Long-term usability and bio-integration of polyimide-based intra-neural stimulating electrodes
Open accessAbstract
Stimulation of peripheral nerves has transiently restored lost sensation and has the potential to alleviate motor deficits. However, incomplete characterization of the long-term usability and bio-integration of intra-neural implants has restricted their use for clinical applications. Here, we conducted a longitudinal assessment of the selectivity, stability, functionality, and biocompatibility of polyimide-based intra-neural implants that were inserted in the sciatic nerve of twenty-three healthy adult rats for up to six months. We found that the stimulation threshold and impedance of the electrodes increased moderately during the first four weeks after implantation, and then remained stable over the following five months. The time course of these adaptations correlated with the progressive development of a fibrotic capsule around the implants. The selectivity of the electrodes enabled the preferential recruitment of extensor and flexor muscles of the ankle. Despite the foreign body reaction, this selectivity remained stable over time. These functional properties supported the development of control algorithms that modulated the forces produced by ankle extensor and flexor muscles with high precision. The comprehensive characterization of the implant encapsulation revealed hyper-cellularity, increased microvascular density, Wallerian degeneration, and infiltration of macrophages within the endoneurial space early after implantation. Over time, the amount of macrophages markedly decreased, and a layer of multinucleated giant cells surrounded by a capsule of fibrotic tissue developed around the implant, causing an enlargement of the diameter of the nerve. However, the density of nerve fibers above and below the inserted implant remained unaffected. Upon removal of the implant, we did not detect alteration of skilled leg movements and only observed mild tissue reaction. Our study characterized the interplay between the development of foreign body responses and changes in the electrical properties of actively used intra-neural electrodes, highlighting functional stability of polyimide-based implants over more than six months. These results are essential for refining and validating these implants and open a realistic pathway for long-term clinical applications in humans.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“A further study evaluated the results of SELINE insertion into the sciatic nerve of rats for 6 months [181]. Inflammatory response with swollen fibers was observed in the early phase after implantation, but it gradually resulted in capsule formation around the place of implantation, and all of the electrodes were functional at the end of the study.”
From Interfaces with the peripheral nervous system for the control of a neuroprosthetic limb: a review (2020) · cites this paper as [181]
In the citing paper
“The selectivity, longevity, and long-term stability are absolutely an integral part for the establishment of long-lasting and functional sensory feedback for an amputee (Warren et al., 2016; Wurth et al., 2017).”
From Selectivity and Longevity of Peripheral-Nerve and Machine Interfaces: A Review. (2017) · cites this paper as Wurth et al., 2017
In the citing paper
“The most recent study of Wurth et al. (2017) has demonstrated the selectivity, stability, longevity, and biocompatibility of intra-neural type interfaces.”
From Selectivity and Longevity of Peripheral-Nerve and Machine Interfaces: A Review. (2017) · cites this paper as Wurth et al. (2017)
Citations
Cites
Foreign body reaction to biomaterials
Anderson, J. M., Rodriguez, A., & Chang, D. T. (2008) · Seminars in Immunology · doi:10.1016/j.smim.2007.11.004 · Cited by 5,138
A review of shape memory alloy research, applications and opportunities
Jani, J. M., Leary, M., Subic, A., & Gibson, M. A. (2013) · Materials & Design (1980-2015) · doi:10.1016/j.matdes.2013.11.084 · Cited by 4,205
Altman, G. H., Diaz, F., Jakuba, C., Calabro, T., Horan, R. L., Chen, J., Lu, H., Richmond, J., & Kaplan, D. L. (2003) · Biomaterials · doi:10.1016/s0142-9612(02)00353-8 · Cited by 3,458
Regeneration beyond the glial scar
Silver, J., & Miller, J. H. (2004) · Nature reviews. Neuroscience · doi:10.1038/nrn1326 · Cited by 3,151
Response of brain tissue to chronically implanted neural electrodes
Polikov, V. S., Tresco, P. A., & Reichert, W. M. (2005) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2005.08.015 · Cited by 1,896
The Laboratory Rat: Relating Its Age With Human's.
(2013) · Europe PMC (PubMed Central) · Cited by 1,705
Biological Responses to Materials
Anderson, J. M. (2001) · Annual Review of Materials Research · doi:10.1146/annurev.matsci.31.1.81 · Cited by 1,465
Electronic dura mater for long-term multimodal neural interfaces
Minev, I. R., Musienko, P., Hirsch, A., Barraud, Q., Wenger, N., Moraud, E. M., Gandar, J., Capogrosso, M., Milekovic, T., Asboth, L., et al. (2015) · Science · doi:10.1126/science.1260318 · Cited by 1,082
Self-citationRestoring natural sensory feedback in real-time bidirectional hand prostheses
Raspopovic, S., Capogrosso, M., Petrini, F. M., Bonizzato, M., Rigosa, J., Di Pino, G., Carpaneto, J., Controzzi, M., Boretius, T., Fernandez, E., et al. (2014) · Science Translational Medicine · doi:10.1126/scitranslmed.3006820 · Cited by 1,001
Self-citationMacrophage-Induced Blood Vessels Guide Schwann Cell-Mediated Regeneration of Peripheral Nerves
Cattin, A.-L., Burden, J. J., Emmenis, L. V., Mackenzie, F. E., Hoving, J. J., Calavia, N. G., Guo, Y., McLaughlin, M., Rosenberg, L. H., Quereda, V., et al. (2015) · Cell · doi:10.1016/j.cell.2015.07.021 · Cited by 975
Cited by
Sorted by citations
Foreign Body Reaction to Implanted Biomaterials and Its Impact in Nerve Neuroprosthetics
Carnicer-Lombarte, A., Chen, S.-T., Malliaras, G. G., & Barone, D. G. (2021) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2021.622524 · Cited by 454
“Self-deploying anchors can also be incorporated into intraneural designs, minimizing movement and the associated trauma following implantation, as seen with self-opening neural interface (SELINE) devices (Cutrone et al., 2015), and generating minimal FBR (Wurth et al., 2017).”
BackgroundSensory feedback for limb prostheses in amputees
Raspopovic, S., Valle, G., & Petrini, F. M. (2021) · Nature Materials · doi:10.1038/s41563-021-00966-9 · Cited by 308
Toward higher-performance bionic limbs for wider clinical use
Farina, D., Vujaklija, I., Brånemark, R., Bull, A. M. J., Dietl, H., Graimann, B., Hargrove, L. J., Hoffmann, K.-P., Huang, H., Ingvarsson, T., et al. (2021) · Nature Biomedical Engineering · doi:10.1038/s41551-021-00732-x · Cited by 263
Self-citationRestoration of sensory information via bionic hands
Bensmaı̈a, S. J., Tyler, D. J., & Micera, S. (2020) · Nature Biomedical Engineering · doi:10.1038/s41551-020-00630-8 · Cited by 264
Self-citationRecent Advances in Materials, Devices, and Systems for Neural Interfaces
Won, S. M., Song, E., Zhao, J., Li, J., Rivnay, J., & Rogers, J. A. (2018) · Advanced Materials · doi:10.1002/adma.201800534 · Cited by 206
Biocompatibility of Polyimides: A Mini-Review
Constantin, C.-P., Aflori, M., Damian, R. F., & Rusu, R. (2019) · Materials · doi:10.3390/ma12193166 · Cited by 203
Six‐Month Assessment of a Hand Prosthesis with Intraneural Tactile Feedback
Petrini, F. M., Valle, G., Strauss, I., Granata, G., Di Iorio, R., D'Anna, E., Čvančara, P., Mueller, M., Carpaneto, J., Clemente, F., et al. (2019) · Annals of Neurology · doi:10.1002/ana.25384 · Cited by 195
Self-citationA review for the peripheral nerve interface designer
Larson, C. E., & Meng, E. (2020) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2019.108523 · Cited by 133
In Vivo Organic Bioelectronics for Neuromodulation
Magnus Berggren, A., Głowacki, E. D., Simon, D. T., Stavrinidou, E., & Tybrandt, K. (2022) · Chemical Reviews · doi:10.1021/acs.chemrev.1c00390 · Cited by 126
Interfaces with the peripheral nervous system for the control of a neuroprosthetic limb: a review
Yildiz, K. A., Shin, A. Y., & Kaufman, K. R. (2020) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-020-00667-5 · Cited by 113
Invasive Intraneural Interfaces: Foreign Body Reaction Issues
Lotti, F., Ranieri, F., Vadalà, G., Zollo, L., & Pino, G. D. (2017) · Frontiers in Neuroscience · doi:10.3389/fnins.2017.00497 · Cited by 122
Bioelectronic medicine: Preclinical insights and clinical advances
Pavlov, V. A., & Tracey, K. J. (2022) · Neuron · doi:10.1016/j.neuron.2022.09.003 · Cited by 110
Selectivity and Longevity of Peripheral-Nerve and Machine Interfaces: A Review.
Ghafoor, U., Kim, S., & Hong, K.-S. (2017) · Frontiers in Neurorobotics · doi:10.3389/fnbot.2017.00059 · Cited by 88
“Different types of interfaces have been tested by several research groups on animals for checking their biocompatibility, recording and stimulating abilities for instance; Polyimide-based intra-neural implants (Wurth et al., 2017), USEA (Christensen et al.”
InfluentialInkjet-printed PEDOT:PSS multi-electrode arrays for low-cost in vitro electrophysiology
Garma, L. D., Ferrari, L. M., Scognamiglio, P., Greco, F., & Santoro, F. (2019) · Lab on a Chip · doi:10.1039/c9lc00636b · Cited by 94
On the use of Parylene C polymer as substrate for peripheral nerve electrodes
de la Oliva, N., Mueller, M. C., Stieglitz, T., Navarro, X., & del Valle, J. (2018) · Scientific Reports · doi:10.1038/s41598-018-24502-z · Cited by 82
Self-citationSpatially selective activation of the visual cortex via intraneural stimulation of the optic nerve
Gaillet, V., Cutrone, A., Artoni, F., Vagni, P., Mega Pratiwi, A., Romero, S. A., Lipucci Di Paola, D., Micera, S., & Ghezzi, D. (2019) · Nature Biomedical Engineering · doi:10.1038/s41551-019-0446-8 · Cited by 73
Self-citationDeployment of an electrocorticography system with a soft robotic actuator
Song, S., Fallegger, F., Trouillet, A., Kim, K., & Lacour, S. P. (2023) · Science Robotics · doi:10.1126/scirobotics.add1002 · Cited by 76
Tutorial: a computational framework for the design and optimization of peripheral neural interfaces
Romeni, S., Valle, G., Mazzoni, A., & Micera, S. (2020) · Nature Protocols · doi:10.1038/s41596-020-0377-6 · Cited by 77
Self-citationBioelectronic medicine for the autonomic nervous system: clinical applications and perspectives
Cracchiolo, M., Ottaviani, M. M., Panarese, A., Strauss, I., Vallone, F., Mazzoni, A., & Micera, S. (2021) · Journal of Neural Engineering · doi:10.1088/1741-2552/abe6b9 · Cited by 66
Self-citationIntrafascicular peripheral nerve stimulation produces fine functional hand movements in primates
Badi, M., Wurth, S. M., Scarpato, I., Roussinova, E., Losanno, E., Bogaard, A. R., Delacombaz, M., Borgognon, S., Čvančara, P., Fallegger, F., et al. (2021) · Science Translational Medicine · doi:10.1126/scitranslmed.abg6463 · Cited by 62
Self-citationLai, B., Zeng, X., Han, W., Che, M., Ding, Y., Li, G., & Zeng, Y. (2021) · Biomaterials · doi:10.1016/j.biomaterials.2021.121211 · Cited by 66
Motor-commands decoding using peripheral nerve signals: a review
Hong, K.-S., Aziz, N., & Ghafoor, U. (2018) · Journal of Neural Engineering · doi:10.1088/1741-2552/aab383 · Cited by 63
Compliant peripheral nerve interfaces.
Paggi, V., Akouissi, O., Micera, S., & Lacour, S. P. (2021) · Journal of Neural Engineering · doi:10.1088/1741-2552/abcdbe · Cited by 60
“As a result, these polymers have been used in recent decades to develop extraneural [186, 200, 201], intraneural [80, 112, 116, 202] and regenerative [123, 203, 204] devices alike.”
BackgroundSelf-citationGori, M., Vadalà, G., Giannitelli, S. M., Denaro, V., & Pino, G. D. (2021) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2021.659033 · Cited by 67
Ultracompliant Hydrogel‐Based Neural Interfaces Fabricated by Aqueous‐Phase Microtransfer Printing
Huang, W., Ong, X. C., Kwon, I. S., Gopinath, C., Fisher, L. E., Wu, H., Fedder, G. K., Gaunt, R. A., & Bettinger, C. J. (2018) · Advanced Functional Materials · doi:10.1002/adfm.201801059 · Cited by 61
Čvančara, P., Boretius, T., López-Álvarez, V. M., Maciejasz, P., Andreu, D., Raspopovic, S., Petrini, F., Micera, S., Granata, G., Fernandez, E., et al. (2020) · Journal of Neural Engineering · doi:10.1088/1741-2552/ab9a9a · Cited by 58
Self-citationCutrone, A., & Micera, S. (2019) · Advanced Healthcare Materials · doi:10.1002/adhm.201801345 · Cited by 58
Self-citationGiagka, V., & Serdijn, W. A. (2018) · Bioelectronic Medicine · doi:10.1186/s42234-018-0010-y · Cited by 58
de la Oliva, N., Navarro, X., & del Valle, J. (2017) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.36274 · Cited by 58
Self-citationHigh Density, Double-Sided, Flexible Optoelectronic Neural Probes With Embedded μLEDs
Reddy, J. W., Kimukin, I., Stewart, L. T., Ahmed, Z., Barth, A. L., Towe, E., & Chamanzar, M. (2019) · Frontiers in Neuroscience · doi:10.3389/fnins.2019.00745 · Cited by 55
Investigation of drug release modulation from poly(2-oxazoline) micelles through ultrasound
Salgarella, A. R., Zahoranová, A., Šrámková, P., Majerčíková, M., Pavlova, E., Luxenhofer, R., Kronek, J., Lacík, I., & Ricotti, L. (2018) · Scientific Reports · doi:10.1038/s41598-018-28140-3 · Cited by 57
Progress and challenges of implantable neural interfaces based on nature-derived materials
Riva, E. R., & Micera, S. (2021) · Bioelectronic Medicine · doi:10.1186/s42234-021-00067-7 · Cited by 59
Self-citationOttaviani, M. M., Vallone, F., Micera, S., & Recchia, F. A. (2022) · Frontiers in Cardiovascular Medicine · doi:10.3389/fcvm.2022.866957 · Cited by 56
Self-citationNovel diamond shuttle to deliver flexible neural probe with reduced tissue compression
Na, K., Sperry, Z. J., Lu, J., Vöröslakos, M., Parizi, S. S., Bruns, T. M., Yoon, E., & Seymour, J. P. (2020) · Microsystems & Nanoengineering · doi:10.1038/s41378-020-0149-z · Cited by 51
Stretchable gold nanowire-based cuff electrodes for low-voltage peripheral nerve stimulation
Lienemann, S., Zötterman, J., Farnebo, S., & Tybrandt, K. (2021) · Journal of Neural Engineering · doi:10.1088/1741-2552/abfebb · Cited by 48
Decoding of grasping tasks from intraneural recordings in trans-radial amputee
Cracchiolo, M., Valle, G., Petrini, F. M., Strauss, I., Granata, G., Stieglitz, T., Rossini, P. M., Raspopović, S., Mazzoni, A., & Micera, S. (2020) · Journal of Neural Engineering · doi:10.1088/1741-2552/ab8277 · Cited by 46
Self-citationMultifaceted understanding of human nerve implants to design optimized electrodes for bioelectronics
Valle, G., Aiello, G., Ciotti, F., Čvančara, P., Martinović, T., Kravic‐Stevovic, T., Navarro, X., Stieglitz, T., Bumbaširević, M., & Raspopović, S. (2022) · Biomaterials · doi:10.1016/j.biomaterials.2022.121874 · Cited by 44
Self-citationYan, D., Jiman, A. A., Bottorff, E. C., Patel, P. R., Meli, D., Welle, E. J., Ratze, D. C., Havton, L. A., Chestek, C. A., Kemp, S. W. P., et al. (2022) · Small · doi:10.1002/smll.202200311 · Cited by 44
Magnetic Actuation of Flexible Microelectrode Arrays for Neural Activity Recordings
Gao, L., Wang, J., Guan, S., Du, M., Wu, K., Xu, K., Zou, L., Tian, H., & Fang, Y. Z. (2019) · Nano Letters · doi:10.1021/acs.nanolett.9b03232 · Cited by 41
Formation and biological activities of foreign body giant cells in response to biomaterials
Cai, F., Jiang, B., & He, F. (2024) · Acta Biomaterialia · doi:10.1016/j.actbio.2024.08.034 · Cited by 46
Development of micropatterning polyimide films for enhanced antifouling and antibacterial properties
Cuello, E. A., Mulko, L. E., Barbero, C. A., Acevedo, D. F., & Yslas, E. I. (2020) · Colloids and Surfaces B Biointerfaces · doi:10.1016/j.colsurfb.2020.110801 · Cited by 37
Graphene and graphene-related materials as brain electrodes
Xu, B., Pei, J., Feng, L., & Zhang, X. (2021) · Journal of Materials Chemistry B · doi:10.1039/d1tb01795k · Cited by 37
Treľová, D., Salgarella, A. R., Ricotti, L., Giudetti, G., Cutrone, A., Šrámková, P., Zahoranová, A., Chorvat, D., Jr., Haško, D., Canale, C., et al. (2018) · Langmuir · doi:10.1021/acs.langmuir.8b00765 · Cited by 35
Self-citationFrom softening polymers to multimaterial based bioelectronic devices
Ecker, M., Joshi-Imre, A., Modi, R., Frewin, C. L., Garcia-Sandoval, A., Maeng, J., Gutierrez-Heredia, G., Pancrazio, J. J., & Voit, W. E. (2019) · Multifunctional Materials · doi:10.1088/2399-7532/aaed58 · Cited by 34
He, G., Dong, X., & Qi, M. (2020) · Materials Research Express · doi:10.1088/2053-1591/abb857 · Cited by 39
All‐Polymer Based Stretchable Rubbery Electronics and Sensors
Rao, Z., Thukral, A., Yang, P., Lu, Y., Shim, H., Wu, W., Karim, A., & Yu, C. (2021) · Advanced Functional Materials · doi:10.1002/adfm.202111232 · Cited by 34
Recalibration of neuromodulation parameters in neural implants with adaptive Bayesian optimization
Aiello, G., Valle, G., & Raspopović, S. (2023) · Journal of Neural Engineering · doi:10.1088/1741-2552/acc975 · Cited by 32
de la Oliva, N., Navarro, X., & del Valle, J. (2018) · The Anatomical Record · doi:10.1002/ar.23920 · Cited by 35
Self-citationA modular strategy for next-generation upper-limb sensory-motor neuroprostheses
Shokur, S., Mazzoni, A., Schiavone, G., Weber, D. J., & Micera, S. (2021) · Med · doi:10.1016/j.medj.2021.05.002 · Cited by 35
Self-citationKasper, M., Ellenbogen, B., Hardy, R., Cydis, M., Mojica-Santiago, J., Afridi, A., Spearman, B. S., Singh, I., Kuliasha, C. A., Atkinson, E. W., et al. (2021) · Biomaterials · doi:10.1016/j.biomaterials.2021.121212 · Cited by 32
Harland, B. C., Aqrawe, Z., Vomero, M., Boehler, C., Cheah, E., Raos, B. J., Asplund, M., O’Carroll, S. J., & Svirskis, D. M. (2022) · Advanced Science · doi:10.1002/advs.202105913 · Cited by 30
Evaluation of high-density, multi-contact nerve cuffs for activation of grasp muscles in monkeys
Brill, N., Naufel, S. N., Polasek, K. H., Éthier, C., Cheesborough, J. E., Agnew, S. P., Miller, L. E., & Tyler, D. J. (2017) · Journal of Neural Engineering · doi:10.1088/1741-2552/aa8735 · Cited by 30
A soft, scalable and adaptable multi-contact cuff electrode for targeted peripheral nerve modulation
Paggi, V., Fallegger, F., Serex, L., Rizzo, O., Galan, K., Giannotti, A., Furfaro, I., Zinno, C., Bernini, F., Micera, S., et al. (2024) · Bioelectronic Medicine · doi:10.1186/s42234-023-00137-y · Cited by 32
Self-citationLu, B., Jia, S., Wang, Z., Wu, W., Yan, L. W., Zhu, L., & Hao, D. (2022) · Nano Energy · doi:10.1016/j.nanoen.2022.108133 · Cited by 27
Multilayer 3D electrodes for neural implants
Leccardi, M. J. I. A., Vagni, P., & Ghezzi, D. (2018) · Journal of Neural Engineering · doi:10.1088/1741-2552/aae191 · Cited by 26
Long-term functionality of transversal intraneural electrodes is improved by dexamethasone treatment
de la Oliva, N., del Valle, J., Delgado-Martinez, I., Mueller, M., Stieglitz, T., & Navarro, X. (2019) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2019.2897256 · Cited by 26
Self-citationČvančara, P., Valle, G., Müller, M., Bartels, I., Guiho, T., Hiairrassary, A., Petrini, F. M., Raspopović, S., Strauss, I., Granata, G., et al. (2023) · npj Flexible Electronics · doi:10.1038/s41528-023-00284-x · Cited by 27
Self-citationFedor, F. Z., Madarász, M., Zátonyi, A., Szabó, Á., Lőrincz, T., Danda, V. R., Spurgin, L., Manz, C., Rózsa, B. J., & Fekete, Z. (2021) · Advanced Materials Technologies · doi:10.1002/admt.202100942 · Cited by 25
Flexible IrOx neural electrode for mouse vagus nerve stimulation
Sun, T., Tsaava, T., Peragine, J., Crosfield, C., Lopez, M. F., Modi, R., Sharma, R., Li, C., Sohal, H. S., Chang, E. H., et al. (2023) · Acta Biomaterialia · doi:10.1016/j.actbio.2023.01.026 · Cited by 25
Rapid prototyping of flexible intrafascicular electrode arrays by picosecond laser structuring
Mueller, M. C., de la Oliva, N., del Valle, J., Delgado-Martínez, I., Navarro, X., & Stieglitz, T. (2017) · Journal of Neural Engineering · doi:10.1088/1741-2552/aa7eea · Cited by 25
Self-citationBayesian optimization of peripheral intraneural stimulation protocols to evoke distal limb movements
Losanno, E., Badi, M., Wurth, S. M., Borgognon, S., Courtine, G., Capogrosso, M., Rouiller, E. M., & Micera, S. (2021) · Journal of Neural Engineering · doi:10.1088/1741-2552/ac3f6c · Cited by 22
Self-citationJung, H. H., Ha, J., Park, J., Kang, S., Kim, J., Jung, H. N., Kim, S., Yea, J., Lee, H., Oh, S., et al. (2023) · Advanced Functional Materials · doi:10.1002/adfm.202311436 · Cited by 22
Koppaka, S., Hess‐Dunning, A., & Tyler, D. J. (2022) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2022.111058 · Cited by 20
Conformable neural interface based on off-stoichiometry thiol-ene-epoxy thermosets
Borda, E., Medagoda, D. I., Leccardi, M. J. I. A., Zollinger, E. G., & Ghezzi, D. (2022) · Biomaterials · doi:10.1016/j.biomaterials.2022.121979 · Cited by 20
Q-PINE: A quick to implant peripheral intraneural electrode
Strauss, I., Niederhoffer, T., Giannotti, A., Panarese, A. M., Bernini, F., Gabisonia, K., Ottaviani, M. M., Petrini, F. M., Recchia, F. A., Raspopović, S., et al. (2020) · Journal of Neural Engineering · doi:10.1088/1741-2552/abc52a · Cited by 19
Self-citationRomeni, S., Losanno, E., Koert, E., Pierantoni, L., Delgado-Martínez, I., Navarro, X., & Micera, S. (2023) · Journal of Neural Engineering · doi:10.1088/1741-2552/ace219 · Cited by 18
Self-citationA Novel Dual-Band MIMO-Enabled Biotelemetric Endovascular Stent IoMT System
Abdin, Z. U., Shah, S. A. A., Shah, I. A., Iman, U. R., Mian, S. H., & Yoo, H. (2025) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2025.3576004 · Cited by 17
Bioelectronics for targeted pain management
Flavin, M. T., Foppiani, J., Paul, M. A., Alvarez, A. H., Foster, L., Gavlasova, D., Ma, H., Rogers, J. A., & Lin, S. J. (2025) · Nature Reviews Electrical Engineering · doi:10.1038/s44287-025-00177-3 · Cited by 18
Chen, K.-S., Chan, H.-C., & Chan, C.-M. (2025) · Journal of Biological Engineering · doi:10.1186/s13036-025-00548-2 · Cited by 19
Lim, J., Zoss, P., Powley, T. L., Lee, H., & Ward, M. P. (2024) · Microsystems & Nanoengineering · doi:10.1038/s41378-023-00637-6 · Cited by 18
Carbohydrate based biomaterials for neural interface applications
Dhawan, V., & Cui, X. T. (2022) · Journal of Materials Chemistry B · doi:10.1039/d2tb00584k · Cited by 17
A review: flexible devices for nerve stimulation
Liu, Z.-Q., Yu, X.-Y., Huang, J., Wu, X.-Y., Wang, Z.-Y., & Zhu, B. (2024) · Soft Science · doi:10.20517/ss.2023.36 · Cited by 15
Mobini, S., Kuliasha, C. A., Siders, Z. A., Bohmann, N. A., Jamal, S., Judy, J. W., Schmidt, C. E., & Brennan, A. B. (2020) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.37007 · Cited by 15
Zhang, Y., Jiang, W., Yuan, S., Zhao, Q., Liu, Z., & Yü, W. (2020) · International Journal of Nanomedicine · doi:10.2147/ijn.s273240 · Cited by 15
RetractedAsadullah, S., Mei, S., Yang, K., Hu, X., Wang, F., Yu, B., Wu, Z., & Wei, J. (2021) · Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials · doi:10.1016/j.jmbbm.2021.104800 · Cited by 15
Flexible and Soft Materials and Devices for Neural Interface
Castagnola, E., Zheng, X. S., & Cui, X. T. (2023) · Handbook of Neuroengineering · doi:10.1007/978-981-16-5540-1_5 · Cited by 15
Decoding bladder state from pudendal intraneural signals in pigs
Giannotti, A., Vecchio, S. L., Musco, S., Pollina, L., Vallone, F., Strauss, I., Paggi, V., Bernini, F., Gabisonia, K., Carlucci, L., et al. (2023) · APL Bioengineering · doi:10.1063/5.0156484 · Cited by 14
Self-citationAcute to long-term characteristics of impedance recordings during neurostimulation in humans
Cui, J., Mívalt, F., Sladky, V., Kim, J., Richner, T. J., Lundstrom, B. N., Gompel, J. J. V., Wang, H., Miller, K. J., Gregg, N. M., et al. (2024) · Journal of Neural Engineering · doi:10.1088/1741-2552/ad3416 · Cited by 14
Advancements and Challenges in Biomaterials: Innovations, Sustainability, and Future Prospects
Erzen, B., Karataş, M., Orhan, R., & Aydoğmuş, E. (2025) · Journal of Macromolecular Science Part B · doi:10.1080/00222348.2025.2476852 · Cited by 17
Polysaccharide Layer-by-Layer Coating for Polyimide-Based Neural Interfaces
Riva, E. R., D’Alessio, A., & Micera, S. (2022) · Micromachines · doi:10.3390/mi13050692 · Cited by 16
Self-citationPeripheral neurostimulation for encoding artificial somatosensations
Valle, G. (2022) · European Journal of Neuroscience · doi:10.1111/ejn.15822 · Cited by 17
Tong, F., Chen, S., Chen, Z., Lü, X., & Lu, Q. (2018) · RSC Advances · doi:10.1039/c8ra00479j · Cited by 13
Engineered Graphene Material Improves the Performance of Intraneural Peripheral Nerve Electrodes
Rodríguez‐Meana, B., del Valle, J., Viana, D., Walston, S. T., Ria, N., Masvidal‐Codina, E., Garrido, J. A., & Navarro, X. (2024) · Advanced Science · doi:10.1002/advs.202308689 · Cited by 13
Self-citationAdaptive biomimicry: design of neural interfaces with enhanced biointegration
Lara, R. P., Goding, J. A., & Green, R. A. (2021) · Current Opinion in Biotechnology · doi:10.1016/j.copbio.2021.10.004 · Cited by 13
Karczewski, A. M., Dingle, A. M., & Poore, S. O. (2021) · Frontiers in Neurorobotics · doi:10.3389/fnbot.2021.711028 · Cited by 13
Čvančara, P., Valle, G., Müller, M., Guiho, T., Hiairrassary, A., Petrini, F., Raspopovic, S., Strauss, I., Granata, G., Fernandez, E., et al. (2019) · doi:10.1101/653964 · Cited by 12
Self-citationFan, Q., Dai, H., Bai, J., Xu, J., Ma, Q., Fei, Z., Zhou, X., Leong, K. W., & Wang, C. (2021) · Fundamental Research · doi:10.1016/j.fmre.2021.10.007 · Cited by 12
Highly conformable chip-in-foil implants for neural applications
Stieglitz, T., Gueli, C., Martens, J., Floto, N., Eickenscheidt, M., Sporer, M., & Ortmanns, M. (2023) · Microsystems & Nanoengineering · doi:10.1038/s41378-023-00527-x · Cited by 12
Polyimide Electrode-Based Electrical Stimulation Impedes Early Stage Muscle Graft Regeneration
Srinivasan, S., Vyas, K., McAvoy, M., Calvaresi, P., Khan, O. F., Langer, R., Anderson, D. G., & Herr, H. (2019) · Frontiers in Neurology · doi:10.3389/fneur.2019.00252 · Cited by 11
Neural Interfaces Based on Amorphous Silicon Carbide Ultramicroelectrode Arrays
Deku, F., Ghazavi, A., & Cogan, S. F. (2018) · Bioelectronics in Medicine · doi:10.2217/bem-2018-0006 · Cited by 11
Ron, T., Leon, A., Kafri, A., Ashraf, A., Na, J., Babu, A., Banerjee, R., Brookbank, H., Muddaluri, S. R., Little, K. J., et al. (2023) · Pharmaceutics · doi:10.3390/pharmaceutics15112595 · Cited by 10
Wang, L., Dang, P., Zheng, H., Wei, L., Jiang, S., Wang, J., Cai, Y., Wang, W., Zhang, C., Li, N., et al. (2024) · Colloids and Surfaces A Physicochemical and Engineering Aspects · doi:10.1016/j.colsurfa.2024.134822 · Cited by 10
Minimally Invasive & Long‐lasting Neural Probes from a Materials Perspective
Veronica, A., Li, Y., & Hsing, I. (2019) · Electroanalysis · doi:10.1002/elan.201800719 · Cited by 11
Ureteral anastomosis with a polyimide stent in rat kidney transplantation
Wang, T., Yu, Z., Chen, C., Song, Y., Zeng, X., Su, Y., & Yi, C. (2020) · Renal Failure · doi:10.1080/0886022x.2020.1726386 · Cited by 10
Spatio-temporal feature extraction in sensory electroneurographic signals
Silveira, C. R. A., Khushaba, R. N., Brunton, E., & Nazarpour, K. (2022) · Philosophical Transactions of the Royal Society A Mathematical Physical and Engineering Sciences · doi:10.1098/rsta.2021.0268 · Cited by 8
López-Álvarez, V. M., Cobianchi, S., & Navarro, X. (2019) · Neuromodulation Technology at the Neural Interface · doi:10.1111/ner.12927 · Cited by 9
Self-citationMicroneedle Penetrating Array with Axon-Sized Dimensions for Cuff-less Peripheral Nerve Interfacing
Yan, D., Jiman, A. A., Ratze, D. C., Huang, S., Parizi, S. S., Welle, E. J., Ouyang, Z., Patel, P. R., Kushner, M. J., Chestek, C. A., et al. (2019) · International IEEE/EMBS Conference on Neural Engineering · doi:10.1109/ner.2019.8717097 · Cited by 9
Taghlabi, K. M., Cruz-Garza, J. G., Hassan, T., Potnis, O., Bhenderu, L. S. S., Guerrero, J. R., Whitehead, R. E., Wu, Y. C., Luan, L., Xie, C., et al. (2024) · Journal of Neural Engineering · doi:10.1088/1741-2552/ad200f · Cited by 8
Ethical imperatives in the commercialization of brain-computer interfaces
Boonstra, J. T. (2025) · IBRO Neuroscience Reports · doi:10.1016/j.ibneur.2025.10.004 · Cited by 8
Flexible multifunctional titania nanotube array platform for biological interfacing
Hamedani, H. A., Stegall, T., Yang, Y., Wang, H., Menon, A., Bhalotia, A., Karathanasis, E., Capadona, J. R., & Hess‐Dunning, A. (2023) · MRS Bulletin · doi:10.1557/s43577-023-00628-y · Cited by 8
Metadata
- Authors
- Wurth, S., Capogrosso, M., Raspopovic, S., Gandar, J., Federici, G., Kinany, N., Cutrone, A., Piersigilli, A., Pavlova, N., Guiet, R., Taverni, G., Rigosa, J., Shkorbatova, P., Navarro, X., Barraud, Q., Courtine, G., & Micera, S.
- Affiliations
- École Polytechnique Fédérale de Lausanne (CH)
- Scuola Superiore Sant'Anna (IT)
- University of Bern (CH)
- Pavlov Institute of Physiology of the Russian Academy of Sciences (RU)
- Scuola Internazionale Superiore di Studi Avanzati (IT)
- Universitat Autònoma de Barcelona (ES)
- Corresponding author
- Micera, S.
- ORCID
- Venue
- Biomaterials
- Publisher
- Elsevier BV
- Published
- 2017-04
- Volume
- 122
- Pages
- 114-129
- ISSN
- 0142-9612 (ISSN-L)
- OpenAlex
- W2578816048
- Cited by
- 176
- References
- 82
- Citations by year
- 2026: 16 · 2025: 16 · 2024: 20 · 2023: 18 · 2022: 20 · 2021: 29 · 2020: 16 · 2019: 19 · 2018: 15 · 2017: 7
- FWCI
- 7.65
- Type
- journal article
- Language
- en
- Open access
- bronze
- doi.org
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- www.elsevier.com/legal/tdmrep-license (tdm)
- www.elsevier.com/open-access/userlicense/1.0/ (am, 294 d)
- doi.org/10.15223/policy-017 (stm-asf)
- doi.org/10.15223/policy-037 (stm-asf)
- doi.org/10.15223/policy-012 (stm-asf)
- doi.org/10.15223/policy-029 (stm-asf)
- doi.org/10.15223/policy-004 (stm-asf)
- Locations
- Biomaterials (acceptedVersion)
- PubMed (publishedVersion)
- Infoscience (Ecole Polytechnique Fédérale de Lausanne) (submittedVersion)
- Infoscience (Ecole Polytechnique Fédérale de Lausanne) (submittedVersion, cc-by-nc-nd)
- Archive ouverte UNIGE (University of Geneva) (submittedVersion, cc-by)
- CINECA IRIS Institutional Research Information System (Sant'Anna School of Advanced Studies) (submittedVersion)
- Funders
- Wyss Center for Bio and Neuroengineering
- European Commission (FP7-611687)
- European Research Council (ERC 261247)
- École Polytechnique Fédérale de Lausanne
- International Foundation for Research in Paraplegia
- Fondation Bertarelli
- Schweizerischer Nationalfonds zur Förderung der Wissenschaftlichen Forschung (205321_170032, 315230_149902)
- Topics
- Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
- Life Sciences › Neuroscience › Neurology › Vagus Nerve Stimulation Research
- Physical Sciences › Engineering › Biomedical Engineering › Muscle activation and electromyography studies
- Keywords
- polyimide electrodes, peripheral nerve stimulation, sciatic nerve, long-term biocompatibility, foreign body reaction, fibrotic capsule, electrical impedance, stimulation threshold, Wallerian degeneration, macrophage infiltration, multinucleated giant cells, nerve regeneration, implant encapsulation
- MeSH terms
- Animals, Biocompatible Materials, Electric Stimulation, Equipment Design, Female, Longitudinal Studies, Microelectrodes, Rats, Inbred Lew, Resins, Synthetic, Sciatic Nerve, Treatment Outcome, Equipment Failure Analysis, Rats, Implantable Neurostimulators
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review