European Journal · doi:10.1002/chem.201203364 · Cited by 258
Calcium phosphate bone graft substitutes: Failures and hopes
Bohner, M., Galea, L., & Doebelin, N. (2012) · Journal of the European Ceramic Society · doi:10.1016/j.jeurceramsoc.2012.02.028 · Cited by 256
In Vitro Cytotoxicity, Adhesion, and Proliferation of Human Vascular Cells Exposed to Zinc
Shearier, E. R., Bowen, P. K., He, W., Drelich, A., Drelich, J., Goldman, J., & Zhao, F. (2016) · ACS Biomaterials Science & Engineering · doi:10.1021/acsbiomaterials.6b00035 · Cited by 209
Xiao, C., Wang, L., Ren, Y., Sun, S., Zhang, E., Yan, C., Liu, Q., Sun, X., Shou, F., Duan, J., et al. (2018) · Journal of Materials Science & Technology · doi:10.1016/j.jmst.2018.01.006 · Cited by 204
Carluccio, D., Xu, C., Venezuela, J., Cao, Y., Kent, D., Bermingham, M., Demir, A. G., Previtali, B., Ye, Q., & Dargusch, M. (2020) · Acta Biomaterialia · doi:10.1016/j.actbio.2019.12.018 · Cited by 195
Zhu, S., Huang, N., Xu, L., Zhang, Y., Liu, H., Sun, H., & Leng, Y. (2009) · Materials Science and Engineering: C · doi:10.1016/j.msec.2008.12.019 · Cited by 192
Additively manufactured functionally graded biodegradable porous iron
Li, Y., Jahr, H., Pavanram, P., Bobbert, F. S. L., Puggi, U., Zhang, X.-Y., Pouran, B., Leeflang, M. A., Weinans, H., Zhou, J., et al. (2019) · Acta Biomaterialia · doi:10.1016/j.actbio.2019.07.013 · Cited by 189
Long-term surveillance of zinc implant in murine artery: Surprisingly steady biocorrosion rate
Drelich, A. J., Zhao, S., Guillory, R. J., Drelich, J. W., & Goldman, J. (2017) · Acta Biomaterialia · doi:10.1016/j.actbio.2017.05.045 · Cited by 188
“A similar conclusion was reached for the 12month corrosion of Fe stents in the porcine aorta [17].”
BackgroundBiomaterials‐Based Electronics: Polymers and Interfaces for Biology and Medicine
Muskovich, M., & Bettinger, C. J. (2012) · Advanced Healthcare Materials · doi:10.1002/adhm.201200071 · Cited by 182
Bioinspired surface functionalization of metallic biomaterials
Su, Y., Luo, C., Zhang, Z., Hermawan, H., Zhu, D., Huang, J., Liang, Y., Li, G., & Ren, L. (2018) · Journal of the Mechanical Behavior of Biomedical Materials · doi:10.1016/j.jmbbm.2017.08.035 · Cited by 179
“[149] Peuster M, Hesse C, Schloo T, Fink C, Beerbaum P, von Schnakenburg C.”
In vitro degradation and cell attachment of a PLGA coated biodegradable Mg–6Zn based alloy
Li, J. N., Cao, P., Zhang, X. N., Zhang, S. X., & He, Y. H. (2010) · Journal of Materials Science · doi:10.1007/s10853-010-4688-9 · Cited by 177
Continuum damage model for bioresorbable magnesium alloy devices — Application to coronary stents
Gastaldi, D., Sassi, V., Petrini, L., Vedani, M., Trasatti, S., & Migliavacca, F. (2011) · Journal of the Mechanical Behavior of Biomedical Materials · doi:10.1016/j.jmbbm.2010.11.003 · Cited by 173
A promising biodegradable magnesium alloy suitable for clinical vascular stent application
Mao, L., shen, L., Chen, J., Zhang, X., Kwak, M., Wu, Y., Fan, R., Zhang, L., Pei, J., Yuan, G., et al. (2017) · Scientific Reports · doi:10.1038/srep46343 · Cited by 171
Im, S. H., Jung, Y., & Kim, S. H. (2017) · Acta Biomaterialia · doi:10.1016/j.actbio.2017.07.019 · Cited by 171
Zhou, C., Li, H.-F., Yin, Y.-X., Shi, Z.-Z., Li, T., Feng, X.-Y., Zhang, J.-W., Song, C.-X., Cui, X.-S., Xu, K.-L., et al. (2019) · Acta Biomaterialia · doi:10.1016/j.actbio.2019.08.012 · Cited by 171
Bone cement based nanohybrid as a super biomaterial for bone healing
Kapusetti, G., Misra, N., Singh, V., Srivastava, S., Roy, P., Dana, K., & Maiti, P. (2014) · J. Mater. Chem. B · doi:10.1039/c4tb00501e · Cited by 39
Metadata
- Authors
- Peuster, M., Hesse, C., Schloo, T., Fink, C., Beerbaum, P., & von Schnakenburg, C.
- Venue
- Biomaterials
- Publisher
- Elsevier BV
- Published
- 2006-10
- Volume
- 27
- Issue
- 28
- Pages
- 4955-4962
- ISSN
- 0142-9612 (ISSN-L)
- OpenAlex
- W1992011696
- Cited by
- 558
- References
- 20
- FWCI
- 7.17
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.