The DOI matches its Crossref record; 78 of the 78 references it cites were found in a registry or an index.
A review of operating performance in green buildings: Energy use, indoor environmental quality and occupant satisfaction
Open accessAbstract
This paper aims to review the published researches on post-occupancy performance of green buildings in terms of energy use, indoor environment quality (IEQ) and occupant satisfaction. A total of 925 related papers were searched and 106 articles were screened for deep review. The study also compared the actual operating performance of green buildings in China and the United States, with information collected from previous research. The findings of literature review can be summarized as follows: 1) Though with some exceptional cases, the energy performance of green buildings was on average better than the conventional counterparts with similar climate conditions; 2) A significant gap between the designed and operational energy consumption was found, and lots of green buildings saved less energy than expected; 3) No clear relationship between the actual energy use and the green building certification level could be observed; 4) The actual IEQ conditions of green buildings were not comparable in different countries due to the variance in design criterions and operation modes; 5) Green buildings generally had higher occupants’ satisfaction level than conventional buildings, although the subjective data from the U.S. did not support this inference. Furthermore, this study proposed two areas worthy further investigations in the field of post-occupancy evaluation on green buildings, including new data collection technologies and performance optimization at the comprehensive level.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Comparison of PubMed, Scopus, Web of Science, and Google Scholar: strengths and weaknesses
Falagas, M. E., Pitsouni, E. I., Malietzis, G. A., & Pappas, G. (2008) · The FASEB Journal · doi:10.1096/fj.07-9492lsf · Cited by 5,039
Ensuring Positiveness of the Scaled Difference Chi-square Test Statistic
Satorra, A., & Bentler, P. M. (2010) · Psychometrika · doi:10.1007/s11336-009-9135-y · Cited by 2,695
Green building research–current status and future agenda: A review
Zuo, J., & Zhao, Z.-Y. (2014) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2013.10.021 · Cited by 1,194
Dounis, A. I., & Caraiscos, C. (2009) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2008.09.015 · Cited by 851
Occupant productivity and office indoor environment quality: A review of the literature
Al Horr, Y., Arif, M., Kaushik, A., Mazroei, A., Katafygiotou, M., & Elsarrag, E. (2016) · Building and Environment · doi:10.1016/j.buildenv.2016.06.001 · Cited by 843
Three options for citation tracking: Google Scholar, Scopus and Web of Science
Bakkalbasi, N., Bauer, K., Glover, J., & Wang, L. (2006) · Biomedical Digital Libraries · doi:10.1186/1742-5581-3-7 · Cited by 752
Applying multi-objective genetic algorithms in green building design optimization
Wang, W., Zmeureanu, R., & Rivard, H. (2005) · Building and Environment · doi:10.1016/j.buildenv.2004.11.017 · Cited by 726
Individual difference in thermal comfort: A literature review
Wang, Z., de Dear, R., Luo, M., Lin, B., He, Y., Ghahramani, A., & Zhu, Y. (2018) · Building and Environment · doi:10.1016/j.buildenv.2018.04.040 · Cited by 675
Self-citationDo LEED-certified buildings save energy? Yes, but…
Newsham, G. R., Mancini, S., & Birt, B. J. (2009) · Energy and Buildings · doi:10.1016/j.enbuild.2009.03.014 · Cited by 630
Fisk, W. J. (2000) · Annual Review of Energy and the Environment · doi:10.1146/annurev.energy.25.1.537 · Cited by 557
Kim, J., Zhou, Y., Schiavon, S., Raftery, P., & Brager, G. (2018) · Building and Environment · doi:10.1016/j.buildenv.2017.12.011 · Cited by 478
(2013) · Designing Zero Carbon Buildings Using Dynamic Simulation Methods · doi:10.4324/9780203135754-30 · Cited by 404
The impact of thermal environment on occupant IEQ perception and productivity
Geng, Y., Ji, W., Lin, B., & Zhu, Y. (2017) · Building and Environment · doi:10.1016/j.buildenv.2017.05.022 · Cited by 388
Self-citationAre users more tolerant of ‘green’ buildings?
Leaman, A., & Bordass, B. (2007) · Building Research & Information · doi:10.1080/09613210701529518 · Cited by 383
(ACEEE summer study on energy efficiency in buildings)
Available, N. (1990) · University of North Texas Digital Library (University of North Texas) · Cited by 363
Do LEED-certified buildings save energy? Not really…
Scofield, J. H. (2009) · Energy and Buildings · doi:10.1016/j.enbuild.2009.08.006 · Cited by 352
Ahmad, M. W., Mourshed, M., Mundow, D., Sisinni, M., & Rezgui, Y. (2016) · Energy and Buildings · doi:10.1016/j.enbuild.2016.03.059 · Cited by 348
Wagner, A., Gossauer, E., Moosmann, C., Gropp, T., & Leonhart, R. (2007) · Energy and Buildings · doi:10.1016/j.enbuild.2007.02.013 · Cited by 343
Critical analysis of green building research trend in construction journals
Darko, A., & Chan, A. P. C. (2016) · Habitat International · doi:10.1016/j.habitatint.2016.07.001 · Cited by 342
Assessing building performance in use 4: the Probe occupant surveys and their implications
Leaman, A., & Bordass, B. (2001) · Building Research & Information · doi:10.1080/09613210010008045 · Cited by 332
Climate change, thermal comfort and energy: Meeting the design challenges of the 21st century
Holmes, M. J., & Hacker, J. N. (2007) · Energy and Buildings · doi:10.1016/j.enbuild.2007.02.009 · Cited by 319
Occupant satisfaction in LEED and non-LEED certified buildings
Altomonte, S., & Schiavon, S. (2013) · Building and Environment · doi:10.1016/j.buildenv.2013.06.008 · Cited by 319
Heinzerling, D., Schiavon, S., Webster, T., & Arens, E. (2013) · Building and Environment · doi:10.1016/j.buildenv.2013.08.027 · Cited by 308
A review of fault detection and diagnosis methodologies on air-handling units
Yu, Y., Woradechjumroen, D., & Yu, D. (2014) · Energy and Buildings · doi:10.1016/j.enbuild.2014.06.042 · Cited by 305
A multivariate-logistic model for acceptance of indoor environmental quality (IEQ) in offices
Wong, L. T., Mui, K. W., & Hui, P. S. (2007) · Building and Environment · doi:10.1016/j.buildenv.2007.01.001 · Cited by 298
Du, Z., Fan, B., Jin, X., & Chi, J. (2014) · Building and Environment · doi:10.1016/j.buildenv.2013.11.021 · Cited by 296
Listening to the occupants: a Web-based indoor environmental quality survey
Zagreus, L., Huizenga, C., Arens, E., & Lehrer, D. (2004) · Indoor Air · doi:10.1111/j.1600-0668.2004.00301.x · Cited by 294
An evaluation model for indoor environmental quality (IEQ) acceptance in residential buildings
Lai, A. C. K., Mui, K. W., Wong, L. T., & Law, L. Y. (2009) · Energy and Buildings · doi:10.1016/j.enbuild.2009.03.016 · Cited by 288
Data science for building energy management: A review
Molina-Solana, M., Ros, M., Ruiz, M. D., Gómez-Romero, J., & Martin-Bautista, M. J. (2017) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2016.11.132 · Cited by 287
Assessing building performance in use 3: energy performance of the Probe buildings
Bordass, B., Cohen, R., Standeven, M., & Leaman, A. (2001) · Building Research & Information · doi:10.1080/09613210010008036 · Cited by 285
Personalized human comfort in indoor building environments under diverse conditioning modes
Li, D., Menassa, C. C., & Kamat, V. R. (2017) · Building and Environment · doi:10.1016/j.buildenv.2017.10.004 · Cited by 284
Comfort of workers in office buildings: The European HOPE project
Bluyssen, P. M., Aries, M., & van Dommelen, P. (2011) · Building and Environment · doi:10.1016/j.buildenv.2010.07.024 · Cited by 265
Green occupants for green buildings: The missing link?
Deuble, M. P., & de Dear, R. J. (2012) · Building and Environment · doi:10.1016/j.buildenv.2012.02.029 · Cited by 263
Post-Occupancy Evaluation: An Inevitable Step Toward Sustainability
Meir, I. A., Garb, Y., Jiao, D., & Cicelsky, A. (2009) · Advances in Building Energy Research · doi:10.3763/aber.2009.0307 · Cited by 256
Comparison of evaluation standards for green building in China, Britain, United States
Zhang, Y., Wang, J., Hu, F., & Wang, Y. (2016) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2016.09.139 · Cited by 242
Scofield, J. H. (2013) · Energy and Buildings · doi:10.1016/j.enbuild.2013.08.032 · Cited by 241
Post-occupancy evaluation of 20 office buildings as basis for future IEQ standards and guidelines
Choi, J.-H., Loftness, V., & Aziz, A. (2011) · Energy and Buildings · doi:10.1016/j.enbuild.2011.08.009 · Cited by 231
Assessing building performance in use 1: the Probe process
Cohen, R., Standeven, M., Bordass, B., & Leaman, A. (2001) · Building Research & Information · doi:10.1080/09613210010008018 · Cited by 226
The impact of working in a green certified building on cognitive function and health
MacNaughton, P., Satish, U., Laurent, J. G. C., Flanigan, S., Vallarino, J., Coull, B., Spengler, J. D., & Allen, J. G. (2017) · Building and Environment · doi:10.1016/j.buildenv.2016.11.041 · Cited by 219
A study on energy performance of 30 commercial office buildings in Hong Kong
Jing, R., Wang, M., Zhang, R., Li, N., & Zhao, Y. (2017) · Energy and Buildings · doi:10.1016/j.enbuild.2017.03.042 · Cited by 199
Fault detection analysis using data mining techniques for a cluster of smart office buildings
Capozzoli, A., Lauro, F., & Khan, I. (2015) · Expert Systems with Applications · doi:10.1016/j.eswa.2015.01.010 · Cited by 195
Linking indoor environment conditions to job satisfaction: a field study
Newsham, G., Brand, J., Donnelly, C., Veitch, J., Aries, M., & Charles, K. (2009) · Building Research & Information · doi:10.1080/09613210802710298 · Cited by 194
Do ‘green’ buildings have better indoor environments? New evidence
Newsham, G. R., Birt, B. J., Arsenault, C., Thompson, A. J. L., Veitch, J. A., Mancini, S., Galasiu, A. D., Gover, B. N., Macdonald, I. A., & Burns, G. J. (2013) · Building Research & Information · doi:10.1080/09613218.2013.789951 · Cited by 191
A review of studies on green building assessment methods by comparative analysis
Li, Y., Chen, X., Wang, X., Xu, Y., & Chen, P.-H. (2017) · Energy and Buildings · doi:10.1016/j.enbuild.2017.04.076 · Cited by 185
Luo, M., Cao, B., Ji, W., Ouyang, Q., Lin, B., & Zhu, Y. (2016) · Energy and Buildings · doi:10.1016/j.enbuild.2015.11.004 · Cited by 176
Self-citationYoung Seung, L. E. E., & Guerin, D. A. (2009) · Indoor and Built Environment · doi:10.1177/1420326x09105455 · Cited by 163
Effects of office environment on employee satisfaction: a new analysis
Leder, S., Newsham, G. R., Veitch, J. A., Mancini, S., & Charles, K. E. (2016) · Building Research & Information · doi:10.1080/09613218.2014.1003176 · Cited by 160
Schiavon, S., & Altomonte, S. (2014) · Building and Environment · doi:10.1016/j.buildenv.2014.03.028 · Cited by 144
Pei, Z., Lin, B., Liu, Y., et al. (2014) · Building and Environment · doi:10.1016/j.buildenv.2014.10.015 · Cited by 140
Self-citationBOSSA: a multidimensional post-occupancy evaluation tool
Cândido, C., Kim, J., de Dear, R., et al. (2015) · Building Research & Information · doi:10.1080/09613218.2015.1072298 · Cited by 138
Post-occupancy studies of an office environment: Energy performance and occupants' satisfaction
Agha-Hossein, M. M., El-Jouzi, S., Elmualim, A. A., Ellis, J. A., & Williams, M. (2013) · Building and Environment · doi:10.1016/j.buildenv.2013.08.003 · Cited by 132
Residential adaptive comfort in a humid subtropical climate—Sydney Australia
de Dear, R., Kim, J., & Parkinson, T. (2017) · Energy and Buildings · doi:10.1016/j.enbuild.2017.11.028 · Cited by 132
The unintended consequences of decarbonising the built environment: A UK case study
Davies, M., & Oreszczyn, T. (2011) · Energy and Buildings · doi:10.1016/j.enbuild.2011.10.043 · Cited by 127
Brambilla, A., Salvalai, G., Imperadori, M., & Sesana, M. M. (2018) · Energy and Buildings · doi:10.1016/j.enbuild.2018.02.002 · Cited by 127
Hirst, N. A. C. (2013) · Springer eBooks · doi:10.1007/978-1-4471-4781-7_2 · Cited by 124
Effects of the physical work environment on physiological measures of stress
Thayer, J. F., Verkuil, B., Brosschotj, J. F., Kampschroer, K., West, A., Sterling, C., Christie, I. C., Abernethy, D. R., Sollers, J. J., Cizza, G., et al. (2010) · European Journal of Cardiovascular Prevention & Rehabilitation · doi:10.1097/hjr.0b013e328336923a · Cited by 115
Indoor Air '96. Proceedings of the 7th International Conference on Indoor Air Quality and Climate
Brohus, H., Knudsen, H. N., Nielsen, P. V., Clausen, G., & Fanger, P. O. (1996) · Indoor Air · Cited by 111
Cost-benefit analysis of green buildings: An Israeli office buildings case study
Gabay, H., Meir, I. A., Schwartz, M., & Werzberger, E. (2014) · Energy and Buildings · doi:10.1016/j.enbuild.2014.02.027 · Cited by 105
In-use monitoring of buildings: An overview of data collection methods
Guerra-Santin, O., & Tweed, C. (2015) · Energy and Buildings · doi:10.1016/j.enbuild.2015.02.042 · Cited by 105
Lighting Handbook: Reference & Application
Rea, & Mark, S. (1993) · Medical Entomology and Zoology · Cited by 100
Assessing building performance in use 2: technical performance of the Probe buildings
Bordass, B., Cohen, R., Standeven, M., et al. (2001) · Building Research & Information · doi:10.1080/09613210010008027 · Cited by 94
Long-term field survey on thermal adaptation in office buildings in Japan
Tomonobu, G. O. T. O., Mitamura, T., Yoshino, H., Tamura, A., & Inomata, E. (2006) · Building and Environment · doi:10.1016/j.buildenv.2006.06.026 · Cited by 89
Occupant thermal feedback for improved efficiency in university buildings
Pritoni, M., Salmon, K., Sanguinetti, A., et al. (2017) · Energy and Buildings · doi:10.1016/j.enbuild.2017.03.048 · Cited by 89
Diagnostic tools of energy performance for supermarkets using Artificial Neural Network algorithms
Mavromatidis, G., Acha, S., & Shah, N. (2013) · Energy and Buildings · doi:10.1016/j.enbuild.2013.03.020 · Cited by 87
Jradi, M., Arendt, K., Sangogboye, F. C., Mattera, C. G., Markoska, E., Kjærgaard, M. B., Veje, C. T., & Jôrgensen, B. N. (2018) · Energy and Buildings · doi:10.1016/j.enbuild.2018.02.005 · Cited by 83
Development of an energy monitoring system for large public buildings
Zhao, L., Zhang, J., & Liang, R. (2013) · Energy and Buildings · doi:10.1016/j.enbuild.2013.07.007 · Cited by 82
Lam, A. H.-Y., Yuan, Y., & Wang, D. (2014) · ACM International Conference on Future Energy Systems (e-Energy) · doi:10.1145/2602044.2602067 · Cited by 71
Newsham, G. R., Veitch, J. A., & Charles, K. (2008) · Indoor Air · doi:10.1111/j.1600-0668.2008.00525.x · Cited by 64
Building energy use in China: Ceiling and scenario
Chen, P., Yan, D., Guo, S., Hu, S., & Jiang, Y. (2015) · Energy and Buildings · doi:10.1016/j.enbuild.2015.05.049 · Cited by 57
Wang, H., Xu, P., Lu, X., & Yuan, D. (2016) · Applied Energy · doi:10.1016/j.apenergy.2016.01.054 · Cited by 54
A data-driven approach for building energy benchmarking using the Lorenz curve
Chen, Y., Tan, H., & Berardi, U. (2018) · Energy and Buildings · doi:10.1016/j.enbuild.2018.03.066 · Cited by 50
Co-optimisation of indoor environmental quality and energy consumption within urban office buildings
Tran, Q., He, C., Knibbs, L. D., de Dear, R., & Morawska, L. (2014) · QUT ePrints (Queensland University of Technology) · Cited by 45
A FIELD MEASUREMENT SYSTEM FOR THE STUDY OF THERMAL COMFORT
Benton, C., Bauman, F. S., & Fountain, M. (1990) · eScholarship (California Digital Library) · Cited by 41
Brown, C. O., & Gorgolewski, M. (2014) · International Journal of Energy Sector Management · doi:10.1108/ijesm-11-2013-0007 · Cited by 37
Na, W., Wu, Y. C., Yan, S., & Zhong-cheng, D. (2009) · Energy Policy · doi:10.1016/j.enpol.2008.12.032 · Cited by 31
Occupant feedback questionnaire producing a fingerprint and a score
Levermore, G. J., Lowe, D., & Ure, J. W. (1999) · Research Explorer (The University of Manchester) · Cited by 19
Building comfort performance assessment using a monitoring tool
Kemenade, V. P., Loomans, M. M., Opschoor, S., & Hensen, J. J. (2014) · TU/e Research Portal · Cited by 4
Cited by
Indoor transmission of SARS‐CoV‐2
Qian, H., Miao, T., Liu, L., Zheng, X., Luo, D., & Li, Y. (2021) · Indoor Air · doi:10.1111/ina.12766 · Cited by 549
Metadata
- Authors
- Geng, Y., Ji, W., Wang, Z., Lin, B., & Zhu, Y.
- Venue
- Energy and Buildings
- Publisher
- Elsevier BV
- Published
- 2019-01
- Volume
- 183
- Pages
- 500-514
- ISSN
- 0378-7788 (ISSN-L)
- OpenAlex
- W2901615719
- Cited by
- 324
- References
- 78
- FWCI
- 21.71
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.